首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
分子印迹技术在毛细管电色谱中的应用   总被引:2,自引:0,他引:2  
分子印迹技术是制备具有分子识别功能聚合物,即分子印迹聚合物(MIPs)的一种新技术;毛细管电色谱(CEC)是一个具有发展前途的色谱新技术。将分子印迹技术和毛细管电色谱两种新技术相结合,优势互补,具有极大的发展潜力。本文对分子印迹技术在毛细管电色谱中的应用,以及各类MIPs-CEC毛细管柱的制备方法进行了较为全面的综述,引用文献52篇。  相似文献   

2.
This review represents a summary of recent progress in open-tubular capillary electrochromatography (OT-CEC) for chiral and achiral separations. The OT-CEC approach is an alternative to packed-CEC that could eliminate the problems associated with retaining frits and silica particles. In OT-CEC, the stationary phase is immobilized on the inner walls of the capillary. Preparation of the stationary phase is critical for OT-CEC. The preparation methods for capillary columns include (i) adsorption, (ii) covalent bonding and/or cross-linking, (iii) porous layers, (iv) chemical bonding after etching, (v) sol-gel, and (vi) molecular imprinting. Major developments, potential applications, technical difficulties and advantages associated with these wall coatings in OT-CEC are presented. In addition, the coupling of OT-CEC with mass spectrometry (MS) is briefly reviewed. Several applications of this hyphenated technique for analytical separations are also summarized.  相似文献   

3.
The applicability of capillary electrochromatography (CEC) using packed capillary column to enantiomer separations was investigated. As chiral stationary phases, OD type packing materials of 5 and 3 microm particle diameters, originally designed for conventional high-performance liquid chromatography (HPLC) were employed. The chiral packing materials were packed by a pressurized method into a 100 microm I.D. fused-silica capillary. Several racemic enantiomers, such as acidic, neutral and basic drug components, were successfully resolved, typically by using acidic or basic solutions containing acetonitrile as mobile phases. The separation efficiencies for some enantiomers in the chiral CEC system using the 5 microm OD type packing were superior to those obtained in HPLC using chiral packings. The plate heights obtained for several enantiomers were 8-13 microm or the reduced plate height of 1.6-2.6, which indicates the high efficiency of this chiral CEC system.  相似文献   

4.
A novel tentacle-type polymer stationary phase covalently modified with branched polyethyleneimine (PEI) was developed for peptides and proteins separations by open-tubular CEC (OT-CEC). The preparation procedure included the silanization of capillary inner wall, in situ graft polymerization and PEI functionalization. A wrinkly polymer surface of multitudinous steric amine groups was evenly formed on the capillary inner wall, and anodic EOF could be gained within a wide pH range of 2.5-7.5. The electroosmotic mobility was examined for its dependence on pH as well as PEI concentrations. Good repeatability was gained with RSD for the migration time of EOF marker within 4.8% and satisfactory chemical stability was validated. Due to the existence of amine groups on the surface of tentacle-type polymer stationary phase, the silanol effect that occurs between the positively charged biomolecules and the silanols of the capillary column was greatly suppressed. Compared with a monolayer-coating capillary, seven enkephalin-related peptides were well resolved on the PEI-bonded column with high efficiencies. Favorable separations of peptides and proteins with high column efficiencies were obtained in 144,000-189,000 and 97,000-170,000 plates/m. Branched PEI-bonded tentacle-type polymer stationary phase has been proven to afford satisfactory retention and resolution of peptides and proteins.  相似文献   

5.
Novel polyelectrolyte multilayer (PEM) coatings for enhanced protein separations in open tubular CEC (OT-CEC) are reported. Use of four cationic polymers (poly-L-lysine, poly-L-ornithine, poly-L-lysine-serine, and poly-L-glutamic acid-lysine), and three anionic molecular micelles, sodium poly(N-undecanoyl-L-leucyl-alaninate) (poly-L-SULA), sodium poly(N-undecanoyl-L-leucyl-valinate) (poly-L-SULV), and sodium poly(undecylenic sulfate) (poly-SUS) were investigated in PEM coatings for protein separations. The simultaneous effects of cationic polymer concentration, number of bilayers, temperature, applied voltage, and pH of the BGE on the separation of four basic proteins (alpha-chymotrypsinogen A, lysozyme, ribonuclease A, and cytochrome c) were analyzed using a Box Behnken experimental design. The influence of NaCl on the run-to-run reproducibility was investigated for PEM coatings containing each cationic polymer. All coatings exhibited excellent reproducibilities with a %RSD of the EOF less than 1% in the presence of NaCl. Optimal conditions were dependent on both the cationic and anionic polymers used in the PEM coatings. Poly-L-glutamic acid-lysine produced the highest resolution and longest migration time. The use of molecular micelles to form PEM coatings resulted in better separations than single cationic coatings. Chiral poly-L-SULA and poly-L-SULV resulted in higher protein resolutions as compared to the achiral, poly-SUS. Furthermore, the use of poly-L-SULV reversed the elution order of lysozyme and cytochrome c when compared to poly-L-SULA and poly-SUS.  相似文献   

6.
An adamantyl (ADM)-functionalized monolithic stationary phase was newly synthesized by a single-step copolymerization of 1-adamantyl-(α-trifluoromethyl) acrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid in order to prevent the peak tailing of basic solutes in capillary electrochromatography and was compared with butyl methacrylate (BMA)-based one. The ADM structure shields the negatively charged groups on the surface of monolith from basic solutes, resulting in better peak shapes than BMA-based monolithic stationary phase. As the monomers ratio decreased, the monolithic column had lower retention and higher column efficiency which was likely due to lower phase ratio and smaller globule size of monolith, respectively. The ADM-functionalized monolithic columns exhibited a good repeatability and reproducibility of column preparation with relative standard deviation values below 9% in the studied chromatographic parameters.  相似文献   

7.
A review on the advantages, peculiarities, and the potential of enantioselective capillary electrochromatography (CEC) in nonaqueous media is presented. Some fundamentals on CEC with particular focus on enantioselective CEC are discussed. The strategies, concepts, preferentially utilized chiral selectors and column technologies that have been utilized to succeed in highly efficient enantiomer separations by nonaqueous CEC are described thoroughly.  相似文献   

8.
The recognition mechanism of molecularly imprinted polymer (MIP) in capillary electrochromatography (CEC) is complicated since it possesses a hybrid process, which comprises the features of chromatographic retention, electrophoretic migration and molecular imprinting. For an understanding of the molecular recognition of MIP in CEC, a monolithic MIP in a capillary with 1,1'-binaphthyl-2,2'-diamine (BNA) imprinting was prepared by in situ copolymerization of imprinted molecule, methacrylic acid and ethylene glycol dimethacrylate in porogenic solvent, a mixture of toluene-isooctane. Strong recognition ability and high column performance (theory plates was 43,000 plates/m) of BNA were achieved on this monolithic MIP in CEC mode. In addition, BNA and its structural analogue, 1,1'-bi-2, 2'-naphthol, differing in functional groups, were used as model compounds to study imprinting effect on the resultant BNA-imprinted monolithic column, a reference column without imprinting of BNA and a open capillary. The effects of organic modifier concentration, pH value of buffer, salt concentration of buffer and column temperature on the retention and recognition of two compounds were investigated. The results showed that the molecular recognition on MIP monolith in CEC mode mainly derived from imprinting cavities on BNA-imprinted polymer other than chromatographic retention and electrophoretic migration.  相似文献   

9.
Racemic mixtures of tryptophan and dinitrobenzoyl leucine have been successfully resolved by capillary electrochromatography (CEC) using the macrocyclic antibiotic teicoplanin, covalently bonded to a 5 microns silica support. Modification of a previously published packing procedure was required to pack reliable capillaries, capable of performing enantiomeric separations. Good levels of enantioselectivity were obtained in all cases, with optimised separations being performed in less than 6 min. Retention times, resolution and reproducibility are discussed.  相似文献   

10.
Enantiomers of bioactive molecules often differ in potency, toxicity, metabolism, and pharmacological actions. Capillary electrochromatography (CEC) is an emerging separation technique being investigated for use in chiral separations. CEC is a hybrid of HPLC and CE. CEC combines the electrophoretic mobility of CE with the partitioning mechanisms of HPLC. In this overview, several resolution mechanisms commonly used in CEC and the main parameters influencing the selectivity of the chiral separation will be discussed. Current applications of CEC in chiral separations of pharmaceuticals will be provided for each type of resolution mechanism. Finally, the advantages and limitations of CEC will be described, followed by the future outlook for CEC.  相似文献   

11.
Eeltink S  Svec F  Fréchet JM 《Electrophoresis》2006,27(21):4249-4256
Open-tubular columns for CEC separations having inner-wall coated with a thin layer of porous monolithic polymer have been studied. A two-step process including (i) UV-initiated polymerization leading to a layer of porous poly(butyl methacrylate-co-ethylene dimethacrylate), and (ii) UV-initiated grafting of ionizable monomers appear to be well suited for the preparation of these columns. The thickness of the porous polymer layer is controlled by the percentage of monomers in the polymerization mixture and/or length of the irradiation time. The layer thickness significantly affects retention, efficiency, and resolution in open-tubular CEC. Under optimized conditions, column efficiencies up to 400,000 plates/m can be achieved. Use of higher temperature and application of pressure enables a significant acceleration of the open-tubular CEC separations.  相似文献   

12.
Spherical molecularly imprinted polymer particles obtained via precipitation polymerization, were introduced as a pseudostationary phase in capillary electrophoresis (CE) to study molecular recognition. Analyses were performed via a partial filling technique using (+)-ephedrine-imprinted microspheres (100-200 nm) which were polymerized from methacrylic acid and 1,1,1-Tris(hydroxymethyl)propanetrimethacrylate using acetonitrile as the solvent. The influence of pH and the modifier content on the separation was investigated. A 0.1% w/v suspension in an aqueous 10 mM phosphate buffer (pH 2.5 with 40% acetonitrile) was hydrodynamically injected into the CE system (80% of the effective capillary length) and led to full baseline separation of racemic ephedrine within 10 min.  相似文献   

13.
The review summarizes recent developments in enantioseparations by capillary electrochromatography (CEC). Selected fundamental aspects of CEC are discussed in order to stress those features which may allow the success of this technique in the competitive field of enantioseparations. In addition, the comparative characteristics of the different modes of chiral CEC and the stationary phases are presented. The effects of the characteristics of the stationary and liquid phases and operational conditions on the separation results are discussed. Finally, some future trends are briefly addressed.  相似文献   

14.
岳春月  丁国生  唐安娜 《色谱》2013,31(1):10-14
依据分子印迹技术(MIT)制备的分子印迹聚合物(MIP)颗粒对模板分子及其结构类似物具有特异性识别和选择性吸附作用,同时具有较大的比表面积和快速的传质动力学特性,因而被广泛用作液相色谱固定相和固相萃取材料。将MIP颗粒作为固定相应用于毛细管电色谱(CEC),结合了CEC的快速、高效和MIP的高亲和性、高选择性的特点,成为分析科学领域最具有发展前景的分离技术之一。MIP颗粒在CEC领域有几种不同的应用形式: 作为填充材料填充到毛细管柱中;作为嵌入材料嵌入到毛细管柱内部不同基质的骨架中;作为准固定相添加到CEC运行缓冲溶液中。本文综述了近几年MIP颗粒在CEC领域应用的发展,对该领域今后的发展前景进行了展望。  相似文献   

15.
16.
Pacáková V  Coufal P  Stulík K  Gas B 《Electrophoresis》2003,24(12-13):1883-1891
The importance of capillary electrophoresis (CE), capillary electrochromatography (CEC), and ion chromatography (IC) in inorganic ion analyses is outlined. Methods for improving the reliability of the CE measurements are briefly described. Selectivity optimization in CE analyses of inorganic cations and anions is discussed. Using the Peakmaster program, CE system peaks (system zones, eigenmobilites) and some important CE parameters, such as effective mobilities, electromigration dispersion, indirect UV, and direct conductivity signals, are predicted and compared with experimental analyses.  相似文献   

17.
A series of micro-monolithic columns with different porosities were prepared for capillary electrochromatography (CEC) by in-situ copolymerization of butyl methacrylate, ethylene glycol dimethacrylate, and 2-acrylamido-2-methyl-1-propane-sulfonic acid in the presence of a porogen in fused-silica capillaries of 100 microm I.D. Different column porosities were obtained by changing the ratios of monomers to porogenic solvents. Columns were investigated and evaluated under both pressure-driven (high-performance liquid chromatography, HPLC) and electro-driven (capillary electrochromatography, CEC) conditions. Each column exhibited different efficiency and dependency on flow velocity under electro-driven conditions. Abnormally broad peaks for some relatively bulky molecules were observed. Possible explanations are discussed. The differences in column efficiency and retention behavior between the two eluent-driven modes were studied in detail. In addition, other column properties, such as morphology, porosity, stability and reproducibility, were extensively tested.  相似文献   

18.
The work done during the past decade in order to adapt molecularly imprinted polymers (MIPs) to the capillary format and subsequently use these highly selective matrices for capillary electrochromatography (CEC) are reviewed in this article. MIPs are prepared utilizing a templated polymer synthesis where the template addresses the selectivity of the resulting polymer. These polymers possess binding characteristics that are comparable to the biological antibodies. Due to the polyclonality of the binding sites in the MIP, the separation result in severe peak broadening and tailing when performed in the isocratic mode. This was seen early in the development of MIPs as selective stationary phases in liquid chromatography (LC). As a mean of decreasing these problems, much effort was put into adapting the MIP to fit in CEC systems, that offers an efficiency that is superior to that in LC. Aiming to increase the efficiency of the MIP-CEC systems, different MIP formats have been developed that can be divided into three conceptually different categories, i.e., the monolithic, the microparticle and the coating. The strive for MIP formats that can be used in small bore capillaries has led to the development of MIP formats applicable to miniaturized systems approaching the chip format. Although prepared in order to perform MIP-CEC mediated separations, these formats can be used in a broad range of applications were the characteristics of the MIP, e.g. stability, selectivity and cost efficiency, could offer an interesting solution to cover the needs.  相似文献   

19.
Summary The novel application of CE using non-aqueous media has been studied for the separation of a range of acidic compound types. This enabled the first quantitative assay by CE employing non-aqueous media to be performed. Separation selectivity manipulation for closely related species was achieved through variation of organic solvent types and composition, ionic strength changes, alteration of pH* values and the addition of cyclodextrin additives soluble in organic solvents. This offers a greater range of possibilities during method development than use of aqueous buffer. The generation of low operating currents permitted rapid, highly efficient and selective separations to be achieved by applying high field strengths across short capillaries. Optimised rinsing and capillary regenerating procedures were devised which allowed highly repeatable separations to be achieved with migration time repeatability below 1% RSD. Use of internal standards also allowed 1% RSD values to be obtained for injection precision. Routine operating effects were assessed and it was observed that stacking effects remain important in non-aqueous CE. Also, optimal separations are obtained when the samples are diluted in the pure solvent used to prepare the electrolyte. The application range of non-aqueous CE was appreciably extended to include acidic drugs, dyes, surfactants and preservatives.  相似文献   

20.
Several chiral drugs, promethazine, carteolol, celiprolol, and albuterol, were resolved with vancomycin as the chiral stationary phase by pressurized capillary electrochromatography (pressurized CEC) and capillary HPLC. The effects of pressure and electrical field strength on efficiency, resolution, and capacity factor in pressurized CEC were investigated. A mathematical model describing the relationship of capacity factor in pressurized CEC with voltage, pressurized flow velocity, electroosmotic mobility, and electrophoretic mobility was established, which was in good agreement with the experimental data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号