首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The presence of lead as a contaminant in calcium supplements has aroused considerable public health interest in recent years. In this investigation lead and lead isotope ratios were determined by ICP-MS in ten brands of calcium supplements after high pressure/temperature digestion. Calcium supplements (200 to 250 mg) were digested in 2 mL of nitric acid at 230 °C and at a pressure of 1770 psi (1.2 × 104 kPa). Lead concentrations were determined by matrix-matched lead standards prepared in a high-purity calcium carbonate matrix. Good recoveries of lead and calcium were obtained for certified animal bone reference material. High levels of Pb (8 to 28 μg Pb per g of calcium) were found in calcium supplements that contain dolomite or bone meal. Chelated and refined calcium supplements had lower Pb levels (0.8 to 0.9 μg Pb/g Ca). Application of lead isotope ratios to distinguish the origin of calcium sources was also explored. Received: 9 June 1998 / Revised: 20 July 1998 / Accepted: 25 July 1998  相似文献   

2.
Ingestion of relatively small amounts of lead is now recognized to cause significant neurological and cognitive effects in humans. Large quantities may be fatal, yet lead poisoning, especially of children, is still a major public health concern in many parts of the world. In rural Mexican communities lead oxide (PbO) is added to ceramic glaze as a fluxing agent, lowering starting firing temperatures to 500 °C. The purpose of this study is to characterize the lead chemical forms in ceramic glazes from the Solis Valley, Mexico, to investigate lead leaching properties of these ceramics, and to demonstrate the applicability of lead isotope signatures as a means of tracing lead source origins. Ceramics were collected from the rural village of Santa Maria de Canchesda, State of Mexico, Mexico. Dried liquid glazes, post-fired glaze material, and pure PbO were analyzed by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT). Results from DRIFT analysis indicate that PbO (1429 cm−1 band) is the active form of lead found in liquid glazes and ceramics. Some shifting of 1429 cm−1 PbO peak to lower wavenumbers occurs in post-fired ceramics, and this may be due to the formation of lead bisilicate during firing. Ceramics samples were leached in 0.02 M citric acid solution for 1 min, and leached lead concentrations were measured using inductively coupled plasma-mass spectrometry (ICP-MS). Lead concentrations in these leachates varied from 0.4-80.4 μg ml−1, while the control pottery from the US leached only 0.1 μg ml−1 lead. Elemental distributions on glaze surfaces were identified by laser ablation (LA)-ICP-MS. Nitric acid extracts of soils, teeth, and ceramic glazes were analyzed for lead isotope ratios (207Pb/206Pb vs. 208Pb/206Pb) using ICP-MS. Similarities of tooth and ceramic lead isotope ratios indicate that ceramics may be a substantial source of body lead burden in the Solis Valley. This study demonstrates the applicability of lead isotope ratios for lead source identification, and it identifies potential health risks from ceramic use induced lead toxicity within the Solis Valley.  相似文献   

3.
Low lead levels in the femurs of mice fed with a lead-depleted diet have been determined by use of electrothermal atomic absorption spectrometry with Zeeman-effect background correction. The method is based on the use of Mg(NO3)2/Pd as matrix modifier which enables significant reduction of the spectral interferences prevalent if chemical modifiers based on NH4H2PO4 with either Ca or Mg are used for samples rich in Ca3(PO4)2 matrix. The method was developed and validated by use of the NIST standard reference material 1486 bone. Bones were decomposed in a pressurized microwave-heated system using 70% nitric acid. Forty-three mice femurs, with a mass of 74.62 ± 12.54 mg, were dissolved in concentrated nitric acid. The lead results found in SRM 1486 (1.25 ± 0.15 μg g–1, n = 9) were in good agreement with the certificate (1.335 ± 0.014 μg g–1). Recoveries of 200 ng lead added to the SRM before or after digestion were 99.0 ± 1.4% and 98.5 ± 1.6%, respectively. The lead detection limit in bone samples is 0.06 μg g–1 dry mass. This method is, therefore, suitable for the determination of very low lead levels (0.06–0.20 μg Pb kg–1 bone) in the femurs of mice fed a diet with lead level of < 20μg kg–1.  相似文献   

4.
The automated modification of the radioanalytical determination of lead and beryllium using AutoAnalyzer modules has been developed. The method for lead determination is based on a two-phase isotope exchange of lead between the sample solution labelled with212Pb and the standard lead diethyldithiocarbamate solution in carbon tetrachloride. For the determination of beryllium a substoichiometric isotope dilution method using7Be as tracer and acetylacetone in chloroform as extractant was used. As little as 0.02 μg/ml of lead and 2 μg/ml of beryllium can be determined by the methods above. The flow diagrams of the automated procedures are presented.  相似文献   

5.
A double focusing ICP-MS, equipped with a Micro Concentric Nebulizer, has been used to determine concentrations and isotopic ratios of lead in recent snow samples (1993–1996) from high alpine sites in Switzerland. Concentrations varied between 0.02 ± 0.002 and 5.5 ± 0.15 ng/g and are slightly lower than concentrations reported by Atteia [1], by Batifol et al. [2], and by Wagenbach et al. [3] for precipitation samples from similar remote sites in Europe. Since concentrations of lead in the fresh snow samples were mainly in the lower pg/g range, the method to determine the isotopic ratios 207Pb/206Pb and 208Pb/206Pb had to be optimized. They could finally be determined with an average standard error of 0.14% within 12 min and a total sample consumption of 0.8 mL. The average ratios 207Pb/206Pb and 208Pb/206Pb were 0.875 and 2.117, respectively. These values are comparable to isotopic compositions of lead in aerosols collected in Western Europe [4] and are less radiogenic than predicted by Grousset et al. [5]. Our data indicate that, although lead emissions from traffic have decreased largely during the last 10 years, the contribution from this source in modern snow is still detectable and seems to be equal to the lead input from other anthropogenic sources (e.g. waste incineration, industry).  相似文献   

6.
The potential of high‐precision calcium and lead isotope ratio measurements using laser ablation coupled to multicollector inductively coupled plasma mass spectrometry (LA‐MC‐ICP‐MS) to aid distinction between four genuine and five counterfeit pharmaceutical packaging samples and further classification of counterfeit packaging samples has been evaluated. We highlight the lack of reference materials for LA‐MC‐ICP‐MS isotope ratio measurements in solids. In this case the problem is minimised by using National Institute of Standards and Technology Standard Reference Material (NIST SRM) 915a calcium carbonate (as solid pellets) and NIST SRM610 glass disc for sample bracketing external standardisation. In addition, a new reference material, NIST SRM915b calcium carbonate, has been characterised in‐house for Ca isotope ratios and is used as a reference sample. Significant differences have been found between genuine and counterfeit samples; the method allows detection of counterfeits and aids further classification of packaging samples. Typical expanded uncertainties for measured‐corrected Ca isotope ratio values (43Ca/44Ca and 42Ca/44Ca) were found to be below 0.06% (k = 2, 95% confidence) and below 0.2% for measured‐corrected Pb isotope ratios (207Pb/206Pb and 208Pb/206Pb). This is the first time that Ca isotope ratios have been measured in packaging materials using LA coupled to a multicollector (MC)‐ICP‐MS instrument. The use of LA‐MC‐ICP‐MS for direct measurement of Ca and Pb isotopic variations in cardboard/ink in packaging has definitive potential to aid counterfeit detection and classification. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
Precision and accuracy of lead isotope ratios of a volatile lead species (PbEt4) were determined by coupling a capillary GC to a magnetic sector multicollector ICP-MS. PbEt4 was prepared by ethylation of a certified lead isotope solution (NIST SRM 981). Coupling was achieved by a transfer line, which allowed simultaneous introduction of a thallium standard solution to correct for mass discrimination. Seven isotopes (202Hg, 203Tl, 204Pb, 205Tl, 206Pb, 207Pb, 208Pb) were monitored simultaneously with a transient resolution of 50 ms. Pb isotope ratios for the PbEt4 peaks were calculated using transient peak integrals of each isotope signal. Absolute detection limits were 20 (204Pb), 0.7 (206Pb), 1 (207Pb) and 0.3 pg (208Pb). Precision was assessed for five replicate injections of PbEt4 in iso-octane, corresponding to a total amount of 300 pg of Pb. Precision of isotope ratios for 206Pb, 207Pb and 208Pb were better than 0.07% (RSD), with ratios including 204Pb being one order of magnitude worse. Accuracy using mass bias correction via 203Tl/205Tl ranged from 0.18% for 208Pb/206Pb to 0.9% for 208Pb/204Pb.  相似文献   

8.
E. Marguí  I. Queralt 《Talanta》2007,73(4):700-709
A methodology for a precise and accurate determination of lead isotope ratios in mining wastes by inductively coupled plasma quadrupole-based mass spectrometry (ICP-QMS) has been developed. The study of instrumental bias factors led to the conclusion that internal correction to compensate mass discrimination is required as well as an interference equation correction when Hg is present. The proposed method has been applied to determine lead isotope ratios in several mining wastes, soils and sediments collected at three mining areas in Spain (Aran Valley, Cartagena and Osor).Statistical analysis highlights that 206Pb/207Pb and 208Pb/207Pb lead isotope ratios can be used as a fingerprint of mining waste origin which is related to the geological age of the lead ore.On the other hand, no statistically significant isotopic differences between original ore samples (galena) and processing wastes within a mining district were found, corroborating a unique lead source. Moreover, the lead isotopic composition of soil and sediment samples collected at the studied mining areas is close to that determined in the mining tailings from the same areas, suggesting that the unusual high content of lead in these samples is derived from mining activities rather than from other lead sources.  相似文献   

9.
We measured the concentrations of Pb and its isotope ratios in coconmittantly obtained tap water and plumbing materials by inductively coupled mass spectrometry (ICP-MS). The Pb concentrations were determined by external calibration with209Bi as an internal standard. Isotope ratios were measured and mass discrimination corrected by normalization to NIST SRM-981 (common lead isotopic standard). Student/s t-test was used to compare the isotopic ratios of206Pb/207Pb,206Pb/208Pb, and207Pb/208Pb in the tap water with those in various plumbing materials. The comparisons revealed that the source of Pb in most of the tap water samples was derived from copper pipe or solder.  相似文献   

10.
Fortunato G  Ritter A  Fabian D 《The Analyst》2005,130(6):898-906
White lead (2PbCO(3).Pb(OH)(2)), a common component in 17c. artists' painting materials, was singled out to investigate the potential of lead isotope abundance ratios in the field of authentication and origin assignment. Paintings by Peter Paul Rubens, Anthony van Dyck and other Old Masters of the Northern and Southern schools were chosen for this study. An interdisciplinary approach was chosen using both analytical instrumental methods, art technological and art historical knowledge. Minute samples taken from paintings from selected art collections worldwide were investigated using mass spectrometry, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). The high precision lead isotope abundance ratios were measured by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The determination of the calcium matrix influence with respect to possible bias effects to the isotope ratios gave clear decision support, to whether a result lies within the stated combined measurement uncertainty of the result, to eliminate time-consuming matrix separations. The scatter plots of the measured isotope abundance ratios for the painting pigments from P. P. Rubens, A. van Dyck and other Flemish painters exhibit a very narrow distribution forming a cluster. The range of the measured ratio (206)Pb/(204)Pb amounts to 0.55% and for the ratio (207)Pb/(204)Pb to 0.2%. The comparison of the data to cis-alpine (Italian) sample pigments from paintings from the same time period reveals a clear distinction between the two fields. With respect to the lead isotope data originating from the ores it is assumed that the pigment isotope ratio distribution can be explained by very distinct origin of raw materials. Presumably, no mixing of different lead ores from Europe took place. The comparison of the measured white lead isotope ratio values (Flemish paintings) and the data from ore samples led to the unexpected conclusion that local ores were not used for the pigment production but British or German sources.  相似文献   

11.
Rhodium (Rh) was investigated as a permanent modifier for the atomization of Pb from biological fluids in W-filament atomic absorption spectrometry (AAS). Heating the W-filament with a Rh solution provided a protective coating for subsequent determinations of Pb in blood and urine matrices. The W-filament AAS instrumentation used was based on a prototype design that utilized self-reversal background correction scheme and peak area measurements. We found that Rh not only stabilized Pb during the pyrolysis step, but also facilitated the removal of carbonaceous residues during the cleaning step, requiring much less power than with phosphate modifier. Thus, the filament lifetime was greatly extended to over 300 firings. Periodic reconditioning with Rh was necessary every 30 firings or so. Conditioning the filament with Rh also permitted direct calibration using simple aqueous Pb standards. The method detection limit for blood Pb was approximately 1.5 μg dl−1, similar to that reported previously. Potential interferences from concomitants such as Na, K, Ca and Mg were evaluated. Accuracy was verified using lead reference materials from the National Institute of Standards and Technology and the New York State Department of Health. Blood lead results below 40 μg dl−1 were within ±1 μg dl−1 of certified values, and within ±10% above 40 μg dl−1; within-run precision was ±10% or better. Additional validation was reported using proficiency test materials and human blood specimens. All blood lead results were within the acceptable limits established by regulatory authorities in the US. When measuring Pb in urine, sensitivity was reduced and matrix-matched calibration became necessary. The method of detection limit was 27 μg l−1 for urine Pb. Urine lead results were also validated using an acceptable range comparable to that established for blood lead by US regulatory agencies.  相似文献   

12.
Archaeological samples originating from a cemetery of a Roman settlement, Pretorium Agrippinae (1st–3rd century A.D.), excavated near Valkenburg (The Netherlands) have been subjected to Pb isotopic analysis. The set of samples analysed consisted of infant bone tissue and possible sources of bone lead, such as the surrounding soil, garum, and lead objects (e.g., water pipes). After sample digestion with quantitative Pb recovery and subsequent quantitative and pure isolation of lead, the Pb isotopic composition was determined via multicollector ICP–mass spectrometry. The Pb isotope ratio results allowed distinction of three groups: bone, soil, and lead objects + garum. The 208Pb/206Pb ratio ranges were between 2.059 and 2.081 for the soils, between 2.067 and 2.085 for the bones, and between 2.087 and 2.088 for the lead objects. The garum sample is characterised by a 208Pb/206Pb ratio of 2.085. The bone group is situated on the mixing line between the soil and lead object groups, allowing the statement that diagenesis is not the main cause of the Pb found in the bones.   相似文献   

13.
Gao B  Liu Y  Sun K  Liang X  Peng P  Sheng G  Fu J 《Analytica chimica acta》2008,612(1):114-120
A method for the accurate determination of Cd and Pb isotope compositions in sediment samples is presented. Separation of Cd and Pb was designed by using an anionic exchange chromatographic procedure. Measurements of Cd isotopic compositions were carried out by multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS), by using standard-sample bracketing technology for mass bias correction and Pb isotopic ratios were determined by thermal ionization mass spectrometry (TIMS). The factors that affect the accurate and precise Cd isotope compositions analysis, such as instrumental mass fractionation and isobaric interferences, were carefully evaluated and corrected. The Cd isotopic results were reported relative to an internal Cd solution and expressed as the δ114/110Cd. Five Cd reference solutions and one Pb standard were repeatedly measured in order to assess the accuracy of the measurements. Uncertainties obtained were estimated to be lesser than 0.11‰ (2s) for the δ114/110Cd value. Analytical uncertainties in 2s for Pb isotopic ratios were better than 0.5‰. The method has been successfully applied to the investigation of Cd and Pb isotope compositions in sediment samples collected from North River in south China.  相似文献   

14.
A procedure for the determination of Cd, Cu, Pb, Se and Tl by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) with calibration by isotopic dilution is proposed. The slurry is prepared by mixing the sample with diluted nitric and hydrofluoric acids in an ultrasonic bath and then in a water bath at 60 °C for 120 min. The slurries were let to stand at least for 12 h, manually shaken before poured into the autosampler cups and homogenized by passing through an argon flow, just before pipetting it into the furnace. The analytes were determined in two groups, according to their thermal behaviors. The furnace temperature program was optimized and the selected compromised pyrolysis temperatures were: 400 °C for Cd, Se and Tl and 700 °C for Cu and Pb. The vaporization temperature was 2300 °C. The analyses were carried out without modifier as no significant effect was observed for different tested modifiers. Different sample particle sizes did not affect the sensitivity significantly, then a particle size ≤50 μm was adopted. The accuracy was checked by analyzing five certified reference sediments, with analytes concentrations from sub-μg g−1 to a few hundreds μg g−1. The great majority of the obtained concentrations were in agreement with the certified values. The detection limits, determined for the MESS-2 certified sediment, were, in μg g−1: 0.01 for Cd; 0.8 for Cu; 0.4 for Pb; 0.4 for Se and 0.06 for Tl. The precision was adequate with relative standard deviations lower than 12%. Isotopic dilution showed to be an efficient calibration technique for slurry, as the extraction of the analyte to the liquid phase of the slurry and the reactions in the vaporizer must help the equilibration between the added isotope and the isotope in the sample.  相似文献   

15.
206Pb/207Pb isotope ratios of dry deposit samples in the Metropolitan Zone of Mexico Valley (MZMV) were determined and correlated with some contemporary environmental material such as gasoline, urban dust, etc., as possibile pollution sources, the latter presenting different signatures 206Pb/207Pb ratios were determined in samples “as is” by ICP-MS, using an Elan-6100. A standard material NIST-981 was used to monitor accuracy and to correct mass fractionation. The calculated enrichment factors of lead (taking rubidium as a conservative endogenous element) show its anthropogenic origin with percentages higher than 97.65%. 206Pb/207Pb ratio in dry deposit samples ranges from 0.816 to a maximum of 1.154, following a normal distribution. Arithmetic mean was 0.9967±0.0864 lower than those of possible pollution sources: 1.1395±0.0165 for gasoline, 1.071±0.008 for industrially derived lead and, for the more radiogenic natural soil and urban dust values ranging from 1.2082±0.022 to 1.211±0.108. The possible origin of lead in gasoline used prior to 1960 is discussed.  相似文献   

16.
In present research, fifteen surficial and two profile sediment samples were studied in terms of sediment chronology and pollution degree on the ground of pollution indexes such as enrichment factor (EF), contamination factor (CF), Pollution Load Index (PLI) and lead isotope ratios (206Pb/207Pb, 208Pb/206Pb). Lead-210 (polonium-210) activity concentrations were measured by utilizing alpha spectrometry. Sediment chronology was determined via modified CRS mathematical model. Average mass accumulation rates are 0.301 and 0.227 g cm?2 year?1 in Bak?rçay River mouth and Ayval?k offshore stations respectively. Mass accumulation rates do not display the systematic increases along the cores from bottom layers to top layers. In Bak?rçay River mouth station 210Pb flux is higher than the range of global atmospheric 210Pb flux value. Due to the high CF and EF values of Sr both of stations have hydrothermal features. Ayval?k offshore station has displayed Na, Cd pollution since 1945, but Na, Cd, As, Mo, Ag pollutions have existed in Bak?rçay River mouth station since 1983 in terms of CF and EF values. According to PLI index, Bak?rçay River mouth station has “starting level pollution” degree and it displayed an “acute corruption” in 1981. 206Pb/207Pb ratios range from 1.17 to 1.25, 208Pb/206Pb ratios range from 1.99 to 2.16 in study area. When 206Pb/207Pb and 208Pb/206Pb ratios are evaluated with together, it is seen that both of the stations have had the natural (geologic) sediments since 2011.  相似文献   

17.
Two methods for the determination of submugram amounts of lead are described. (A) Lead is selectively extracted with carbon tetrachloride from an alkaline solution containing exccss diethyl-dithiocarbamatc (DDC) and cyanide. Traces of DDC arc back-extracted. The lead in the DDC complex is exchanged with 204Tl and the amount of 204Tl in the organic layer acts as a measure for the lead. The limit of sensitivity is 0.1 mg; the standard deviation is 11% (for 0. 1μg). Bismuth and thallium interfere; their influence can be accounted for with the help of EDTA, however. (B) Excess cyanide is added to the alkaline sample solution and lead is exchanged selectively with 204Tl by shaking with a CHCl3 solution containing 204T1(DDC)1. As the process is not 100% effective (with a reasonable excess of the thallium complex) isotope dilution with 210Pb is also carried out. The amount of 204Tl in the aqueous layer acts as a measure for the exchanged lead. The limit of sensitivity is 0.05 μg and the standard deviation is 12% (for 0.05 μg). Bismuth and thallium must be removed in advance, e.g. by anion exchange.  相似文献   

18.
Concentration levels, potential sources and bioavailability of trace elements in marine sediments from Kongsfjorden (Svalbard Islands, Norwegian Arctic) were assessed and discussed. Surface sediments were collected by a Ponar grab and characterised in terms of mineralogical composition, grain-size distribution, total organic carbon and nitrogen percentage contents, and major and trace elements concentrations. Anthropogenic and natural sources of trace elements were inferred from lead isotope ratios, while the potential metal bioavailability was evaluated by size-fractionation and solid-phase speciation studies and by the analysis of acid-volatile sulphides (AVS) and simultaneously extracted metals (SEM). Concentrations of metals, their enrichment factors and solid speciation patterns collectively indicated that the anthropogenic impact of trace elements in the fjord is generally low, with a minor enrichment with respect to crustal values (by a factor of 2–11) for As, Cr, Ni and V. The lead isotope ratios (208Pb/207Pb: 2.474–2.498 and 206Pb/207Pb: 1.206–1.212) were close to the natural signature except in the outer fjord, due to the influence of the Atlantic marine circulation. Many elements of toxicological concern (e.g. Pb, V, Zn) were enriched in the finest sediment fraction, which was by far the preponderant one, especially in the inner fjord. However, less than 15% of most trace elements (exceptions Cd and Mn) in the finest fraction was actually associated with easily leachable sediment phases. Finally, the high SEM/AVS ratios determined on samples from sites close to the glacier fronts (11–15), due to low AVS content, highlighted that the sediment in that zone cannot remove additional inputs of heavy metals by sulphide precipitation.  相似文献   

19.
Abstract

Experimental plots have been set up at two Research Stations in upland areas of Scotland with the intention of characterising environmental samples using lead isotopic composition which varies according to the original source of the lead. Thermal ionisation mass spectrometry (TIMS) was used to measure lead isotope ratios with high precision. The 206Pb/207Pb ratios in rainwater were in the range from 1.101 to 1.153 over a period of two years at the two sites. Low ratios were associated with the very low ratios found in Britain in petrol additives during that period whereas higher ratios indicated a larger component derived from industrial sources at the Hartwood site. The 206Pb/207Pb ratios in the surface (0–2.5 cm) soil from a roadside plot were low (1.1126 and 1.1159 in 1989 and 1990, respectively) but the ratios in surface soils in plots distant from the road were considerably higher. Whereas the lead in roadside soil had a 206Pb/207Pb ratio indicating its source to be predominantly in recent petrol lead, there were significant components from other sources in the soils away from the road. The washing of grass samples resulted in no significant change in the lead isotope ratios. The lead isotope ratios measured in grass samples reflect the isotopic character of current atmospheric inputs but those in surface soil samples are an integrated record of atmospheric deposition over a long period of time. An undisturbed plot under a tree canopy had high concentrations of lead in the surface soil and low 206Pb/207Pb ratios. The ratios in fallen leaves on this plot were slightly but significantly lower than those in the grass grown on the plot. It would appear that the tree canopy is effective at scavenging lead carried in the atmosphere.  相似文献   

20.
Size fractionated aerosols were collected with low pressure Berner impactors on a radio/TV tower 110 m above ground on a hill 10 km east of Bern at a total elevation of 1060 m asl. Two different wind sectors were chosen with the goal of assessing any differences in lead concentration and the 3 radiogenic lead isotopes (206,207,208) for east and west wind, respectively. A leaching technique was used to extract the lead quantitatively from the surface of the impaction foils. This method has been proven to be better suited for airborne particles than complete microwave digestion because it is less time consuming and contamination risk is smaller. Blank considerations played a major role in choosing all the chemicals, tubes, beakers and selecting the analytical method. Lead concentrations were determined with GF-AAS and lead isotopes with two different ICP-MS systems, one being a multicollector system. Precision of the simultaneous multicollector system was found to be at least a factor of 3 better than that of the sequentially operating ICP-MS. The small variations in isotope ratios from the two wind sectors can be distinctly seen with this enhanced precision. The observed relative difference in isotope ratios between east- and westwind was ~0.6% for 207Pb/206Pb and ~0.5% for 208Pb/206Pb.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号