共查询到20条相似文献,搜索用时 15 毫秒
1.
Carroccio S Rizzarelli P Puglisi C 《Rapid communications in mass spectrometry : RCM》2000,14(16):1513-1522
Matrix-assisted laser desorption/ionisation time-of-flight (MALDI-TOF) and the off-line size exclusion chromatography matrix-assisted laser desorption/ionisation (SEC/MALDI) method has been applied to the structural characterisation and the molar mass (MM) determination of a series of biodegradable copolyesters synthesised by high temperature melt polycondensation reaction, and of two commercial copolyesters with the trade name Bionolle. The MALDI-TOF spectra of these copolymers showed the presence of cyclic oligomers in the lower mass region, in accord with expectations from polycondensation kinetics, and the presence of all linear species expected from their method of synthesis. The presence of unexpected linear species with olefin and carboxyl as end groups suggested the occurrence of undesirable thermal degradation processes during the melt polycondensation reaction. The absolute average molar masses obtained by the SEC-MALDI method turned out to be lower, by a factor of about two for succinate/adipate copolymers, and by a factor of three for succinate/sebacate copolymers, with respect to those computed by using polystyrene standards in SEC. Furthermore, the MALDI-TOF spectra of SEC fractions allowed not only the detection of linear and cyclic oligomers contained in these samples, but also the simultaneous determination of the average molar mass of both cyclic and linear oligomers. Due to the smaller hydrodynamic volume of cyclic chains with respect to linear ones, the ratio (M( cycle)/M( linear))( Ve) at a fixed elution volume was found to be 1.25, in good agreement with the theoretical value of 1.24. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
2.
Marcela M. Cordero Timothy J. Cornish Robert J. Cotter 《Journal of the American Society for Mass Spectrometry》1996,7(6):590-597
Atandem reflectron time-of-flight mass spectrometer developed in our laboratory provides a unique opportunity to investigate the collision-induced dissociation of fullerene ions formed by matrix-assisted laser desorption/ionization (MALDI). Specifically, this opportunity arises from the ability to utilize high energy collisional activation (normally available only on tandem sector instruments by using continuous ionization techniques) for ions formed by pulsed laser desorption, whereas most MALDI time-of-flight instruments record product ion mass spectra of ions formed by metastable or postsource decay. In this study we investigate the products of mass-selected and collisionally activated C 60 + and C 70 + ions by using different target gases over a range of target gas pressures. In general, heavier target gases produce more extensive fragmentation and improve the mass resolution of lower mass ionic products because a greater portion of these ions are formed by single collisions. Additionally, the tandem time-of-flight instrument utilizes a nonlinear (curved-field) reflectron in the second mass analyzer that enables high energy collision-induced dissociation spectra to be recorded without scanning or stepping the reflectron voltage. 相似文献
3.
The parameters affecting the fractionation performance in size-exclusion chromatography (SEC) of broad polymer samples were investigated. Some equations were derived which enable the prediction of polydispersity (PD) in an SEC fraction. Good agreements were obtained between the calculated data and the experimental values. Based on these equations, SEC fractionation conditions were optimized. In the off-line SEC-matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS), two different modes can be employed, i.e., using MALDI-MS to provide an absolute calibration curve for SEC, or using SEC as a sample preparation step for MALDI-MS measurements. It was demonstrated that it is more reliable to use the latter combination, because most problems inherent in SEC can be circumvented. Some guidelines for the optimization of off-line SEC fractionation-MALDI-TOF-MS were given. It was found that under optimized conditions normally only a few SEC fractions are already sufficient to separate a highly polydisperse sample into portions of low PD that can accurately be measured by MALDI-TOF-MS. 相似文献
4.
Talat Yalcin David C. Schriemer Liang Li 《Journal of the American Society for Mass Spectrometry》1997,8(12):1220-1229
An analytical method based on matrix-assisted laser desorption ionization (MALDI) time-of-flight mass spectrometry has been developed to provide information on oligomer structure, average molecular weight, and molecular weight distributions of polydienes (e.g., polybutadiene and polyisoprene), an important class of industrial polymers. This MALDI method involves the use of all-trans-retinoic acid as the matrix, copper (II) nitrate as the cationization reagent, and tetrahydrofuran as the solvent. The incorporation of this copper salt generates Cu+ adducts with the polymer chains. It also improves the signal strength and extends the upper mass range when used with all-trans-retinoic acid, as compared to silver nitrate. With this formulation, it is demonstrated that polybutadienes of narrow polydispersity with masses up to 300,000 u and polyisoprenes of narrow polydispersity with masses up to 150,000 u can be analyzed. The upper molecular weight limit is set by the requirement of using higher matrix-to-polymer ratios with increasing polymer molecular weight, to the point where the instrument can no longer detect the small quantity of polymer present in the matrix host. It is also shown that this sample preparation generates previously unreported adduction behavior. The practical implications of this adduction behavior on polymer structural analysis, accuracy of molecular weight determination, and the upper molecular weight limit of oligomer resolution are discussed. It is illustrated that, in a linear time-lag focusing MALDI instrument, oligomer resolution can be obtained for polydienes with molecular weights up to 24,000, providing structural confirmation of the end-groups and the repeat unit. The average molecular weights of a number of polydienes of narrow polydispersity determined by MALDI are compared to those obtained by gel permeation chromatography, and discrepancies are noted. 相似文献
5.
V. G. Zaikin R. S. Borisov N. Yu. Polovkov V. V. Lobodin 《Russian Chemical Bulletin》2007,56(7):1369-1373
Synthetic copolyamides based on aliphatic diamines (1,3-propanediamine and 1,4-butanediamine) and dichlorides of aliphatic
carboxylic acids (adipic and sebacic acid dichlorides) were investigated using time-of-flight matrix assisted laser desorption/ionization
mass spectrometry. Their mass spectra showed peaks for cationized (Na+ and K+) and protonated (less intense peaks) oligomers with NH2-NH2, NH2-COOH, or COOH-COOH end groups. No cyclic oligomers were detected in the samples. The compositions of oligomers were determined,
and the relative reactivities of homologous comonomers in polycondensation were estimated.
Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 7, pp. 1320–1324, July, 2007. 相似文献
6.
Bashir S Derrick PJ Critchley P Gates PJ Staunton J 《European journal of mass spectrometry (Chichester, England)》2003,9(1):61-70
Application of matrix-assisted laser desorption/ionization (MALDI) to the analysis of dextran and dextrin derivatives, specifically glucose saccharides, by time-of-flight (TOF) mass spectrometry has been reported. MALDI-TOF analysis was carried out on alpha-, beta- and gamma-cyclodextrin, two O-methylated-beta-cyclodextrins of differing degrees of substitution (DS) and dextrans (a linear glucose saccharide), as pure and doped solutions and as mixtures of two or more of these. Doping was carried out with trace amounts of inorganic salts. The purpose of the analysis of the cyclodextrins was to determine whether they would form inclusion complexes with the various cations added, or whether less specific cation addition/exchange was occurring either prior to desorption or in the gas phase. 相似文献
7.
Peter Juhasz Catherine E. Costello 《Journal of the American Society for Mass Spectrometry》1992,3(8):785-796
Underivatized and permethylated gangliosides have been studied by the matrix-assisted laser desorption (MALD) ionization technique. The samples investigated included commercially available and highly purified gangliosides from the human brain containing up to five sialic acid residues. Several permethylated gangliosides have also been studied, and MALD has proven successful in analyzing multicomponent mixtures of glycolipids with different fatty acyl residues. During the studies a variety of matrix and wavelength combinations have been tested in both the positive and negative ion modes. The best results have been obtained with the matrices 2,5-dihydroxybenzoic acid, 4-hydrazinobenzoic acid, 1,5-diaminonaphthalene, and 6-aza-2-thiothymine. Negative ion mass spectra of the underivatized gangliosides have always been of better quality than the positive ion mass spectra, exhibiting better signal-to-noise ratio, better resolution, less fragmentation, and less adduct formation with Na+ and K+. With increasing number of sialic acid substituents the molecular ion region became less and less resolvable, leading to broadened peaks even in the negative ion mode. Fragmentation could frequently be observed in the negative ion mode, and it was pronounced in the positive ion mode. The major fragmentation pathways corresponded to loss of sialyl group(s) and to decarboxylation of one of the sialyl residues. For underivatized gangliosides the typical sample amount used was 10–20 pmol. Permethylation led to a significant improvement in sensitivity (two orders of magnitude); the detection limit of permethylated gangliosides was about 10 fmol. The higher stability of the permethylated compounds was indicated by the fact that positive ion mass spectra exhibited only a marginal extent of fragmentation. 相似文献
8.
Zhao Z Xiong S Liu X Xin B Wang G 《European journal of mass spectrometry (Chichester, England)》2003,9(3):203-211
We report the application of matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF) mass spectrometry, with delayed extraction in the reflectron mode, for the characterization of low molecular weight dendrimers. 20 dendrimer samples were measured and 4 typical dendrimers, as examples, are discussed in detail. Several factors that affect the analysis including the matrices used, the concentrations of sample, the solvents and cationization reagent used, were investigated in detail. Experimental results indicate that the type of solvent can greatly influence exact mass measurement. However, sample preparation is generally not very critical for dendrimer analysis using MALDI-ToF since many kinds of matrices and a wide range of sample concentrations can be used efficiently. In addition, the Cs(+) ion can be used to enhance the efficiency of cationization. Some reasons for this behavior are discussed on the basis of results of calculations using Gaussian94 software (a connected system of programs for performing a variety of semi-empirical and ab initio molecular orbital (MO) calculations). 相似文献
9.
Armirotti A Benatti U Miele M Damonte G 《Rapid communications in mass spectrometry : RCM》2005,19(23):3531-3538
Taxanes are biologically active compounds that have been extensively used in pharmacology for their powerful anticancer properties. High specificity and low level sensitivity for analysis of these compounds have been obtained with reversed-phase high-pressure liquid chromatography/mass spectrometry (RP-HPLC/MS), but the number of applications of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for low molecular weight analytes is rapidly growing. A new MALDI-MS approach for the rapid screening of a variety of taxanes and a tandem mass spectrometric (MS/MS) analysis of the most important and diagnostic taxane fragmentation pathways are proposed. A solid-phase extraction method followed by preliminary quantification is also reported. 相似文献
10.
Hollemeyer K Velagapudi VR Wittmann C Heinzle E 《Rapid communications in mass spectrometry : RCM》2007,21(3):336-342
We describe a novel method for the determination of the concentration and labeling degree of ethanol originating from 1-13C-labeling experiments. This method is suitable for high-throughput metabolic flux analysis because of the possible parallel sample preparation and fast final analysis using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). In a closed vial containing culture supernatant, ethanol is enzymatically oxidized to acetaldehyde. The acetaldehyde formed evaporates and is readily trapped in a second enclosed but open vial containing acidified 2,4-dinitrophenylhydrazine (DNPH). The 2,4-acetaldehyde dinitrophenylhydrazone (Ac-DNPH) that is formed is insoluble under these conditions. This leads to a constant conversion rate of the acetaldehyde produced from ethanol after 14 h minimum incubation time. MALDI-TOFMS was used to quantify the formed Ac-DNPH with [13C2]-ethanol as internal standard. The relative signal intensities of the unlabeled ethanol derivative as well as of [1-13C]-ethanol were linearly related to the ethanol concentration within a range of 1 to 50 mM with a limit of detection of 0.6 mM, a range which is sufficient for flux analysis in microtiter plate fermentation experiments. The method allows the estimation of the [1-13C]-ethanol originating from 1-13C-labeling experiments of Saccharomyces cerevisiae strains. In experiments where the expected flux range was exceeded, unlabeled ethanol was determined with a linear range from 30 to 500 mM. Ethanol quantification using this method was compared with enzymatic analysis and exhibited differences of less than 3.3% on average. Comparison of flux partitioning ratios between glycolysis and the pentose-phosphate pathway (PPP) based on MALDI-TOFMS and gas chromatography (GC)/MS methods showed good agreement, with differences for ethanol and alanine labeling of only 4.3%. 相似文献
11.
Al-Saad KA Zabrouskov V Siems WF Knowles NR Hannan RM Hill HH 《Rapid communications in mass spectrometry : RCM》2003,17(1):87-96
Ionization and prompt fragmentation patterns of triacylglycerols, phospholipids (PLs) and galactolipids were investigated using matrix-assisted laser desorption/ionization (MALDI). Positive ions of non-nitrogen-containing lipids appeared only in the sodiated form, while nitrogen-containing lipids were detected as both sodiated and protonated adducts. Lipids containing acidic hydroxyls were detected as multiple sodium adducts or deprotonated ions in the positive and negative modes, respectively, with the exception of phosphatidylcholines. The positive MALDI spectra of triacylglycerols contained prompt fragments equivalent to the loss of RCOO(-) from the neutral molecules. Prompt fragment ions [PL-polar head](+) were observed in the positive MALDI spectra of all phospholipids except phosphatidylcholines. The phosphatidylcholines produced only a minor positive fragment corresponding to the head group itself (m/z 184). Galactolipids did not undergo prompt fragmentation. Post-source decay (PSD) was used to examine the source of prompt fragments. PSD fragment patterns indicated that the lipid prompt fragment ions did not originate from the observed molecular ions (sodiated or protonated), and suggested that the prompt fragmentation followed the formation of highly unstable, probably protonated, precursor ions. Pathways leading to the formation of prompt fragment ions are proposed. 相似文献
12.
Falkenhagen J Jancke H Krüger RP Rikowski E Schulz G 《Rapid communications in mass spectrometry : RCM》2003,17(4):285-290
Liquid chromatography in combination with spectroscopic methods like matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) or nuclear magnetic resonance (NMR) spectroscopy is a powerful method to characterize silsesquioxanes and silsesquioxane mixtures. As new examples, the formation of silsesquioxyl-substituted silsesquioxanes [(n-octyl)(7)(SiO(1.5))(8)](2)O and [(n-octyl)(7)(SiO(1.5))(8)O](2)[(n-octyl)(6)(SiO(1.5))(8)] as well as the cage rearrangement of octa-[(n-heptyl)silsesquioxane] to larger structures [(n-heptyl)SiO(1.5))](n) up to n=28 are shown. 相似文献
13.
Chen LC Asakawa D Hori H Hiraoka K 《Rapid communications in mass spectrometry : RCM》2007,21(24):4129-4134
Visible matrix-assisted laser desorption/ionization (VIS-MALDI) was performed using 2-amino-3-nitrophenol as matrix. The matrix is of near-neutral pH, and has an optical absorption band in the near-UV and visible region. A frequency-doubled Nd:YAG laser operated at 532 nm wavelength was used for matrix excitation and comparisons were made with a frequency-tripled Nd:YAG laser (355 nm). Visible and ultraviolet (UV)-MALDI produce similar mass spectra for peptides, polymers, and small proteins with comparable sensitivities. Due to the smaller optical absorption coefficient of the matrix at 532 nm wavelength, the optical penetration depth is larger, and the sample consumption per laser shot in VIS-MALDI is higher than that of UV-MALDI. Nevertheless, VIS-MALDI using 2-amino-3-nitrophenol as matrix may offer a complementary technique to the conventional UV-MALDI method in applications where deeper laser penetration is required. 相似文献
14.
Fukuo T Monjushiro H Hong Hg Haga Ma Arakawa R 《Rapid communications in mass spectrometry : RCM》2000,14(14):1301-1306
Self-assembled monolayers (SAMs) of three ruthenium complexes, [Ru(L)(2)](PF(6))(2), [Ru(L)(tpyPO(3))](PF(6))(2), and [Ru(L18)(tpyPO(3))](PF(6))(2), were prepared on evaporated gold films on glass or stainless steel plates; where L = 2, 6-bis(benzimidazoyl)pyridine, tpyPO(3) = 2,6-bis(2,2':6', 2"-terpyridyl)pyridine phosphanate, and L18 = 2, 6-bis(N-octadecylbenzimidazoyl)pyridine. Structures of these SAM complexes were studied by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The SAMs were either prepared by direct binding of Ru-complexes to Au films by alkanethiol or by the multilayer method. In the multilayer method 1,4-thiobutylphosphate was used to form a base layer on an Au film, and the base layer was then chemically bridged to the Ru-complexes by zirconium phosphate. MALDI-TOFMS of SAM1, that had been prepared by direct binding of [Ru(L)(2)](PF(6))(2) to the Au film by an octanethiol group, showed cleavage at the S-Au linkages and elimination of the counter anion to yield a molecular ion and its dimeric ion. On the other hand, SAM2 and SAM3, which had been prepared by bridging Ru-complexes [Ru(L)(tpyPO(3))](PF(6))(2) or [Ru(L18)(tpyPO(3))](PF(6))(2) to the base layers with zirconium phosphate, showed dissociation from the base layers and elimination of the counter anion to give ions of the Ru complex molecules and their fragmentation ions. No molecular ion containing the base layer resulting from the S-Au bond cleavage was observed. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
15.
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate. Eleven kinds of particle, Al, Mn, Mo, Si, Sn, SnO2, TiO2, W, WO3, Zn and ZnO, were evaluated. The analyte was mixed with a metal or metal oxide powder (inorganic matrix) with particle diameter of tens of micrometers and liquid dispersant, followed by application to the sample target. Using a commercial MALDI-TOFMS instrument equipped with an internal 337 nm pulsed nitrogen laser, the analytes, PEG 200 and methyl stearate, were ionized as the alkali metal ion adducted molecules [M+Na]+ or [M+K]+ when the inorganic matrices Mn, Mo, Si, Sn, TiO2, W, WO3, Zn or ZnO were used. In the case of an Al matrix, PEG 200 was ionized as [M+K]+, whereas methyl stearate was ionized as [M+H]+ and [M+Al]+. These particles have potential as the matrix for MALDI. During our examination, however, only SnO2 particles did not ionize either PEG 200 or methyl stearate. Based on our protocol, when TiO2 powder was suspended with liquid paraffin, PEG 200 and methyl stearate gave their MALDI-TOF mass spectra with the lowest background noise and highest intensity. TiO2 powder seemed to be a broad potential matrix for low molecular mass polar or non-polar analytes. The results suggested that bulk particles caused rapid heating/vaporization processes and ionized analyte molecules under irradiation with a pulsed UV laser. The present method can be readily applied to obtain the low background noise MALDI-TOF mass spectra of small-sized compounds. 相似文献
16.
Volker Karbach Richard Knochenmuss Renato Zenobi 《Journal of the American Society for Mass Spectrometry》1998,9(11):1226-1228
We describe an improved sample preparation method for pulsed filament desorption–ionization mass spectrometry. Samples were deposited in the presence of an excess of liquid or solid matrices. Especially with liquid matrices such as glycerol, this allowed stable and reproducible ion production for a variety of compounds, including biomolecules and synthetic polymers. Substances with molecular weights up to 3000 Da could be desorbed, ionized, and detected by time-of-flight mass spectrometry. 相似文献
17.
Talat Yalcin Yuqin Dai Liang Li 《Journal of the American Society for Mass Spectrometry》1998,9(12):1303-1310
The success of matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry for the characterization of polymer structures and for the determination of average molecular weights and distributions depends on the use of a proper sample/matrix preparation protocol. This work examines the effect of solvents, particularly solvent mixtures, used to prepare polymer, matrix, and cationization reagent solutions, on MALDI analysis. It is shown that the use of solvent mixtures consisting of polymer solvents does not have a significant effect on the molecular weight determination of polystyrene 7000 and poly(methyl methacrylate) 3750. However, solvent mixtures containing a polymer nonsolvent can affect the signal reproducibility and cause errors in average weight measurement. This solvent effect was further investigated by using confocal laser fluorescence microscopy in conjunction with the use of a fluorescein-labeled polystyrene. It is demonstrated that sample morphology and polymer distribution on the probe can be greatly influenced by the type of solvents used. For sample preparation in MALDI analysis of polymers, it is important to select a solvent system that will allow matrix crystallization to take place prior to polymer precipitation. The use of an excess amount of any polymer nonsolvent should be avoided. 相似文献
18.
Matrix-assisted laser desorption ionization (MALDI) time of flight mass spectrometry was used to identify shrimp at the species level using commercial mass spectral fingerprint matching software (Bruker Biotyper). In the first step, a mass spectrum reference database was constructed from the analysis of six commercially important shrimp species: Litopenaeus setiferus, Farfantepenaeus aztecus, Sicyonia brevirostris, Pleoticus robustus, Pandalopsis dispar and Pandalus platyceros. This step required a desalting procedure for optimum performance. In the second step, the reference database was tested using 74 unknown shrimp samples from these six species. Correct identification was achieved for 72 of 74 samples (97%): 72 samples were identified at the species level and 2 samples were identified at the genus level using the manufacturer's log score specifications. The MALDI fingerprinting method for the identification of shrimp species was found to be reproducible and accurate with rapid analysis. 相似文献
19.
A method was developed for collection and analysis of bioaerosols by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry using a modified Andersen N6 bioaerosol collector. The overall goal of the study was to develop methods for obtaining mass spectra with minimal reagents and treatment steps for potential use in remote collection and analysis systems. Test bioaerosol particles were generated from a nebulized E. coli bacterial suspension and collected on MALDI targets placed in an Andersen N6 single-stage aerosol impactor. The bioaerosols were mixed with matrix either by deposition on a bare target with the matrix solution added later, or by deposition on a target pre-coated with matrix. The matrix compounds alpha-cyano-4-hydroxycinnamic acid (CHCA) and sinapic acid (SA) were tested and the SA matrix was found to give the best results in number of peaks, resolution, and signal-to-noise ratio. Deposition of bioaerosol particles onto the matrix pre-coated target did not produce signal in the m/z region above 1000, but the signal could be recovered with the addition of a 1:1 (v/v) acetonitrile/water solvent. Addition of solvent by pipette to the pre-coated targets after particle deposition recovered signal comparable to the dried-droplet sample preparations, whereas solvent sprayed into the impactor recovered fewer peaks. Deposition on pre-coated targets with post-collection solvent addition was superior to deposition on bare target followed by post-collection addition of matrix solution. 相似文献
20.
In this work, we wanted to devise a reliable method to characterize polymerized forms of tannins, their structural information and mass distribution. Size-exclusion chromatography (SEC) is a chromatographic technique used to determine molecular mass (weight) distributions of polymers. One important step in the data treatment is the modeling of the calibration curves. Polystyrenes (PS) are standards usually used because no commercial procyanidin (PC) standards are available. An off-line coupling of SEC and MALDI was carried out to measure differences between polystyrenes and procyanidins. Thus, a new calibration curve was established; from 1000 to 8000 Da, there is a good correlation between the MALDI and PS calibration curves, in this field the PS calibration is correct and enables true mass determination. For masses above 8000 Da, PS calibration overestimates the real molecular weight of PC, overestimation of 53%. And for masses below 1000 Da, PS calibration underestimates their real molecular weight (10-15%). This means that to truly characterize PC, calibration based on PC standards is required. 相似文献