首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
A selective reversed-phase liquid chromatography/mass spectrometry (LC/MS(n)) method is described for the characterization of related compounds in commercial bacitracin samples. Mass spectral data for these polypeptide antibiotics were acquired on a LCQ ion trap mass spectrometer equipped with an electrospray ionization probe operated in the positive and negative ion mode. The LCQ ion trap is ideally suited for the sequencing of those linear side-chain cyclized peptides because it provides on-line LC/MS(n) capability. Using this method bacitracin A, 1-epibacitracin A, bacitracins B(1), B(2), B(3) and bacitracin F were sequenced and previous sequencing was confirmed. Bacitracins C(1), C(2), C(3), D, H(2) and H(3) were resolved chromatographically and their ring portion was sequenced for the first time. Four components not described in the literature (1-epibacitracin B(1), 1-epibacitracin B(2), 1-epibacitracin C(1) and H(4)) were sequenced completely for the first time. The main advantage of this hyphenated LC/MS(n) technique is the characterization of the related substances without time-consuming isolation and purification procedures.  相似文献   

3.
A high-performance liquid chromatography/mass spectrometry method was developed for the determination of carnitine, its biosynthetic precursor butyrobetaine, and eight acylcarnitines in plasma. The procedure includes a solid-phase extraction for carnitine and short- and medium-chain acylcarnitines, and a liquid-liquid extraction for protein-bound long-chain acylcarnitines, followed by separation on a reversed-phase column in the presence of a volatile ion-pairing reagent. Detection was achieved using an ion-trap mass spectrometer run in the tandem mass spectrometry (MS/MS) mode. The choice of the matrix for calibrators, used for quantification of these endogenous compounds, was also investigated. Validation was performed for standard quality controls diluted with 4% bovine serum albumin solution and for spiked plasma quality control samples at concentrations between 0.5 and 80 micromol/L, depending on the compound. Intra- and inter-day precisions for the determination of carnitine were below 3.4% and accuracies were between 95.2 and 109.0%. Application of the method to the diagnosis of pathological acylcarnitine profiles of metabolic disorders in a patient suffering from methylmalonic aciduria is presented. The method allows quantification of carnitine, butyrobetaine, acetylcarnitine and propionylcarnitine, and semiquantitative analysis of medium- and long-chain acylcarnitines. In contrast with other methods, no derivatization step is needed.  相似文献   

4.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

5.
6.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

7.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was used for the structural characterization and differentiation of four isomeric O-monomethylated catechins (on phenolic positions) by the analysis of the fragmentation behaviour of catechin. The catechin fragmentation routes were rationalized and it is shown that several diagnostic ions such as (1,3)A(+), (1,2)B(+), and (1,4)B(+) allow the unambiguous identification of the methylated ring. The precise position of the methyl group on each ring is determined by the difference in the relative intensities of the diagnostic ions. Isomeric O-methylepicatechins were also differentiated using this methodology.  相似文献   

8.
Searchable MS/MS spectra libraries, constructed using the results of liquid chromatography coupled with electrospray ionization (ESI) tandem mass spectrometry (LC/MS/MS) with data-dependent acquisition on an ion trap mass spectrometer, are presented with regard to the identification and confirmation of a variety of closely related flavonoids in a set of biological samples. Flavonoids were found to exhibit a maximum amount of structurally specific MS/MS spectra at 45% of normalized collision energy on the instrument used, without wideband activation. These MS/MS spectra were then searched automatically against a 297-substance MS/MS library that contains many previously acquired spectra of standard flavonoids. The possible applications of this powerful technique to biological samples are also discussed. Daidzein and genistein were identified through the MS/MS spectra library while searching through LC/MS/MS data for plant and microbial extracts. Moreover, these compounds proved completely distinguishable from other flavonoids of closely related structures in the MS/MS spectra library, using the NIST MS search program. The applicability of the library-searchable spectra at low concentrations was demonstrated by successful identification of daidzein and genistein at 0.05 and 0.5 microg/mL, respectively.  相似文献   

9.
Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and minor components can be achieved with the combination of full scan and ZoomScan using an ion trap mass spectrometer. Tandem mass spectrometry (MS/MS) provided an effective method to quickly identify most components without chromatographic separation, and all the related compounds, except the isobaric pair ECE and PdMeEA, could be identified in this way. The best result was obtained by using liquid chromatography/tandem mass spectrometry (LC/MS/MS) operated in selected reaction monitoring mode. The major compound, the estolate of erythromycin A (EAE), and seven other minor components, could be separated and identified, with semiquantitative estimates of relative concentrations.  相似文献   

10.
This paper describes a novel method to map guanine bases in short oligonucleotides using a simple chemical modification reaction and subsequent analysis by electrospray ionization ion trap mass spectrometry (ITMS). In situ guanine-specific methylation followed by gas-phase fragmentation permits the determination of the positions of all guanine residues. Collision-induced dissociation (CID) of the monomethylated oligonucleotide strand promotes rapid depurination and further collision (MS3) of the apurinic oligonucleotide leads to preferential cleavage of the backbone at the site of depurination. The mass of the resulting complementary product ions verifies the position of each guanine base in the sequence. The utility of this methodology is demonstrated for oligonucleotide sequences up to 10 bases in length. In addition, this technique successfully illustrates the use of selective fragmentation for sequencing oligonucleotides by ITMS.  相似文献   

11.
Optimization of both the ionization process and ion transportation in the mass spectrometer is of crucial importance in order to achieve high sensitivity and low detection limits and acceptable accuracy in liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) analysis. In this paper four optimization procedures of electrospray interface and quadrupole ion‐trap mass spectrometer parameters (ESI‐MS) (nebulizer gas and drying gas flow rate, end plate voltage, capillary voltage, skimmer voltage, octopoles direct current and radio frequency, trap drive and lens voltages) were studied on three pesticides – thiabendazole, aldicarb and imazalil. The results demonstrate that the methodology of optimization strongly influences the effectiveness of finding true optima of the operating parameters. Both eluent flow rate and composition during optimization have to mimic the situation during real analysis as closely as possible in order to achieve parameters giving the highest sensitivity. Therefore, post‐column addition of analyte to the mobile phase identical in composition to the one in which analyte elutes during real analysis combined with software‐based optimization was found to be the most effective and fastest method for achieving intensity maxima. The parameters most strongly affecting ion formation and transportation, hence sensitivity, were capillary voltage, direct current of the first octopole, trap drive and the second lens for all pesticides under study. In addition to sensitivity and detection limit matrix effect was considered in the optimization process. It was found that the matrix effect can be reduced but not eliminated by adjusting the ESI and MS parameters. The optimal parameters from the point of view of the matrix effect can only be found with factorial design. Parameters giving higher sensitivity tended to be more affected by matrix effect causing higher ionization suppression by co‐eluting compounds. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Auxin is an important phylohormone, which regulates specific physiological responses such as division, elongation and differentiation of cells. A new method using liquid chromatography/electrospray ionization ion trap mass spectrometry (LC/ESI-ITMS) has been developed for identification and quantitation of four auxins. Under the optimum conditions, four auxins (indole-3-acetic acid, indole-3-propionic acid, indole-3-butyric acid and 1-naphthylacetic acid) were completely separated and quantitated within 7 min with a minimum detection limit of 8.0 ng mL(-1) with relative standard deviations lower than 5.0%. This method also has been applied to analysis of auxins in Chinese cabbage where, even with a complicated serious background perturbation due to the natural biological matrix, the mean recoveries ranged from 77.5% to 99.8%. Finally, we discuss the MS-relevant properties of the identified auxins in detail.  相似文献   

13.
Fragmentation pathways of five iridoid glycosides have been studied by using electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)). The first-stage MS data of the five iridoid glycosides were compared. The MS spectra showed that the adduct ions of iridoid glycosides and the formate anion were diagnostic ions to distinguish iridoid glycosides with a carboxyl group at the C-4 position or an ester group at the C-4 position. The MS fragmentation pathways of the five iridoid glycosides were also studied. Analyzing the product ion spectra of iridoid glycosides, some neutral losses were observed, such as H(2)O, CO(2) and glucose residues, which were very useful for the identification of the functional groups in the structures of iridoid glycosides. Furthermore, specific loss of one molecule of methyl 3-oxopropanoate or 3-oxopropanic acid was firstly discussed, which corresponded to the isomerization of the hemiacetal group in the structure of iridoid aglycone. According to the fragmentation mechanisms and HPLC/MS(n) data, the structures of five iridoid glycosides in a crude extract of Gardenia jasminoisdes fruit have been identified. Three compounds were compared with standards and the other two were identified as shanzhiside and genipin gentibioside by their MS(n) data without standard compounds. In order to further validate the veracity of the deduction, genipin gentiobioside was isolated from the extract of Gardenia jasminoisdes fruit using Purification Factory and was further identified by C- and H-NMR.  相似文献   

14.
Glutathione (GSH) is a tripeptide composed of glutamate, cysteine, and glycine. It is present in practically all cells and has several important roles, such as preventing the oxidation of the sulfhydryl groups of proteins within a cell. Evidence for GSH deficiency or depletion has been found in a variety of diseases and toxicity-related studies, including diabetes and induction of oxidative stress to form reactive oxygen species which cause DNA, lipid, and protein oxidations. A simple, selective, and sensitive analytical method for measuring low levels of GSH in biological fluids would therefore be desirable to conduct GSH deficiency or depletion-related mechanistic toxicity studies. Here a method for both low- and high-level quantitation of GSH from cultured cells and rat liver tissues via liquid chromatography/positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) has been developed. The lower limit of quantitation (LOQ) of the method was 5 ng/mL. The method is linear over a wide dynamic concentration range of 5.0 to 5000.0 ng/mL, with a correlation coefficient R2 > 0.99. The intra-day assay precision relative standard deviation (RSD) values for all quality control (QC) samples were < or =16.31%, with accuracy values ranging from 94.13 to 97.80%. The inter-day assay precision RSD values for all QC samples were < or =15.94%, with accuracy values ranging from 94.51 to 100.29%. With this method, low levels of GSH from diethyl maleate (DEM)-treated mouse lymphoma cells, and GSH in rat liver tissues, were quantified.  相似文献   

15.
Eleven beta-lactam antibiotics were analyzed in fortified and incurred beef kidney tissue using high-performance liquid chromatography/electrospray ionization/selective reaction monitoring-ion trap tandem mass spectrometry (LC/ESI-SRM-MS(n)). The analytes included: deacetylcephapirin, amoxicillin, cephapirin, desfuroylceftiofur cysteine disulfide (DCCD, a biomarker of ceftiofur), ampicillin, cefazolin, Pen G, oxacillin, cloxacillin, naficillin and dicloxicillin. Analytes were extracted with acetonitrile and water. Clean-up was performed by solid-phase extraction. Limits of confirmation in fortified tissue are as follows (tolerances or target levels in parentheses): deacetylcephapirin: 10-50 ng/g (100 ng/g); amoxacillin: 50-100 ng/g (10 ng/g); cephapirin: 10 ng/g (100 ng/g); DCCD: 500 ng/g (8000 ng/g); ampicillin: 10 ng/g (10 ng/g); cefazolin: 10 ng/g (10-50 ng/g); Pen G: 10 ng/g (50 ng/g); oxacillin: 10 ng/g (10-50 ng/g); cloxacillin: 10 ng/g (10 ng/g); naficillin: 10 ng/g (10-50 ng/g); dicloxacillin: 100-500 ng/g (10-50 ng/g). The present method was also tested on incurred kidney tissue that had previously been analyzed using a microbial assay. Good correspondence was found between the results from this new method and the bioassay. However, the present method is much more specific and, in several cases, more sensitive than the bioassay. In addition, the time of analysis is significantly shorter than the bioassay. We also found that SRM MS(n) was superior in the analysis of unknown incurred tissue than full spectrum MS(n). We also obtained an MS/MS spectrum of DCCD that is significantly at variance with previously published fragmentation spectra.  相似文献   

16.
A sensitive liquid chromatography/ion trap tandem mass spectrometry method was developed for the qualitative and quantitative detection of isocyanates in air. The method is based on derivatization of isocyanates with 1-(2-methoxyphenyl)piperazine during air sampling. The extracts are analyzed using an ion trap LC/MS system equipped with an electrospray (ESI) ion source. The method shows high linearity, specificity, accuracy and precision. The limits of detection are 40x to 55x lower than with UV-based methods.  相似文献   

17.
Midazolam (MDZ), a short-acting benzodiazepine, is a widely accepted probe drug for CYP3A phenotyping. Published methods for its analysis have used either therapeutic doses of MDZ, or, if employing lower doses, were mostly unable to quantify the two hydroxy metabolites. In the present study, a sensitive and specific liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantitative determination of MDZ and two of its metabolites (1'-hydroxymidazolam (1'-OHMDZ) and 4-hydroxymidazolam (4-OHMDZ)) in human plasma and oral fluid. After liquid-liquid extraction with hexane/dichloromethane (73:27, v/v), the analytes were separated on a Luna C18(2) (100 x 2.1 mm) analytical column using gradient elution. Detection was achieved using tandem mass spectrometry on an ion trap mass spectrometer. Midazolam-d6 was used as internal standard for quantification. The calibration curves were linear (R2 >0.998) between 0.05 and 20 ng/mL for MDZ and both metabolites in both matrices. Using 1 mL samples, the limit of detection was 0.025 ng/mL and the limit of quantification was 0.05 ng/mL for MDZ and the hydroxy metabolites in both matrices. Intra- and inter-day accuracies, determined at three different concentrations, were between 92.1 and 102.3% and the corresponding coefficients of variation were <7.3%. The average recoveries were 90.6%, 86.7% and 79.0% for MDZ, 1'-OHMDZ and 4-OHMDZ in plasma and 95.3%, 96.6% and 86.8% for MDZ, 1'-OHMDZ and 4-OHMDZ, respectively, in oral fluid. The method was successfully applied to a pharmacokinetic study, showing that MDZ and its hydroxy metabolites can be determined precisely in in vivo samples obtained following a single oral or intravenous dose of 2 mg MDZ. The method appears to be useful for CYP3A phenotyping in plasma using sub-therapeutic MDZ doses, but larger studies are needed to test this assumption.  相似文献   

18.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented.  相似文献   

19.
The applicability of ion-pair reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry (IP-RP-HPLC/ESI-MS) and direct infusion/ESI-MS to the characterization of nucleic acid mixtures was evaluated by the analysis of the reaction products obtained from solid-phase synthesis of a 39-mer oligonucleotide. IP-RP-HPLC/ESI-MS was performed using 200 microm i.d. capillary columns packed with octadecylated, micropellicular poly(styrene-divinylbenzene) particles and applying gradients of acetonitrile in 50 mM triethylammonium bicarbonate (TEAB). Three different solvent systems were utilized for direct infusion/ESI-MS with removal of metal cations by on-line cation exchange: (1) 10 mM triethylamine (TEA) in 50% aqueous acetonitrile, (2) 2.2 mM TEA, 400 mM hexafluoro-2-propanol (HFIP) in 20% aqueous methanol and (3) 50 mM TEAB in 10% aqueous acetonitrile. Owing to its separation capability, the highest selectivity and specificity were achieved with IP-RP-HPLC/ESI-MS, which, apart form the 39-mer target sequence, allowed the identification of two isobutyryl-protected target sequences and a 10-mer and 20-mer failure sequence. Direct infusion/ESI-MS with TEA-acetonitrile or TEA-HFIP-methanol as solvent revealed signals for the 39-mer in the m/z range 700-1600. The presence of derivatives containing one, two, three and four isobutyryl groups indicated that the hydrolysis of the protecting groups after solid-phase synthesis was not complete. Failure sequences could not be identified by direct infusion/ESI-MS under conditions favoring multiple charging of the analytes owing to the high chemical background and coincidental overlapping of m/z signals. However, efficient charge state reduction upon addition of carbonic acid to the electrosprayed solvent shifted the signals of the 39-mer and derivatives to m/z values >2400 and allowed the detection of seven different failure sequences, ranging from the 8-mer to the 23-mer, in the mixture.  相似文献   

20.
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural information on the sugar sequences of the saccharide chains and on the sapogins of saponins. By ESI-MS(n), non-isomeric saponins and isomeric saponins with different aglycones can be determined rapidly in plant extracts. LC/MS/MS is a good complementary analytical tool for determination of isomeric saponins. These approaches constitute powerful analytical tools for rapid screening and structural assignment of saponins in plant extracts.  相似文献   