首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lien KY  Chuang YH  Hung LY  Hsu KF  Lai WW  Ho CL  Chou CY  Lee GB 《Lab on a chip》2010,10(21):2875-2886
The present study reports a new three-dimensional (3D) microfluidic platform capable of rapid isolation and detection of cancer cells from a large sample volume (e.g. ~1 mL) by utilizing magnetic microbead-based technologies. Several modules, including a 3D microfluidic incubator for the magnetic beads to capture cancer cells, a microfluidic control module for sample transportation and a nucleic acid amplification module for genetic identification, are integrated into this microsystem. With the incorporation of surface-modified magnetic beads, target cancer cells can be specifically recognized and conjugated onto the surface of the antibody-coated magnetic microbeads by utilizing a swirling effect generated by the new 3D microfluidic incubator, followed by isolating and purifying the magnetic complexes via the incorporation of an external magnet and a microfluidic control module, which washes away any unbound waste solution. Experimental results show that over 90% of the target cancer cells can be isolated from a large volume of bio-samples within 10 min in the 3D microfluidic incubator. In addition, the expressed genes associated with ovarian and lung cancer cells can also be successfully amplified by using the on-chip nucleic acid amplification module. More importantly, the detection limit of the developed system is found to be 5 × 10(1) cells mL(-1) for the target cancer cells, indicating that this proposed microfluidic system may be adapted for clinical use for the early detection of cancer cells. Consequently, the proposed 3D microfluidic system incorporated with immunomagnetic beads may provide a promising automated platform for the rapid isolation and detection of cancer cells with a high sensitivity.  相似文献   

2.
This work presents a promising clinical molecular diagnostics for early stage lung cancer. This novel diagnostic method utilized the loop-mediated isothermal amplification (LAMP), microfluidic chips and a confocal optical detector with a non-linear fluorescent filter processor. An isothermal amplification based microfluidic chip for the early diagnostics of lung cancer was developed and a confocal optical detector was improved by a novel real-time fluorescent filter to sensitively monitor the DNA amplification procedure with high signal to noise ratio and fluorescence collecting ability. Experiment showed that a rapid diagnostic of lung cancer by detecting the existence of the CEA mRNA could be performed in only 5 μL of reaction assay in less than 45 min. While the traditional in-tube RT-PCR set consumed more than 25 μL of the assay and took more than 90 min.  相似文献   

3.
This study reports the development of a microfluidic bead-based nucleic acid sensor for sensitive detection of circulating tumor cells in blood samples using multienzyme-nanoparticle amplification and quantum dot labels. In this method, the microbeads functionalized with the capture probes and modified electron rich proteins were arrayed within a microfluidic channel as sensing elements, and the gold nanoparticles (AuNPs) functionalized with the horseradish peroxidases (HRP) and DNA probes were used as labels. Hence, two signal amplification approaches are integrated for enhancing the detection sensitivity of circulating tumor cells. First, the large surface area of Au nanoparticle carrier allows several binding events of HRP on each nanosphere. Second, enhanced mass transport capability inherent from microfluidics leads to higher capture efficiency of targets because continuous flow within micro-channel delivers fresh analyte solution to the reaction site which maintains a high concentration gradient differential to enhance mass transport. Based on the dual signal amplification strategy, the developed microfluidic bead-based nucleic acid sensor could discriminate as low as 5 fM (signal-to-noise (S/N) 3) of synthesized carcinoembryonic antigen (CEA) gene fragments and showed a 1000-fold increase in detection limit compared to the off-chip test. In addition, using spiked colorectal cancer cell lines (HT29) in the blood as a model system, the detection limit of this chip-based approach was found to be as low as 1 HT29 in 1 mL blood sample. This microfluidic bead-based nucleic acid sensor is a promising platform for disease-related nucleic acid molecules at the lowest level at their earliest incidence.  相似文献   

4.
Allen PB  Arshad SA  Li B  Chen X  Ellington AD 《Lab on a chip》2012,12(16):2951-2958
This article describes the use of non-enzymatic nucleic acid circuits based on strand exchange reactions to detect target sequences on a paperfluidic platform. The DNA circuits that were implemented include a non-enzymatic amplifier and transduction to a fluorescent reporter; these yield an order of magnitude improvement in detection of an input nucleic acid signal. To further improve signal amplification and detection, we integrated the enzyme-free amplifier with loop-mediated isothermal amplification (LAMP). By bridging the gap between the low concentrations of LAMP amplicons and the limits of fluorescence detection, the non-enzymatic amplifier allowed us to detect as few as 1200 input templates in a paperfluidic format.  相似文献   

5.
Highly sensitive digital nucleic acid techniques are of great significance for the prevention and control of epidemic diseases. Here we report the development of multiplexed droplet loop-mediated isothermal amplification (multiplexed dLAMP) with scorpion-shaped probes (SPs) and fluorescence microscopic counting for simultaneous quantification of multiple targets. A set of target-specific fluorescence-activable SPs are designed, which allows establishment of a novel multiplexed LAMP strategy for simultaneous detection of multiple cDNA targets. The digital multiplexed LAMP assay is thus developed by implementing the LAMP reaction using a droplet microfluidic chip coupled to a droplet counting microwell chip. The droplet counting system allows rapid and accurate counting of the numbers of total droplets and the positive droplets by collecting multi-color fluorescence images of the droplets in a microwell. The multiplexed dLAMP assay was successfully demonstrated for the quantification of HCV and HIV cDNA with high precision and detection limits as low as 4 copies per reaction. We also verified its potential for simultaneous digital assay of HCV and HIV RNA in clinical plasma samples. This multiplexed dLAMP technique can afford a useful platform for highly sensitive and specific detection of nucleic acids of viruses and other pathogens, enabling rapid diagnosis and prevention of infectious diseases.

The development of multiplexed dLAMP with scorpion-shaped probes and fluorescence microscopic counting affords simultaneous digital quantification of multiple virus RNAs.  相似文献   

6.
Miniaturized isothermal nucleic acid amplification, a review   总被引:1,自引:0,他引:1  
Asiello PJ  Baeumner AJ 《Lab on a chip》2011,11(8):1420-1430
Micro-Total Analysis Systems (μTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.  相似文献   

7.
Since 2005, celery and celery products have to be labeled according to Directive 2003/89/EC due to their allergenic potential. In order to provide a DNA-based, rapid and simple detection method suitable for high-throughput analysis, a loop-mediated isothermal amplification (LAMP) assay for the detection of celery (Apium graveolens) was developed. The assay was tested for specificity for celery since closely related species also hold food relevance. The limit of detection (LOD) for spiked food samples was found to be as low as 7.8 mg of dry celery powder per kilogram. An evaluation of different amplification and detection platforms was performed to show reliable detection independent from the instrument used for amplification (thermal cycler or heating block) and detection mechanisms (real-time fluorescence detection, agarose gel electrophoresis or nucleic acid staining). The analysis of 10 commercial food samples representing diverse and complex food matrices, and a false-negative rate of 0 % for approximately 24 target copies or 0.08 ng celery DNA for three selected food matrices show that LAMP has the potential to be used as an alternative strategy for the detection of allergenic celery. The performance of the developed LAMP assay turned out to be equal or superior to the best available PCR assay for the detection of celery in food products.  相似文献   

8.
Isothermal exponential amplification techniques, such as strand‐displacement amplification (SDA), rolling circle amplification (RCA), loop‐mediated isothermal amplification (LAMP), nucleic acid sequence based amplification (NASBA), helicase‐dependent amplification (HDA), and recombinase polymerase amplification (RPA), have great potential for on‐site, point‐of‐care, and in situ assay applications. These amplification techniques eliminate the need for temperature cycling, as required for the polymerase chain reaction (PCR), while achieving comparable amplification yields. We highlight here recent advances in the exponential amplification reaction (EXPAR) for the detection of nucleic acids, proteins, enzyme activities, cells, and metal ions. The incorporation of fluorescence, colorimetric, chemiluminescence, Raman, and electrochemical approaches enables the highly sensitive detection of a variety of targets. Remaining issues, such as undesirable background amplification resulting from nonspecific template interactions, must be addressed to further improve isothermal and exponential amplification techniques.  相似文献   

9.
10.
This report describes a novel diagnostic assay for rapid detection of the Panton-Valentine Leukocidin (PVL) toxin of methicillin-resistant Staphylococcus aureus (MRSA) utilizing resistive pulse sensing (RPS), loop-mediated isothermal DNA amplification (LAMP) in combination with gold nanoparticles (AuNPs). The PVL DNA from MRSA was specifically amplified by LAMP using four primers at one temperature (65 °C). The DNA products with biotin were then conjugated to a first AuNP1 (55 ± 2 nm) through biotin–avidin binding. A second AuNP2 (30 ± 1.5 nm) coated with a specific DNA probe hybridized with the LAMP DNA products at the loop region to enhance assay sensitivity and specificity, to generate supra-AuNP1-DNA-AuNP2 assemblies. Scanning electron microscopy confirmed the presence of these supra-assemblies. Using RPS, detection and quantitation of the agglomerated AuNPs were performed by a tunable fluidic nanopore sensor. The results demonstrate that the LAMP-based RPS sensor is sensitive and rapid for detecting the PVL DNA. This technique could achieve a limit of detection (LOD) up to about 500 copies of genomic DNA from the bacteria MRSA MW2 and the detection can be completed within two hours with a straightforward signal-to-readout setup. It is anticipated that this LAMP-based AuNP RPS may become an effective tool for MRSA detection and a potential platform in clinical laboratory to report the presence or absence of other types of infectious agents.  相似文献   

11.
于佳雪  王昶  杨媚婷  杜衍  刘畅 《应用化学》2022,39(3):498-506
为解决当前乙型肝炎病毒(HBV)基因检测技术在一定程度上存在成本高、操作繁琐、误诊率高等问题,在此提出了一种便携式生物传感平台用于HBV基因的超灵敏检测,可检出低至2 copies/μL的HBV基因.首次通过设计针对HBV检测序列的环介导等温扩增(LAMP)反应,实现了在40 min之内对HBV基因型单拷贝基因的检测....  相似文献   

12.

Loop-mediated isothermal amplification (LAMP) has been developed as a versatile method for nucleic acid analysis in many applications. However, non-specific LAMP leading to false-positive outcomes has been observed frequently. To solve this problem, we selected six molecules as the additives for evaluating their effects on the improvement of the LAMP specificity. Experimental results show that bovine serum albumin (BSA) and DL-dithiothreitol (DTT) have negative effects on the LAMP specificity; dimethyl sulfoxide (DMSO), tetramethylene sulfoxide (TMSO), and glycerol could inhibit the non-specific LAMP moderately. Surprisingly, pullulan shows an ability to inhibit the non-specific amplification of LAMP significantly without affecting the sample amplification of LAMP, and this inhibitory effect is concentration dependent. Thus, pullulan could be considered as the most promising additive to improve the amplification specificity in the LAMP-based detection and analysis of nucleic acids.

  相似文献   

13.
Liu C  Mauk MG  Hart R  Qiu X  Bau HH 《Lab on a chip》2011,11(16):2686-2692
A disposable, water-activated, self-heating, easy-to-use, polymeric cartridge for isothermal nucleic acid amplification and visual fluorescent detection of the amplification products is described. The device is self-contained and does not require any special instruments to operate. The cartridge integrates chemical, water-triggered, exothermic heating with temperature regulation facilitated with a phase-change material (PCM) and isothermal nucleic acid amplification. The water flows into the exothermic reactor by wicking through a porous paper. The porous paper's characteristics control the rate of water supply, which in turn controls the rate of exothermic reaction. The PCM material enables the cartridge to maintain a desired temperature independent of ambient temperatures in the range between 20 °C and 40 °C. The utility of the cartridge is demonstrated by amplifying and detecting Escherichia coli DNA with loop mediated isothermal amplification (LAMP). The device can detect consistently as few as 10 target molecules in the sample. With proper modifications, the cartridge also can work with other isothermal nucleic acid amplification technologies for detecting nucleic acids associated with various pathogens borne in blood, saliva, urine, and other body fluids as well as in water and food. The device is suitable for use at home, in the field, and in poor-resource settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent.  相似文献   

14.
Do J  Ahn CH 《Lab on a chip》2008,8(4):542-549
This paper presents a new polymer lab-on-a-chip for magnetic bead-based immunoassay with fully on-chip sampling and detection capabilities, which provides a smart platform of magnetic immunoassay-based lab-on-a-chip for point-of-care testing (POCT) toward biochemical hazardous agent detection, food inspection or clinical diagnostics. In this new approach, the polymer lab-on-a-chip for magnetic bead-based immunoassay consists of a magnetic bead-based separator, an interdigitated array (IDA) micro electrode, and a microfluidic system, which are fully incorporated into a lab-on-a-chip on cyclic olefin copolymer (COC). Since the polymer lab-on-a-chip was realized using low cost, high throughput polymer microfabrication techniques such as micro injection molding and hot embossing method, a disposable polymer lab-on-a-chip for the magnetic bead-based immunoassay can be successfully realized in a disposable platform. With this newly developed polymer lab-on-a-chip, an enzyme-labelled electrochemical immunoassay (ECIA) was performed using magnetic beads as the mobile solid support, and the final enzyme product produced from the ECIA was measured using chronoamperometry. A sampling and detection of as low as 16.4 ng mL(-1) of mouse IgG has been successfully performed in 35 min for the entire procedure.  相似文献   

15.
The detection of nucleic acid biomarkers for point‐of‐care (POC) diagnostics is currently limited by technical complexity, cost, and time constraints. To overcome these shortcomings, we have combined loop‐mediated isothermal amplification (LAMP), programmable toehold‐mediated strand‐exchange signal transduction, and standard pregnancy test strips. The incorporation of an engineered hCG–SNAP fusion reporter protein (human chorionic gonadotropin‐O6‐alkylguanine‐DNA alkyltransferase) led to LAMP‐to‐hCG signal transduction on low‐cost, commercially available pregnancy test strips. Our assay reliably detected as few as 20 copies of Ebola virus templates in both human serum and saliva and could be adapted to distinguish a common melanoma‐associated SNP allele (BRAF V600E) from the wild‐type sequence. The methods described are completely generalizable to many nucleic acid biomarkers, and could be adapted to provide POC diagnostics for a range of pathogens.  相似文献   

16.
刘萌  王子月  张春阳 《分析化学》2016,(12):1934-1941
化学发光分析是利用化学发光反应的发光现象,对化学发光物质由激发态跃迁回基态时发出的光信号进行测量的一种分析方法。化学发光分析具有无需外来光源、灵敏度高、操作方便、分析快速以及易于实现自动化等优点,可与其它分析技术联用,在临床检验、药物分析和环境监测等领域具有广泛应用。近年来,纳米材料、生物芯片及微流控技术的引入促进了化学发光分析技术的发展。本文综述了化学发光分析与高效液相色谱、毛细管电泳、量子点、微流控芯片和微阵列、以及滚环扩增、等温指数扩增和两级等温扩增联用技术的发展,介绍了化学发光分析技术在DNA、生物小分子、生物酶、蛋白质和金属离子检测中的应用研究进展,并展望了其发展趋势。  相似文献   

17.
18.
Applications of Loop-Mediated Isothermal DNA Amplification   总被引:2,自引:0,他引:2  
During the last 10 years, with the development of loop-mediated isothermal amplification (LAMP) method, it has been widely applied in nucleic acid analysis because of its simplicity, rapidity, high efficiency, and outstanding specificity. This method employs a DNA polymerase and a set of four specially designed primers that recognize a total of six distinct sequences on the target DNA. Expensive equipment are not necessary to acquire a high level of precision, and there are fewer preparation steps compared to conventional PCR and real-time PCR assays. This paper briefly summarized the applications of LAMP method in pathogenic microorganisms, genetically modified ingredients, tumor detection, and embryo sex identification.  相似文献   

19.
Loop mediated isothermal amplification (LAMP) is a nucleic acid amplification technique performed under isothermal conditions. The output of this amplification technique includes multiple different sizes of deoxyribonucleic acid (DNA) structures which are identified by a banding pattern on gel electrophoresis plots. Although this is a specific amplification technique, the complexity of the primer design and amplification still lead to the issue of obtaining false‐positive results, especially when a positive reading is determined solely by whether there is any banding pattern in the gel electrophoresis plot. Here, we first performed extensive LAMP experiments and evaluated the DNA structures using microchip electrophoresis. We then developed a mathematical model derived from the various components that make up an entire LAMP structure to predict the full LAMP structure size in base pairs. This model can be implemented by users to make predictions for specific, DNA size dependent, banding patterns on their gel electrophoresis plots. Each prediction is specific to the target sequence and primers used and therefore reduces incorrect diagnosis errors through identifying true‐positive and false‐positive results. This model was accurately tested with multiple primer sets in house and was also translatable to different DNA and RNA types in previously published literature. The mathematical model can ultimately be used to reduce false‐positive LAMP diagnosis errors for applications ranging from tuberculosis diagnostics to E. coli to numerous other infectious diseases.  相似文献   

20.
Nowadays nucleic acid tests are promising to be considered as point-of-care testing(POCT). However, no such devices are currently available that can perform all the functions, including absolute nucleic acid determination, worldwide on-site detection, rapid analysis and real-time results reporting via ubiquitous mobile networks simultaneously with full package and automated means of measurement. In this study, we presented a compact low-cost portable POC automated testing platform with all attributes mentioned above. A disposable self-priming compartmentalization(SPC) microfluidic chip is used to conduct isothermal amplification. The platform also includes a micro-computer controlled heating unit, an inexpensive optical imaging setup, and a mobile device with customized software. It may become a useful tool for the rapid on-site detection of infectious diseases as well as other pathogens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号