首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
Pyrogenic organic matter (PyOM), the incomplete combustion product of organic materials, is considered stable in soils and represents a potentially important terrestrial sink for atmospheric carbon dioxide. One well‐established method of measuring PyOM in the environment is as benzene polycarboxylic acids (BPCAs), a compound‐specific method, which allows both qualitative and quantitative estimation of PyOM. Until now, stable isotope measurement of PyOM carbon involved measurement of the trimethylsilyl (TMS) or methyl (Me) polycarboxylic acid derivatives by gas chromatography–combustion–isotope ratio mass spectrometry (GC‐C‐IRMS). However, BPCA derivatives can contain as much as 150% derivative carbon, necessitating post‐analysis correction for the accurate measurement of δ13 C values, leading to increased measurement error. Here, we describe a method for δ13 C isotope ratio measurement and quantification of BPCAs from soil‐derived PyOM, based on ion‐exchange chromatography (IEC‐IRMS). The reproducibility of the δ13 C measurement of individual BPCAs by IEC‐IRMS was better than 0.35‰ (1σ). The δ13 C‐BPCA analysis of PyOM in soils, including at natural and artificially enriched 13 C‐abundance, produced accurate and precise δ13 C measurements. Analysis of samples that differed in δ13 C by as much as 900‰ revealed carryover of <1‰ between samples. The weighted sum of individual δ13 C‐BPCA measurements was correlated with previous isotopic measurements of whole PyOM, providing complementary information for bulk isotopic measurements. We discuss potential applications of δ13 C‐BPCA measurements, including the study of turnover rates of PyOM in soils and the partitioning of PyOM sources based on photosynthetic pathways. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
6.
On the one hand, 19-norandrosterone (NA) is the most abundant metabolite of the synthetic anabolic steroid 19-nortestosterone and related prohormones. On the other hand, small amounts are biosynthesized by pregnant women and further evidence exists for physiological origin of this compound. The World Anti-Doping Agency (WADA) formerly introduced threshold concentrations of 2 or 5 ng of NA per ml of urine to discriminate 19-nortestosterone abuse from biosynthetic origin. Recent findings showed however, that formation of NA resulting in concentrations in the range of the threshold levels might be due to demethylation of androsterone in urine, and the WADA 2006 Prohibited List has defined NA as endogenous steroid. To elucidate the endogenous or exogenous origin of NA, (13)C/(12)C-analysis is the method of choice since synthetic 19-nortestosterone is derived from C(3)-plants by partial synthesis and shows delta(13)C(VPDB)-values of around -28 per thousand. Endogenous steroids are less depleted in (13)C due to a dietary mixture of C(3)- and C(4)-plants. An extensive cleanup based on two high performance liquid chromatography cleanup steps was applied to quality control and doping control samples, which contained NA in concentrations down to 2 ng per ml of urine. (13)C/(12)C-ratios of NA, androsterone and etiocholanolone were measured by gas chromatography/combustion/isotope ratio mass spectrometry. By comparing delta(13)C(VPDB)-values of androsterone as endogenous reference compound with NA, the origin of NA in doping control samples was determined as either endogenous or exogenous.  相似文献   

7.
Observations made during the 13C isotope analysis of gaseous CO2 in the simultaneous presence of argon in the ion source of the isotope ratio mass spectrometer prompted us to investigate what influence the simultaneous presence of nitrogen would have on both accuracy and precision of bulk 2H isotope analysis of nitrogen‐rich organic compounds. Initially an international reference material, IAEA‐CH7, was mixed with silver nitrate in various ratios to assess the impact that N2 evolved from the pyrolysis of nitrogen‐rich organic compounds would have on measured δ2H‐values of IAEA‐CH7. In a subsequent experiment, benzoic acid was mixed with silver nitrate to mimic the N:H ratio of organic‐rich nitrogen compounds such as cellulose nitrate and RDX. The results of both experiments showed a significant deterioration of both accuracy and precision for the expected δ2H values for IAEA‐CH7 and benzoic acid when model mixtures were converted into hydrogen and nitrogen, and subsequently separated by gas chromatography using standard experimental conditions, namely a 60 cm packed column with molecular sieve 5 Å as stationary phase held at a temperature of 85°C. It was found that bulk 2H stable isotope analysis of nitrogen‐rich organic compounds employing published standard conditions can result in a loss of accuracy and precision yielding δ2H values that are 5 to 25‰ too negative, thus suggesting, for example, that tree‐ring 2H isotope data based on cellulose nitrate may have to be revised. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The purpose of this work is to explore the mass fragment characterization of commonly used drugs through a novel approach, which involves isotope‐selective tandem mass spectrometry (MS/MS). Collision‐induced dissociation (CID) was performed with a low‐resolution linear ion trap mass spectrometer in positive electrospray ionization. Three pharmacologically active ingredients, i.e. omeprazole, meloxicam and brinzolamide, selected as model compounds in their own formulation, were investigated as a sodiated adduct [C17H19N3O3S + Na]+ (omeprazole) and as protonated adducts, [C14H13N3O4S2 + H]+ and [C12H21N3O5S3 + H]+, meloxicam and brinzolamide, respectively. Selecting a narrow window of ±0.5 m/z units, precursor ion fragmentation by CID‐MS/MS of isotopologues A + 0, A + 1 and A + 2 was found very useful to confirm the chemical formula of product ions, thus aiding the establishment of characteristic fragmentation pathways of all three examined compounds. The correctness of putative molecular formula of product ions was easily demonstrated by exploiting the isotope peak abundance ratios (i.e. IF+0/IF+1 and IF+0/IF+2) as simple constraints in low‐resolution MS instrumentations. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
10.
Liquid chromatography coupled to molecular mass spectrometry (LC/MS) has been a standard technique since the early 1970s but liquid chromatography coupled to high‐precision isotope ratio mass spectrometry (LC/IRMS) has only been available commercially since 2004. This development has, for the first time, enabled natural abundance and low enrichment δ13C measurements to be applied to individual analytes in aqueous mixtures creating new opportunities for IRMS applications, particularly for the isotopic study of biological molecules. A growing number of applications have been published in a range of areas including amino acid metabolism, carbohydrates studies, quantification of cellular and plasma metabolites, dietary tracer and nucleic acid studies. There is strong potential to extend these to new compounds and complex matrices but several challenges face the development of LC/IRMS methods. To achieve accurate isotopic measurements, HPLC separations must provide baseline‐resolution between analyte peaks; however, the design of current liquid interfaces places severe restrictions on compatible flow rates and in particular mobile phase compositions. These create a significant challenge on which reports associated with LC/IRMS have not previously focused. Accordingly, this paper will address aspects of chromatography in the context of LC/IRMS, in particular focusing on mixed‐mode separations and their benefits in light of these restrictions. It aims to provide an overview of mixed‐mode stationary phases and of ways to improve high aqueous separations through manipulation of parameters such as column length, temperature and mobile phase pH. The results of several practical experiments are given using proteogenic amino acids and nucleosides both of which are of noted importance in the LC/IRMS literature. This communication aims to demonstrate that mixed‐mode stationary phases provide a flexible approach given the constraints of LC/IRMS interface design and acts as a practical guide for the development of new chromatographic methods compatible with LC/IRMS applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
N‐Demethylation of tropine is an important step in the degradation of this compound and related metabolites. With the purpose of understanding the reaction mechanism(s) involved, it is desirable to measure the 15N kinetic isotope effects (KIEs), which can be accessed through the 15N isotope shift (Δδ15N) during the reaction. To measure the isotope fractionation in 15N during tropine degradation necessitates the extraction of the residual substrate from dilute aqueous solution without introducing artefactual isotope fractionation. Three protocols have been compared for the extraction and measurement of the 15N/14N ratio of tropine from aqueous medium, involving liquid‐liquid phase partitioning or silica‐C18 solid‐phase extraction. Quantification was by gas chromatography (GC) on the recovered organic phase and δ15N values were obtained by isotope ratio measurement mass spectrometry (irm‐MS). Although all the protocols used can provide satisfactory data and both irm‐EA‐MS and irm‐GC‐MS can be used to obtain the δ15N values, the most convenient method is liquid‐liquid extraction from a reduced aqueous volume combined with irm‐GC‐MS. The protocols are applied to the measurement of 15N isotope shifts during growth of a Pseudomonas strain that uses tropane alkaloids as sole source of carbon and nitrogen. The accuracy of the determination of the 15N/14N ratio is sufficient to be used for the determination of 15N‐KIEs. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
13.
14.
Gaseous membrane permeation (MP) technologies have been combined with continuous‐flow isotope ratio mass spectrometry for on‐line δ13C measurements. The experimental setup of membrane permeation‐gas chromatography/combustion/isotope ratio mass spectrometry (MP‐GC/C/IRMS) quantitatively traps gas streams in membrane permeation experiments under steady‐state conditions and performs on‐line gas transfer into a GC/C/IRMS system. A commercial polydimethylsiloxane (PDMS) membrane sheet was used for the experiments. Laboratory tests using CO2 demonstrate that the whole process does not fractionate the C isotopes of CO2. Moreover, the δ13C values of CO2 permeated on‐line give the same isotopic results as off‐line static dual‐inlet IRMS δ13C measurements. Formaldehyde generated from aqueous formaldehyde solutions has also been used as the feed gas for permeation experiments and on‐line δ13C determination. The feed‐formaldehyde δ13C value was pre‐determined by sampling the headspace of the thermostated aqueous formaldehyde solution. Comparison of the results obtained by headspace with those from direct aqueous formaldehyde injection confirms that the headspace sampling does not generate isotopic fractionation, but the permeated formaldehyde analyzed on‐line yields a 13C enrichment relative to the feed δ13C value, the isotopic fractionation being 1.0026 ± 0.0003. The δ13C values have been normalized using an adapted two‐point isotopic calibration for δ13C values ranging from ?42 to ?10‰. The MP‐GC/C/IRMS system allows the δ13C determination of formaldehyde without chemical derivatization or additional analytical imprecision. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Chlorine stable isotope analyses of inorganic samples were conducted using continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with gas chromatography (GC). Inorganic chloride was precipitated in the form of silver chloride (AgCl) by using silver nitrate in a standard methodology. Chlorine stable isotope analysis was carried out on methyl chloride (CH3Cl) after converting AgCl into CH3Cl by reacting it with methyl iodide (CH3I). The reaction between AgCl and CH3I took place in 20 mL size vials. Addition of CH3I was performed in a glove bag under helium flow. An Agilent 6890 gas chromatograph equipped with a CTC Analytics CombiPAL autosampler and a DB-5MS 60 m column was used to separate CH3Cl from CH3I. This new technique uses samples as small as 0.2 mg of AgCl (1.4 micromol of Cl-). The chlorine stable isotope analysis using continuous flow technology showed excellent precision and accuracy. The internal precision using pure CH3Cl gas is better than +/-0.04 per thousand (+/-STDV). The external precision using seawater standard is better than +/-0.07 per thousand (+/-STDV) for n=12. Moreover, the sample analysis time is much shorter and many more samples can be analyzed in one day than by using the conventional off-line techniques.  相似文献   

16.
A fast separation based on cation‐exchange liquid chromatography coupled with high‐resolution mass spectrometry is proposed for simultaneous determination of chlormequat, difenzoquat, diquat, mepiquat and paraquat in several food and beverage commodities. Solid samples were extracted using a mixture of water/methanol/formic acid (69.6:30:0.4, v/v/v), while liquid samples were ten times diluted with the same solution. Separation was carried out on an experimental length‐modified IonPac CS17 column (2 × 15 mm2) that allowed the use of formic acid and acetonitrile as mobile phase. Detection limits for food and beverage matrices were established at 1.5 μg/L for chlormequat, difenzoquat and mepiquat, and 3 μg/L for diquat and paraquat, while for drinking water a pre‐analytical sample concentration allowed detection limits of 9 and 20 ng/L, respectively. Precision, as repeatability (RSD%), ranged from 0.2 to 24%, with a median value of 6%, and trueness, as recovery, ranged from 64 to 118%, with a median value of 96%. The method developed was successfully applied to investigate the presence of herbicide residues in commercial commodities (mineral water, orange juice, beer, tea, green coffee bean, toasted coffee powder, cocoa bean, white corn flour, rice and sugar samples).  相似文献   

17.
18.
为推动锶同位素在水产品溯源中的应用,本文建立了基于电感耦合等离子体质谱法(ICP-MS)测定水产品中锶同位素比值的分析方法。水产品组织经冻干研磨和微波消解后,用ICP-MS测定样品溶液中的锶同位素比值,并采用标准品-样品-标准品交叉测量方法降低质量歧视效应的影响。结果表明,通过稀释样品消解溶液,将总锶浓度控制在70-100 μg/L,并与80 μg/L的锶同位素标准品溶液进行交叉测量,可准确校正质量歧视效应;84Sr/86Sr、87Sr/86Sr和88Sr/86Sr的日内精密度分别为0.06%、0.03%和0.03%,日间精密度分别为0.08%、0.04%和0.03%;按照所建立的方法测定大虾和扇贝生物成分分析标准物质的锶同位素比值,84Sr/86Sr、87Sr/86Sr和88Sr/86Sr的相对标准偏差均低于0.1%。该方法前处理简单快捷并且测量精密度高,可为锶同位素比值测定并进一步应用于水产品溯源研究提供技术支撑。  相似文献   

19.
The application of time-of-flight mass spectrometry to isotope ratio measurements has been limited by the relatively low dynamic range of the time-to-digital converter detectors available on commercial LC/ToF-MS systems. Here we report the measurement of phenylalanine isotope ratio enrichment by using a new LC/ToF-MS system with wide dynamic range. Underivatized phenylalanine was injected onto a C18 column directly with 0.1% formic acid/acetonitrile as the mobile phase. The optimal instrument parameters for the time-of-flight mass spectrometer were determined by tuning the instrument with a phenylalanine standard. The accuracy of the isotope enrichment measurement was determined by the injection of standard solutions with known isotope ratios ranging from 0.02% to 9.2%. A plot of the results against the theoretical values gave a linear curve with R2 of 0.9999. The coefficient of variation for the isotope ratio measurement was below 2%. The method is simple, rapid, and accurate and presents an attractive alternative to traditional GC/MS applications.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号