首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
van Staden JF  Stefan RI 《Talanta》1999,49(5):1472-1022
An on-line automated system for the simultaneous flow injection determination of calcium and fluoride in natural and borehole water with conventional calcium-selective and fluoride-selective membrane electrodes as sensors in series is described. Samples (30 μl) are injected into a TISAB II (pH=5.50) carrier solution as an ionic strength adjustment buffer. The sample-buffer zone formed is first channeled to a fluoride-selective membrane electrode and then via the calcium-selective membrane electrode to the reference electrodes. The system is suitable for the simultaneous on-site monitoring of calcium (linear range 10−5–10−2 mol l−1 detection limit 1.94×10−6 mol l−1 recovery 99.22%, RSD<0.5%) and fluoride (linear range 10−5–10−2 mol l−1 detection limit 4.83×10−6 mol l−1 recovery 98.63%, RSD=0.3%) at a sampling rate of 60 samples h−1.  相似文献   

2.
Li S  Deng N  Zheng F  Huang Y 《Talanta》2003,60(6):1097-1104
The adsorption of W (VI) on different metal oxides (TiO2, ZrO2), different crystal form of TiO2 (rutile, anatase) with high surface areas was studied and compared under different pH. A novel method for preconcentration of W (VI) with nanometer size titanium dioxide (rutile) and determination by spectrophotometry has been developed. W (VI) was selective adsorbed on 100 mg TiO2 from 250 ml solution at pH 3.0, then eluted by 2 ml 9 mol l−1 sodium hydroxide solution. The eluent was adjusted to 5 ml pH 0 solution, added 0.5 ml 12 mol l−1 HCl, 0.3 ml 3% TiCl3, 0.3 ml 50% NH4SCN, stirred for 20 min, used for the analysis of W (VI) by measuring the absorbance at 402 nm with spectrophotometry, based on the chromogenic reaction between the W (VI) and the mixture of TiCl3 and NH4SCN. This method gave a concentration enhancement of 50 for 250 ml sample, eliminated the sizable interferences on direct determination with spectrophotometry. Detection limits (3σ, n=11) of 1.2 ng ml−1, relative standard deviation of 2.3% at 10 ng ml−1 level were obtained. The method was applied to determine the W (VI) in hot spring water, river water, tap water and stream sediment. Analytical recoveries of W (VI) added to samples were 98–101%.  相似文献   

3.
The kinetics of dissolution of octacalcium phosphate (OCP) has been investigated under conditions of constant relative undersaturation with respect to OCP, σOCP=−0.57, at pH 4.500, and ionic strength (I), 0.15 mol l−1. The molar calcium/phosphate ratio (R) in the solutions was varied from 0.1 to 10. The dissolution rate decreased by 160% as R increased from 0.1 to 10. The ζ-potential of the OCP surfaces was measured in solutions equilibrated with respect to OCP at pH values ranging from 5.0 to 11. Under stoichiometric conditions (R=1.33), OCP was positively charged at pH values from 5.0 to 10. As the solution calcium concentration was increased, ζ became more positive over the entire pH range studied. At R=0.1, two isoelectric points were apparent at pH values of about 6.3 and pH 9.5. This behavior may be related to the solubility product (Ksp) of OCP. The relationship between surface characteristics and dissolution rate are discussed in terms of kink density and the kinetic ionic ratio model developed previously (J. Zhang, G.H. Nancollas, J. Colloid Interf. Sci., 200 (1998) 131.  相似文献   

4.
The cathodic adsorptive electrochemical behavior of guanine in the presence of some metal ions at the static mercury drop electrode was investigated. A 1.0×10−3 mol l−1 NaOH or a 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 solutions were used as supporting electrolytes. The reduction peak potential for guanine was found to be around −0.15 V, which is very close to the mercury reduction wave. A new peak appears at −0.60 V in the presence of copper or at −1.05 V in the presence of zinc. A square wave voltammetric procedure for electroanalytical determination of guanine in 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 containing 1.6×10−5 mol l−1of copper ions, was developed. An accumulation potential of −0.15 V during 270 s for the prior adsorption of guanine at the electrode surface was used. The response of the system was found to be linear in the range of guanine concentration from 6.62×10−8 to 1.32×10−7 mol l−1 and the detection limit was 7.0×10−9 mol l−1. The influence of DNA bases such as adenine, cytosine and thymine was also examined. Cyclic voltammetry was used to characterize the interfacial and redox mechanism.  相似文献   

5.
The photocatalytic bleaching of p-nitrosodimethylaniline (P) has been investigated in aqueous suspensions of TiO2. It was found that both charge carriers (hole and electron) were reactive to P to result in a bleaching. The roles of O2 and several hole scavengers (HCOO, EDTA, I) have also been examined. A reaction mechanism has been proposed with consideration of several primary processes photoinduced on TiO2 surface. The results of the kinetic analysis fit fairly well to those of the experiments. The rate constant (khp) of the reaction between P and the adsorbed hydroxyl radical was estimated to be in the order 1010 M−1 s−1, which is in good agreement with that obtained from the homogeneous reaction of P with free OH radicals. Of particular interest is the pH dependence of the photobleaching rate. Around both pKa of P and pHZPC of TiO2, the photobleaching of P was steeply enhanced. This can be reasonably attributed to the mutual interaction (repulsion versus attraction) between P and TiO2 particles in different pH ranges.  相似文献   

6.
Lucy CA  Tsang JS 《Talanta》2000,50(6):1283-1289
Flow injection titration was used for the determination of anionic, cationic, nonionic and zwitterionic surfactants. The procedure was based on the micellar-enhanced fluorescence of 1,8-anilino-naphthalene sulfonate (ANS). Samples were injected into a carrier stream of phosphate buffer and 1.0 mol l−1 NaCl. The sample then passed through a mixing chamber which generated the exponential peak shape needed for the titration as well as diluted the sample in the carrier stream to control the pH and ionic strength of the sample. The peak width was linearly related to the logarithm of the surfactant concentration. The minimum detectable concentration was governed by the critical micelle concentration for anionic, zwitterionic and nonionic surfactants, but below the critical micelle concentration for cationic surfactants. The linear range extended for 1.5 orders of magnitude. Reproducibility ranged from 12% at the lower end of the calibration range to 1.1% at higher concentrations. For SDS recoveries of 82–108% were achieved in matrices as concentrated as 1 mol l−1 in NaCl or Na2SO4.  相似文献   

7.
Voltammetric determination of synthetically prepared phytochelatins (γ-Glu-Cys)2Gly (PC2) and (γ-Glu-Cys)3Gly (PC3) has been studied using new type of copper solid amalgam electrode. The determination, based on the formation of cuprous complexes in buffer pH 8.1, is suitable for concentrations of PC in the range 10–100 nmol l−1. Reproducibility, employing electrochemical cleaning of the electrode surface, was statistically evaluated. The achieved limit of detection (2.1–2.6×10−9 mol l−1 for DCV measurement) together with the robust character of the electrode offer its use for detection of PCs in separated extracts of real samples.  相似文献   

8.
Amperometic flow measurements were made at +0.55 V (vs. Ag/AgCl) in 0.1 mol l−1 KOH electrolyte with an Ni(II) chemically modified electrode (CME) with an Eastman-AQ polymer film. The use and characteristics of a Ni(II)-containing crystalline and polymer-modified electrode obtained by a double coating step as a detector for amino acids in a flow-injection system using reversed-phase liquid chromatography are described. The detection of these analytes is based on the higher oxidation state of nickel (NiOOH) controlled by the applied potential. The electroanalytical parameters and the detection current for a series of amines and amino acids were investigated. The use of such a CME in the flow-injection technique was found to be suitable in a solution at low pH. The linear range for glycine is 5 × 10−6-0.1 mol l−1 with a detection limit of 1.0×10−6 mol l−1. A 1 × 10−4 mol l−1 mixture of serine and tyrosine was also detected after separation on an Nucleosil C18 column.  相似文献   

9.
针对TiO_2半导体不能有效吸收可见光,光电转换效率较低等问题,可通过对TiO_2半导体进行修饰和改性,制备TiO_2复合材料,提高其光电化学性能。因此,本工作以Ti表面制备的TiO_2纳米管膜为基础,分别应用循环伏安电沉积法和脉冲电沉积法在膜表面先后沉积MoO3和ZnSe颗粒,获得具有级联能带结构的ZnSe/MoO3/TiO_2纳米管复合膜,并将其应用于对403不锈钢(403SS)实施光生阴极保护。相较于纯TiO_2纳米管膜,紫外-可见(UV-Vis)吸收光谱和光致发光(PL)谱测试表明,ZnSe/MoO3/TiO_2复合膜的吸收边红移,在可见光区具有良好的光吸收性能,光生载流子复合得到更有效抑制。光电化学测试表明,白光照射下,处于0.5 mol·L~(-1) KOH溶液中的ZnSe/MoO3/TiO_2复合膜的光电流密度达到了同条件下纯TiO_2膜的2倍,可使与之耦连的浸泡于0.5 mol·L-1 NaCl溶液中的403SS电极电位下降470 mV,显示出良好的光生阴极保护效应。复合膜还具有一定的储能特性,在光照后又转为暗态的22.5 h内仍对403SS具有一定阴极保护作用。  相似文献   

10.
Xu J  Wang Y  Xian Y  Jin L  Tanaka K 《Talanta》2003,60(6):1123-1130
A multiwall carbon nanotubes (MWNTs) film modified electrode was prepared and used as an amperometric sensor for the simultaneous determination of oxidizable amino acids including cysteine, tryptophane and tyrosine. The electrochemical behaviors of these amino acids at this modified electrode were studied by cyclic voltammetry (CV). The results indicated that the MWNTs chemically modified electrode (CME) exhibited efficient electrocatalytic activity towards the oxidation of these amino acids with relatively high sensitivity, stability and long-life. Following separation by ion chromatography (IC) with 2.0×10−3 mol l−1 citric acid buffer solution (pH 6.5) as eluent, cysteine, tryptophane and tyrosine could be determined by the MWNTs CME successfully. Under the optimal conditions, the detection limits were 7.0×10−7 mol l−1 for cysteine, 2.0×10−7 mol l−1 for tryptophane and 3.5×10−7 mol l−1 for tyrosine at the signal-to-noise of 3, respectively. The method was applied successfully to the determination of these substances in plasma.  相似文献   

11.
A highly sensitive and selective method is described for the determination of trace amounts of nitrite based on its effect on the oxidation of carminic acid with bromate. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of carminic acid at 490 nm after 3 min of mixing the reagents. The optimum reaction conditions were 1.8×10−1 mol l−1 H2SO4, 3.8×10−3 mol l−1 KBrO3, and 1.2×10−4 mol l−1 carminic acid at 30°C. By using the recommended procedure, the calibration graph was linear from 0.2 to 14 ng ml−1 of nitrite; the detection limit was 0.04 ng ml−1; the R.S.D. for six replicate determinations of 6 ng ml−1 was 1.7%. The method is mostly free from interference, especially from large amounts of nitrate and ammonium ions. The proposed method was applied to the determination of nitrite in rain and river water.  相似文献   

12.
In situ attenuated total reflectance infrared (ATR-IR) spectroscopy has been applied to the study of the influence of phosphate on the extent of protein adsorption onto TiO2. Immunoglobulin G (Ig.G) was adsorbed onto a TiO2 sol–gel film from solutions containing phosphate or NaCl. Monitoring of the amide II absorbance (v=1545 cm−1) confirmed reduced protein adsorption from the phosphate containing solution. In situ ATR-IR spectroscopy was also used to study phosphate induced desorption of Ig.G. Solutions containing various phosphate concentrations were passed over a TiO2 film with Ig.G adsorbed to it. As the concentration of phosphate increased the amide II absorbance decreased confirming the removal of bound Ig.G from the TiO2 surface. As the amide II absorbance decreased the phosphate absorbance (v=1080 cm−1) increased suggesting accumulation of phosphate at the TiO2 surface. Not all of the bound protein could be displaced from the TiO2 surface by phosphate suggesting the presence of weakly and strongly bound Ig.G.  相似文献   

13.
Liao W  Shang Q  Yu G  Li D 《Talanta》2002,57(6):6184-1092
Phase behavior of the extraction system, Cyanex 923–heptane/H2SO4–H2O has been studied. The third phase appeared at different aqueous H2SO4 concentration with varying initial Cyanex 923 concentration and temperature affects its appearance. Almost all of H2SO4 and H2O are extracted into the middle phase. The H2SO4 concentration in the third phase increases with the increasing aqueous acid concentration (CH2SO4,b) while the water content first increases and then reaches a constant value at CH2SO4,b=11.3 mol l−1. In the region of CH2SO4,b higher than 5.2 mol l−1, the composition of the middle phase is only related to the equilibrium concentration of H2SO4 in the bottom phase. H2SO4 and H2O are transferred into the middle phase mainly by their coordination with Cyanex 923 when CH2SO4,b is less than 11.3 mol l−1. When CH2SO4,b is higher than 11.3 mol l−1, excess H2SO4 is solubilized into the polar layer of the aggregates. In the region considered, the extracted complex changes from C923 · H2SO4 to C923 · H2SO4 · H2O and then to C923 · (H2SO4)2 · H2O.  相似文献   

14.
The paper reports results of a study on the specific adsorption of F, Cl, Br, I, ClO3, BrO3, IO3 and IO4 on hydrous γ-Al2O3. The isotherms of the anion adsorption and the adsorption dependencies on pH and the ionic strength of the solution have been determined under the equilibrium conditions. According to the degree of affinity to γ-Al2O3, the anions can be ordered as: I3334−. It has been established that the sorption of IO4 and F involves the formation of surface complexes in the inner co-ordination sphere, whereas that of Cl, Br, I, ClO3, BrO3 and IO3 takes place through formation of ion pair complexes in the outer co-ordination sphere. In the dynamic system, the exchange isoplanes and elution curves have been determined for selected anions on columns filled with Al2O3. It has been shown that γ-Al2O3 can be used for isolation and concentration of IO3 from natural waters in order to decrease the limit of the ions determination to 2 μg l−1. Using differential pulse voltammetry (DPV), after isolation and concentration on γ-Al2O3, the content of iodates has been determined in mineral, marine and tap water doped with these ions.  相似文献   

15.
Liu JF  Liang X  Jiang GB  Cai YQ  Zhou QX  Liu GG 《Talanta》2003,60(6):1155-1161
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid–liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 μl of 1 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 μg l−1 (S/N=3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples.  相似文献   

16.
A THGA graphite furnace with Zeeman background correction has been used to determine platinum content in copper ore and copper concentrate at the part per billion (ppb) concentration level. Two different procedures for the separation of trace platinum have been applied: (i) use of an ion exchange resin; and (ii) a two-stage method based on platinum separation on inorganic carriers. The influence of interfering elements in the matrix (Cu, Pb, Fe, Ti, V, Au, Pd, Ir, Rh and Al) has been examined using a graphite furnace. It was found that the presence of Cu (12.5–100 mg l−1), Pb (100–500 mg l−1), Fe (100–2000 mg l−1), Ti (25–100 mg l−1), V (25–100 mg l−1), Au (25–300 mg l−1), Pd (20–250 mg l−1), Ir (0.5–3.5 mg l−1) and Rh (0.025–1 mg l−1) in the samples analyzed has no effect on the platinum absorption signal when using a recommended temperature program (Tpyr=1300°C, Tat=2450°C). Spectral interference was observed, which was due to aluminum, as a result of the close neighborhood of the Pt 265.945-nm and Al 266.039-nm lines. This interference could not be eliminated by the Zeeman background correction.  相似文献   

17.
The repetitive discoloration kinetics of the azo-dye Methyl Orange (taken as a model organic compound) was followed under solar simulated radiation (90 mW/cm2) to assess the performance of the TiO2/Tedlar® composite photocatalyst. The influence of solution parameters on the photo-discoloration process: pH, dye concentration, applied light intensity and concentration of H2O2 were systematically investigated. During the photocatalysis a modification occurs in the TiO2/Tedlar® composite due to the TiO2 interaction with the Tedlar® film. Physical insight is given for the stabilization mechanism of the TiO2 particles in the Tedlar matrix based on the data obtained by X-ray photoelectron spectroscopy (XPS). The F 1s peak of the Tedlar film indicates that the TiO2 is loaded on the Tedlar fluoro-groups. The loading of TiO2 on the 75 μm thick Tedlar® film was 0.9% (w/w) as determined by atomic absorption spectrophotometry (AAS). Attenuated total reflection infrared spectroscopy (ATRIR) shows no formation of additional bands within the photodiscoloration reaction. This shows that an efficient catalysis taking place on the TiO2/Tedlar® surface. The rugosity (mean square roughness, rms) of the TiO2/Tedlar® film was determined by atomic force microscopy (AFM) to be 19.7 nm. This value remained constant during long-term operation. Transmission electron microscopy (TEM) reports the thickness and coverage of TiO2 Degussa P-25 on the Tedlar® surface before and after photocatalysis.  相似文献   

18.
Matoso E  Kubota LT  Cadore S 《Talanta》2003,60(6):1105-1111
An analytical method using silica gel chemically modified with zirconium (IV) phosphate for preconcentration of lead and copper, in a column system, and their sequential determination by flame atomic absorption spectrometry (FAAS), was developed. Sample solutions are passed through a glass column packed with 100 mg of the sorbent material, at pH 4.5, and lead and copper are eluted with 1.0 mol l−1 HNO3 at a flow rate of 2.0 ml min−1. The extraction of copper is affected by Fe(II), Mn(II), Zn(II), Ni(II) and Co(II) while only Fe(II) interferes in the lead determination. These interferences may be overcome with an appropriate addition of a KI or NaF solution. An enrichment factor of 30 was obtained for both metals. While the limits of detection (3σ) were 6.1 and 1.1 μg l−1, for Pb and Cu, respectively, the limits of determination were 16.7 and 3.3 μg l−1. The precision expressed as relative standard deviation (R.S.D.) obtained for 3.3 μg l−1 of Cu and 16.7 μg l−1 of Pb were 4.3 and 4.7%, respectively, calculated from ten measurements. The proposed method was evaluated with reference material and was applied for the determination of lead and copper in industrial and river waters.  相似文献   

19.
In this paper, photoelectro-synergistic catalysis oxidation of organics in the water on Ti/TiO2/PbO2 electrode was investigated. The prepared TiO2 film was investigated with Atomic force micrograph (AFM). Furthermore, the results were compared with those obtained from electrocatalysis (EC) and electro-assisted photocatalysis (PC). The method proposed employed photoelectro-synergistic catalysis (PEC), together with flow injection analysis, to determine the chemical oxygen demand (COD) values. It was shown that the method of photoelectro-synergistic catalysis had lower detection limit (15.0 mg l−1) and wider linear range (30.0–2500.0 mg l−1) than the methods of electro-assisted photocatalysis and electrocatalysis. The results obtained by the proposed method and conventional one were compared by carrying out the experiment on 20 wastewater samples and also agreed well by high correlation (R = 0.9912).  相似文献   

20.
The objective of this study was to investigate the retention of phosphate anions, H2PO4 and HPO42−, by nanofiltration. The first part of this study deals with the characterisation of the NF200 membrane used in permeation experiments with aqueous solutions of neutral organic and charged inorganic solutes. In the second part the effects of feed pressure, ionic strength, concentration and pH on the retention of phosphate anions were investigated. Results show that the membrane is negatively charged, its pore radius is around 0.5 nm and the retention order for the salts tested was R(Na2SO4) > R(NaCl) > R(CaCl2). The retentions of phosphate anions are in the order of 85% for H2PO4 and 96% for HPO42−. They are relatively high when compared to retentions of other anions with the same charge. The retentions of phosphate anions, particularly the monovalent species, depend on the chemical parameters (feed concentration, ionic strength, and pH) and applied pressure. The experimental data were analysed using the Speigler–Kedem model and the transport parameters, i.e., the reflection coefficient (σ) and solute permeability (Ps) have been determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号