首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The number of substances nominally listed in the prohibited list of the World Anti‐Doping Agency increases each year. Moreover, many of these substances do not have a single analytical target and must be monitored through different metabolites, artifacts, degradation products, or biomarkers. A new analytical method was developed and validated for the simultaneous analysis of peptides and organic molecules using a single sample preparation and LC‐Q‐HRMS detection. The simultaneous analysis of 450 target molecules was performed after cleanup on a mixed‐mode solid‐phase extraction cartridge, combined with untreated urine. The cleanup solvent and reconstitution solvent were the most important parameters for achieving a comprehensive sample preparation approach. A fast chromatographic run based on a multistep gradient was optimized under different flows; the detection of all substances without isomeric coelution was achieved in 11 minutes, and the chromatographic resolution was considered a critical parameter, even in high‐resolution mass spectrometry detection. The mass spectrometer was set to operate by switching between positive and negative ionization mode for FULL‐MS, all‐ion fragmentation, and FULL‐MS/MS2. The suitable parameters for the curved linear trap (c‐trap) conditions were determined and found to be the most important factors for the development of the method. Only FULL‐MS/MS2 enables the detection of steroids and peptides at concentrations lower than the minimum required performance levels set by World Anti‐Doping Agency (1 ng mL−1). The combination of the maximum injection time of the ions into the c‐trap, multiplexing experiments, and loop count under optimized conditions enabled the method to be applied to over 10 000 samples in only 2 months during the 2016 Rio Summer Olympic and Paralympic Games. The procedure details all aspects, from sample preparation to mass spectrometry detection. FULL‐MS data acquisition is performed in positive and negative ion mode simultaneously and can be applied to untargeted approaches.  相似文献   

2.
The Orbitrap mass analyzer has become a mainstream mass spectrometry technique. In addition to providing a brief introduction to the Orbitrap technology and its continuing development, this article reviews the most recent publications quoting the use of the Orbitrap detection for a variety of chromatographic separation techniques. Its coupling to reversed-phase liquid chromatography (LC) represents undoubtedly the most ubiquitous approach to both small molecule and proteomic analyses. Multi-dimensional LC separations have an important role to play in the proteomics applications while an ultra-high-pressure LC is more frequently encountered in the area of metabolomics and metabolite analysis. Recently, special chromatographic techniques such as hydrophilic interaction chromatography and its variations have also been also cited with the Orbitrap detection.  相似文献   

3.
The photodegradation of paliperidone in aqueous and methanol media under UVA and UVC irradiation was investigated. The identification and structural elucidation of its photodegradation products were performed by the use of the reversed‐phase liquid chromatography coupled with accurate mass hybrid Q‐TOF mass spectrometry and an atmospheric pressure chemical ionization source. Five degradation products were found and their masses were obtained with high accuracy (1.10–5.26 ppm) based on the TOF (MS) spectra. For the structural elucidation of unknown degradation products MS/MS spectra were also registered. However, for the identification of the main photodegradation product (3‐{2‐[4‐(6‐fluoro‐1,3‐benzoxazol‐2‐yl)piperidin‐1‐yl]ethyl}‐9‐hydroxy‐2‐methyl‐6,7,8,9‐tetrahydro‐4H‐pyrido[1,2‐a]pyrimidin‐4‐one) in‐source fragmentation connected with collision‐induced dissociation was used and MS3 spectra were finally performed. The photodegradation of paliperidone yields the first‐order kinetics in all tested conditions. The aqueous medium was in this case much less stable than the methanol solvent regardless of the irradiation source. Additionally, the toxicity of the analyzed photodegradation products was predicted by the use of ECOSAR software and comparable values of LC50 for the main degradants and the parent compound were obtained. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
5.
AdipoRon is an orally active adiponectin receptor agonist. The aim of this study was to characterize the metabolites of AdipoRon in rat and human liver microsomes using ultra‐high performance liquid chromatography combined with Q‐Exactive Orbitrap tandem mass spectrometry (UPLC‐Q‐Exactive‐Orbitrap‐MS) together with data processing techniques including extracted ion chromatograms and a mass defect filter. AdipoRon (10 μm ) was incubated with liver microsomes in the presence of NADPH and this resulted in a total of 11 metabolites being detected. The identities of these metabolites were characterized by comparing their accurate masses and fragment ions as well as their retention times with those of AdipoRon using MetWorks software. Metabolites M1–M3, M6, and M8–M11 were identified for the first time. Metabolite M4, the major metabolite both in rat and human liver microsomes, was further confirmed using the reference standard. Our results revealed that the metabolic pathways of AdipoRon in liver microsomes were N‐dealkylation (M2), hydroxylation (M, M5–M9), carbonyl reduction (M4) and the formation of amide (M10 and M11). Our results provide valuable information about the in vitro metabolism of AdipoRon, which would be helpful for us to understand the mechanism of the elimination of AdipoRon and, in turn, its effectiveness and toxicity.  相似文献   

6.
Neratinib is a tyrosine kinase inhibitor that has been approved by the US Food and Drug Administration for the treatment of breast cancer. However, its metabolism remains unknown. This study was carried out to investigate the in vitro and in vivo metabolism of neratinib using an UHPLC‐DAD‐Q Exactive Orbitrap‐MS instrument with dd‐MS2 on‐line data acquisition mode. The post‐acquisition data was processed using MetWorks software. Under the current conditions, a total of 12 metabolites were detected and structurally identified based on their accurate masses, fragment ions and chromatographic retention times. Among these metabolites, M3, M10 and M12 were unambiguously identified using chemically synthesized reference standards. M6 and M7 (GSH conjugates) were the major metabolites. The metabolic pathways of neratinib were proposed accordingly. Our findings suggested that neratinib was mainly metabolized via O‐dealkylation (M3), oxygenation (M8), N‐demethylation (M10), N‐oxygenation (M12), GSH conjugation (M1, M2, M4, M5, M6 and M7) and N‐acetylcysteine conjugation (M9 and M11). The α,β‐unsaturated ketone was the major metabolic site and GSH conjugation was the predominant metabolic pathway. In conclusion, this study provided valuable metabolic data and would benefit the assessment of the contributions to the overall activity or toxicity from the key metabolites.  相似文献   

7.
The original article to which this Erratum refers was published in Rapid Commun. Mass Spectrom. 2005; 19 : 2193–2202.  相似文献   

8.
The characterization of unknown impurities present in netilmicin and sisomicin by liquid chromatography (LC) coupled with mass spectrometry (MS) is described. The volatile ion-pairing agent trifluoroacetic acid (TFA) was used for the retention of the main compounds and their impurities on a reversed-phase (RP) C18 column, because they are highly hydrophilic and basic compounds. The method showed good separation between netilmicin and its four potential related substances prescribed in the European Pharmacopoeia, which were identified by comparison of their retention times with those of the reference substances. Furthermore, in total 16 unknown impurities in a netilmicin sample and six in a sisomicin sample with unknown identity were detected. The structures of the unknown compounds were deduced based on comparison of fragmentation patterns with those of the reference substances investigated in LC/MSn experiments by the use of electrospray ion trap mass spectrometry.  相似文献   

9.
With a recently developed liquid chromatographic (LC) method, using a phosphate buffer, several unknown impurities present in dirithromycin samples were separated. In this paper, a reversed-phase liquid chromatography-tandem mass spectrometry method is described for the investigation of dirithromycin and related substances. The method employed uses a Zorbax Extend C18 column (250 mm x 4.6 mm I.D.), 5 microm, and a mobile phase consisting of acetonitrile, 2-propanol, water and ammonium acetate solution pH 8.5. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray ion (ESI) source operated in the positive ion mode. The LCQ is ideally suited for the identification of related substances because it provides on-line LC/MS(n) capability, which allows efficient identification without time-consuming isolation and purification procedures. Using this method, the fragmentation behavior of dirithromycin and its related substances was studied and the unknown impurities occurring in commercial samples were investigated. In total the structures of nine impurities were elucidated, among which three were different analogues with a modification in the side chain on the oxazine ring. Two impurities showed a different alkyl group in position C13. In two impurities the desosamine sugar was involved with changes in the degrees of methylation of the amino group. One unknown impurity was identified as dirithromycin F and another unknown was characterized as dirithromycin N-oxide.  相似文献   

10.
The structural elucidation of by-products arising from carbofuran photodegradation using a high-pressure UV lamp has been investigated by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) employing a quadrupole time-of-flight mass spectrometer. Exact mass measurements of the [M + H]+ ions of the by-products and of product ions allowed the elemental formulae and related structures of seven photodegradation by-products (resulting, respectively, from photo-Fries rearrangement, hydroxylation of the benzene ring, oxidation of the 2,3-dihydrobenzofuran ring, cleavage of the carbamate group, hydrolysis of the ether group and the newly observed radical coupling and decarboxylation processes) to be determined confidently. Accurate mass measurements of product ions allowed ambiguities to be removed concerning neutral losses having the same nominal mass, namely CO and C2H4, allowing the fragmentation patterns to be rationalized.  相似文献   

11.
A reversed-phase liquid chromatography/tandem mass spectrometry method is described for the investigation of spiramycin and related substances. The method uses an XTerra C18 column (250 x 4.6 mm i.d.), 5 microm, and a mobile phase consisting of acetonitrile, methanol, water and ammonium acetate solution, pH 6.5. Mass spectral data were acquired on an LCQ ion trap mass spectrometer equipped with atmospheric pressure chemical ionization (APCI) operated in the positive ion mode. Using this method, the fragmentation behavior of spiramycin and its related substances was studied and the unknown impurities occurring in commercial samples were investigated. In total 17 compounds were identified, among which three reported as specified impurities in the European Pharmacopoeia. The other impurities showed mainly a modification in the forosamine sugar or in the substituent at C-3 and C-6 positions. In one impurity, the mycarose sugar is absent.  相似文献   

12.
A high‐performance liquid chromatography coupled with Q‐time of flight mass spectrometry (HPLC/Q‐TOF MS) method was developed and validated for the determination of 1, 3‐diaminopropane, putrescine, cadaverine, spermidine and spermine in human plasma. The plasma samples were first pretreated by 10% HClO4 and then derived by benzoyl chloride with 1, 6‐diaminohexane as internal standard. The derived polyamines were separated on a C18 column using a gradient program. The detection was performed on a Q‐TOF MS by positive ionization mode. Calibration curve for each polyamine was obtained in the concentration range of 0.4 ~ 200.0 ng ? ml?1, with limit of detection of 0.02 ~ 0.1 ng ? ml?1. The intra‐ and inter‐day RSD for all polyamines were 2.5–14.0% and 2.9 ~ 13.4%, respectively. The method was applied to determine the polyamines in human plasma from cancer patients and healthy volunteers. Results showed that the mean levels of polyamines in the plasma of cancer patients were higher than that of healthy volunteers, which suggested that the plasma polyamines could be employed as cancer diagnostic indicators in clinical testing. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A simple and reproducible UPLC‐MS/MS method for the determination of itraconazole (ITZ) and its photodegradation products formed during exposure to UV‐A radiation was developed. Chromatographic separations were carried out using an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm particle size). The column was maintained at 40°C, and eluted under gradient conditions from 100% to 50% of eluent A over 13 min, at a flow rate of 0.3 mL min?1. Eluent A was 0.1% (v/v) formic acid in water; eluent B was 0.1% (v/v) formic acid in acetonitrile. The linear regression analysis for the calibration curve showed a good linear correlation over the concentration range 0.0066–0.15 mg mL?1 with determination coefficient > 0.99. The activities of some photocatalysts during degradation process of ITZ were compared. It was found that indirect photodegradation of ITZ was more effective than direct photolysis. Under our experimental conditions the photodegradation rate constant depended on the applied catalysts with catalytic activity decreasing in the following pattern: FeCl3 > TiO2/FeCl3 > TiO2. The kinetic analysis of the photodegradation data revealed that the degradation of the ITZ follows first‐order kinetics. The photodegradation products of ITZ were identified, and their fragmentation pathways, derived from MS/MS data, were proposed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
The photostability of guaiazulene (1,4-dimethyl-7-isopropylazulene; GA), a natural azulenic compound used in cosmetic and health-care products, as well as in pharmaceutical preparations, was investigated in solution (methanol, ethanol, acetonitrile), by different techniques: gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry and UV detection (LC/APCI-MS and HPLC/UV). A solar simulator (xenon-arc lamp) was used as UV-A radiation source. The study involved: monitoring compound decomposition, identifying products of photodegradation (PPs), assessing the role of oxygen and evaluating the kinetics of the process. Minor PPs are volatile compounds and were characterized by GC/MS, while oligomeric polyoxygenated compounds, tentatively characterized on the basis of MS and MS/MS spectra, were found to be the main photoproducts. The photodegradation was found to be enhanced by the presence of oxygen; nevertheless, determination of the singlet oxygen quantum yield for GA gave a lower value than that for the reference standard Rose Bengal. The obtained results and the developed stability-indicating methods (GC/MS and LC/MS) are of interest for stability studies and/or quality control purposes of GA as raw material or cosmetic products.  相似文献   

15.
A rapid, sensitive and reliable quantitative method based on ultra‐high performance liquid chromatography coupled with Q‐Exactive Orbitrap tandem mass spectrometry was developed for simultaneous determination of berberine, berberrubine, palmatine, jatrorrhizine, columbamine, baicalin, baicalein and wogonin in rat plasma after oral administration with Yan‐Ke‐Ning‐Tablet (YKNT). After precipitation with acetonitrile, the plasma samples were separated on a reverse‐phase C18 column with 1 mm ammonium acetate containing 0.2% acetic acid–acetonitrile as mobile phase. Calibration curves showed good linearity (r > 0.9983) over the tested concentration ranges of 0.5–200 ng/mL for berberine, berberrubine, palmatine, jatrorrhizine and columbamine, and 1–300 ng/mL for baicalin, baicalein and wogonin. The precision (relative standard deviation) at three different concentration levels was <12.15% and the accuracy (relative error) ranged from ?8.24 to 10.85%. No matrix effects were observed with matrix effect value ranging from 89.23 to 107.68%. The extraction recovery was in the range of 82.34–92.31%. The validated assay was further successfully applied to the pharmacokinetic study of these components after oral administration of YKNT. The present study provides the pharmacokinetic profiles of major bioactive components found in YKNT, and provides valuable information regarding the chemical components that were absorbed into plasma, which will be helpful for understanding the therapeutic effects of YKNT.  相似文献   

16.
Three unknown impurities in an amodiaquine bulk drug sample were detected by reversed-phase high-performance liquid chromatography with ultraviolet detection (HPLC/UV). A liquid chromatography/tandem mass spectrometry (LC/MS(n)) method is described for the investigation of these impurities. Mass spectral data were acquired on an LCQ ion trap mass analyzer equipped with an electrospray ionization (ESI) source operated in positive ion mode. The fragmentation behavior of amodiaquine and its impurities has been studied. Based on the mass spectral data and the specifics of the synthetic route, the possible structures of these impurities were elucidated as 4-[(5-chloroquinolin-4-yl)amino]-2-(diethylaminomethyl)phenol (impurity I), 4-[(7-chloroquinolin-4-yl)-amino]phenol (impurity II) and 4-[(7-chloroquinolin-4-yl)amino]-2-(diethylaminomethyl)-N(1)-oxy]phenol (impurity III). The structures were confirmed by their independent synthesis and NMR spectral assignment.  相似文献   

17.
18.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏