首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A PVC membrane electrode for lead ions based on 5,5′-dithiobis-(2-nitrobenzoic acid) as membrane carrier was prepared. The electrode exhibits a Nernstian response for Pb2+ over a wide concentration range (1.0×10−2–4.0×10−6 M). It has a relatively fast response time and can be used for at least 3 months without any divergence in potentials. The proposed electrode revealed good selectivities for Pb2+ over a wide variety of other metal ions and could be used in a pH range of 2.0–7.0. It was used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples.  相似文献   

2.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   

3.
Yang J  Ge H  Jie N  Ren X  Zou H 《Talanta》1994,41(12):2055-2060
The study indicated that yttrium(III) could form an ion association compound with a new synthetic reagent, 1,6-bi(1′-phenyl-3′-methyl-5′-pyrazolone-4′-)hexanedione (BPMPHD) and cetyl trimethyl ammonium bromide (CTMAB). The compound could enhance the natural fluorescence of BPMPHD by about 260 times, upon which a new fluorescence method was developed for determining yttrium in rare earth (RE) samples. The determination range was 9–900 ng/ml. The detection limit was 1.8 ng/ml. The composition of the ion association was [Y(BPMHD)2]CTMAB+.  相似文献   

4.
Masadome T  Sonoda R  Asano Y 《Talanta》2000,52(6):1123-1130
A potentiometric flow injection determination method for iodide ion in a photographic developing solution was proposed by utilizing a flow-through type iodide ion-selective electrode detector. The sensing membrane of the electrode was Ag2S–AgI membrane. The response of the electrode detector as a peak-shape signal was obtained for injected iodide ion in a photographic developing solution. A linear relationship in the subnernstian zone was found to exist between peak height and the concentration of the iodide ion in a photographic developing solution in a concentration range from 0 to 6.0×10−5 mol l−1. The relative standard deviation for ten injections of 2×10−5 mol l−1 iodide ion in a photographic developing solution was 0.96% and the sampling rate was approximately 12–13 samples h−1. The iodide ion could be determined under coexisting of an organic reducing reagent and inorganic electrolytes of high concentration in a photographic developing solution sample solution by the present method.  相似文献   

5.
A catalytic flow-injection (FI) method was developed for the determination of 10−9 mol l−1 levels of vanadium(IV, V). The method is based on the catalytic effect of vanadium(V) on oxidation of N-(3-sulfopropyl)-3,3′,5,5′-tetramethylbenzidine (TMBZ·PS) using bromate as oxidant to form a yellow dye (λmax=460 nm). The use of 5-sulfosalicylic acid (SSA) as an activator enhanced the sensitivity of the method. The calibration graphs with a working range 0.05–8.0 ng ml−1 were obtained for vanadium(V). Vanadium(IV) was also determined, being oxidized by bromate. The detection limit (signal/noise, S/N=3) was 0.01 ng ml−1 (ca. 2×10−10 mol l−1) vanadium. The relative standard deviations (R.S.D.) for 15 determinations of 0.5 ng ml−1 vanadium, and for ten determinations of 0.1 and 1.0 ng ml−1 vanadium were 0.41, 2.6 and 0.25%, respectively, with a sampling rate of 15 samples h−1. The proposed method was successfully applied to the determination of vanadium in natural waters.  相似文献   

6.
In this paper, we summarise our recent research interest in the hydrothermal synthesis and structural characterisation of multi-dimensional coordination polymers. The use of N-(phosphonomethyl)iminodiacetic acid (also referred to as H4pmida) in the literature as a versatile chelating organic ligand is briefly reviewed. This molecule plays an important role in the formation of centrosymmetric dimeric [V2O2(pmida)2]4− anionic units, which were first used by us as building blocks to construct novel coordination polymers. Starting with [V2O2(pmida)2]4− in solution, we have isolated [M2V2O2(pmida)2(H2O)10] species (where M2+ = Mn2+, Co2+ or Cd2+) via the hydrothermal synthetic approach, which were then employed for the construction of [CdVO(pmida)(4,4′-bpy)(H2O)2]·(4,4′-bpy)0.5·(H2O), [CoVO(pmida)(4,4′-bpy)(H2O)2]·(4,4′-bpy)0.5, [Co(H2O)6][CoV2O2(pmida)2(pyr)(H2O)2]·2(H2O) and [Cd2V2O2(pmida)2(pyr)2(H2O)4]·4(H2O) by the inclusion of bridging organic ligands in the reactive mixtures, such as pyrazine (pyr) and 4,4′-bipyridine (4,4′-bpy). These materials can contain channel systems, and exhibit magnetic behaviour, not only due to the V4+ centres but also to the transition metal centres which establish the links between neighbouring dimeric [V2O2(pmida)2]4− anionic units. A closely related anionic moiety, [Ge2(pmida)2(OH)2]2−, was engineered to allow the study of such crystalline hybrid materials using one- and two-dimensional high-resolution solid-state NMR.  相似文献   

7.
A μ-bis(tridentate) ligand named 2-phenyl-1,3-bis[3′-aza-4′-(2′-hydroxyphenyl)-prop-4-en-1′-yl]-1,3-imidazolidine (I) has been synthesized and scrutinized to develop iron(III)-selective sensors. The addition of sodium tetraphenyl borate and various plasticizers, viz., chloronaphthalene, dioctylphthalate, o-nitrophenyl octyl ether and dibutylphthalate has been used to substantially improve the performance of the sensors. The membranes of various compositions of the ligand were investigated and it was found that the best performance was obtained for the membrane of composition (I) (10 mg):PVC (150 mg):chloronaphthalene (200 mg):sodium tetraphenyl borate (9 mg). The sensor showed a linear potential response to iron(III) over wide concentration range 6.3 × 10−6 to 1.0 × 10−1 M (detection limit 5.0 × 10−6 M) with Nernstian slope (20.0 mV/decade of activity) between pH 3.5 and 5.5 with a quick response time of 15 s. The potentiometric selectivity coefficient values as determined by match potential method (MPM) indicate excellent selectivity for Fe3+ ions over interfering cations. The sensor exhibits adequate life of 2 months with good reproducibility. The sensor could be used in direct potentiometry.  相似文献   

8.
A series of Cu(II) complexes of disubstituted 2,2′-bipyridine bearing ammonium groups [Cu(L1−4)2Br]5+ (1–4, L1 = [5,5′-(Me2NHCH2)2-bpy]2+, L2 = [5,5′-(Me3NCH2)2-bpy]2+, L3 = [4,4′-(Me2NHCH2)2-bpy]2+, L4 = [4,4′-(Me3NCH2)2-bpy]2+ and bpy = 2,2′-bipyridyl) were synthesized, of which complexes 1 and 4 were structurally characterized. Both coordination configurations of Cu(II) ions can be described as distorted trigonal bipyramid. The interaction between all complexes and CT-DNA was evaluated by thermal-denaturation experiments and CD spectroscopy. Results show that the complexes interact with CT-DNA via outside electrostatic interactions and their binding ability follows the order: 1 > 2 > 3 > 4. In the absence of any reducing agents, the cleavage of plasmid pBR322 DNA by these complexes was investigated and the hydrolysis kinetics of DNA was studied in Tris buffer (pH 7.5) at 37 °C. Obtained pseudo-Michaelis–Menten kinetic parameters: 15.0, 13.6, 2.01 and 1.69 h−1 for 1, 2, 3 and 4, respectively, indicate that complexes 1 and 2 exhibit very high DNA cleavage activities. According to their crystal data, the high nuclease activity may be attributed to the strong interaction of the metal moiety and two ammonium groups with phosphate groups of DNA.  相似文献   

9.
Zhou CL  Lu Y  Li XL  Luo CN  Zhang ZW  You JM 《Talanta》1998,46(6):1531-1536
A new method is described for the determination of antimony based on the cathodic adsorptive stripping of Sb(III) complexed with 2′,3,4′,5,7-pentahydroxyflavone(morin) at a static mercury drop electrode (SMDE). The reduction current of the adsorbed antimony complex was measured by 1.5th-order derivative linear-sweep adsorption voltammetry. The peak potential is at −0.51 V (vs. SCE). The effects of various parameters on the response are discussed. The optimized analytical conditions were found to be: supporting electrolyte, chloroacetic acid (0.04 mol/l, pH 2.3); concentration of morin, 5×10−6 mol/l; accumulation potential, −0.25 V (vs. SCE); scan rate, 100 mV/s. The limit of detection and the linear range were 7×10−10 mol/l and 1.0×10−93.0×10−7 mol/l Sb(III) for a 2-min accumulation time, respectively. This method has been applied to the determination of Sb(III) in steel and brass samples and satisfactory results were obtained. The adsorptive voltammetric characteristics and composition of the Sb(III)–morin complex were studied.  相似文献   

10.
扩散系数是描述物质扩散过程的重要参数,而用膜池法、放射性或荧光示踪法、分子动力学模拟等现有方法无法原位进行生物体系中离子扩散系数的实时测量。 本文利用离子选择性微电极响应迅速、高选择性、高灵敏度、高空间分辨率、对样品无污染等优势,通过分析单个植物细胞原生质体在培养液中破裂时所形成的离子浓度脉冲信号,建立了相应的点源扩散模型,推导出了描述离子浓度随时间变化的理论公式,并通过该公式对实验测得的脉冲信号进行拟合,得到了离子的扩散系数,从而建立了一种用离子选择性微电极原位测定离子扩散系数的新方法,并将其应用于芦荟细胞原生质体破裂时离子扩散系数的测定,得到了Ca2+、Na+和K+的扩散系数分别为(6.51±0.12)×10-6、(2.93±0.15)×10-5和(3.03±0.35)×10-5 cm2/s。 对比发现,拟合得到的Ca2+、Na+和K+扩散系数均略高于已报道的数值(纯水中),这一现象的产生可能是因为原生质体是在低渗液中吸水膨胀,细胞膜内压力升高产生内外压力差,该压力差会加速细胞破裂时离子的扩散。 这一方法对生物体系无干扰,较好地解决了生物体系中离子扩散系数原位实时测量的难题。  相似文献   

11.
De Marco R  Phan C 《Talanta》2003,60(6):1215-1221
The direct flow injection potentiometric (FIP) analysis of phosphate in hydroponic nutrient solution has been carried out using a cobalt-wire ion-selective electrode (ISE). Synthetic hydroponic nutrient solution, commercial hydroponic nutrient solution and working hydroponic farm nutrient solution were analysed for phosphate using the FIP technique. It is shown that FIP results compare favourably to standard methods of analysis such as spectrophotometry and indirect photometric ion-pair chromatography. Reproducible FIP response curves with a slope of −(47.57±0.03) mV per decade and intercept of −(169.7±0.1) mV were obtained for four separate calibrations in the concentration range 5.0×10−4–1.0×10−2 M H2PO4. Anion corrections for interferences by Cl, NO3 and SO42− were applied to all samples using the selectivity coefficients determined independently using a fixed interference method. Nevertheless, it was found that anion corrections were not necessary, as the deviations fell within the bounds of experimental error for the cobalt-wire ISE technique (i.e.±2–5% R.S.D.). The proposed FIP method enables the direct determination of phosphate in hydroponic nutrient solutions.  相似文献   

12.
The two ion-pair complexes, [pyH]2[Zn(mnt)2] (1) and [4,4′-bipyH2]-[Zn(mnt)2] (2), were synthesized, where mnt2− denotes maleonitriledithiolate, and [pyH]+, [4,4′-bipyH2]2+ represent pyridinium and diprotonated 4,4′-bipyridinium, respectively. Their single crystal structures show that there are strong bifurcated H-bonding interactions between the cations of the pyridinium derivative and the [Zn(mnt)2]2− anions in both 1 and 2. The bifurcated H-bonding interactions between the N–H of the pyridiniums and the CN groups of the mnt2− ligands give rise to a 2D layered H-bonding network, the adjacent layers come together in such way as mutual embrace to give a tight pack, thus 2D hydrogen-bonding sheets further develop into 3D H-bonding networks through weak C–HS and ππ stacking interactions in 1. As for 2, the cations and anions connect into several types of H-bonding macrorings ([2+2], [3+3] and [4+4]), these H-bonding macrorings fuse to extend into 2D layered structure, the interpenetration between [3+3] and [4+4] type H-bonding macrorings in the adjacent layers give further rise to novel 3D extended H-bonding networks, in which there are clearly parallel stacks of cations and the chelate rings of anions.  相似文献   

13.
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH4OH+0.05% w/v Triton X-100®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO3)2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1−1 Se, corresponding to 30 μg l−1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l−1, with a mean value of 114±22 μg l−1.  相似文献   

14.
Kapoor J  Kumar A  Gupta U  Rao AL 《Talanta》1994,41(12):2061-2065
A rapid, simple, direct, and sensitive method has been developed for the determination of maneb (manganese ethylenebisdithiocarbamate) based on the formation of manganese-4-(2′-pyridylazo) resorcinol complex by a ligand displacement reaction, which is rendered water soluble by a cationic surfactant cetyltrimethylammonium bromide (CTAB) by the formation of an ion association complex. Beer's law is obeyed over the concentration range 0.08–2.4 μg/ml of the final solution at 500 nm in pH range 8–12. The molar absorptivity and Sandell's sensitivity are calculated to be 8.84 × 104 l.mol−1.cm−1 and 0.003 μg/cm2, respectively. The developed method has been applied to the determination of maneb in commercial formulations, synthetic mixture, grain samples and vegetables.  相似文献   

15.
The paper presents a rapid method for the determination of dioxopromethazine hydrochloride (DPZ), an antihistamine drug, by the capillary electrophoresis with electrochemiluminescene detection (CE–ECL) using tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) reagent. This CE–ECL detection method has high sensitivity, good selectivity and reproducibility for DPZ analysis. Under the optimized conditions: separation capillary, 38 cm length (25 μm i.d.); sample injection, 10 s at 8 kV; separation voltage, 12.5 kV; running buffer, 20 mmol L−1 sodium phosphate of pH 6.0; detection potential, 1.15 V; 50 mmol L−1 of phosphate buffer (pH 7.14) containing 5 mmol L−1 of Ru(bpy)32+ in ECL detection cell, the detection limit of DPZ was 0.05 μmol L−1 (S/N = 3). The linear range extended from 5 to 100 μmol L−1. The linear curve obtained was Y = 181.62 + 9.28X with a correlation coefficient of 0.9970. The relative standard deviations of the ECL intensity and the migration time for six continuous injections of 5 μmol L−1 DPZ were 3.7% and 0.92%, respectively. The CE–ECL method was applied to analyze DPZ in real samples including tablets, rat serum and human urine, and satisfactory results were obtained without interference from samples matrix. The CE–ECL technique was proved to be a potential method for the detection of DPZ in clinic analysis.  相似文献   

16.
Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin (I) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy)33+) in the presence of acetate. The Ru(bipy)33+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy)32+) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy)32+ 30 μL, 0.4 M Na acetate 16 μL and I sample 15 μL; the flow rates were 60 μL s−1 for the aspiration into the holding coil and 100 μL s−1 for detection. Calibration curve relating the intensity of CL (peak height of the transient CL signal) to concentration of I was curvilinear (second order polynomial) for 0.1–50 μM I (r = 0.9997; n = 9) with rectilinear section in the range 0.1–10 μM I (r = 0.9995; n = 5). The limit of detection (3σ) was 0.05 μM I. Repeatability of peak heights (R.S.D., n = 10) ranged between 2.4% (0.5 μM I) and 2.0% (7 μM I). Sample throughput was 180 h−1. The method was applied to determination of 1 to 5% of I in semisolid dosage forms (gels and ointments). The results compared well with those of UV spectrophotometric method.  相似文献   

17.
A simple and sensitive sequential injection spectrophotometric procedure is proposed for the determination of trace amounts of iodide in pharmaceutical preparations. The method is based on the catalytic effect of iodide on the (tetra base) 4,4′-methylenebis(N,N-dimethylaniline)-chloramine-T reaction in acidic solution. The method involves a sequential aspiration of 255 μl sample/standard followed by 170 μl tetra base and then 128 μl chloramine-T solutions into a carrier stream to be stacked inside a holding coil and flow reversed through a reaction coil towards a detector. The resulting colored compound is measured at 600 nm using an UV/Vis-spectrophotometer. All the parameters that affect the reaction were evaluated and the calibration curve is linear over a range of 0.1–6.0 μg l−1 of iodide concentration with detection limit of 0.05 μg l−1. A sample throughput of 80 samples per hour and relative standard deviation of less than 2.0% was achieved. The method is successfully applied for the determination of iodide in three different samples (tablets).  相似文献   

18.
The photophysics of three complexes of the form Ru(bpy)3−(pypm)2+ (where bpy2,2′-bipyridine, pypm 2-(2′-pyridyl)pyrimidine and P=1, 2 or 3) was examined in H2O, propylene carbonate, CH3CN and 4:1 (v/v) C2H5OH---CH3OH; comparison was made with the well-known photophysical behavior of Ru(bpy)32+. The lifetimes of the luminescent metal-to-ligand charge transfer (MLCT) excited states were determined as a function of temperature (between −103 and 90 °C, depending on the solvent), from which were extracted the rate constants for radiative and non-radiative decay and ΔE, the energy gap between the MLCT and metal-centered (MC) excited states. The results indicate that *Ru(bpy)2(pypm)2+ decays via a higher lying MLCT state, whereas *Ru(pypm)32+ and *Ru(pypm)2(bpy)2+ decay predominantly via the MC state.  相似文献   

19.
Rotational-state distributions of the CO+ (A–X, B–X) and N2+(B–X) emissions produced by the collisions of He(2 3S) with CO and N2 were studied in the collision energy (ER range 100–200 meV. The rotational populations of the emitting states can be fitte by single Boltzmann temperatures (TR. The TR (320 ± 30 K) for the ν′ = 3 and 4 levels of the CO+ (A2Π) state are nearly independent of, or slightly increase with, ER, while TR for the CO+(B2Σ+, ν′ = 0) state increases rapidly with ER.The TR (430 ± 20 K) for the N2+(B2Σ+, ν′ = 0) state is nearly independent or slightly decreases with increasing ER. Interactions providing these trends are discussed.  相似文献   

20.
Mihajlović RP  Jaksić LN  Vajgand VV 《Talanta》1992,39(12):1587-1590
The application of hydrogen and deuterium ions obtained by anodic oxidation of hydrogen and deuterium dissolved in palladium, for the coulometric determination of bases (both individual and in mixtures) in propylene carbonate, is described. The current-potential curves at a palladium anode for supporting electrolyte indicator, titrated bases, hydrogen dissolved in palladium and deuterium dissolved in palladium showed that hydrogen and deuterium are oxidized at much less positive potentials than the oxidation potentials of other substances present in the solution. The generated H+ and D+ ions were used for the titration of bases (pyridine, quinoline, triethylamine, n-butylaniline, 2,2′-dipiridyl and aminopyrine) with visual and potentiometric detection. The oxidation of hydrogen and deuterium proceeded with 100% current efficiency. Two-component mixtures of bases (aliphatic + aromatic amine) were titrated successfully by using two indicators, Eosin and Crystal Violet. The relative error of the determination with respect to each individual base determination, was less than 2.5% for quantities of bases ranging from 1 to 3 mg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号