首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Microcolumn ion chromatography of inorganic anions has been studied using bovine serum albumin immobilized on silica gel as a stationary phase. Several mobile phase solutions were examined, involving sodium iodide, potassium hydrogen phthalate, 2,6-anthraquinone disulfonate (2,6-AQDS) and sodium salicylate. 2,6-AQDS achieved better separation of the analytes tested. Chloride, nitrate, iodide, thiocyanate and sulphate could be separated within 8 min. Detection limits were in the range of 0.9–2.9 M, corresponding to mass detection limits of 0.18–0.59 pmol. The system was applied to the determination of inorganic anions in environmental water and biological samples.  相似文献   

2.
The inability to separate fluoride, phosphate and sulfate by electrostatic ion chromatography (EIC) was overcome by using an ODS silica column coated with mixed zwitterionic-cationic surfactants as the stationary phase. The best results were obtained using the zwitterionic surfactant, 3-(N,N-dimethylmyristylammonium)-propanesulfonate (C19H41NO3S), and the cationic surfactant, myristyltrimethylammonium, CH3(CH2)13N+(CH3)3, in a 10:1 molar ratio in the column coating solution. With a dilute solution of sodium tetraborate as the eluent the model analyte anions were completely separated in the following elution order: F, HPO42-, SO42-, Cl-, NO2-, Br-, NO3-. The very early elution of phosphate and sulfate is most unusual and is unique to this system. Detection limits better than 1.1 x 10(-4) mM and linear calibration plots up to 7.0 mM were obtained with a suppressed conductivity system.  相似文献   

3.
The inability to separate fluoride, phosphate and sulfate by electrostatic ion chromatography (EIC) was overcome by using an ODS silica column coated with mixed zwitterionic-cationic surfactants as the stationary phase. The best results were obtained using the zwitterionic surfactant, 3-(N,N-dimethylmyristylammonium)-propanesulfonate (C19H41NO3S), and the cationic surfactant, myristyltrimethylammonium, CH3(CH2)13N+(CH3)3, in a 10:1 molar ratio in the column coating solution. With a dilute solution of sodium tetraborate as the eluent the model analyte anions were completely separated in the following elution order: F, HPO4 2–, SO4 2–, Cl, NO2 , Br, NO3 . The very early elution of phosphate and sulfate is most unusual and is unique to this system. Detection limits better than 1.1 × 10–4 mM and linear calibration plots up to 7.0 mM were obtained with a suppressed conductivity system.  相似文献   

4.
A novel bovine serum albumin (BSA)-modified magnesia-zirconia stationary phase was prepared using the sodium salt of cis-(3-methyloxiranyl)phosphonic acid (fosfomycin) as spacer and glutaraldehyde as coupler. Baseline separation of six derivatized amino acids (DNB-Leu, Dansyl-Val, etc.) was achieved on this column using ammonium acetate buffer-isopropanol mobile phase at a flow rate of 1.0 mL/min. The effects of mobile phase composition, eluent pH value, column temperature, and flow rate on the retention and separation of chiral compounds were also investigated. The BSA chiral stationary phase (BSA-CSP) was relatively stable under experimental conditions. The coupling reaction in this method was mild, reliable, and reproducible; thus it was also suitable for the immobilization of various biopolymers with amino groups in the preparation of chromatography stationary phases.  相似文献   

5.
Several aliphatic ionenes (2-6-, 6-6-, 10-6-ionene) have been prepared as ion exchangers for the development of novel high-performance stationary phases for anion chromatography (IC). A macroporous polystyrene/divinylbenzene (PS/DVB) resin with adjusted cation exchange capacity was used as support. Therefore the immobilization of ionenes to polystyrene carriers with remaining positive surface charge became possible for the first time. Strong ion-exchange interactions, resulting in high retention times, between the stationary phase and inorganic as well as organic anionic analytes have been observed. The influence of different ionenes on the retention behaviour during the ion chromatographic separation was investigated. Additionally, partly aromatic and polar ionene backbones were prepared and their retention behaviour as anion exchanger was investigated. The highest number of theoretical plates obtained was about 90.000 per meter. The signal asymmetries were generally lower than obtained for surface functionalized anion exchangers.  相似文献   

6.
7.
Serum albumin, one of the most abundant serum proteins, blocks the expression of other important biomarkers. The objective of this study is to remove serum albumin effectively by using solid-phase extraction (SPE) in microfluidic devices. Photo-polymerized adsorbent as a stationary phase of SPE was used to remove bovine serum albumin (BSA). The adsorption capacity was examined with the effect of pH and concentration in BSA solution, and adjustment of monomer concentration such as hydrophilic 2-acrylamido-2-methyl-1-propanesulfonic acid and acrylamide in the adsorbent. The effect of hydrophobic butyl methacylate on BSA adsorption was also studied. Selective removal in a bicomponent with BSA and bovine gamma-globulin was performed by adjusting the pH as required.  相似文献   

8.
9.
A liquid chromatographic method for the determination of the degree of protein-binding of drugs has been established, using a stationary phase to which bovine serum albumin has been bonded chemically. In a structurally heterogeneous group of compounds, results of the method correlate well with protein-binding data obtained by equilibrium dialysis (r = 0.89, n = 23, p less than 0.001). Within a series of analogous piperazines a good correlation is found (r = 0.981, n = 11, p less than 0.001). The chromatographic method allows automation of the measurement of protein-binding of large series of compounds with protein-binding ranging between 10 and 99%. The method is not expensive and is less time consuming than equilibrium dialysis. Only 1 mg of technical-grade material is required to determine the protein-binding, and radioactive labelling of the material is not necessary.  相似文献   

10.
Wang H  Zou H  Ni J  Kong L  Gao S  Guo B 《Journal of chromatography. A》2000,870(1-2):501-510
A method for the screening and analysis of biologically active compounds in traditional Chinese medicine is proposed. Affinity chromatography using a human serum albumin (HSA) stationary phase was applied to separate and analyze the bioactive compounds from Artemisia capillaris Thunb. Five major peaks and several minor peaks were resolved based on their affinity to HSA, two of them were identified as scoparone (SCO, 6,7-dimethoxycoumarin) and capillarisin (CAP). CAP shows a much higher affinity to HSA than SCO. The effects of acetonitrile concentration, eluent pH, phosphate concentration and temperature on the retention behaviors of several major active components were also investigated, and it was found that hydrophobicity and eluent pH play major roles in changing retention values. The results demonstrate that the affinity chromatography with a HSA stationary phase is an effective way for analyzing and screening biologically active compounds in traditional Chinese medicine.  相似文献   

11.
Summary The chromatographic behavior of twelve dansyl DL amino acids, one D isomer and eleven L isomers on RP18W/UV254, RP18W/F254s, and Sil C18–50 UV254 plates developed with aqueous—organic solutions containing bovine serum albumin (BSA) as chiral complexing agent has been extensively investigated. Enantiomeric resolution is highly dependent on mobile phase pH and ionic strength, and on the concentration of both BSA and organic modifier. All the racemates have been resolved within a development time of 1 h 30 min. The selectivity factors () for the dansyl amino acids have been compared with those from planar chromatography for the corresponding DNP, DNPy, and Fmoc amino acids, and with those of the same dansyl derivatives on a column prepared from BSA bound to silica gel.  相似文献   

12.
A review on the applications of ion chromatography (IC) to the determination of inorganic anions in foodstuffs is presented. The anions were commonly determined in food, i.e., SO3(2-), NO3- and NO2-, and to a lesser extent Cl-, Br-, I-, SO4(2-), IO3-, BrO3- and phosphate, are considered. In comparison with standard methods for the determination of anions in food products, chromatographic methods are rapid, sensitive and precise. They also have the advantage of determining several ions simultaneously. The separation may be achieved by conventional IC, by ion interaction chromatography or by ion exclusion chromatography. IC has also been applied to the determination of Br, I, N and S in foods after oxidation or combustion of samples and conversion into anionic forms.  相似文献   

13.
Liposomes have been used as a stationary phase for column chromatography with an aqueous mobile phase. They were immobilized in the pores of carrier gel beads by two methods: (A) hydrophobic ligands were coupled to the matrix of gel beads, which then were packed into a column and liposomes were applied and became associated with the ligands by hydrophobic interaction; and (B) phospholipids and detergent were dialysed in the presence of gel beads; many of the liposomes that formed in the pores of the beads were sterically immobilized by the gel matrix. Proteoliposomes containing red cell glucose transport protein in the lipid bilayers were immobilized in a column by method A. This column retained D-glucose longer than L-glucose. In contrast to L-glucose, D-glucose was transported into and out of the immobilized liposomes, causing an increased retention. Liposomes with (stearylamine)+ or (phosphatidylserine)- in their lipid bilayers were immobilized by method B and the gel beads were packed into a column. A protein of opposite charge was applied in excess. Under suitable conditions, the protein molecules became close-packed on the liposome surfaces. Ion-exchange chromatographic experiments with proteins showed that these sterically immobilized liposomes were also stable enough to be used as a stationary phase. The loss of lipids was 5-23% in the first run at high protein load and with sodium chloride gradient elution but was lower in subsequent runs. It is proposed that water-soluble molecules can be separated and their interactions with liposome surfaces studied by chromatography on immobilized liposomes in detergent-free aqueous solution. Membrane proteins can be inserted and ligands can be anchored in the lipid bilayers for chromatographic purposes.  相似文献   

14.
Inorganic anions were separated on hydrophobic stationary phases such as triacontyl-functionalized silica. Eluent conditions were examined in detail, and iodate, nitrate, iodide, and thiocyanate could be separated by using aqueous solutions. The effect of the eluent concentration on the retention of analyte anions was examined for a wide range of sodium sulfate concentrations of up to 1 M. The retention factor of hydrophobic anions decreased with increasing sodium sulfate concentration in the lower concentration region, while it increased with increasing sodium sulfate concentration in the higher concentration region. The addition of a small amount of an organic substance such as acetonitrile and tetraethylene glycol increased the retention of iodide and thiocyanate, while the addition of alcohols decreased their retention. Operating at lower temperature also increased the retention of analyte anions. It was expected that inorganic anions were retained on the stationary phase via hydrophobic interactions. The retention mechanism was discussed, considering the results obtained.  相似文献   

15.
The time period covered for this review includes articles published from 1997 to 1999, with the addition of a few classic references. The purpose of the review is to include the most relevant works from each topic area of the determination of inorganic anions by ion chromatography, including new sample pretreatments, new separation methods, new detection systems and the latest applications in the field of environmental, water, foods, etc. samples. Experimental conditions such as stationary phase, eluent, detection mode, as well as matrix are summarized in a table.  相似文献   

16.
普青  何宇雨  袁黎明 《色谱》2020,38(4):484-489
手性介孔材料在手性分离、不对称催化、手性传感等领域具有广泛的应用价值。手性有序无机介孔硅是一类介孔结构高度有序、不含有机成分的手性材料。该文采用D-苯丙氨酸为手性源合成手性有序无机介孔硅(COIMS),将其用聚硅氧烷(OV-1701)稀释后用作固定相制备毛细管气相色谱手性柱,并对该手性柱的分离性能进行了考察,8种手性化合物在该手性柱上得到了拆分。COIMS柱对直链烷烃、醇的分离也表现出良好的选择性。该柱还具有分析时间短、在较高温度下测定稳定等优点,其具有开发成高温手性固定相的潜力。  相似文献   

17.
Auler LM  Silva CR  Bottoli CB  Collins CH 《Talanta》2011,84(4):1174-1179
This work describes the characterization and potential applications of a silica-based anion-exchange phase prepared by a two-step modification process that incorporates a propylpyridinium group. The effects of pH and eluent concentration on anion separation were examined using 150 mm × 3.9 mm HPLC columns packed with the new phase. The mobile phase pH values ranged from 3.8 to 6.6 using phthalic acid/Tris solutions. The best separation was achieved using 2.5 mmol L−1 phthalate/2.4 mmol L−1 Tris solution at pH 4.2 as mobile phase with non-suppressed conductivity detection. The new stationary phase was used for the separation of some inorganic and organic anions showing good resolution. The stability of the silica-based anion exchange phase was also evaluated.Analytical curves, for concentrations ranging from 0.25 to 10 mg L−1 for the inorganic anions chloride, nitrite, bromide and nitrate, showed good linear correlations (r > 0.998). The method was tested with certified rainwater samples. The measured and certified values were in good agreement, indicating that the new phase holds significant promise for the analysis of these anions in environmental samples.  相似文献   

18.
A method for the screening and analysis of biologically active compounds in traditional Chinese medicine is proposed. Affinity chromatography using a human serum albumin (HSA) stationary phase was applied to separate and analyze the bioactive compounds from Artemisia capillaris Thunb. Five major peaks and several minor peaks were resolved based on their affinity to HSA, two of them were identified as scoparone (SCO, 6,7-dimethoxycoumarin) and capillarisin (CAP). CAP shows a much higher affinity to HSA than SCO. The effects of acetonitrile concentration, eluent pH, phosphate concentration and temperature on the retention behaviors of several major active components were also investigated, and it was found that hydrophobicity and eluent pH play major roles in changing retention values. The results demonstrate that the affinity chromatography with a HSA stationary phase is an effective way for analyzing and screening biologically active compounds in traditional Chinese medicine.  相似文献   

19.
T. Takeuchi  T. Miwa 《Chromatographia》1995,40(3-4):159-162
Summary The effects of acetonitrile and bovine serum albumin (BSA) concentrations on the signal intensity and retention behavior of dansylamino acids have been examined by using -cyclodextrin-bonded silica gel as the stationary phase in microcolumn liquid chromatography. Fluorescence intensities of dansylamino acids were enhanced by BSA as a mobile phase additive, e.g., detection limits of dansyl derivatives of L-Ala and L-Phe were improved by a factor of 12–18.  相似文献   

20.
A fast separation of alkali and alkaline earth metal cations and ammonium was carried out by capillary electrochromatography on monolithic octadecylsilica columns of 15 cm length and 100 μm inner diameter using water/methanol mixtures containing acetic acid as mobile phase. On-column contactless conductivity detection was used for quantification of these non-UV-absorbing species. The method was also extended successfully to the determination of small amines as well as of amino acids, and the separation selectivity was optimized by varying the composition of the mobile phase. Detection limits of about 1 μM were possible for the inorganic cations as well as for the small amines, while the amino acids could be quantified down to about 10 μM. The separation of 12 amino acids was achieved in the relatively short time of 10 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号