首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The International Atomic Energy Agency maintains a database of internationally available certified reference materials (CRM) of natural matrices. This database is periodically updated, and presently documents nearly 25,000 measurands in 1700 materials. The organic constituents are classified in five major groups of analytes – aliphatic and aromatic hydrocarbons (A), chlorinated hydrocarbons (B), pesticides (C), organometallic compounds (D) and other organic constituents (nutrients, etc.) (E). The matrices include natural materials such as body fluids, food products, soils, and sediments, terrestrial (e.g. plants), and anthropogenic products (e.g. dust, fly ash). These five organic groups of analytes encompass more than 2000 measurands for 420 different analytes in 230 materials. Of these measurands, 1682 (68%) are certified, and 768 (32%) are provided as informational values. Within each major group of analytes, measurands reported as informational values accounted for: A (35%); B (35%); C (26%); D (10%), and E (22%). The high proportion of informational values (i.e. non-certified values) for A, B, and C, compares well with a similar but undesirable situation faced in the nineteen-seventies in the inorganic area when simultaneous multielement techniques became available. In the case of D and E, it appears that mostly targeted analytes are measured, leading to a cohesive certification profile. Although the IAEA database is not equally comprehensive for all groups of analytes cited above, it can still serve as an useful indicator of the status of organic constituents in RMs.  相似文献   

2.
The International Atomic Energy Agency (IAEA), in co-operation with the United Nations Environment Programme (UNEP), has recently prepared a survey on internationally available analytical reference materials for trace elements, nuclides and organic contaminants in biological, environmental and related matrices. The purpose is to help analysts to select reference materials for quality assurance that match as closely as possible, with respect to matrix type and concentrations of the measurands of interest, the “real” samples that are to be measured. The present version of the survey, which is available in the form of two cost-free printed volumes [1], contains over 10,000 certified and information values in 650 reference materials from 27 different producers. The 455 measurands listed include trace elements, major and minor elements, organic contaminants, organometallic compounds, radionuclides and stable isotopes. Currently, the database from which the survey has been produced is being modified and extended so as to make the data available in electronic form via the Internet. Received: 11 June 1997 / Revised: 7 July 1997 / Accepted: 9 July 1997  相似文献   

3.
Recovery, precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes, using typical sampling and gas chromatography/mass spectrometry analysis methods. These determinations were based on initial method proficiency tests and on-going internal quality control procedures. Recoveries generally ranged from 75% to 85% for all target analytes and collocated sample precision estimates were generally better than 20% for polycyclic aromatic hydrocarbons and better than 25% for hopanes. Results indicated substantial differences in data quality between the polycyclic aromatic hydrocarbons and hopanes. Polycyclic aromatic hydrocarbons demonstrated better collocated precision, lower method detection limits, lower blank levels, and better agreement with certified reference materials than the hopanes. The most serious area of concern was the disagreement between measured and expected values in the standard reference material for hopanes. With this exception, good data quality was demonstrated for all target analytes on all other data quality indicators.  相似文献   

4.
The International Atomic Energy Agency (IAEA) maintains a database of biological and environmental reference materials of natural origin (human and animal tissues, foods, plants, soils, sediments, etc.) for trace elements, radionuclides, stable isotopes, organic contaminants and other related measurands. The purpose is to help analysts to select reference materials for quality assurance purposes that match as closely as possible (i.e., with respect to matrix type and concentrations of the measurands of interest) the real samples that are to be analyzed. Former versions of this database were prepared in co-operation with the United Nations Environment Programme (UNEP), and provided as hardcopies free of charge. The latest version was from 1995. More recently the database has been updated by the IAEA so that it now contains more than 22,500 values (mass fraction or concentration) for 660 different measurands and 1,705 reference materials developed by 56 producers from 22 countries. This paper gives an overview of the structure and content of the database and of the two ways it may be browsed. Emphasis is given to reference materials that are intended to verifying analysis for radioanalytical measurements. The database is soon accessible on-line, cost-free, via the internet.  相似文献   

5.
A proficiency testing (PT) scheme was developed for a limited number of analytical laboratories participating in the analysis of natural water in Israel. Three fit-for-intended-use reference materials (RMs) were prepared for a pilot PT from natural water: RM-blank and two in-house reference materials (IHRMs) with seven analytes fortified to achieve different levels of analyte concentrations. The measurands for the PT participants were the traceable spike values certified in the IHRMs, i.e., added mass concentrations of the analytes. The RM-blank and IHRMs were found to be homogeneous and stable over 11 days, the time necessary for the experimental part of the PT. The RMs were distributed to the PT participants as unknown test items similar to routine samples. The test results were evaluated using their deviations from the IHRM-certified values. Eight Israeli laboratories took part in the interlaboratory comparison. Individual laboratory performance and metrological compatibility of the PT results of the participants, as a local group of laboratories, were evaluated for every analyte.  相似文献   

6.
Thirty Polish laboratories participated in proficiency tests (PT) for determination of persistent organic pollutants – POPs (PCBs – polychlorinated biphenyls, PAHs – polyaromatic hydrocarbons and pesticides) in solid environmental matrices (sediments, soil). Participants used their in-house method. The aim of the exercises was to obtain information about the “state of the art” of POPs analysis in environmental samples. The CV (coefficient of variation) of analytical results submitted varied from 45 to 65%, with an outlier rate 2 to 7%. The averages of results for all analytes were in good agreement with reference values. Statistical treatment of results was made. Comparison of the each result with the certified values characterizing the material has been done. Additionally, z-scores were calculated taking into account the uncertainty of a certified value and the acceptable deviation from the certified value in the range of −20% to +10% (in accordance with recommendations in the newest directives of European Union (EU) [1]); For rejecting outliers Hampel test has been applied.  相似文献   

7.
Polybrominated diphenyl ethers (PBDEs) have been measured for the first time in three different indoor dust Standard Reference Materials (SRMs) prepared by the National Institute of Standards and Technology (NIST). Two of these, SRM 2583 (Trace Elements in Indoor Dust) and SRM 2584 (Trace Elements in Indoor Dust), have been certified previously for lead and other inorganic constituents. A third, SRM 2585 (Organics in Indoor Dust), is a new indoor dust reference material prepared by NIST which will be certified for various organic compounds (polycyclic aromatic hydrocarbons, pesticides and polychlorinated biphenyls) in 2005 including certified concentrations for 16 individual PBDE congeners and reference values for an additional three PBDE congeners. Dust SRMs were analyzed for 30 PBDE congeners using high-resolution gas chromatography combined with low-resolution mass spectrometry operated in both negative chemical ionization (GC/ECNI–MS) and electron impact ionization (GC/EI–MS) modes. Sensitivity was an order of magnitude higher using GC/ECNI–MS relative to GC/EI–MS. These SRMs have been characterized and compared to the three PBDE commercial products (pentaBDE, octaBDE and decaBDE). PentaBDE and DecaBDE were present in all three SRMs and were the dominant commercial products, making up approximately 33% and 58%, respectively. Recent studies suggest that house dust may be a leading source of human exposure to PBDEs. These SRMs are the first reference materials with certified concentrations for PBDEs, which will aid in validating future measurements of PBDEs in house dust and other similar matrices. Electronic Supplementary Material Supplementary material is available for this article at http://dx.doi.org/ 10.1007/s00216-005-0227-y  相似文献   

8.
A suite of natural matrix reference materials (RMs) were used to assess the quality of analytical results obtained by k 0-instrumental neutron activation analysis (k 0-INAA) at the Joef Stefan Institute (IJS). Five certified reference materials (CRMs) from the Institute for Reference Materials and Measurements (IRMM), two standard reference materials (SRMs) from the National Institute of Standards and Technology (NIST), three RMs from the International Atomic Energy Agency (IAEA) and one RM from IJS were analyzed. Altogether, results for twenty-four elements in inorganic matrices and twenty-nine elements in organic matrices, obtained by k 0-INAA, were compared to certified values. Results obtained show good agreement with certified or assigned values except for Fe, La, Nd, Sm and U in inorganic matrices, and Ag, Al and Cr in organic matrices.  相似文献   

9.
For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs). Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

10.
A new method for the extraction-individual separation-determination of polycyclic aromatic hydrocarbons (PAHs) in soil is reported. The method is based on the integration of three steps: continuous subcritical extraction, solid-phase clean-up/preconcentration, and HPLC separation with post-column fluorimetric determination. Sodium dodecyl sulfate (SDS) was added to the water for favouring the extractability of the low-polarity analytes. Soil samples spiked with the target PAHs were subjected to static-dynamic extraction with SDS-water at 50 bar, 150 degrees C, for 15 min of static extraction and 10 min dynamic extraction at a flow-rate of 3 ml/min. Recoveries from 73.6 to 110.4% were obtained in the presence of SDS versus 30 to 80% obtained with water as extractant. The calibration graphs provided by HPLC-fluorimetric detection were run between 0.031 and 0.375 microg/ml for each analyte with regression coefficients between 0.917 and 0.999 and precision, expressed as RSD, between 1.2 and 11.5%. The method was applied to a certified reference material [CRM 524, BCR (Community Bureau of Reference), industrial soil/organic] for validation and the results obtained were in agreement with the certified values.  相似文献   

11.
The application of differential scanning calorimetry (DSC) for purity determination is well documented in literature and is used amongst others in the analysis of pure organic crystalline compounds. The aim of this work is to examine whether the DSC method for purity determination consistently produces values for the purity of polycyclic aromatic hydrocarbons (PAHs) which are sufficiently accurate as required for the certification of reference materials. For this purpose, 34 different existing PAH certified reference materials were tested. The DSC results are shown to be consistent with the results obtained by other methods assessing the organic impurities content in PAHs, like gas chromatography (GC), high performance liquid chromatography (HPLC) and mass spectrometry. Significant differences between the measured values and the certified purity values were observed only in a limited number of cases.  相似文献   

12.
A new method was developed for the simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), phthalate esters (PEs), nonylphenols (NPs) and nonylphenol mono- and diethoxylates (NP1EOs and NP2EOs, respectively) in sediment samples by means of a closed microwave system. The extractions were carried out at 21 psi and 80% of microwave power and 15 ml of acetone were used as the common extraction solvent. The filtered extract was further fractionated in two groups using Florisil cartridges: PAHs and PCBs were eluted with n-hexane:toluene (4:1) and the PEs, NPs and ethoxylates were eluted with ethyl acetate. All the compounds were analysed by gas chromatography-mass spectrometry (GC-MS). In case of PAHs and PCBs, the developed method was validated by comparison of the results obtained for the certified reference material NIST 1944 with the certified values. In the absence of a reference material for phthalate esters and nonylphenols, one sediment sample was extracted twice under the optimal conditions in order to check than an exhaustive extraction of the analytes occurred. This method is currently used in the study of the distribution of those organic contaminants in the estuaries of the Bay of Biscay (Spain).  相似文献   

13.
A rapid, simple and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) with an electrospray ionization (ESI) source for the simultaneous analysis of fourteen water-soluble vitamins (B1, B2, two B3 vitamers, B5, five B6 vitamers, B8, B9, B12 and C) in various food matrices, i.e. maize flour, green and golden kiwi and tomato pulp, is presented here. Analytes were separated by ion-suppression reversed-phase liquid chromatography in less than 10 min and detected in positive ion mode. Sensitivity and specificity of this method allowed two important results to be achieved: (i) limits of detection of the analytes at ng g(-1) levels (except for vitamin C); (ii) development of a rapid sample treatment that minimizes analyte exposition to light, air and heat, eliminating any step of extract concentration. Analyte recovery depended on the type of matrix. In particular, recovery of the analytes in maize flour was > or =70%, with the exception of vitamin C, pyridoxal-5'-phosphate and vitamin B9 (ca 40%); with tomato pulp, recovery was > or =64%, except for vitamin C (41%); with kiwi, recovery was > or =73%, except for nicotinamide (ca. 30%).  相似文献   

14.
The National Institute of Standards and Technology (NIST) has developed several Standard Reference Materials (SRMs) based on human serum. NIST SRM 909b, Human Serum, is a lyophilized human serum material with concentrations for seven organic and six inorganic analytes at two levels certified solely by definitive methods (DMs). This material provides the vehicle by which high precision, high accuracy measurements made with DMs at NIST can be transferred through the measurement hierarchy to other laboratories. Isotope dilution gas chromatographic-mass spectrometric (GC-IDMS) methods were applied to measure cholesterol, creatinine, glucose, urea, uric acid, triglycerides, and total glycerides. Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used for determination of lithium, magnesium, potassium, calcium, and chloride. In addition, chloride was determined by coulometry, providing a comparison between two DMs. Sodium, which lacks a stable isotope that would permit isotope dilution mass spectrometric (IDMS) measurement, was determined by gravimetry. SRM 909b includes certified values for total glycerides and triglycerides, which were not certified in the previous lot of this material (SRM 909a). Improvement in uniformity of vial fill weight in the production of SRM 909b resulted in smaller certified uncertainties over previous freeze-dried serum SRMs. Uncertainties at the 99% level of confidence for relative expanded uncertainty (%) for certification of the organic analytes on a mmol/L/g basis ranged from 0.44% for urea (level II) to 5.04% for glucose (level II). (In-house studies have shown glucose to be a relatively unstable analyte in similar lyophilized serum materials, degrading at about 1% per year.) Relative expanded uncertainties (99% C.I.) for certification of inorganic analytes on a mmol/L/g basis ranged from 0.25% for chloride (level I) to 0.49% for magnesium (level II). Received: 30 July 1997 / Revised: 24 October 1997 / Accepted: 31 October 1997  相似文献   

15.
The National Institute of Standards and Technology (NIST) has developed several Standard Reference Materials (SRMs) based on human serum. NIST SRM 909b, Human Serum, is a lyophilized human serum material with concentrations for seven organic and six inorganic analytes at two levels certified solely by definitive methods (DMs). This material provides the vehicle by which high precision, high accuracy measurements made with DMs at NIST can be transferred through the measurement hierarchy to other laboratories. Isotope dilution gas chromatographic-mass spectrometric (GC-IDMS) methods were applied to measure cholesterol, creatinine, glucose, urea, uric acid, triglycerides, and total glycerides. Thermal ionization isotope dilution mass spectrometry (TI-IDMS) was used for determination of lithium, magnesium, potassium, calcium, and chloride. In addition, chloride was determined by coulometry, providing a comparison between two DMs. Sodium, which lacks a stable isotope that would permit isotope dilution mass spectrometric (IDMS) measurement, was determined by gravimetry. SRM 909b includes certified values for total glycerides and triglycerides, which were not certified in the previous lot of this material (SRM 909a). Improvement in uniformity of vial fill weight in the production of SRM 909b resulted in smaller certified uncertainties over previous freeze-dried serum SRMs. Uncertainties at the 99% level of confidence for relative expanded uncertainty (%) for certification of the organic analytes on a mmol/L/g basis ranged from 0.44% for urea (level II) to 5.04% for glucose (level II). (In-house studies have shown glucose to be a relatively unstable analyte in similar lyophilized serum materials, degrading at about 1% per year.) Relative expanded uncertainties (99% C.I.) for certification of inorganic analytes on a mmol/L/g basis ranged from 0.25% for chloride (level I) to 0.49% for magnesium (level II).  相似文献   

16.
This article discusses the requirements for reference materials (RMs) for measuring the size of nanoparticles (NPs). Such RMs can be used for instrument calibration, statistical quality control or interlaboratory comparisons. They can come in the form of suspensions, powders or matrix-embedded materials [i.e. NPs integrated in a natural matrix (e.g., food, soil, or sludge)].At present, uncertainty about the most suitable form of material, the most relevant measurands and the most useful metrological-traceability statement inhibits the production of NP RMs. In addition, the lack of validated methods and qualified laboratories to produce NP RMs present formidable challenges.Metal, inorganic and organic NPs are available, but most of them are intended to be laboratory chemicals. With the exception of latex materials, certified RMs are not available, although some metrology institutes have started to develop such materials for colloidal gold and silica particles.  相似文献   

17.
Several improvements in sample pretreatment for the determination of organic pollutants (i.e. n-alkanes, polycyclic aromatic hydrocarbons, PAHs) in marine biota (mussels) are presented. The use of liquid nitrogen and homogenization of the samples are shown to be an alternative to the time consuming liophilization step required for the analysis of biota samples. Microwave-assisted hydrolysis and extraction are combined to isolate organic pollutants (19 n-alkanes and 27 PAHs) from biota matrices. Experimental design (ED) and artificial neural networks (ANNs) were used to optimize the experimental conditions. NIST-CRM 2978 was used to test the validity of the developed method which shows a good agreement with certified values.  相似文献   

18.
The objective of this study was to compare different z-score calculation for the results from proficiency testing programmes. The comparison was carried out on the data from proficiency tests for four different matrices and for all analytes included in the proficiency testing programmes organised by UKZUZ institute from the year 2005 to 2007. It represented 99 samples (three periods per year and eleven samples distributed in each period); the number of determined analytes was 108 in each period. The total number of investigated data sets was 953. Three different approaches to z-score calculation were compared. The results gave reasonably comparable evaluation in most cases but sometimes UKZUZ method proved to be rather strict. The procedure using the robust average and robust standard deviation calculated according to Algorithm A described in ISO 13528 was found to be the most suitable for matrices and level of measurands in UKZUZ proficiency tests.  相似文献   

19.
The presence of toxic organic micropollutants in municipal sewage sludges is a major problem on account of risks associated with the agricultural use of the sludges and therefore maximum tolerance limits are imposed. The aim of our study was to develop a reliable and fast analytical procedure for the determination of polycyclic aromatic hydrocarbons in sewage sludges, using focused microwave-assisted extraction. Optimization of the extraction conditions was performed on real matrices. The results of a 2(3) factorial design showed that extraction time was the only influential factor. The selected conditions (30 W, 10 min, 30 ml solvent) were used for real sludges and a certified marine sediment, leading to recoveries of between 56 and 75%. Results of an interlaboratory test confirmed these values. Finally, the technique was compared to traditional techniques (Soxhlet, sonication), and the more recent pressurized liquid extraction technique. Focused microwave-assisted extraction remains an attractive alternative technique due to its rapidity, the low solvent volume required and its moderate investment cost.  相似文献   

20.
A suite of three ginkgo-containing dietary supplement Standard Reference Materials (SRMs) has been issued by the National Institute of Standards and Technology (NIST) with certified values for flavonoid aglycones, ginkgolides, bilobalide, and selected toxic trace elements. The materials represent a range of matrices (i.e., plant, extract, and finished product) that provide different analytical challenges. The constituents have been determined by at least two independent analytical methods with measurements performed by NIST and at least one collaborating laboratory. The methods utilized different extractions, chromatographic separations, modes of detection, and approaches to quantitation. The SRMs are primarily intended for method validation and for use as control materials to support the analysis of dietary supplements and related botanical materials. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号