首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
A method is described for the flow injection determination of total iron as Fe(III) using a solid-phase reactor containing disodium-1,2-dihydroxybenzene-3,5-disulphonate (tiron) as substrate. The iron(III) reacted with tiron to form a complex which absorbs strongly at 667 nm, where it was measured spectrophotometrically. The system has a linear range of 1 to 50 mg L–1 with a detection limit of 0.67 mg L–1. It is suitable for the determination of total iron in multivitamin tablets and iron-rich ground waters, with a relative standard deviation of better than 1.1%. The results obtained compared favourably with the certified values and a standard ICP-AES method. Received: 12 November 1997 / Revised: 9 March 1998 / Accepted: 15 March 1998  相似文献   

2.
A simple and rapid flow-injection spectrophotometric method for the determination of iron(III) and total iron is proposed. The method is based on the reaction between iron(III) and O-acetylsalicylhydroxamic acid (AcSHA) in a 2 % methanol solution resulting in an intense violet complex with strong absorption at 475 nm. Optimum conditions for the determination of iron(III) and the interfering ions were tested. The relative standard deviation for the determination of 5 μg L−1 iron(III) was 0.85 % (n = 10), and the limit of detection (blank signal plus three times the standard deviation of the blank) was 0.5 μg L−1, both based on the injection volumes of 20 μL. The method was successfully applied in the determination of iron(III) and total iron in water and ore samples. The method was verified by analysing a certified reference material Zn/Al/Cu 43XZ3F and also by the AAS method.  相似文献   

3.
The behavior of the Fe(II)/(III) redox system at a Au microelectrode ensemble (Au‐MEE) based on a solid composite by means of direct and cyclic voltammetric analysis (VA) is reported. With a simple electrode activation and sample preparation, the influence of dissolved organic substances was eliminated, providing highly sensitive results. The analytical signal was based on the maximum cathodic current (I) of the first derivative (dI/dE), and iron determination within the 0.002–0.04 mg L?1 range was studied. A sensitive LOD (3σ) value of 0.7 µg L?1 for total iron concentration was calculated; total iron determination in different waters was shown.  相似文献   

4.
A highly sensitive and very simple spectrophotometric flow-injection analysis (FIA) method for the determination of iron(III) at low concentration levels is presented. The method is based on the measurement of absorbance intensity of the red complex at 410 nm formed by iron(III) and diphenylamine-4-sulfonic acid sodium salt (DPA-4-SA). It is a simple, highly sensitive, fast, and low cost alternative method using the color developing reagent DPA-4-SA in acetate buffer at pH 5.50 and the flow-rate of 1 mL min−1 with the sample throughput of 60 h−1. The method provided a linear determination range between 5 μg L−1 and 200 μg L−1 with the detection limit (3S) of 1 μg L−1 of iron(III) using the injection volume of 20 μL. FIA variables influencing the system performance were optimized. The amount of iron(III) and total iron in river and seawater samples was successfully determined. Repeatability of the measurements was satisfactory at the relative standard deviation of 3.5 % for 5 determinations of 10 μg L−1 iron(III). The accuracy of the method was evaluated using the standard addition method and checked by the analysis of the certified material Std Zn/Al/Cu 43 XZ3F.  相似文献   

5.
A kinetic spectrophotometric method that requires no prior measurement of rate constants is developed for the simultaneous determination of iron(II) and iron(III). The method is based on the aerial oxidation of iron(II) in the presence of tiron and acetate ions. The iron(III) formed is subsequently complexed with tiron and the absorbance/time relation is evaluated. The concentrations of iron(III) and iron(II) are obtained from the absorbance values at the start and at equilibrium, respectively, calculated by non-linear least-squares fitting. A linear calibration graph is obtained up to 12 μg ml?1 iron(II)/iron(III). The method is applied to iron-rich ground water.  相似文献   

6.
A new simple and sensitive spectrophotometric method for the determination of chromium(VI) is established. It relies upon the oxidation of iron(II) with the titled ion, in acidic medium, to form iron(III) which is complexed with tiron to form a stable blue color with maximum absorption at 650 nm. Adherence to Beer's law is observed in the range 10–100 μg of chromium(VI) per 25 ml, with a molar absorptivity of 5.6 × 103 liters mol?1 cm?1, sensitivity index of 0.0093 μg cm?1, relative error of ?5.0 to +0.3%, and relative standard deviation of 0.3–4.0%, depending on the concentration level. Furthermore, the reaction needs neither temperature control nor an extraction step.  相似文献   

7.
A sensitive colored reaction of tiron with iron (III) is described. It is based on a complex formation between tiron and iron (III) in basic medium. The method is suitable to determine 0.4–10 ppm of iron (III) with a relative standard deviation of 0.45–1.4% depending on the concentration level, molar absorptivity of 5.7 × 103 liter mol−1 cm−1, and Sandell sensitivity index of 0.0098 μg/cm2.Because of being simple and rapid, this method can certainly be used in routine analysis.  相似文献   

8.
In this paper, we proposed a procedure for the determination of iron(II) and total iron in wine samples employing molecular absorption spectrophotometry. The ligand used is 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) and the chromogenic reaction in absence or presence of ascorbic acid (reducing agent) allows the determination of iron(II) or total iron, respectively. The optimization step was performed using a multivariate technique (Box Behnken design) involving the factors pH, acid ascorbic concentration and reaction time.The method allows the determination of iron(II) and iron(III) in wine samples, with limits of detection and quantification 0.22 and 0.72 μg L−1, respectively. The precision expressed as relative standard deviation (R.S.D.) was 1.43 and 0.56% (both, n = 11) for content of iron(II) in wine samples of 1.68 and 4.65 mg L−1, and 1.66 and 0.87% (both, n = 11) for content of total iron in wine samples of 1.72 and 5.48 mg L−1.This method was applied for determination of iron(II) and total iron in six different wine samples. In these, the iron(II) content varied from 0.76 to 4.65 mg L−1 and from 1.01 to 5.48 mg L−1 for total iron. The results obtained in the determination of total iron by Br-PADAP method were compared with those that were performed after complete acid digestion in open system and determination of total iron employing FAAS. The method of regression linear was used for comparison of these results and demonstrated that there is no significant difference between the results obtained with these two procedures.  相似文献   

9.
A flow-injection chemiluminescence method has been established for the determination of total iron in freshwater samples. The enhanced chemiluminescence emission was caused by the iron(II) from the neutralisation reaction of hydrochloric acid and sodium hydroxide without the use of any chemiluminescent reagent. The calibration graph was linear in the concentration range of 2.8–560 µg L?1 (r 2 = 0.9983, n = 8), with relative standard deviation (RSD; n = 4) in the range of 0.8–2.6%. The limit of detection (S/N = 3) was 0.56 µg L?1 with injection throughput of 180 h?1. The effect of common anions and cations were studied over their environmentally relevant concentrations in freshwaters. The method was successfully applied to determine total iron in freshwater samples. Iron(III) was reduced to iron(II) by using hydroxylammonium chloride. The proposed method was compared with spectrophotometric method and there was no significant difference between the two methods at the 95% confidence level (t-test). Analysis of river water (certified reference material SLRS-4) for iron(II), after reduction of iron(III) with hydroxylammonium chloride, gave good results (2.17 ± 0.22 µM compared with the certificate value of 1.85 ± 0.1 µM).  相似文献   

10.
The formation of [FeSCN]2+ complex in hydrochloric and sulfuric acid medium was studied by spectrophotometry using iron(III) sulfate and ammonium iron(III) sulfate solutions as reactants. A method for the determination of 10–200 μg SCN? in 25 mL water solutions containing ammonium iron(III) sulfate in sulfuric acid medium was developed; its determination limit is 2.6 μg (P = 0.99, n = 9). The method was applied for the analysis of model water samples with macro- and micro-component compositions similar to that of water from the Arigol licensed area. Operational control of the accuracy rate was performed by the standard addition method. The developed method can be applied to analyze water samples containing 1–90 mg/L thiocyanate ions.  相似文献   

11.
This paper describes a new voltammetric procedure for the inorganic speciation of As(III) and As(V) in water samples. The procedure is based on the chemical reduction of arsenate [As(V)] to arsenite [As(III)] followed by the voltammetric determination of total arsenic as As(III) at the hanging mercury drop electrode (HMDE) by adsorptive cathodic stripping voltammetry (AdCSV) in the presence of sodium diethyl dithiocarbamate (SDDC). The reduction step involved the reaction with a mixture of Na2S2O5 and Na2S2O3 in the concentrations 2.5 and 0.5 mg mL?1, respectively, and the sample heating at 80 °C for 45 min. The linear range for the determination of total arsenic as As(III) in the presence of SDDC was between 5 and 150 μg L?1 for a deposition time of 60 s (r=0.992). A detection limit of 1.05 μg L?1 for total As was calculated for the method in water samples using a deposition time of 60 s. The detection limits of 4.2 μg L?1 and 15.0 μg L?1 for total As in seawater and dialysis concentrates, respectively, were calculated using a deposition time of 60 s. The relative standard deviations calculated were 2.5 and 4.0% for five measurements of 20 μg L?1 As(V) as As(III) in water and dialysis concentrates, respectively, after chemical reduction under optimized conditions. The method was applied for the determination of As(III) and total As in samples of dialysis water, mineral water, seawater and dialysis concentrates. Recovery values between 86.0 and 104.0% for As(III) and As(V) added to the samples prove the satisfactory accuracy and applicability of the procedure for the arsenic monitoring.  相似文献   

12.
A sensitive and reliable method is described for the determination of total Sb(III,?V) at traces levels by Osteryoung square-wave anodic stripping voltammery (OSWASV). This method is based on the co-deposition of Sb(III,?V) with Bi(III) onto an edge-plane pyrolytic graphite substrate at an accumulation step. OSWASV studies indicated that the co-deposited antimony was oxidised with anodic scans to give an enhanced anodic peak at about 450?mV vs. Ag/AgCl (sat. KCl). The anodic stripping peak current was directly proportional to the total concentration of antimony in the ranges of 0.01–0.10?µg?L?1, 0.10–1.0?µg?L?1 and 1.0–18.0?µg?L?1 with correlation coefficient higher than 0.995 when 2.0?mol?L?1 hydrochloric acid was used. The detection limits calculated as S/N?=?3 was 5.0?ng?L?1 in 2.0?mol?L?1 hydrochloric acid at 180?s deposition time. The relative standard deviation was 5% (n?=?6) at 0.10?µg?L?1 level of antimony. The analytical results demonstrate that the proposed method is applicable to analyses of real water samples.  相似文献   

13.
A simple and fast flow injection fluorescence quenching method for the determination of iron in water has been developed. Fluorimetric determination is based on the measurement of the quenching effect of iron on salicylic acid fluorescence. An emission peak of salicylic acid in aqueous solution occurs at 409 nm with excitation at 299 nm. The carrier solution used was 2 × 10−6 mol L−1 salicylic acid in 0.1 mol L−1 NH4+/NH3 buffer solution at pH 8.5. Linear calibration was obtained for 5–100 μg L−1 iron(III) and the relative standard deviation was 1.25 % (n = 5) for a 20 μL injection volume iron(III). The limit of detection was 0.3 μg L−1 and the sampling rate was 60 h−1. The effect of interferences from various metals and anions commonly present in water was also studied. The method was successfully applied to the determination of low levels of iron in real samples (river, sea, and spring waters).  相似文献   

14.
A square wave voltammetric method whith a static mercury drop electrode (SMDE) was developed for the quantitative determination of iron (III) in Zn-Fe alloy galvanic baths. Real alloy bath samples were analyzed by the standard addition method and recovery tests were carried out. 0.50 mol L–1 sodium citrate (pH 6.0) or 0.20 mol L–1 oxalic acid (pH 4.0) were applied as supporting electrolytes resulting in both cases in a peak potential of about –0.20 V vs. Ag|AgCl (saturated KCl). The iron (III) concentration in the alloy bath was 9.0 × 10–4 mol L–1. A good correlation (r = 0.9999) was achieved between the iron (III) concentration and the peak current in the electrolytes studied, with linear response ranges from 1.0 × 10–6 to 1.2 × 10–4 mol L–1. Interference levels for some metals such as copper (II), lead (II), chromium (III) and manganese (II) that can hinder the Zn-Fe alloy deposition were evaluated; only copper (II) interferes seriously. Received: 4 April 2000 / Revised: 19 June 2000 / Accepted: 22 June 2000  相似文献   

15.
A fast and sensitive flow-injection procedure is described for the determination of iron(III). The complexing agent is ammonium diisopropyldithiophosphate in a 1:1 (v/v) isopropanol/water carrier stream. The linear range is 0.05–15 mg 1?1 iron(III) with a detection limit of 0.01 mg 1?1 and the injection rate is about 400 h?1.  相似文献   

16.
《Electroanalysis》2004,16(18):1528-1535
In the proposed method As(III) is determined with a wall‐jet flow cell by means of potentiostatic co‐deposition of Au(III) and As(III) at a glassy‐carbon electrode and subsequent chemical stripping with Au(III). Factors affecting sensitivity and precision including acidity, Au(III) concentration, electrodeposition potential and flow rate were optimized. Optimum determination of As(III) in solutions containing 160 mg L?1 and 1.2 M hydrochloric acid was accomplished with an electrolysis potential of ?0.1 V (vs. Ag/AgCl) and a flow rate of 0.59 mL min?1. Different linear concentration ranges were achieved under these conditions with good precision and relative standard deviations between 6–9%. The detection limit obtained after 120 s of electrolysis was 0.55 μg L?1.  相似文献   

17.
A novel solid phase extraction technique for determination of total iron in environmental water samples was developed. The method is based on sorption of Fe(III) ions on octadecyl silica membrane disk modified with a new synthetic ligand dimethyl(E)‐2‐(2‐methoxyphenoxy)‐2‐butenedioate (I). Iron(III) is quantitatively retained on the disk in the pH range of 3–7 at a flow rate of 1–7 mL min−1. The Fe(III) eluted with 10 mL of 0.01 M EDTA and than was measured by flame atomic absorption spectrometry (FAAS) at 248.3 nm. The maximum capacity disk modified by 7 mg of ligand was found to be 197 ± 2 μg of iron(III). The breakthrough volume was greater than 2000 mL. The iron(III) was completely recovered (> 99%) from water with a preconcentration factor of more than 200. The limit of detection of the proposed method was 1.00 ng mL−1. The various cationic and anionic interferences had no effect on the recovery of iron(III) from the binary mixtures. The proposed method was successfully applied to determination of total iron from three different water samples.  相似文献   

18.
A procedure is proposed for the separation and determination of molybdenum in iron matrices by a batch process. It is based on the solid-phase extraction of the molybdenum(V) ion as thiocyanate complex on polyurethane (PU) foam. The extraction parameters were optimized. Using 0.20 mol L–1 hydrochloric acid, a thiocyanate concentration of 0.10 mol L–1, 100 mg of polyurethane foam and shaking time of 10 min, molybdenum (5–400 μg) can be separated and preconcentrated from large amounts of iron (10 mg). Desorption was carried out instantaneously by conc. nitric acid or acetone. Distribution coefficients, sorption capacity of the PU foam and coefficients of variation were also evaluated. The effect of some ions on the separation procedure was assessed. Iron(III) should be reduced to iron(II). The proposed procedure was used to determine molybdenum in standard iron matrices such as steel and pure iron. The achieved results did not show significant differences with certified values.  相似文献   

19.
Application of Dowex 50W-X8 loaded with 2-amino-benzenethiol for preconcentration of total chromium (Cr(VI) and Cr(III)) in water samples and subsequent determination by inductively coupled plasma-atomic emission spectrometry was studied. The reagent 2-amino-benzenethiol loaded onto the resin effectively reduced Cr(VI) to Cr(III) and total chromium (both Cr(VI) and Cr(III)) formed chelate complex with the reagent in the Cr(III) valence state. Experimental parameters such as preconcentration time, solution flow rates, pH, and concentration of the eluent were optimized. The method has been applied for the determination of total chromium in seawater samples in the range of 0.1–200?µg?L?1. A detection limit of 0.3?µg?L?1 was achieved, and the relative standard deviation was about 5%.  相似文献   

20.
Due to be able to migrate or leach from food packaging materials into the foods and/or beverages, development of a new, sensitive and selective analytical methods for low levels of antimony as a food contaminant is of great importance in terms of food safety. In this context, an ultrasonic-assisted cloud point extraction method was developed for the preconcentration and determination of antimony as Sb(III) using 4-(2-thiazolylazo)resorcinol (TAR) and 2-(2-thiazolylazo)-p-cresol (TAC) as chelating agents and sodium dodecyl sulfate as signal enhancing agent at pH 6.0 and mediated by nonionic surfactant, t-octylphenoxypolyethoxyethanol by flame atomic absorption spectrometry. Using the optimized conditions, the calibration curves obtained from Sb(III) with TAR and TAC were linear in the concentration ranges of 0.5–180 and 1–180 μg L?1 with detection limits of 0.13 and 0.28 μg L?1, respectively. The precision (as relative standard deviations, RSDs) was lower than 3.9 % (25 and 100 μg L?1, n: 6). The method accuracy was validated by the analysis of two standard reference materials. The results obtained were statistically in a good agreement with the certified values at 95 % confidence limit. The method has successfully been applied to the determination of Sb(III) and total Sb in selected beverages, milk and fruit-flavored milk products before and after pre-reduction of Sb(V) to Sb(III) with a mixture of KI/ascorbic acid in acidic media. The Sb(V) contents of samples were quantitatively calculated from analytical difference between total Sb and Sb(III) levels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号