首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid method was developed for the analysis of the insecticide (A) diazinon (O,O-diethyl O-2-isopropyl-6-methylpyridimidinyl) phosphorothioate, its metabolites (B) diazoxon (O,O-diethyl O-2-isopropyl-6-methylpyridimidinyl) phosphate, and (C) 2-isopropyl-6-methyl-4-pyrimidinol, the insecticide (D) permethrin [3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid (3-phenoxyphenyl)methylester], its metabolites (E) m-phenoxybenzyl alcohol, and (F) m-phenoxybenzoic acid, the insect repellent (G) DEET (N,N-diethyl-m-toluamide), and its metabolites (H) m-toluamide and (I) m-toluic acid in rat plasma and urine. The method is based on using C18 Sep-Pak cartridges (Waters Corporation, Milford, Mass., U.S.A.) for solid phase extraction and high performance liquid chromatography with a reversed phase C18 column, and absorbance detection at 230 nm for compounds A, B, and C, and at 210 nm for compounds D-I. The compounds were separated using a gradient from 1% to 99% acetonitrile in water (pH 3.0) at a flow rate ranging between 1 and 1.7 mL/min in a period of 17 min. The limits of detection were ranged between 20 and 100 ng/mL, while limits of quantification were 80-200 ng/mL. The relationship between peak areas and concentration was linear over a range of 100-1000 ng/mL. This method was applied to determine the above insecticides and their metabolites following dermal administration in rats.  相似文献   

2.
A rapid method was developed for the analysis of the insecticide (A) diazinon (O,O-diethyl O-2-isopropyl-6-methylpyridimidinyl) phosphorothioate, its metabolites (B) diazoxon (O,O-diethyl O-2-isopropyl-6-methylpyridimidinyl) phosphate, and (C) 2-isopropyl-6-methyl-4-pyrimidinol, the insecticide (D) permethrin [3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid (3-phenoxyphenyl)methylester], its metabolites (E) m-phenoxybenzyl alcohol, and (F) m-phenoxybenzoic acid, the insect repellent (G) DEET (N,N-diethyl-m-toluamide), and its metabolites (H) m-toluamide and (I) m-toluic acid in rat plasma and urine. The method is based on using C18 Sep-Pak cartridges (Waters Corporation, Milford, Mass., U.S.A.) for solid phase extraction and high performance liquid chromatography with a reversed phase C18 column, and absorbance detection at 230 nm for compounds A, B, and C, and at 210 nm for compounds D–I. The compounds were separated using a gradient from 1% to 99% acetonitrile in water (pH 3.0) at a flow rate ranging between 1 and 1.7 mL/min in a period of 17 min. The limits of detection were ranged between 20 and 100 ng/mL, while limits of quantification were 80–200 ng/mL. The relationship between peak areas and concentration was linear over a range of 100–1000 ng/mL. This method was applied to determine the above insecticides and their metabolites following dermal administration in rats.  相似文献   

3.
This study reports on the development of a rapid and simple method for the determination of the antinerve agent drug pyridostigmine bromide (3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) (PB), its metabolite N-methyl-3-hydroxypyridinium bromide, nicotine (S-1-methyl-5-(3-pyridyl)-2-pyrrolidine), and its metabolites nornicotine (2-(3-pyridyl)pyrrolidine) and cotinine (S-1-methyl-5-(3-pyridyl)-2-pyrrolidone) in rat plasma and urine. The compounds are extracted and eluted by methanol and acetonitrile using C18 Sep-Pak cartridges and separated using high-performance liquid chromatography by a gradient of methanol, acetonitrile, and water (pH 3.2) at a flow rate of 0.8 mL/min in a period of 14 min. UV detection was at 260 nm for nicotine and its metabolites and at 280 nm for PB and its metabolite. The limits of detection ranged between 20 and 70 ng/mL, and the limits of quantitation were 50-100 ng/mL. The average percent recovery of five spiked plasma samples were 85.7 +/- 7.3%, 80.4 +/- 5.8%, 78.9 +/- 5.4%, 76.7 +/- 6.4%, and 79.7 +/- 5.7% and for urine were 85.9 +/- 5.9%, 75.5 +/- 6.9%, 82.6 +/- 7.9%, 73.6 +/- 5.9%, and 77.7 +/- 6.3% for nicotine, nornicotine, cotinine, PB, and N-methyl-3-hydroxypyridinium bromide, respectively. The calibration curves for standard solutions of the compounds of peak areas and concentration are linear for a range between 100 and 1,000 ng/mL. This method is applied in order to analyze the previously mentioned chemicals and metabolites following their oral administration in rats.  相似文献   

4.
This study reports a simple and rapid high-performance liquid chromatographic (HPLC) method for the determination of the insecticide diazinon (O,O-diethyl-O[2-isopropyl-6-methylpyridimidinyl] phosphorothioate), its metabolites diazoxon (O,O-diethyl-O-2-isopropyl-6-methylpyridimidinyl phosphate) and 2-isopropyl-6-methyl-4-pyrimidinol, the insecticide chlorpyrifos (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphorothioate) and its metabolites chlorpyrifos-oxon (O,O-diethyl-O[3,5,6-trichloro-2-pyridinyl] phosphate), and TCP (3,5,6-trichloro-2-pyridinol) in rat plasma and urine samples. The method is based on using C18 Sep-Pak cartridges for solid-phase extraction and HPLC with a reversed-phase C18 column and programmed UV detection ranging between 254 and 280 nm. The compounds are separated using a gradient of 1% to 80% acetonitrile in water (pH 3.0) at a flow rate ranging between 1 and 1.5 mL/min in a period of 16 min. The limits of detection ranged between 50 and 150 ng/mL, and the limits of quantitation were 100 to 200 ng/mL. The average percentage recovery of five spiked plasma samples were 86.3 +/- 8.6, 77.4 +/- 7.0, 82.1 +/- 8.2, 81.8 +/- 8.7, 73.1 +/- 7.4, and 80.3 +/- 8.0 and from urine were 81.8 +/- 7.6, 76.6 +/- 7.1, 81.5 +/- 7.9, 81.8 +/- 7.1, 73.7 +/- 8.6, and 80.7 +/- 7.7 for diazinon, diazoxon, 2-isopropyl-6-methyl-4-pyrimidinol, chlorpyrifos, chlorpyrifos-oxon, and TCP, respectively. The relationship between the peak area and concentration was linear over a range of 200 to 2,000 ng/mL. This method was applied in order to analyze these chemicals and metabolites following dermal administration in rats.  相似文献   

5.
A screening method has been developed for the determination of 23 organochlorine pesticides (OCPs) and 3-pyrethroid metabolities [cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, cis-3-(2,2-dibromovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid and 3-phenoxybenzoic acid] from human urine. OCPs were directly detected in urine samples while pyrethroid metabolites required acid-induced hydrolysis to convert their conjugates into free acids; all compounds were then cleaned-up/preconcentrated using solid phase extraction. Determination and quantitation was achieved by gas chromatography with a mass spectrometer detector operating in selected ion monitoring mode. Limits of detection varied between 0.1 and 0.3 ng/mL with linear ranges from 0.3 to 700 ng/mL; the precision of the method was high (4.3-7.2%). Recoveries of all analytes from urine samples fortified at levels of 30 ng/mL for each OCP and 15 ng/mL for each pyrethroid metabolite ranged from 88 to 101% (captan gave the lowest recovery). The results obtained from the analysis of real urine samples show the suitability of the proposed method for monitoring people exposed to organochlorine and pyrethroid pesticides.  相似文献   

6.
Metabolites of synthetic pyrethroids such as cis-3-(2,2-dibromovinyl)-2,2-di-methylcyclo-propane-1-carboxylic acid, cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid), 3-phenoxybenzoic acid (3-PBA), and 4-fluoro-3-PBA are biomarkers for exposure to phenothrin, tetramethrin, cyfluthrin, cypermethrin, deltamethrin, and permethrin. In this study, the pyrethroid metabolites in workers’ urine samples were monitored for the first time with a novel sample pretreatment process combining hollow fiber liquid phase microextraction (HF-LPME) and in-syringe derivatization (ISD) followed by gas chromatography–electron capture detector (GC-ECD) analysis. A micro-syringe pre-filled with derivatizing agents and syringe needle connected to an extracting solvent impregnated hollow fiber segment was used as the LPME probe. Pyrethroid metabolites were extracted and enriched simultaneously from urine samples by HF-LPME sampling and acid hydrolysis at 70 °C for 10 min. After sampling, the ISD was performed by mixing the extracting solution and derivatizing agents through plunger movements, followed by GC-ECD analysis. Parameters influencing the HF-LPME efficiency and ISD were investigated and optimized. Under optimum conditions, the method provided enrichment factors of 69.8–154.6, repeatability from 5.0 to 12% (n = 5), and good linearity (R 2 = 0.9980–0.9998) for interested analytes spiked in urine samples. The method detection limits ranged from 1.6 to 17 ng/mL. A comparison was performed between the proposed method and conventional methods. The proposed method was applied to analyze pyrethroid metabolites in the urine samples collected from workers of pesticide formulation plants. The results suggested that the proposed HF-LPME coupled ISD method was a rapid, simple, efficient, and eco-friendly technique in the biomonitoring of metabolites of pyrethroids in workers’ urine.  相似文献   

7.
Pyrethroid insecticides are applied in the residential environment, as well as in agricultural crops, for insect control purpose. We developed and validated an accurate, sensitive, and reproducible analytical method to simultaneously detect seven pyrethroid metabolites, namely, 3‐(2,2‐dichlorovinyl)‐2,2‐dimethyl‐(1‐cyclopropane) carboxylic acid, 3‐(2,2‐dibromovinyl)‐2,2‐dimethyl‐(1‐cyclopropane) carboxylic acid, 3‐phenoxybenzoic acid, 4‐fluoro‐3‐phenoxybenzoic acid, 2‐methyl‐3‐phenylbenzoic acid, 4‐chloro‐α‐isoproply benzeneacetic acid, and 3‐(2‐chloro‐3,3,3‐trifluoroprop‐1‐enyl)‐2,2‐dimethylcyclopropanecarboxylic acid, in human urine. This method employs deconjugation with enzyme, SPE using Agilent C18 cartridges on a RapidTrace SPE workstation, derivatization using hexafluoro isopropanol and N,N′‐diisopropylcarbodiimide, and compounds separation and identification on GC–MS. The detection limits of seven metabolites were 0.02–0.08 ng/mL in urine. The recoveries of seven metabolites were 81–104%, 85–99%, and 83–99% in urine specimens fortified at 0.1, 0.4, and 3.2 ng/mL concentrations, respectively. The overall coefficient of variation was 4.3–10.8% in two quality control specimens which were repeatedly measured during a period of 2 months. This method was applied to urine samples collected from children living in Boston, MA. The median concentrations of six detected pyrethroid metabolites ranged from 0.06 to 0.86 ng/mL in urine.  相似文献   

8.
An analytical method was developed to measure cis-permethrin and trans-permethrin in different biological rat matrices and fluids (whole blood, red blood cells, plasma, brain, liver, muscle, testes, kidneys, fat and faeces). The method was also suitable for the simultaneous quantification of their associated metabolites [cis-3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid (cis-DCCA), trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid (trans-DCCA) and 3-phenoxybenzoic acid (3-PBA)] in blood (whole blood, red blood cells, plasma) and liver. The target analytes were derivatised in samples using a methanolic/hydrochloric acid solution and then extracted with toluene. The analysis was performed by gas chromatography, and detection using ion trap tandem mass spectrometry. The selectivity obtained for complex matrices such as rat organs allowed the use of a purification step to be avoided for most of the matrices investigated. In the case of fat, where permethrin is suspected to accumulate, a dedicated purification step was developed. In fluids, the limits of quantification were at the 50 ng/mL level for the parent compounds and 3-PBA and at 25 ng/mL for cis-DCCA and trans-DCCA. For solid matrices excluding fat, the limits of quantification ranged from 50 ng/g for muscle to 100 ng/g for brain and testes for both cis-permethrin and trans-permethrin. The extraction recoveries ranged primarily between 80 and 120 % for the matrix tested. The stability of blood samples was tested through the addition of 1 % v/v formic acid. The methods developed were applied in a toxicokinetic study in adult rats. cis-Permethrin and the metabolites were detected in all corresponding matrices, whereas trans-permethrin was detected only in blood, plasma and faeces.  相似文献   

9.
Anastrozole (2,2'-[5-(1H-1,2,4-triazol-1-ylmethyl)-1.3-phenylene]bis(2-methylpropionitrile)) and exemestane (6-methylenandrostan-1,4-diene-3,17-dione) are therapeutically used to treat hormone-sensitive breast cancer in postmenopausal women. For doping purposes they may be used to counteract adverse effects of an extensive abuse of anabolic androgenic steroids (gynaecomastia) and to increase plasma testosterone concentrations. Excretion study urine samples and spot urine samples from women suffering from metastatic breast cancer, being treated with anastrozole or exemestane, were collected and analyzed to develop/optimize a detection system for anastrozole and exemestane to allow the identification of athletes who do not comply with the internationally prohibited use of these cancer drugs. The assay was based on liquid-liquid extraction after enzymatic hydrolysis following liquid chromatography/tandem mass spectrometry (LC/MS/MS). Anastrozole, exemestane and its main metabolite (17-dihydroexemestane) were identified in urine by comparison of mass spectra and retention times with respective reference substances. An assay validation for the analysis of anastrozole and exemestane was performed regarding lower limits of detection (anastrozole: 0.02 ng/mL; exemestane: 3.1 ng/mL; dihydroexemestane: 0.5 ng/mL), interday precisions (6.6-11.1%, 4.9-9.1% and 5.6-8.3% for low [10 ng/mL], medium [50 ng/mL] and high [100 ng/mL] concentration) and recoveries (ranged from 85-97%).  相似文献   

10.
A rapid and sensitive method was developed for the screening, quantification and confirmation of ethyl glucuronide (EG) and ethyl sulfate (ES) as biomarkers for alcohol administration to racehorses using liquid chromatography coupled on-line with triple quadrupole tandem mass spectrometry. Urine sample aliquots (0.1 mL) were pre-treated by protein precipitation. Separation of EG and ES was achieved on an Ultra PFP column. Isocratic elution with a flush step was performed using 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B). Analysis was performed by negative electrospray ionization in multiple reaction monitoring mode. The retention times for EG and ES were 1.7 +/- 0.30 and 3.4 +/- 0.30 min, respectively. The internal standard used was d(5)-ethyl glucuronide with a retention time of 1.7 +/- 0.30 min. The entire separation was completed in <5 min. The limit of detection (LOD) and of quantification (LOQ) for both analytes were 100 ng/mL (S/N > or =3) and 500 ng/mL, respectively. The limit of confirmations (LOC) for EG and ES were 500 ng/mL and 1.0 microg/mL, respectively. The assay was linear over a concentration range of 0.5-100 microg/mL (r(2) > 0.995). Intra- and inter-day accuracy and precision were less than 15%. The analytes were stable in urine for 24 h at room temperature, 10 days at 4 degrees C and 21 days at -20 degrees C and -70 degrees C. Ion suppression or enhancement due to matrix effect was negligible. The measurement uncertainty was <14% for EG and <25% for ES. This method was successfully used for the quantification of EG and ES in urine samples following alcohol administration to research horses and for screening and confirmation of EG and ES in urine samples obtained from racehorses post-competition. The method is simple, rapid, inexpensive, and reliably reproducible.  相似文献   

11.
采用固相支撑液液萃取-超高效液相色谱-串联质谱(SLE-UPLC-MS/MS)技术建立了生物样本血液、尿液和肝组织中地高辛(DG)及其3种代谢物的分析方法。生物样本经匀浆、蛋白沉淀后,通过含有硅藻土的固相支撑液液萃取(SLE)柱净化富集,经洗脱、定容后进行LC-MS/MS分析。结果表明,血液基质中,地高辛在0.1~100 ng/mL浓度范围内线性关系良好;肝脏和尿液基质中,地高辛在0.2~100 ng/mL浓度范围内线性关系良好,地高辛的3种代谢物在0.5~100 ng/mL浓度范围内线性关系良好,3个浓度水平(10, 50和100 ng/mL)的加标回收率为60.5%~95.6%,基质效应80.7%~113.6%,日内、日间相对标准偏差(RSD)均小于13%,检出限为0.1~0.5 ng/mL。所建立的方法可用于生物样本中地高辛及其代谢物的定性定量分析。  相似文献   

12.
We developed an isotopic dilution high-performance liquid chromatography (HPLC)/tandem mass spectrometer (MS/MS) method to rapidly and accurately quantify nine metabolites of several classes of pesticide in 1 mL human urine specimens. The analytes covered in the method are two organophosphate (OP) pesticide metabolites: 3,5,6-trichloro-2-pyridinol (TCPy), 2-isopropyl-6-methyl-4-pyrimidinol (IMPY); three synthetic pyrethroid metabolites: 3-phenoxy benzoic acid (3-PBA), 4-fluoro-3-phenoxybenzoic acid (4-F-3-PBA) and trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-1(1-cyclopropane) carboxylic acid (t-DCCA); three herbicide metabolites: 2,4-dichlorophenoxyacetic acid (DCPAA), 2,4,5-trichlorophenoxyacetic acid (TCPAA) and atrazine mercapturate; and one insect repellent: N,N-diethyl-meta-toluamide (DEET). The analytes are first deconjugated by incubating with acetate/β-glucuronidase buffer at 37°C for 17 h. The deconjugated analytes are extracted and concentrated from the urine matrix using solid-phase extraction cartridges, separated through C18 reversed phase HPLC, and analysed on MS/MS. The MS/MS was operated in positive and negative electrospray ionisation switch mode. Two ions from each analyte and one from each labelled internal standard are monitored for quantification and confirmation. The limit of detections (LODs) for all the analytes are in the low parts-per-trillion (0.05 ng/mL) except TCPy where it was 0.5 ng/mL) with a wide linear range (0.05 up to 40 ng/mL) and provides high accuracy (recoveries: 90–118%) and high precision (coefficient of variation <15%). The method accuracy was also verified by the analysis of proficiency testing urine samples. We analysed 101 urine samples for a recent California study cohort, and detection frequencies ranged from ~100% to 0%: 3-PBA (98%), IMPY (91%), TCPy, (89%), DCPAA (66%), 4-F-3-PBA (11%), TCPAA (0%).  相似文献   

13.
When cocaine is smoked, a pyrolytic product, methyl ecgonidine (anhydroecgonine methyl ester), is also consumed with the cocaine. The amount of methyl ecgonidine formed depends on the pyrolytic conditions and composition of the illicit cocaine. This procedure describes detection of cocaine and 10 metabolites--cocaethylene, nor-cocaine, nor-cocaethylene, methyl ecgonine, ethyl ecgonine, benzoylecgonine, nor-benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine and ecgonine--in blood and urine. In addition, the detection of pyrolytic methyl ecgonidine and three metabolites--ecgonidine (anhydroecgonine), ethyl ecgonidine (anhydroecgonine ethyl ester) and nor-ecgonidine (nor-anhydroecgonine)--are included. The newly described metabolites, ethyl ecgonidine and nor-ecgonidine, were synthesized and characterized by gas chromatography-mass spectrometry (GC-MS). All 15 compounds were extracted from 3 mL of blood or urine by solid-phase extraction and identified by a GC-MS method. The overall recoveries were 49% for methyl ecgonine, 35% for ethyl ecgonine, 29% for ecgonine and more than 83% for all other drugs. The limits of detection were between 0.5 and 4.0 ng/mL except for ecgonine, which was 16 ng/mL. Linearity for each analyte was established and in all cases correlation coefficients were 0.9985-1.0000. The procedure was applied to examine the concentration profiles of analytes of interest in post-mortem (PM) blood and urine, and in urine collected from living individuals (LV). These specimens previously were shown to be positive for the cocaine metabolite, benzoylecgonine. Ecgonidine, the major metabolite of methyl ecgonidine, was present in 77% of PM and 88% of the LV specimens, indicating smoking as the major route of cocaine administration. The new pyrolytic metabolites, ethyl ecgonidine and nor-ecgonidine, were present in smaller amounts. The urine concentrations of nor-ecgonidine were 0-163 ng/mL in LV and 0-75 ng/mL in PM specimens. Ethyl ecgonidine was found only in PM urine at concentrations 0-39 ng/mL. Ethanol-related cocaine metabolites, ethyl ecgonine or cocaethylene, were present in 69% of PM and 53% of cocaine-positive LV specimens, implying alcohol consumption with cocaine use. The four major metabolites of cocaine--benzoylecgonine, ecgonine, nor-benzoylecgonine and methyl ecgonine--constituted approximately 88 and 97% of all metabolites in PM and LV specimens, respectively. The concentrations of nor-cocaine and nor-cocaethylene were consistently the lowest of all cocaine metabolites. At benzoylecgonine concentrations below 100 ng/mL, ecgonine was present at the highest concentrations. In 20 urine specimens, benzoylecgonine and ecgonine median concentrations (range) were 54 (0-47) and 418 ng/mL (95-684), respectively. Therefore, detection of ecgonine is advantageous when benzoylecgonine concentrations are below 100 ng/mL.  相似文献   

14.
A liquid chromatography/mass spectrometry method, for rapid determination of five cytochrome P450 (CYP) probe drugs and their relevant metabolites in human plasma and urine, is described. The five specific probe substrates/metabolites, caffeine/paraxanthine (CYP1A2), tolbutamide/4-hydroxytolbutamide/carboxytolbutamide (CYP2C9), omeprazole/5-hydroxyomeprazole (CYP2C19), debrisoquine/5-hydroxydebrisoquine (CYP2D6) and midazolam/1'-hydroxymidazolam (CYP3A), together with the internal standards (phenacetin and paracetamol), in plasma and urine, were extracted using solid-phase extraction. The chromatography was performed using a C18 column with an isocratic mobile phase consisting of acetonitrile and 0.1% formic acid in water (70:30). The triple-quadrupole mass spectrometer was operated in both positive and negative modes, and multiple reaction monitoring was used for quantification. The method was validated over the concentration ranges 0.05-5 microg/mL for caffeine and paraxanthine, 0.02-2 microg/mL for tolbutamide, 0.1-20 microg/mL for 4-hydroxytolbutamide, carboxytolbutamide, debrisoquine and 5-hydroxydebrisoquine, 5-2500 ng/mL for omeprazole and 5-hydroxyomeprazole, and 1-100 ng/mL for midazolam and 1'-hydroxymidazolam. The intra- and inter-day precision were 0.3-13.7% and 1.9-14.3%, respectively, and the accuracy ranged from 93.5-107.2%. The lower limit of quantification varied between 1 and 100 ng/mL. The present method provides a robust, fast and sensitive analytical tool for the five-probe drug cocktail, and has been successfully applied to a clinical phenotyping study in 16 subjects.  相似文献   

15.
张续  邱天  付慧  杨艳伟  赵峰  林少彬  胡小键 《色谱》2018,36(9):895-903
建立了人尿中9种邻苯二甲酸酯(PAE)代谢物的超高效液相色谱-三重四极杆质谱(UPLC-MS/MS)测定方法。2 mL尿液样本酶解2 h后,经强阴离子固相萃取净化处理;选用Waters ACQUITY UPLC BEH Phenyl色谱柱(100 mm×2.1 mm,1.7 μ m),以0.1%(体积分数)乙酸乙腈和0.1%(体积分数)乙酸水溶液为流动相进行梯度洗脱;在负离子电喷雾多反应监测模式(MRM)下测定9种PAE代谢物含量。8种PAE代谢物在0.39~200 μ g/L范围内、1种PAE代谢物在1.17~600 μ g/L范围内线性关系良好,相关系数均大于0.995。方法检出限为0.06~0.85 μ g/L,定量限为0.20~2.80 μ g/L。3个加标水平的加标回收率为84.1%~122%,精密度为4.5%~14.3%;日内精密度不高于9.3%,日间精密度不高于10.1%;基质效应和稳定性符合分析要求。应用该方法测定50份人尿液样本,邻苯二甲酸单环已酯(MCHP)和邻苯二甲酸单苄酯(MBZP)的检出率分别为0和44.0%,其余7种PAE代谢物的检出率为100%。该方法操作简单、定量准确、稳定性好,适用于人尿中9种PAE代谢物的定量分析。  相似文献   

16.
A simple and rapid method using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the urinary metabolites of benzene, toluene, xylene and styrene in human urine specimens and standard solutions is described. A hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer was compared for the determination of metabolite of aromatic solvents in urine samples. The metabolites selected were: trans,trans-muconic acid, hippuric acid, o-, m- and p-methylhippuric acid and phenylglyoxylic acid. The compounds were well separated from each other on narrow-bore 1-mm i.d. reversed-phase LC C-18 columns. Average recoveries for loading 100 microL of urine samples varied from 88-110% and the quantification limits were less than 30 ng/mL for each analyte (3 ng/mL for trans,trans-muconic acid). The qualitative information obtained (mass accuracy, resolution and full-scan spectra) with the QqTOF mass spectrometer allows a secure identification of analytes in biological matrices.  相似文献   

17.
A new gas chromatographic-tandem mass spectrometric method has been developed and validated for the determination of two N-methylcarbamates, carbofuran and carbaryl and their metabolites in applicators' urine specimens. Mild conditions were used for sample preparation based on enzymic hydrolysis and solid-phase extraction using Oasis HLB sorbent cartridges. Amides, phenols and ketones were first converted to volatile derivatives of trifluoroacetic acid anhydride (TFAA) and afterwards were quantitated using tandem mass spectrometry. Linear calibration equations (1-200 ng mL(-1) urine) were obtained from fortified urine samples for all eight compounds, carbaryl, 1-naphthol, 2-naphthol, and carbofuran, 3-hydroxycarbofuran, 7-phenol, carbofuran-3-keto, 3- hydroxycarbofuranphenol. For all compounds, the limit of detection was lower than 0.1 ng mL(-1). Precision for all compounds, at the concentrations of 1, 10 and 100 ng mL(-1) (n = 5) in-fortified urine samples ranged from 0.7% to 18%. Accuracy was calculated at two concentrations 8 and 80 ng mL(-1) (n = 5) and ranged from -8.4% to 8.2%. Relative recoveries at concentrations of 1, 10 and 100 ng mL(-1), ranged from 71% to 116%. The method was successfully applied to five male applicators and 10 non-applicators (including both smokers and non-smokers).  相似文献   

18.
The US Environmental Protection Agency (EPA) and the European Union (EU) have set restrictive limits for priority carcinogenic polycyclic aromatic hydrocarbons (CPAHs) in surface waters (EPA 3.8 ng L(-1) and EU 2-100 ng L(-1)) in order to protect aquatic life and human health. Currently, methods meeting these sensitivity criteria are not suitable for routine analysis of CPAHs. Here, we present a simple, rapid and low-cost method for the routine monitorization of these pollutants in aquatic environments based on their extraction with coacervates of decanoic acid reverse micelles in the nano- and microscale, and determination by liquid chromatography-fluorimetry (LC-FL). The method involves the stirring of filtered aqueous samples (36 mL) with 4 mL of THF containing 70 mg of decanoic acid for 5 min, its centrifugation for 10 min and the analysis of 20 microL of the resulting coacervate containing the CPAHs by LC/FL. The method is robust, the extractions being independent on salt concentration (up to 1 M), temperature (up to 60 degrees C) and pH (below 4). Besides, the coacervate prevents the CPAHs from adsorption onto the surface of containers during sample storage. No clean-up steps are necessary and the method is matrix-independent. The quantification and detection limits of the method ranged between 0.4 and 3.5 ng L(-1) and 0.1 and 1 ng L(-1), respectively, for the seven priority CPAHs. The method has been successfully applied to the determination of these pollutants in raw and treated sewage from three mechanical-biological treatment plants, two rivers and a reservoir with frequent motorized recreational craft activities, all of them located in the South of Spain. Recoveries for spiked samples in the range 2-30 ng L(-1) were between 88 and 95% with relative standard deviations from 1 to 7%. CPAHs were present in wastewater influents at concentrations in the range 3.9-37 ng L(-1), while the treatment at the WWTPs studied reduced their concentration in their respective effluents in a percentage near 100%. Three CPAHs were present at quantifiable levels in Guadajoz river (1.8-6.6 ng L(-1)) and six in La Bre?a reservoir (1.39-4.8 ng L(-1)).  相似文献   

19.
Sonic spray ionization (SSI) was compared with atmospheric pressure chemical ionization (APCI) as an interface of high-performance liquid chromatography (HPLC)-mass spectrometry (MS) for sensitive analyses of a neuroleptic drug, haloperidol and its two metabolites, such as reduced haloperidol and 4-(4-chlorophenyl)-4-hydroxypiperidine (CPHP), in biological samples. For both SSI and APCI interfaces, HPLC-MS-MS gave higher sensitivity than HPLC-MS. The sensitivities by HPLC-SSI-MS-MS for haloperidol and reduced haloperidol were 100 and 30 times higher, respectively, than those by HPLC-APCI-MS-MS; no spectrum with recognizable peaks was obtained for CPHP with the APCI interface. Therefore, detection limits and regression equations were examined by the HPLC-SSI-MS-MS for human plasma and urine samples spiked with the above drug and its metabolites. Haloperidol, reduced haloperidol, and CPHP showed good linearity in the ranges of 5-800, 10-800, and 100-800 ng/mL, respectively, for both human plasma and urine; their detection limits were 2.5, 5, and 75 ng/mL, respectively, using a new polymer HPLC column which enabled direct application of biological samples.  相似文献   

20.
The enantioselective analysis of hydroxychloroquine (HCQ) and its major metabolites was achieved by HPLC and solid-phase microextraction. The chromatographic separation was performed on a Chiralcel OD-H column using hexane/methanol/ethanol (96:2:2, v/v/v) plus 0.2% diethylamine as the mobile phase, at the flow rate of 1.3 mL/min. The main extraction parameters were optimized. The best condition was achieved by the addition of 10% NaCl and 1 mL phosphate buffer 1 mol/L pH 11 to 3 mL human urine. The extraction was conducted for 40 min at 25 degrees C and the desorption time was 3 min using methanol (100%). PDMS-DVB 60 microm fiber was used in this study. The mean recoveries were 9.3, 9.2, and 14.4% for HCQ, desethylhydroxychloroquine (DHCQ), and desethylchloroquine (DCQ), respectively. The method was linear over the range of 50-1000 ng/mL for HCQ enantiomers and over the range of 42-416 ng/mL for DCQ and DHCQ enantiomers. Within-day and between-day precision and accuracy assays for HCQ and its metabolites were lower than 15%. The preliminary 48 h urinary excretion study performed in human urine showed to be stereoselective. The amount of (+)-(S)-enantiomer excreted was higher than its antipode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号