首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Major and trace elements (Na, Mg, Al, Si, P, K, Ca, Ti, Mn, Fe, Rb, Sr, Y, Zr, La, Ce, Pr, Nd, Sm, Gd, Dy, Th and U) in igneous rocks were assayed with fused lithium borate glass beads using X-ray fluorescence spectrometry. Low dilution glass beads, which had a 1:1 sample-to-flux ratio, were prepared for determination of rare earth elements. Complete vitrification of 1:1 mixture required heating twice at 1200 degrees C with agitation. Extra pure reagents containing determinants were used for calibrating standards instead of the rock standard. The calibration curves of the 23 elements showed good linearity. Furthermore, the lower limits of detection corresponding to three times the standard deviation for blank measurements were 26 mass ppm for Na2O, 6.7 for MgO, 4.5 for Al2O3, 4.5 for SiO2, 18 for P2O5, 1.1 for K2O, 4.0 for CaO, 3.9 for TiO2, 1.6 for MnO, 0.8 for Fe2O3, 0.5 for Rb, 0.2 for Sr, 0.4 for Y, 0.5 for Zr, 3.3 for La, 6.5 for Ce, 2.7 for Pr, 2.1 for Nd, 1.7 for Sm, 0.7 for Gd, 2.7 for Dy, 0.5 for Th, and 0.6 for U. Using the present method, we determined the contents of these 23 elements in four rhyolitic and granitic rocks from Japan.  相似文献   

2.
A method was developed for simultaneous determination of major (Ca), minor (Mg and Sr) and trace (Ba and U) elements in biocarbonates by inductively coupled plasma mass spectrometry (ICP-MS). The method precision (RSD%) is 0.73% for Ca, 0.77% for Mg, 0.59% for Sr, 2.02% for Ba, 1.13% for U, 0.67% for Mg/Ca, 0.27% for Sr/Ca, 2.06% for Ba/Ca and 1.23% for U/Ca. The ratio precision suggests that ICP-MS is satisfactory for obtaining multi-ratio data from biocarbonates. This technique was applied to 67 continuous coral samples.  相似文献   

3.
建立了用硝酸-高氯酸消解样品,电感耦合等离子体质谱法(ICP-MS)测定苦荞茶中铜、铅、镉、钴、镍的方法.方法具有灵敏度高、检出限低、精密度好、基体干扰少、准确可靠、快捷、简便的特点.各元素方法检出限(3SD,μg/L)分别为:铜0.009、铅0.023、镉0.015、钴0.022、镍0.035;方法精密度(RSD,n=12)分别为:铜2.5%~3.0%、铅2.1%~2.3%、镉3.0%~3.8%、钴2.5%~2.6%、镍1.5%~1.9%;各元素加标回收率分别为:铜95.0%~105.0%、铅95.0%~105.0%、镉98.0%~105.0%、钴95.0%~105.0%、镍95.0%~105.0%.在线用铑作为内标95.0%~105.0%.方法经国家一级标准物质验证,测定值与标准值吻合.应用于实际样品测定,结果满意.  相似文献   

4.
The preparation of new Certified Reference Materials (CRMs) of antarctic matrices forms the backbone of an ongoing project in the framework of the Italian National Program for Antarctic Research. The first CRM of this kind (MURST-ISS-A1 Antarctic Marine Sediment) is already available. The second phase focuses on the certification of antarctic krill, a small shrimp extremely abundant in the Southern Ocean. The total mass of krill available for this purpose is approximately 44 kg and results from the combination of three different catches (Ross Sea, Marguerite Bay and Livingston Island, respectively). The quantification of the following elements in the raw mass appears to be affordable by current analytical techniques, values being in the range of (in μg/g) 0.11–0.30 for As, 0.03–0.12 for Cd, 0.06–0.23 for Cr, 6.1–21 for Cu, 5.7–7.6 for Fe, 0.005–0.008 for Hg, 0.7–1.2 for Mn, 0.013– 0.077 for Ni, 0.04–0.57 for Pb and 12–16 for Zn. On the other hand, the average values ascertained in freeze-dried krill are as a rule one order of magnitude higher, i.e., (in μg/g), 3.2 for As, 0.6 for Cd, 1.8 for Cr, 75 for Cu, 61 for Fe, 0.025 for Hg, 4.6 for Mn, 0.7 for Ni, 2.1 for Pb and 81 for Zn. Information on the pretreatment of krill and details on the planned certification campaign are also given. Received: 10 June 1997 / Revised: 24 September 1997 / Accepted: 28 September 1997  相似文献   

5.
Chen SH  Chen YH 《Electrophoresis》1999,20(15-16):3259-3268
This review briefly discusses the use of capillary electrophoretic (CE) methods for the investigations of different aspects of pharmacokinetics. In most investigations, CE was the method of choice because of its unique features, including high resolving power for chiral or metabolite separation, small sample volume for pediatric pharmacokinetics or for cell-based investigations, in situ microdialysis sampling for rapid eliminations, low UV wavelength detection for nonderivatized analytes, fast and simplified sample processing for existing methods that require tedious sample preparation, or as a second method for verifications. Moreover, instrumental aspects of CE-based assays for pharmacokinetic studies, such as different modes of CE methods for analyzing biological samples, sample stacking for increasing detection sensitivity, and coupling techniques with microdialysis and mass spectrometry, are also discussed in this review. Furthermore, the advantages and limitations of CE methods as well as the future outlook for pharmacokinetic studies are summarized.  相似文献   

6.
高效液相色谱法测定藻类中的类胡萝卜素和叶绿素   总被引:16,自引:0,他引:16  
袁建平  张义明  史贤明  龚贤弟  陈峰 《色谱》1997,15(2):133-135
提出了用高效液相色谱法测定藻类中类胡萝卜素和叶绿素的方法。采用丙国等有机溶剂提取藻类中的类胡萝卜素和叶绿素,然后在反相C18柱上进行分离。流动相选用二氯甲烷/乙腈/甲醇/水(22.5:9.5:67.5:0.5),流速为1.0mL/min。用光度检测器检测报长为450um。叶黄素、α-胡萝卜素、β-胡萝卜素、叶绿素a和叶绿素b的平均回收串分别为99.1%,98.5%,99.4%,100.6%和99.9%,相对标准偏差分别为2.4%,5.6%,6.0%,4.1%和4.0%。  相似文献   

7.
More than 200 samples of marine products have been collected and analyzed for plutonium and almost 100 samples for americium around Hitachi, Tokai and Oarai in the pacific coast of Ibaraki prefecture. The data have shown that the concentration factor (CF) values for plutonium were 330 for bivalve, 770 for abalone (muscle) and 610 for brown algae. For americium, the CF was calculated as 2400 for bivalve, 1000 for abalone (muscle) and 420 for brown algae.  相似文献   

8.
In this article, we estimate the costs of using alternative feedstocks to produce ethanol in a 40 million-gal facility in California’s San Joaquin Valley. Feedstocks include corn imported from Midwestern states and locally grown agricultural products such as corn, grapes, raisins, oranges, and other tree fruits. The estimated feedstock costs per gallon of ethanol include $0.92 for Midwestern corn, $1.21 for locally grown corn, $6.79 for grapes, $3.36 for raisins, $3.92 for citrus, and $1.42 for other tree fruit. Adjusting for coproduct values lowers the estimated net feedstock costs to $0.67/gal of ethanol for Midwestern corn, $0.96 for locally grown corn, $6.53 for grapes, and $3.30 for raisins. We also examine the potential increases in net revenue to raisin producers, made possible by having an alternative outlet available for selling surplus raisins.  相似文献   

9.
Liquid chromatography was used for the quantification of aflatoxin B1-oxime (AFB1-oxime). The yield of AFB1-oxime in the reaction mixture was 89%, while after purification on silica gel it was 72%. LC analysis of the reaction mixture after silica gel fractionation revealed a retention time of 0.84 min for AFB1-oxime, 8.42 min for AFB1, 1.21 min for unknown 1 and 1.61 min for unknown 2. UV-visible analysis of the reaction mixture after silica gel fractionation showed a lambda(max) of 269 and 361 nm for AFB1-oxime, 263 and 360 nm for AFB1, 273 nm for unknown 1 and 275 nm for unknown 2. Excitation and emission wavelengths were found to be 269 and 368/438 nm for AFB1-oxime, 359/424 nm for AFB1, 270 and 367/450 nm for unknown 1 and 273 and 416/447 nm for unknown 2. The method may find versatile application in monitoring reactions for the preparation of oximes of various analytes for the synthesis of their immunogens.  相似文献   

10.
A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.  相似文献   

11.
A method for simultaneous ICP-MS determination of 13 elements in three types of honey from Poland is described. The method was validated, and the uncertainty budget was set up. The results obtained for the relative expanded uncertainties U rel (k = 2) were 15.1% for Al, 18.6% for B, 18.8% for Ba, 7.9% for Ca, 24.4% for Cd, 7.24% for Cu, 7.9% for K, 4.8% for Mg, 8.3% for Mn, 12.7% for Na, 14.9% for Ni, 12.5% for Pb and 13.4% for Zn. Traceability of the measurement results was established based on the use of the corn flour CRM INCT-CF-3 and the apple leaves CRM SRM 1515 and by analyzing spiked samples. Recovery rates between 94% (Zn) and 107% (Na) were found. The detection limits of all elements studied showed the suitability of the procedure for routine analyses. Summarizing it can be concluded that the described analytical procedures to measure the mass fractions of 13 elements in honey samples with established traceability and evaluated uncertainty allow to obtain reliable and internationally comparable results.  相似文献   

12.
In this study, sponsored by PepsiCo Inc., a method was validated for measurement of 11 pesticide residues in soft drinks and sports drinks. The pesticide residues determined in this validation were alachlor, atrazine, butachlor, isoproturon, malaoxon, monocrotophos, paraoxon-methyl, phorate, phorate sulfone, phorate sulfoxide, and 2,4-dichlorophenoxyacetic acid (2,4-D) when spiked at 0.100 microg/L (1.00 microg/L for phorate). Samples were filtered (if particulate matter was present), degassed (if carbonated), and analyzed using liquid chromatography with tandem mass spectrometry. Quantitation was performed with matrix-matched external standard calibration solutions. The standard curve range for this assay was 0.0750 to 10.0 microg/L. The calibration curves for all agricultural residues had coefficient of determination (r2) values greater than or equal to 0.9900 with the exception of 2 values that were 0.9285 and 0.8514. Fortification spikes at 0.100 microg/L (1.00 microg/L for phorate) over the course of 2 days (n=8 each day) for 3 matrixes (7UP, Gatorade, and Diet Pepsi) yielded average percent recoveries (and percent relative standard deviations) as follows (n=48): 94.4 (15.2) for alachlor, 98.2 (13.5) for atrazine, 83.1 (41.6) for butachlor, 89.6 (24.5) for isoproturon, 87.9 (24.4) for malaoxon, 96.1 (9.26) for monocrotophos, 101 (25.7) for paraoxon-methyl, 86.6 (20.4) for phorate, 101 (16.5) for phorate sulfone, 93.6 (25.5) for phorate sulfoxide, and 98.2 (6.02) for 2,4-D.  相似文献   

13.
Thirteen laboratories participated in an interlaboratory method performance (collaborative) study on a method for the determination of arsenic, cadmium, mercury, and lead by inductively coupled plasma/mass spectrometry (ICP/MS) after pressure digestion including the microwave heating technique. Prior to the study, the laboratories were able to practice on samples with defined element levels (pretrial test). The method was tested on a total of 7 foodstuffs: carrot puree, fish muscle, mushroom, graham flour, simulated diet, scampi, and mussel powder. The elemental concentrations in mg/kg dry matter (dm) ranged from 0.06-21.4 for As, 0.03-28.3 for Cd, 0.04-0.6 for Hg, and 0.01-2.4 for Pb. The materials used in the study were presented to the participants as blind duplicates, and the participants were asked to perform single determinations on each sample. The repeatability relative standard deviations (RSDr) for As ranged from 3.8 to 24%, for Cd from 2.6 to 6.9%, for Hg from 4.8 to 8.3%, and for Pb from 2.9 to 27%. The reproducibility relative standard deviations (RSDR) for As ranged from 9.0 to 28%, for Cd from 2.8 to 18%, for Hg from 9.9 to 24%, and for Pb from 8.0 to 50%. The HorRat values were less than 1.5 for all test samples, except for the determination of Pb in wheat flour at a level close to the limit of quantitation (0.01 mg/kg dm). The study showed that the ICP/MS method is satisfactory as a standard method for elemental determinations in foodstuffs.  相似文献   

14.
建立了顶空固相微萃取(HSSPME)-气相色谱(GC)-质谱(MS)联用测定纺织品中甲苯、4-乙烯基环己烯、苯乙烯、萘和1-苯基环己烯5种挥发性有机物(VOCs)的分析方法。选择聚二甲基硅氧烷(PDMS)作为萃取涂层,优化了SPME的萃取条件,包括平衡时间、萃取时间、萃取温度、顶空体积、离子强度、搅拌速度、解吸温度和时间以及GC—MS仪器条件。对于甲苯、4-乙烯基环己烯、苯乙烯、萘和1-苯基环己烯方法线性范围分别为0.087~870、3.32~3320、2.28~2280、0.015~150和0.050~50.0ng/g;检出限分别为0.005、0.042、0.670、0.008和0.011ng/g。实际样品加标回收率在80.1%~122%之间,RSD在0.8%~8.6%之间。方法符合纺织品中痕量VOCs的快速分析要求。  相似文献   

15.
Dexmedetomidine (Dex) (Precedex) is a novel lipophilic imidazole derivative with a high affinity for alpha-2 adrenergic receptors, which exhibits sedative, analgesic-sparing, and sympatholytic properties. The pharmacological effects and therapeutic benefits of this drug have drawn continued interest from the medical community. Here we report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method to simultaneously measure the concentrations of dexmedetomidine and its glucoronide metabolites, G-Dex-1 and G-Dex-2, in human plasma samples. A solid-phase extraction method was developed to effectively extract Dex, G-Dex-1, and G-Dex-2 from plasma matrices. An isocratic chromatographic method was developed to achieve baseline separation of G-Dex-1 and G-Dex-2. The linear dynamic range evaluated was 19.08-1908.56 pg/mL for Dex, 65.17-6518.17 pg/mL for G-Dex-1, and 29.42-2943.28 pg/mL for G-Dex-2. The linear correlation coefficient (r) ranged from 0.9944-0.9979 for Dex, from 0.9966-0.9984 for G-Dex-1, and from 0.9939-0.9966 for G-Dex-2. The intra-assay coefficient of variation (CV) was between 2.5-12.5% for Dex, between 5.2-11.0% for G-Dex-1, and between 3.5-12.1% for G-Dex-2. The inter-assay precision of QC samples give % CV ranges from 6.5-9.3% for Dex, from 7.1-10.6% for G-Dex-1, and from 8.2-10.2% for G-Dex-2. The inter-assay accuracies ranged from 102.0-109.3% for Dex, from 95.4-105.6% for G-Dex-1, and from 98.7-115.0% for G-Dex-2.  相似文献   

16.
Dibenzomethanopentacene (DBMP) is shown to be a useful structural component for making Polymers of Intrinsic Microporosity (PIMs) with promise for making efficient membranes for gas separations. DBMP-based monomers for PIMs are readily prepared using a Diels–Alder reaction between 2,3-dimethoxyanthracene and norbornadiene as the key synthetic step. Compared to date for the archetypal PIM-1, the incorporation of DBMP simultaneously enhances both gas permeability and the ideal selectivity for one gas over another. Hence, both ideal and mixed gas permeability data for DBMP-rich co-polymers and an amidoxime modified PIM are close to the current Robeson upper bounds, which define the state-of-the-art for the trade-off between permeability and selectivity, for several important gas pairs. Furthermore, long-term studies (over ≈3 years) reveal that the reduction in gas permeabilities on ageing is less for DBMP-containing PIMs relative to that for other high performing PIMs, which is an attractive property for the fabrication of membranes for efficient gas separations.  相似文献   

17.
建立了加速溶剂萃取(ASE)-气相色谱-串联质谱(GC-MS/MS)法用于测定茶叶中10种吡唑和吡咯类农药残留。ASE萃取压力为1.03×107 Pa,萃取温度为100 ℃,萃取时间为5 min,萃取溶剂为乙酸乙酯-正己烷(1:1, v/v)。萃取循环1次,萃取液浓缩后用Envi-Carb/PSA固相萃取小柱净化,乙酸乙酯-正己烷(1:1, v/v)洗脱。洗脱液浓缩后,用正己烷定容,供GC-MS/MS测定,外标法定量。方法的准确度和精密度均符合残留分析要求。方法的定量限(LOQ)分别为唑螨酯0.003 mg/kg、氟虫腈硫化物0.001 mg/kg、氟虫腈0.002 mg/kg、氟虫腈砜化物0.005 mg/kg、溴虫腈0.002 mg/kg、氟硅唑0.006 mg/kg、野燕枯0.001 mg/kg、吡草醚0.001 mg/kg、吡螨胺0.0003 mg/kg、唑虫酰胺0.005 mg/kg。方法的灵敏度能满足各国有关农药的残留限量要求。  相似文献   

18.
Normal coordinate analysis is an important tool in studying the structure, dynamics, and physical properties of polymer systems. In this article the capabilities of normal coordinate analysis (NCA) are explored in some detail. The use of the eigenvalues and eigenvectors from NCA is catalogued for a wide variety of purposes: for assigning or interpreting polymer spectra, for structural determination, for constructing force fields, for computing heat capacity and other thermodynamic properties, and for computing other physical properties. Examples are given for crystals, melts, and amorphous systems. Also described are methods for characterizing the normal mode vectors that are especially useful for larger systems, in which a large amount of data must be analyzed or where visualization or animation fails. Finally, a recently developed method for eliminating negative eigenvalues in systems with tens of thousands of atoms, trajectory averaging, is presented. Also described are several advances in numerical linear algebra for speeding up the diagonalization phase and for computing physical properties without requiring full diagonalization of the Hessian matrix.  相似文献   

19.
In this work, an isotope dilution method for determination of selected acidic herbicides by high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was developed for surface water samples. Average percent recoveries of native analytes were observed to be between 70.8 and 93.5% and average recoveries of labeled quantification standards [(13)C(6)]2,4-D and [(13)C(6)]2,4,5-T were 85.5 and 101%, respectively. Using this method, detection limits of 0.05 ng/L for dicamba, MCPA, MCPP, and triclopyr, and 0.5 ng/L for 2,4-D were routinely achieved. The method was applied to measuring the concentration of these analytes in surface water samples collected from five sampling locations in the Lower Fraser Valley region of British Columbia, Canada. All of the herbicides monitored were detected at varying levels in the surface water samples collected. The highest concentrations detected for each analyte were 345 ng/L for 2,4-D, 317 ng/L for MCPA, 271 ng/L for MCPP, 15.7 ng/L for dicamba, and 2.18 ng/L for triclopyr. Average detection frequencies of the herbicides were 95% for MCPA, 80% for MCPP, 70% for dicamba, 65% for 2,4-D, and 46% for triclopyr. Seasonal variations of herbicide levels are also discussed.  相似文献   

20.
A liquid chromatographic (LC) method for the determination of fumonisins B1 (FB1) and B2 (FB2) in corn and corn flakes was collaboratively studied by 23 laboratories, which analyzed 5 blind duplicate pairs of each matrix to establish the accuracy, repeatability, and reproducibility characteristics of the method. Fumonisin levels in the corn ranged from <0.05 (blank) to 1.41 microg/g for FB1 and from <0.05 to 0.56 microg/g for FB2, whereas in the corn flakes they ranged from <0.05 to 1.05 microg/g for FB1 and from <0.05 to 0.46 microg/g for FB2. The method involved double extraction with acetonitrile-methanol-water (25 + 25 + 50), cleanup through an immunoaffinity column, and LC determination of the fumonisins after derivatization with o-phthaldialdehyde. Relative standard deviations for the within-laboratory repeatability (RSDr) of the corn analyses ranged from 19 to 24% for FB1 and from 19 to 27% for FB2; for the corn flakes analyses, RSDr ranged from 9 to 21 % for FB1 and from 8 to 22% for FB2. Relative standard deviations for the between-laboratories reproducibility (RSDR) of the corn analyses ranged from 22 to 28% for FB1 and from 22 to 30% for the FB2; for corn flakes analyses, RSDR ranged from 27 to 32% for FB1 and from 26 to 35% for FB2. Mean recoveries of FB1 and FB2 from corn spiked with FB1 at 0.80 microg/g and with FB2 at 0.40 microg/g were 76 and 72%, respectively; for corn flakes spiked at the same levels recoveries were 110 and 97% for FB1 and FB2, respectively. HORRAT ratios for the analyses of corn ranged from 1.44 to 1.53 for FB1 and from 0.96 to 1.48 for FB2, whereas for corn flakes they ranged from 1.60 to 1.82 for FB1 and from 1.39 to 1.68 for FB2.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号