首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Results from a tandem mass spectrometry (MS/MS) study, obtained with a reverse-geometry mass spectrometer, of the unimolecular and collision-induced reactions of doubly charged free-base and metal containing alkyl-substituted porphyrins formed by electron ionization are reported. These doubly charged porphyrin ions dissociate to yield both singly and doubly charged product ions via a number of reactions. This article classifies the major reactions observed, illustrating each with the appropriate spectra. Supplementary data from the same porphyrins, acquired with a tandem quadrupole MS/MS instrument, are also presented. The potential utility of some of these reactions as new methods for porphyrin analysis is discussed.  相似文献   

2.
The interpretation of mass spectra is a key process during compound identification, and the combination of tandem mass spectrometry (MS/MS) with high-accuracy mass measurements may deliver crucial information on the identity of a compound. Obtaining accurate mass data of fragment ions in MS/MS reveals the particular problem of mass calibration when a lockmass, which is frequently used to obtain accurate masses in MS, is absent. An alternative technique is to recalibrate the MS/MS spectrum using a reference MS/MS spectrum acquired under the same conditions. We have tested and validated this approach using a hybrid quadrupole/orthogonal acceleration reflectron-type time-of-flight (TOF) mass spectrometer. The results were compared with those obtained under similar conditions on a Fourier transform ion cyclotron resonance (FT-ICR) instrument. We found that the mass accuracy observed with such an "external" recalibration on the TOF instrument in MS/MS is identical to what can be obtained on a similar instrument operating in one-dimensional MS mode using the lockmass technique. However, mass accuracy in both cases is one order of magnitude inferior to that obtained using FTMS, and also inferior to that observed using sector field MS when operated at comparable resolution. Nevertheless, for small (<200 Da) molecules, this mass accuracy was still sufficient to have the "true" elemental composition identified as the first hit in about 70% of all cases. It was possible to elucidate the fragmentation mechanism of eight azaheterocycles containing a pyridine moiety, where the accurate mass data from the TOF instrument allowed distinction between two alternative fragmentation pathways.  相似文献   

3.
A novel matrix-assisted laser desorption/ionisation quadrupole ion trap time-of-flight (MALDI QIT ToF) mass spectrometer has been used to analyse high mass peptide ions exceeding 2000 Da. Human adrenocorticotropic hormone (fragment 18-39) and oxidised bovine insulin chain B were utilised to evaluate the performance of the instrument both in MS and in MS/MS mode. Its ability to efficiently isolate ions and to fragment them using collisionally activated decomposition (CAD) has been demonstrated using mixtures diluted to the low-femtomole level on target. Additionally, multiple stage mass spectrometry (MS/MS/MS) provides a second-generation product ion spectrum in which new fragment ions are detected and new stretches of amino acids are identified.  相似文献   

4.
罗红霉素及其代谢物的电喷雾离子阱质谱研究   总被引:5,自引:1,他引:4  
采用电喷雾离子阱质谱法对人尿样中的罗红霉素及其10种代谢物进行了结构鉴定,利用质谱解析软件对其质谱裂解途径进行分析,发现它们的(+)ESI-MS2和(+)ESI-MS3质谱分别生成脱红霉糖和脱氨基糖碎片,并可见脱去C9位含氮烷基侧链和一系列质荷比相差18的脱水碎片离子,这些特征可用于罗红霉素及其结构类似物的体内代谢转化研究.  相似文献   

5.
Fragmentation mechanisms of trans-1,4-diphenyl-2-butene-1,4-dione were studied using a variety of mass spectrometric techniques. The major fragmentation pathways occur by various rearrangements by loss of H(2)O, CO, H(2)O and CO, and CO(2). The other fragmentation pathways via simple alpha cleavages were also observed but accounted for the minor dissociation channels in both a two-dimensional (2-D) linear ion trap and a quadrupole time-of-flight (Q-TOF) mass spectrometer. The elimination of CO(2) (rather than CH(3)CHO or C(3)H(8)), which was confirmed by an exact mass measurement using the Q-TOF instrument, represented a major fragmentation pathway in the 2-D linear ion trap mass spectrometer. However, the elimination of H(2)O and CO becomes more competitive in the beam-type Q-TOF instrument. The loss of CO is observed in both the MS(2) experiment of m/z 237 and the MS(3) experiment of m/z 219 but via the different transition states. The data suggest that the olefinic double bond in protonated trans-1,4-diphenyl-2-butene-1,4-dione plays a key role in stabilizing the rearrangement transition states and increasing the bond dissociation (cleavage) energy to give favorable rearrangement fragmentation pathways.  相似文献   

6.
We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity approximately 1 fmol) because the ion source is decoupled from the TOF mass analyzer by extensive gas collisions in the quadrupole stages of the instrument. The capacity to obtain side-by-side high quality ESI and MALDI mass spectra from a single proteolytic mixture greatly facilitates the identification of proteins and elucidation of their primary structures. Improved strategies for protein identification result from this ability to measure spectra using both ionization modes in the same instrument and to perform MS/MS on singly charged as well as multiply charged ions. Examples are provided to demonstrate the utility and performance of the modified instrument.  相似文献   

7.
This paper reports the use of an experimental matrix-assisted laser desorption/ionisation (MALDI) ion source fitted to a quadrupole time-of-flight (Q-Tof) mass spectrometer for the analysis of carbohydrates, particularly the N-linked glycans from glycoproteins. Earlier work on the Q-Tof instrument, using electrospray ionisation, gave excellent MS/MS spectra, particularly from the [M + Na]+ ions, but suffered from the major disadvantages that the signal was often split between singly and multiply charged ions and that sensitivity fell dramatically as the molecular weight of the carbohydrate rose. The MALDI ion source did not suffer from these problems and the instrument produced excellent MS and MS/MS spectra from small amounts of complex, underivatised glycans as well as those derivatised at the reducing terminus. Positive ion MS spectra of sialylated glycans recorded on the new instrument were much less complex than those recorded with a conventional MALDI-TOF instrument because of the absence of ions resulting from metastable (post-source decay, (PSD)) fragmentations occurring in the flight tube. However, considerable fragmentation by loss of sialic acid still occurred. MS/MS spectra of the [M + Na]+ ions from all compounds were almost identical to those recorded earlier with the electrospray-Q-Tof combination and far superior to MALDI-PSD spectra recorded with reflectron-TOF instruments. Spectra are shown for neutral and sialylated N-linked glycans from chicken ovalbumin, riboflavin binding protein, alpha1-acid glycoprotein, bovine fetuin and ribonuclease B, both as free glycans and as those derivatised at their reducing termini. The technique was applied to the structural determination of N-linked glycans from human secretory IgA and Apo-B 100 from human low-density lipoprotein.  相似文献   

8.
Recently, we demonstrated a new method, STEP (Statistical Test of Equivalent Pathways) analysis, which differentiates first-generation product ions (primary product ions) from second-generation product ions (secondary product ions) obtained in tandem mass spectrometric (MS/MS) experiments on a quadrupole ion trap mass spectrometer. The study presented here defines how to adapt the STEP method to a more routinely used mass analyzer, the triple quadrupole. New ion activation conditions were developed to adapt the STEP method to the triple quadrupole mass spectrometer using peptides and carbohydrates. The application of this method to the triple quadrupole is useful because it provides an efficient approach to differentiate primary and secondary ions on this instrument. Out of the total number of ions that were subjected to the STEP analysis, this method correctly identified 96% of ions as primary or secondary, indicating that this analysis is effective for carbohydrates and peptides undergoing collision-induced dissociation (CID) on a triple quadrupole mass spectrometer.  相似文献   

9.
A commercial matrix-assisted laser desorption/ionisation time-of-flight (MALDI-ToF) instrument equipped with a curved field reflectron (CFR) was modified in order to perform collision-induced dissociation (CID) on a variety of biomolecules. The incorporation of a high-resolution ion gate together with a collision cell within the field-free region allowed tandem mass analysis (MS/MS), without the necessity to decelerate the precursor ions prior to activation. The simultaneous detection of all product ions remained possible by using the CFR. To test the MS/MS performances, ACTH (fragment 1-17), a complex high mannose carbohydrate (Man)(8)(GlcNac)(2) and a lysophosphatidylcholine lipid (18:1) were analysed on the modified instrument. Direct comparison with the low-energy product ion spectra, acquired on a MALDI quadrupole ion trap (QIT) two-stage reflectron time-of flight (ReToF) mass spectrometer, showed significant differences in the types of product ions observed. The additional ions detected were a clear indication of the high-energy fragmentation processes occurring in the collision cell.  相似文献   

10.
In this communication, the structural analysis of six synthetic O-Linked amphiphilic cholesteryl polyethoxy neoglycolipids containing N-acetyl-D-glucosamine was performed by electrospray ionization mass spectrometry in the positive ion mode, with a QqTOF-MS/MS hybrid instrument. The MS/MS analyses provided evidence for the "in situ" formation, in the collision cell of the tandem mass spectrometer, of an unexpected and unique [C-glycoside]+ product ion, resulting from an ion-molecule reaction between the N-acetyl-D-glucosamine oxonium ion and the neutral cholesta-3,5-diene molecule. Quasi MS3 analysis of this ion resulted in the dissociation of the precursor [C-glycoside]+ ion, which produced the expected third generation N-acetyl-D-glucosamine oxonium and the protonated cholesta-3,5-diene product ions.  相似文献   

11.
The mass spectral fragmentation behavior of ten iridoid glucosides (IGs) has been studied using electrospray ionization (ESI), collision-induced dissociation (CID), and quadrupole time-of-flight tandem mass spectrometry (Q-TOF MS/MS). In the negative ESI mass spectra, the deprotonated [M-H](-) ion was observed for all of the ten IGs except gardoside methyl ester, while the formate adduct [M+HCOO](-) ion appeared to be favored by the presence of a methyl ester or a lactone group in the C-4 position when formic acid was added to the mobile phase. The CID MS/MS spectra of the [M-H](-) ions have been used for structural elucidation. Ring cleavages of the aglycone moiety have been observed in the MS/MS spectra, corresponding to (1,4)F(-), (2,6)F(-), (2,7)F(-), and (2,7)F(0) (-) ions, based on accurate mass measurements and the elemental compositions of the product ions. These characteristic ions gave valuable information on the basic structural skeletons. Furthermore, on the basis of the relative abundances of the fragment ions (1,4)F(-) and (2,7)F(-), different sub-classes, such as cyclopentane-type and 7,8-cyclopentene-type IGs, can be differentiated. Ring cleavage of the sugar moieties was also observed, yielding useful information for their characterization. In addition, the neutral losses, such as H(2)O, CO(2), CH(3)OH, CH(3)COOH, and glucosidic units, have proved useful for confirming the presence of functional substituents in the structures of the IGs. Based on the fragmentation patterns of these standard IGs, twelve IGs have been characterized in an extract of Hedyotis diffusa Willd. by means of ultra-performance liquid chromatography/Q-TOF MS/MS, of which six have been unambiguously identified and the other six have been tentatively identified.  相似文献   

12.
The fragmentation of six plumeran indole alkaloids (PIAs) previously isolated from Aspidosperma spruceanum has been investigated by electrospray ionization tandem mass spectrometry (ESI‐MS/MS) in the positive ion mode. The fragmentation pathways have been established on the basis of MS/MS experiments using fragment ions generated in‐source and deuterium‐labeled alkaloids as precursor ions and on the basis of accurate mass measurements. Our results demonstrated that the fragmentation routes observed for the protonated PIAs are essentially derived from a pericyclic reaction and from the opening of rings D and E, followed by 1,4‐hydrogen rearrangements. Product ions resulting from radical eliminations were also observed, contrary to the ‘even‐electron rule’. Our data reveals that some product ions from protonated PIAs provide crucial information for the characterization of the acyl substituent at N‐1, the methoxyl and hydroxyl groups at the aromatic moiety, and give evidence of an ether bridge between C‐18 and C‐21. The data reported here were used for the dereplication of these compounds in a stem bark methanolic extract of Aspidosperma spruceanum. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
We report negative-ion electrospray tandem mass spectrometric methods for structural characterization of cardiolipin (CL), a four-acyl-chain phospholipid containing two distinct phosphatidyl moieties, of which structural assignment of the fatty acid residues attached to the glycerol backbones performed by low-energy CAD tandem mass spectrometry has not been previously described. The low-energy MS2-spectra of the [M - H]- and [M - 2H]2- ions obtained with ion-trap or with tandem quadrupole instrument combined with ion-trap MS3-spectra or with source CAD product-ion spectra provide complete structural information for CL characterization. The MS2-spectra of the [M - H]- ions contain two sets of prominent fragment ions that comprise a phosphatidic acid, a dehydrated phosphatidylglycerol, and a (phosphatidic acid + 136) anion. The substantial differences in the abundances of the two distinct phosphatidic anions observed in the MS2-spectra of the [M -H]- ions lead to the assignment of the phosphatidyl moieties attached to the 1' or 3' position of central glycerol. Upon further collisional dissociation, the MS3-spectra of the phosphatidic anions provide information to identify the fatty acyl substituents and their position in the glycerol backbone. The MS2-spectra of the [M - 2H]2- ions obtained with TSQ or ITMS contain complementary information to confirm structural assignment. The applications of the above methods in the differentiation of cardiolipin isomers and in the identification of complex cardiolipin species consisting of multiple molecular structures are also demonstrated.  相似文献   

14.
The gingerols, including [6]-, [8]-, and [10]-gingerols, a series of chemical homologs differentiated by the length of their unbranched alkyl chains, have been identified as major active components in fresh ginger rhizome. The purpose of this study was to investigate the utility of ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) as an online tool to identify and quantify these compounds in raw or processed ginger rhizome samples. Negative mode electrospray ionization (ESI) was used in MS, MS/MS and MS(n) experiments in quadrupole ion trap instruments from two different manufacturers and in high-resolution and accurate mass MS and MS/MS experiments in a Fourier transform ion cyclotron resonance mass spectrometer to elucidate the ionization and fragmentation mechanisms of these compounds in these instruments. Positive mode ESI, which generated many more fragment ions in full scan MS even under gentle ionization conditions, was also used in LC/MS and MS/MS experiments and in direct infusion MS and MS/MS experiments. Consistent and predictable ionization and fragmentation behaviors were observed for all gingerols when analyzed in the same instrument. Instruments from different manufacturers, however, had different ionization mechanisms. The major difference between instruments was their ability to form covalent dimer adducts of the gingerols. Subsequent fragmentation patterns of the precursor ions were essentially identical. These results clearly demonstrate that LC/MS instruments produce data that cannot necessarily be replicated in other laboratories, especially if those laboratories do not have the same instrument model from the same manufacturer. This presents major problems for metabolite target analysis, metabolic profiling and metabolomics investigations, which would benefit from LC/MS mass spectrum libraries as they do from GC/MS mass spectrum libraries, because such libraries may not be valid across platforms.  相似文献   

15.
The results of the comparison of product-ion tandem mass (MS/MS) spectra recorded on three ion trap mass spectrometers, a triple quadrupole mass spectrometer and a Fourier transform ion cyclotron resonance mass spectrometer are reported. The spectra were recorded in accordance with a simple experimental protocol, which involved the collision-induced dissociation (CID) attenuation of the abundance of the [M+H]+ ion to between 10 and 50% of its original abundance.The degree of similarity between the spectra from four of the mass spectrometers was calculated off-line by comparing the five most abundant ions from the spectrum on each instrument. A percentage fit value (20% for each ion that matches) was calculated by comparing each spectrum against the spectra recorded for the same compound on each instrument. The percentage of the inter-library pairwise comparisons (total = 434) that matched to > or = 60% ranged from 64-89%, depending on the instrument pair. A blind trial was also undertaken using five unknown compounds resulting in 1670 pairwise comparisons with the library entries. The blind trial produced no false positives and correct identifications in all cases. The results of the study have established the basis for the construction of a transferable product-ion MS/MS library.  相似文献   

16.
To enable the development of a tandem mass spectrometry (MS/MS) based methodology for selective protein identification and differential quantitative analysis, a novel derivatization strategy is proposed, based on the formation of a "fixed-charge" sulfonium ion on the side-chain of a methionine amino acid residue contained within a protein or peptide of interest. The gas-phase fragmentation behavior of these side chain fixed charge sulfonium ion containing peptides is observed to result in exclusive loss of the derivatized side chain and the formation of a single characteristic product ion, independently of charge state or amino acid composition. Thus, fixed charge containing peptide ions may be selectively identified from complex mixtures, for example, by selective neutral loss scan mode MS/MS methods. Further structural interrogation of identified peptide ions may be achieved by subjecting the characteristic MS/MS product ion to multistage MS/MS (MS3) in a quadrupole ion trap mass spectrometer, or by energy resolved "pseudo" MS3 in a triple quadrupole mass spectrometer. The general principles underlying this fixed charge derivatization approach are demonstrated here by MS/MS, MS3 and "pseudo" MS3 analysis of side chain fixed-charge sulfonium ion derivatives of peptides containing methionine formed by reaction with phenacylbromide. Incorporation of "light" and "heavy" isotopically encoded labels into the fixed-charge derivatives facilitates the application of this method to the quantitative analysis of differential protein expression, via measurement of the relative abundances of the neutral loss product ions generated by dissociation of the light and heavy labeled peptide ions. This approach, termed "selective extraction of labeled entities by charge derivatization and tandem mass spectrometry" (SELECT), thereby offers the potential for significantly improved sensitivity and selectivity for the identification and quantitative analysis of peptides or proteins containing selected structural features, without requirement for extensive fractionation or otherwise enrichment from a complex mixture prior to analysis.  相似文献   

17.
A combination of negative ion nano-electrospray ionization Fourier-transform ion cyclotron resonance and quadrupole time-of-flight mass spectrometry was applied to analysis of oversulfation in glycosaminoglycan oligosaccharides of the chondroitin sulfate type from bovine aorta. Taking advantage of the high-resolution and high mass accuracy provided by the FT-ICR instrument, a direct compositional assignment of all species present in the mixture can be obtained. An oligosaccharide fraction containing mainly hexasaccharides exhibited different levels of sulfation, indicated by the presence of species with regular sulfation pattern as well as oversulfated oligosaccharides with one additional sulfate group. Oversulfation can be directly identified from the high-resolution/high mass accuracy FT-ICR mass spectra according to their specific isotopic fine structure. Location of sulfate groups was analyzed by Q-TOF MS and low-energy CID MS/MS. Tetrasulfated hexasaccharides were analyzed by use of collision-induced dissociation at variable collision energy for an unambiguous assignment of the attachment site of the sulfate groups by minimizing unspecific neutral losses. Cleavage of glycosidic bonds gave rise to B- and C-type ions and their respective complementary Y- and Z-type fragment ions.  相似文献   

18.
A detailed Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric (MALDI-TOF MS) investigation of polyethylene glycol (PEG), polypropylene glycol (PPG) and polyisobutylene (PIB) bis(imidazole-1-carboxylate) esters is reported. The MS spectra of PPG and PIBb is (imidazole-1-carboxylate) esters recorded in the reflectron mode showed the presence of two additional series of peaks compared to those recorded in the linear mode, while in the case of PEG bis(imidazole-1-carboxylate) only one additional peak series appeared in the reflectron MS spectra. These additional series were attributed to the formation of fragment ions by the loss of one and two end groups in the first field-free region of the instrument. The neutral losses for the three polymers were also supported by using the post-source decay method (PSD). The observation of decreasing mass difference between the adjacent peaks from two series of polymeric ions with the increase of oligomer mass indicates the presence of PSD ions in a reflectron MALDI spectrum. The relationship between the mass of the precursor ions and those of the PSD ions and neutral loss are also discussed.  相似文献   

19.
Multiply charged anions of some 30 species containing multiple carboxylic, sulphonic and/or phosphoric groups generated by ionspray were studied by using tandem mass spectrometry (MS/MS). Two trends emerged: (1) lower-charged ions are preferentially evaporated, and (2) for more highly charged ions, evaporability is a function of ion size. Triply and quadruply charged ions were observed for azo dyes with molecular masses in the 700-900 Dalton range. Daughter-ion mass spectra of selected multiply charged ions are presented.  相似文献   

20.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) has been coupled to a quadrupole time-of-flight mass spectrometer for the tandem mass spectrometric analysis of tryptic peptides of pig hemoglobin. Using FAIMS, low levels (fmol/microL) of multiply charged tryptic peptides were separated from relatively intense chemical background such that their tandem mass spectra (MS/MS) lacked many background-related fragment ions observed using a conventional ESI-QqTOFMS instrument. Substantial improvements in both first-order and tandem mass spectra were realized while maintaining approximately the same absolute intensities.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号