首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
Psychometric functions (PFs) for forward-masked tones were obtained for conditions in which signal level was varied to estimate threshold at several masker levels (variable-signal condition), and in which masker level was varied to estimate threshold at several signal levels (variable-masker condition). The changes in PF slope across combinations of masker frequency, masker level, and signal delay were explored in three experiments. In experiment 1, a 2-kHz, 10-ms tone was masked by a 50, 70 or 90 dB SPL, 20-ms on-frequency forward masker, with signal delays of 2, 20, or 40 ms, in a variable-signal condition. PF slopes decreased in conditions where signal threshold was high. In experiments 2 and 3, the signal was a 4-kHz, 10-ms tone, and the masker was either a 4- or 2.4-kHz, 200-ms tone. In experiment 2, on-frequency maskers were presented at 30 to 90 dB SPL in 10-dB steps and off-frequency maskers were presented at 60 to 90 dB SPL in 10-dB steps, with signal delays of 0, 10, or 30 ms, in a variable-signal condition. PF slopes decreased as signal level increased, and this trend was similar for on- and off-frequency maskers. In experiment 3, variable-masker conditions with on- and off-frequency maskers and 0-ms signal delay were presented. In general, the results were consistent with the hypothesis that peripheral nonlinearity is reflected in the PF slopes. The data also indicate that masker level plays a role independent of signal level, an effect that could be accounted for by assuming greater internal noise at higher stimulus levels.  相似文献   

2.
Forward-masking growth functions for on-frequency (6-kHz) and off-frequency (3-kHz) sinusoidal maskers were measured in quiet and in a high-pass noise just above the 6-kHz probe frequency. The data show that estimates of response-growth rates obtained from those functions in quiet, which have been used to infer cochlear compression, are strongly dependent on the spread of probe excitation toward higher frequency regions. Therefore, an alternative procedure for measuring response-growth rates was proposed, one that employs a fixed low-level probe and avoids level-dependent spread of probe excitation. Fixed-probe-level temporal masking curves (TMCs) were obtained from normal-hearing listeners at a test frequency of 1 kHz, where the short 1-kHz probe was fixed in level at about 10 dB SL. The level of the preceding forward masker was adjusted to obtain masked threshold as a function of the time delay between masker and probe. The TMCs were obtained for an on-frequency masker (1 kHz) and for other maskers with frequencies both below and above the probe frequency. From these measurements, input/output response-growth curves were derived for individual ears. Response-growth slopes varied from >1.0 at low masker levels to <0.2 at mid masker levels. In three subjects, response growth increased again at high masker levels (>80 dB SPL). For the fixed-level probe, the TMC slopes changed very little in the presence of a high-pass noise masking upward spread of probe excitation. A greater effect on the TMCs was observed when a high-frequency cueing tone was used with the masking tone. In both cases, however, the net effects on the estimated rate of response growth were minimal.  相似文献   

3.
Previous studies have suggested that temporal effects in masking may be consistent with a decrease in cochlear gain. One paradigm used to show this is to measure the level of a long-duration masker required to just mask a short-duration tone that occurs near masker onset. The temporal effect is revealed when the signal is detected at a lower signal-to-noise ratio following preceding stimulation (either an extension of the masker or a separate precursor). The present study examined whether this effect depends on precursor level. The signal was a 10-ms, 4-kHz tone. The masker was 200 ms. A fixed-level precursor had the same frequency characteristics as the masker, and was 205 ms. The masker and precursor had either no notch or a wide notch about the signal frequency. For a given precursor level, the growth of masker level with signal level was determined. These data were used to estimate input-output functions. The results are consistent with a graded decrease in gain at the signal frequency when there is no notch in the masker and precursor, and a graded decrease in suppression when there is a large notch. These results could be consistent with the action of the medial olivocochlear reflex.  相似文献   

4.
Psychophysical estimates of compression often assume that the basilar-membrane response to frequencies well below characteristic frequency (CF) is linear. Two techniques for estimating compression are described here that do not depend on this assumption at low CFs. In experiment 1, growth of forward masking was measured for both on- and off-frequency pure-tone maskers for pure-tone signals at 250, 500, and 4000 Hz. The on- and off-frequency masking functions at 250 and 500 Hz were just as shallow as the on-frequency masking function at 4000 Hz. In experiment 2, the forward masker level required to mask a fixed low-level signal was measured as a function of the masker-signal interval. The slopes of these functions did not differ between signal frequencies of 250 and 4000 Hz for the on-frequency maskers. At 250 Hz, the slope for the 150-Hz masker was almost as steep as that for the on-frequency masker, whereas at 4000 Hz the slope for the 2400-Hz masker was much shallower than that for the on-frequency masker. The results suggest that there is substantial compression, of around 0.2-0.3 dB/dB, at low CFs in the human auditory system. Furthermore, the results suggest that at low CFs compression does not vary greatly with stimulation frequency relative to CF.  相似文献   

5.
"Overshoot" is a simultaneous masking phenomenon: Thresholds for short high-frequency tone bursts presented shortly after the onset of a broadband masker are raised compared to thresholds in the presence of a continuous masker. Overshoot for 2-ms bursts of a 5000-Hz test tone is described for four subjects as a function of the spectral composition and level of the masker. First, it was verified that overshoot is largely independent of masker duration. Second, overshoot was determined for a variety of 10-ms masker bursts composed of differently filtered uniform masking noise with an overall level of 60 dB SPL: unfiltered, high-pass (cutoff at 3700 Hz), low-pass (cutoff at 5700 Hz), and third-octave-band-(centered at 5000 Hz) filtered uniform masking noises presented separately or combined with different bandpass maskers (5700-16000 Hz, 5700-9500 Hz, 8400-16000 Hz) were used. Third, masked thresholds were measured for maskers composed of an upper or lower octave band adjacent to the third-octave-band masker as a function of the level of the octave band. All maskers containing components above the critical band of the test tone led to overshoot; no additional overshoot was produced by masker components below it. Typical values of overshoot were on the order of 12 dB. Overshoot saturated when masker levels were above 60 dB SPL for the upper octave-band masker. The standard neurophysiological explanation of overshoot accounts only partially for these data. Details that must be accommodated by any full explanation of overshoot are discussed.  相似文献   

6.
Shortening the duration of a Gaussian-shaped 2-kHz tone-pip causes the intensity-difference limen (DL) to depart from the "near-miss to Weber's law" and swell into a mid-level hump [Nizami et al., J. Acoust. Soc. Am. 110, 2505-2515 (2001)]. For some subjects the size of this hump approaches or exceeds the size reported for longer tones under forward masking, suggesting that forward masking might make little difference to the DL for very brief probes. To test this hypothesis, DLs were determined over 30 to 90 dB SPL for a brief Gaussian-shaped 2-kHz tone-pip. DLs were obtained first without forward masking, then with the pip placed 10 or 100 ms after a 200-ms 2-kHz tone of 50 dB SPL, or 100 ms after a 200-ms 2-kHz tone of 70 dB SPL. DLs inflated significantly under all forward-masking conditions. DLs also enlarged under an 80 dB SPL forward masker at pip delays of 4, 10, 40, and 100 ms. The peaks of the humps obtained under forward masking clustered around a sensation level (SL) that was significantly lower than the average SL for the peaks of the humps obtained without forward masking. Overall, the results do not support the neuronal-recovery-rate model of Zeng et al. [Hear. Res. 55, 223-230 (1991)], but are not incompatible with the Carlyon and Beveridge hypothesis [J. Acoust. Soc. Am. 93, 2886-2895 (1993)] that nonsimultaneous maskers corrupt the memory trace evoked by the probe.  相似文献   

7.
The effective internal level of a 1-kHz tone at 50 dB SPL was estimated by measuring the forward masking produced on a 10-ms signal tone of the same frequency. Noise containing a spectral notch was then added to the masker tone, and its influence on the effective level of the tone was measured with a variety of noise levels, notch widths, and notch shapes. In experiment 1, the masker tone was centered in the spectral notch, itself centered in a 2-kHz band of noise. As the spectrum level in the noise passbands increased from 6 dB/Hz to 36 dB/Hz, signal threshold decreased, indicating a decrease in masking by the masker tone. This "unmasking" effect of the noise was attributed to suppression of the masker tone by the components in the noise. Unmasking was greatest with the narrowest spectral notch (250 Hz), and decreased to zero as the notch widened to 1500 Hz. Compared to its level when presented alone, the effective internal level of the masker tone could be reduced by up to 30 dB (250-Hz notch, 36 dB/Hz). The relative suppressive strength of individual noise components was estimated in experiment 2, in which the 1-kHz masker tone was located at one edge of a spectral notch, rather than in the center. Noise spectrum level was fixed at 16 dB/Hz. As notch width decreased to zero, on either the high-frequency or low-frequency side of the masker tone, its effective internal level was again reduced by approximately 30 dB. In a tentative analysis, the first derivative of the smoothed threshold function was taken, to provide an estimate of the relative contributions to suppression at 1 kHz of noise components between 250 and 1740 Hz.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
The purpose of this report is to present new data that provide a novel perspective on temporal masking, different from that found in the classical auditory literature on this topic. Specifically, measurement conditions are presented that minimize rather than maximize temporal spread of masking for a gated (200-ms) narrow-band (405-Hz-wide) noise masker logarithmically centered at 2500 Hz. Masked detection thresholds were measured for brief sinusoids in a two-interval, forced-choice (21FC) task. Detection was measured at each of 43 temporal positions within the signal observation interval for the sinusoidal signal presented either preceding, during, or following the gating of the masker, which was centered temporally within each 500-ms observation interval. Results are presented for three listeners; first, for detection of a 1900-Hz signal across a range of masker component levels (0-70 dB SPL) and, second, for masked detection as a function of signal frequency (fs = 500-5000 Hz) for a fixed masker component level (40 dB SPL). For signals presented off-frequency from the masker, and at low-to-moderate masker levels, the resulting temporal masking functions are characterized by sharp temporal edges. The sharpness of the edges is accentuated by complex patterns of temporal overshoot and undershoot, corresponding with diminished and enhanced detection, respectively, at both masker onset and offset. This information about the onset and offset timing of the gated masker is faithfully represented in the temporal masking functions over the full decade range of signal frequencies (except for fs=2500 Hz presented at the center frequency of the masker). The precise representation of the timing information is remarkable considering that the temporal envelope characteristics of the gated masker are evident in the remote masking response at least two octaves below the frequencies of the masker at a cochlear place where little or no masker activity would be expected. This general enhancement of the temporal edges of the masking response is reminiscent of spectral edge enhancement by lateral suppression/inhibition.  相似文献   

9.
Temporal effects in simultaneous masking were measured as a function of masker level for an on-frequency broadband masker and an off-frequency narrow-band masker for signal frequencies of 750, 1730, and 4000 Hz. The on-frequency masker was 10 equivalent rectangular bandwidths (ERBs) wide and centered at the signal frequency; the off-frequency masker was 500 Hz wide and its lower frequency edge was 1.038 ERBs higher in frequency than the signal. The primary goal of the study was to determine whether previously observed differences regarding the effects of signal frequency and masker level on the temporal effect for these two different types of masker might be due to considerably different signal levels at threshold. Despite similar masked thresholds, the effects of signal frequency and masker level in the present study were different for the two masker types. The temporal effect was significant for the two highest frequencies and absent for the lowest frequency in the presence of the broadband masker, but was more or less independent of frequency for the narrow-band masker. The temporal effect increased but then decreased as a function of level for the broadband masker (at the two higher signal frequencies, where there was a temporal effect), but increased and reached an asymptote for the narrow-band masker. Despite the different effects of signal frequency and masker level, the temporal effects for both types of masker can be understood in terms of a basilar-membrane input-output function that becomes more linear during the course of masker stimulation.  相似文献   

10.
The effects of forward masker duration on psychophysical measures of frequency selectivity were investigated in two experiments. In both experiments, masker duration was 50 or 400 ms, signal duration was 20 ms, and there was no delay between masker offset and signal onset. In the first experiment, growth-of-masking functions were measured for a masker whose frequency was below, at, or above the 1000-Hz signal frequency. From those data, input filter patterns (IFPs) were plotted for masker levels from 40-90 dB SPL. In the second experiment, masking patterns (MPs) were measured for a 1000-Hz masker presented at 50, 70, and 90 dB SPL. Both measures of frequency selectivity (IFPs and MPs) indicate that frequency selectivity is greater for the 400-ms masker. These data suggest that there may be a sharpening of frequency selectivity with time at a stage prior to the adaptation observed in forward masking.  相似文献   

11.
Masking period patterns (MPPs) were measured in listeners with normal and impaired hearing using amplitude-modulated tonal maskers and short tonal probes. The frequency of the masker was either the same as the frequency of the probe (on-frequency masking) or was one octave below the frequency of the probe (off-frequency masking). In experiment 1, MPPs were measured for listeners with normal hearing using different masker levels. Carrier frequencies of 3 and 6 kHz were used for the masker. The probe had a frequency of 6 kHz. For all masker levels, the off-frequency MPPs exhibited deeper and longer valleys compared with the on-frequency MPPs. Hearing-impaired listeners were tested in experiment 2. For some hearing-impaired subjects, masker frequencies of 1.5 kHz and 3 kHz were paired with a probe frequency of 3 kHz. MPPs measured for listeners with hearing loss had similar shapes for on- and off-frequency maskers. It was hypothesized that the shapes of MPPs reflect nonlinear processing at the level of the basilar membrane in normal hearing and more linear processing in impaired hearing. A model assuming different cochlear gains for normal versus impaired hearing and similar parameters of the temporal integrator for both groups of listeners successfully predicted the MPPs.  相似文献   

12.
These experiments investigated whether perceptual cueing plays a role in the "unmasking" effects which have been observed in forward masking for narrow-band noise maskers and brief signals. The forward masking produced by a 100-Hz-wide noise masker at a level of 60 dB SPL was measured for a 1-kHz sinusoidal signal with a raised-cosine envelope and a duration of 10 ms at the 6-dB-down points, both for the masker alone, and with various components added to the masker (and gated synchronously with the masker). Unmasking was found to occur even for components which were extremely unlikely to produce a significant suppression of the masker: these included a 75-dB SPL 4-kHz sinusoid, a 50-dB SPL 1.4-kHz sinusoid, a noise low-pass filtered at 4 kHz with a spectrum level of 0 dB, and a noise low-pass filtered at 4 kHz with a spectrum level of 20 dB presented in the opposite ear to the masker-plus-signal. It is concluded that perceptual cueing can play a significant role in producing unmasking for brief signals following narrow-band noise maskers, and that it is unwise to interpret the unmasking solely in terms of suppression.  相似文献   

13.
The present study examined the relative influence of the off- and on-frequency spectral components of modulated and unmodulated maskers on consonant recognition. Stimuli were divided into 30 contiguous equivalent rectangular bandwidths. The temporal fine structure (TFS) in each "target" band was either left intact or replaced with tones using vocoder processing. Recognition scores for 10, 15 and 20 target bands randomly located in frequency were obtained in quiet and in the presence of all 30 masker bands, only the off-frequency masker bands, or only the on-frequency masker bands. The amount of masking produced by the on-frequency bands was generally comparable to that produced by the broadband masker. However, the difference between these two conditions was often significant, indicating an influence of the off-frequency masker bands, likely through modulation interference or spectral restoration. Although vocoder processing systematically lead to poorer consonant recognition scores, the deficit observed in noise could often be attributed to that observed in quiet. These data indicate that (i) speech recognition is affected by the off-frequency components of the background and (ii) the nature of the target TFS does not systematically affect speech recognition in noise, especially when energetic masking and/or the number of target bands is limited.  相似文献   

14.
The purpose of this investigation was to examine two stimulus parameters that were reasoned to be of importance to comodulation masking release (CMR). The first was the degree of fluctuation, or depth of modulation, in the masker bands, and the second was the temporal position of the signal with respect to the modulations of the masker. The investigation began by demonstrating the efficacy of sinusoidally amplitude-modulated (SAM) tonal complex maskers in eliciting CMR. "Nine-band" maskers, 650 ms in duration, were constructed by adding together nine SAM tones spaced at 100-Hz intervals from 300 to 1100 Hz. The rate of modulation for each SAM tone was 10 Hz, and the depth of modulation was 100%. Using such maskers, it was shown that when the on-frequency SAM tone had a modulation depth of 100%, the threshold for a 250-ms, 700-Hz tone improved monotonically as the modulation depths of the flanking SAM tones increased from 0% to 100%. When the on-frequency SAM tone had a modulation depth of 63%, some listeners performed optimally when the flanking SAM tones also exhibited a modulation depth of 63%, whereas others performed best when the flankers had modulation depths of 100%. With regard to signal position, a typical CMR effect was observed when the signal, consisting of a train of three 50-ms, 700-Hz tone bursts, was placed in the dips of the on-frequency masker. However, when the signal was placed at the peaks of the envelope, an increase in masking was observed for a comodulated masker.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
The overshoot effect can be reduced by temporary hearing loss induced by aspirin or exposure to intense sound. The present study simulated a hearing loss at 4.0 kHz via pure-tone forward masking and examined the effect of the simulation on threshold for a 10-ms, 4.0-kHz signal presented 1 ms after the onset of a 400-ms, broadband noise masker whose spectrum level was 20 dB SPL. Masker frequency was 3.6, 4.0, or 4.2 kHz, and masker level was 80 dB SPL. Subject-dependent delays were determined such that 10 or 20 dB of masking at 4.0 kHz was produced. In general, the pure-tone forward masker did not reduce the simultaneous-masked threshold, suggesting that elevating threshold with a pure-tone forward masker does not sufficiently simulate the effect of a temporary hearing loss on overshoot.  相似文献   

16.
Two experiments investigated the relative influence of components close to and remote from the signal frequency (fs) on the overshoot effect. Overshoot was defined as the difference in threshold between a signal presented 4 ms after, and that for one presented 300 ms after, the onset of a 350-ms masker. Experiment 1 measured the overshoot effect using both wideband and narrow-band maskers (centered on fs), at two signal frequencies and three masker levels. Experiment 2 used a masker consisting of a "middle band" (MB, centered on fs) and two flanking bands (FBs, which, when combined with the MB, produced a flat wideband spectrum). The masker was continuous except for a 300-ms interval just prior to the signal, during which either all three bands, the MB alone, or the FBs alone were turned off. The results of both experiments showed that the overshoot effect was usually determined by off-frequency components. However, the on-frequency components played a substantial role when signal-to-noise ratios (SNRs) at threshold were unusually high, such as at fs = 6500 Hz and intermediate masker levels. It is suggested that two different mechanisms contribute to the overshoot effect: an off-frequency mechanism which operates at all fs and masker levels, and an on-frequency mechanism which contributes to the overshoot effect only at high-threshold SNRs.  相似文献   

17.
The temporal course of masking and the auditory filter shape   总被引:1,自引:0,他引:1  
Recent experiments have shown that frequency selectivity measured in tone-on-tone simultaneous masking improves with increasing delay of a brief signal relative to the onset of a longer duration gated masker. To determine whether a similar improvement occurs for a notched-noise masker, threshold was measured for a 20-ms signal presented at the beginning, the temporal center, or the end of the 400-ms masker (simultaneous masking), or immediately following the masker (forward masking). The notch width was varied systematically and the notch was placed both symmetrically and asymmetrically about the 1-kHz signal frequency. Growth-of-masking functions were determined for each temporal condition, for a noise masker without a spectral notch. These functions were used to express the thresholds from the notched-noise experiment in terms of the level of a flat-spectrum noise which would produce the same threshold. In simultaneous masking the auditory filter shapes derived from the transformed data did not change significantly with signal delay, suggesting that the selectivity of the auditory filter does not develop over time. In forward masking the auditory filter shapes were sharper than those for simultaneous masking, particularly on the high-frequency side, which was attributed to suppression.  相似文献   

18.
Intensity-discrimination thresholds were measured for a 25-ms, 6-kHz pure tone for pedestal levels from 40 to 90 dB sound pressure level (SPL) with and without a forward masker (100-ms narrowband Gaussian noise, N(0)=70 dB). When the masker was present, the masker and probe were separated by 100 ms of silence. Unmasked and masked thresholds were measured in a two-interval monaural procedure and, separately, in a single-interval interaural procedure in which the pedestal and incremented pedestals were presented simultaneously to opposite ears. While the monaural thresholds were elevated markedly by the forward masker for mid-level pedestals, interaural thresholds were nearly unaffected by the masker across pedestal levels. The results argue against the notion that the monaural elevation in forward-masked thresholds is due to degraded encoding of intensity information at early stages of auditory processing.  相似文献   

19.
Psychophysical tuning curves (PTCs) measured in simultaneous masking usually sharpen as a short duration signal is moved from the onset to the temporal center of a longer duration masker. Filter shapes derived from notched-noise maskers have not consistently shown this effect. One possible explanation for this difference is that the signal level is fixed in the PTC paradigm, whereas the masker level is usually fixed in the notched-noise paradigm. In the present study, the signal level was fixed at 10 dB SL in both paradigms. The signal was 20 ms in duration, and presented at the onset or temporal center of the 400-ms masker. The masker was a pure tone presented in quiet (PTC) or in the presence of a pure-tone "restrictor" intended to limit off-frequency listening (PTCr), or it was a noise with a spectral notch placed symmetrically or asymmetrically about the 2-kHz signal frequency. Filter shapes were derived from the PTC, PTCr, and notched-noise data using the roex (p, w, t) model. The effects of signal delay and masking paradigm on filter bandwidth were analyzed with a two-factor repeated-measures ANOVA. There was a significant effect of signal delay (the filters sharpened with time) and masking paradigm (the filters derived from the notched-noise data were significantly wider than those derived from either of the PTC measurements, which did not differ from one another). Although the interaction between delay and paradigm was not significant, the filter derived from the notched-noise data sharpened more with time than did the other filters, and thus the bandwidth of the filters from the three paradigms were more similar at the longer delay than at the shorter delay. It is likely that the tuning-curve and notched-noise paradigms measure the same underlying filtering, but that various other factors contribute differentially to the derived filter shapes.  相似文献   

20.
Thresholds for the detection of harmonic complex tones in noise were measured as a function of masker level. The rms level of the masker ranged from 40 to 70 dB SPL in 10-dB steps. The tones had a fundamental frequency (F0) of 62.5 or 250 Hz, and components were added in either cosine or random phase. The complex tones and the noise were bandpass filtered into the same frequency region, from the tenth harmonic up to 5 kHz. In a different condition, the roles of masker and signal were reversed, keeping all other parameters the same; subjects had to detect the noise in the presence of a harmonic tone masker. In both conditions, the masker was either gated synchronously with the 700-ms signal, or it started 400 ms before and stopped 200 ms after the signal. The results showed a large asymmetry in the effectiveness of masking between the tones and noise. Even though signal and masker had the same bandwidth, the noise was a more effective masker than the complex tone. The degree of asymmetry depended on F0, component phase, and the level of the masker. The maximum difference between masked thresholds for tone and noise was about 28 dB; this occurred when the F0 was 62.5 Hz, the components were in cosine phase, and the masker level was 70 dB SPL. In most conditions, the growth-of-masking functions had slopes close to 1 (on a dB versus dB scale). However, for the cosine-phase tone masker with an F0 of 62.5 Hz, a 10-dB increase in masker level led to an increase in masked threshold of the noise of only 3.7 dB, on average. We suggest that the results for this condition are strongly affected by the active mechanism in the cochlea.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号