首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hui Xu  Xiwen Zeng  Huiling Dai 《中国化学》2011,29(10):2165-2168
A new fluorescent chemosensor based upon 1,8‐naphthalimide and 8‐hydroxyquinoline was synthesized, and its fluorescent properties in the presence of different metal cations (Hg2+, Ag+, Zn2+, Fe2+, Cd2+, Pb2+, Ca2+, Cu2+, Mg2+, and Ba2+) were investigated. It displayed fluorescence quenching with some heavy and transition metal (HTM) ions, and the quenching strongly depended on the nature of HTM ions.  相似文献   

2.
A series of novel double‐armed p‐(tert‐butyl)calix[4]arenes, carrying benzoylamido, 4‐nitrobenzoylamido, isonicotinamido, α‐naphthamido, acetamido, propionamido, or butyramido groups (see 2 – 8 , resp.) were synthesized in 80 – 86% yield by the reaction of the lower‐rim 1,3‐bis(aminoethoxy)‐substituted calix[4]arenediol 1 with the corresponding acylating agents. Their structures were established by elemental analysis, mass, IR, UV, and 1H‐NMR spectroscopy. Ion‐selective electrodes (ISEs) for Pb2+, carrying 2 – 8 in a PVC membrane as neutral ionophore, were prepared, and their selectivity coefficients for Pb2+ (K) were determined against other heavy‐metal ions, alkali and alkaline earth metal ions, and ammonium ions by means of the separate‐solution method. The results obtained indicated that the electrodes based on the calix[4]arene‐derived amides 2 – 8 as the neutral ionophores were all Pb2+ selective and exhibited almost theoretical Nernstian slopes, except for 3 and 4 . Typically, the Pb2+‐selective electrode based on 6 – 8 exhibited almost Nernstian slopes for Pb2+ over a relatively wide concentration range and had a fast response time as well as a long lifetime, although the silver ion interfered strongly. These ISEs based on 6 – 8 showed a relatively good Pb2+ selectivity against most of the interfering cations examined, except for Ag+. The effect of the side‐arm functions of calix[4]arene derivatives 2 – 8 on the Nernstian slopes and on the selectivity coefficients for Pb2+ obtained with the Pb2+ ISEs based on 2 – 8 is discussed.  相似文献   

3.
Abstract : It is well known that copper ions play a critical role in various physiological processes. However, a variety of human diseases are tightly correlated with copper overload. Although there are numerous fluorescent probes capable of detecting copper ions, most of them are “turn‐off” probes owing to copper (II) ions fluorescence quenching effect, resulting in poor sensitivity. Herein, a novel “turn‐on” near‐infrared (NIR) fluorescent probe PZ‐N based on phenoxazine was designed and synthesized for the selective detection of copper (II) ions (Cu2+). Upon the addition of Cu2+, the probe could quickly react with Cu2+ and emit strong fluorescence, along with colour change from colourless to obvious blue. Moreover, the probe PZ‐N showed good water solubility, high selectivity, and excellent sensitivity with low limit of detection (1.93 nM) towards copper (II) ions. More importantly, PZ‐N was capable of effectively detecting Cu2+ in living cells.  相似文献   

4.
A new chemosensor for Cu2+ was synthesized based on 1,2,3,4,5,6,7,8,9,10‐decahydroacridine‐1,8‐dione dyes, which exhibited an obvious fluorescent selectivity to the sensing of Cu2+ ions over other cations, such as Na+, K+, Ca2+, Cd2+, Co2+, Hg2+, Mg2+, Mn2+, Ni2+, Zn2+, Ag+ and Pb2+. Moreover, it presented a fluorescent switch function when EDTA was added to the compound‐Cu2+ complex in examined systems.  相似文献   

5.
A new ratiometric fluorescent sensor ( 1 ) for Cu2+ based on 4,4‐difluoro‐4‐bora‐3a,4a‐diaza‐s‐indacene (BODIPY) with di(2‐picolyl)amine (DPA) as ion recognition subunit has been synthesized and investigated in this work. The binding abilities of 1 towards different metal ions such as alkali and alkaline earth metal ions (Na+, K+, Mg2+, Ca2+) and other metal ions ( Ba2+, Zn2+, Cd2+, Fe2+, Fe3+, Pb2+, Ni2+, Co2+, Hg2+, Ag+) have been examined by UV‐vis and fluorescence spectroscopies. 1 displays high selectivity for Cu2+ among all test metal ions and a ~10‐fold fluorescence enhancement in I582/I558 upon excitation at visible excitation wavelength. The binding mode of 1 and Cu2+ is a 1:1 stoichiometry determined via studies of Job plot, the nonlinear fitting of the fluorometric titration and ESI mass.  相似文献   

6.
《Electroanalysis》2017,29(7):1712-1720
[14]Tetraazaannulene derivatives 1–4 with various substituents were synthesized as ion recognition compounds. All solvent polymeric membrane electrodes incorporating [14]tetraazaannulene derivatives 1–4 showed rapid response for the Cu2+ ion and exhibited excellent selectivity over other mono‐ and divalent cations such as Ag+ and Ni2+ ions. The solvent polymeric membrane electrode based on [14]tetraazaannulene derivative 1 has a linear response to the Cu2+ ion from 5.01 × 10−7 – 2.63 × 10−4 M with a slope of 29.56 mV per decade. DFT calculations showed that the selectivities for the Cu2+ ion of the ISEs based on [14]tetraazaannulene derivatives 1–4 depended on both their topological and electrostatic properties caused by the introduced substituents.  相似文献   

7.
《Electroanalysis》2005,17(4):327-333
Conducting polymers (CP) remain a promising material to construct stable potential all‐solid‐state ion‐selective potentiometric electrodes. The unique properties of poly(3,4‐ethylenedioxythiophene) doped with poly(4‐styrenesulfonate) ions, PEDOT‐PSS: high CP stability and affinity of doping anions towards Cu2+ ions, make it highly attractive for construction of all‐solid‐state copper(II)‐selective electrodes with outstanding selectivity. The additional benefits can arise from solution processability of commercially available PEDOT‐PSS system. This material was highly promising for a new sensor arrangement, i.e. to obtain disposable, planar and flexible all‐plastic Cu2+‐selective electrodes. These sensors can be obtained by casting a commercially available dispersion of PEDOT‐PSS (Baytron P) on a plastic, non‐conducting support material. The CP being both electrical lead and ion‐to‐electron transducer, was covered with plastic, solvent polymeric Cu2+ selective membrane. This extremely simple arrangement, after conditioning in dilute Cu2+ solution, was characterized with linear Nernstian responses within the activities range from: 0.1 to 10?4 M, followed by super‐Nernstian responses for lower activities. The latter result points to effective elimination of primary ions leakage from the plastic membrane / transducer phase and has resulted in significantly improved selectivities. Obtained log K values were equal to ?7.6 for Co2+, ?7.4 for Zn2+, ?7.2 for Ca2+ and ?6.8 for Na+, respectively.  相似文献   

8.
A luminescent cadmium–pamoate metal–organic framework, [Cd2(PAM)2(dpe)2(H2O)2]?0.5(dpe) ( 1 ), has been synthesized under hydrothermal conditions by using π‐electron‐rich ligands 4,4′‐methylenebis(3‐hydroxy‐2‐naphthalenecarboxylic acid) (H2PAM) and 1,2‐di(4‐pyridyl)ethylene (dpe). Its structure is composed of both mononuclear and dinuclear CdII building units, which are linked by the PAM and dpe ligands, resulting in a (4,8)‐connected 3D framework. The π‐conjugated dpe guests are located in a 1D channel of 1 . The strong emission of 1 could be quenched efficiently by trace amounts of 2,4,6‐trinitrophenol (TNP), even in the presence of other competing analogues such as 4‐nitrophenol, 2,6‐dinitrotoluene, 2,4‐dinitrotoluene, nitrobenzene, 1,3‐dinitrobenzene, hydroquinone, dimethylbenzene, and bromobenzene. The high sensitivity and selectivity of the fluorescence response of 1 to TNP shows that this framework could be used as an excellent sensor for identifying and quantifying TNP. In the same manner, 1 also exhibits superior selectivity and sensitivity towards Cu2+ compared with other metal ions such as Zn2+, Mn2+, Mg2+, K+, Na+, Ni2+, Co2+, and Ca2+. This is the first MOF that can serve as a dual functional fluorescent sensor for selectively detecting trace amounts of TNP and Cu2+.  相似文献   

9.
The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10?1–1.0×10?6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10?7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples.  相似文献   

10.
《中国化学》2017,35(8):1311-1316
Specific recognition of ultratrace levels of ions in semi‐water using super‐quicker methods is still a challenge for environmental monitoring. Herein we report a fluorescent and colormetric sensor ( ZH ) based on supramolecular self‐assembly, whose structure was destroyed by the addition of ultratrace of silver ions. The process promoted either naked eye visible color changes or fluorescence intensity quenched in conjunction with a wide pH range. Systematic studies revealed very high selectivity (0.07 µmol/L) for silver ions, and other common cations, e.g ., Hg2+, Cu2+, Cd2+, Pb2+ had nearly no influence on the sensing behavior. This sensor also served as a multiple use of component in sensing materials by addition of I into the mixture of ZH and Ag+ (about 5 times). What's more, ZH containing filter paper emerged distinct color and fluorescence changes upon exposure to silver (Ag+), which could be used as a portable method to undertake field testing for Ag + .  相似文献   

11.
We report the synthesis and analytical application of the first Cu2+‐selective synthetic ion channel based on peptide‐modified gold nanopores. A Cu2+‐binding peptide motif (Gly‐Gly‐His) along with two additional functional thiol derivatives inferring cation‐permselectivity and hydrophobicity was self‐assembled on the surface of gold nanoporous membranes comprising of about 5 nm diameter pores. These membranes were used to construct ion‐selective electrodes (ISEs) with extraordinary Cu2+ selectivities, approaching six orders of magnitude over certain ions. Since all constituents are immobilized to a supporting nanoporous membrane, their leaching, that is a ubiquitous problem of conventional ionophore‐based ISEs was effectively suppressed.  相似文献   

12.
Novel PVC membrane (PME) and coated graphite (CGE) Cu2+‐selective electrodes based on 5,6,7,8,9,10‐hexahydro‐2H‐1,13,4,7,10‐benzodioxatriazacyclopentadecine‐3,11(4H,12H)‐dione are prepared. The electrodes reveal a Nernstian behavior over wide Cu2+ ion concentration ranges (1.0×10?7–1.0×10?1 M for PME and 1.0×10?8–1.0×10?1 M for CGE) with very low limits of detection (7.8×10?8 M for PME and 9.1×10?9 M for CGE). The potentiometric responses are independent of the pH of the test solutions in the pH range 2.7–6.2. The proposed electrodes possess very good selectivities for Cu2+ over a wide variety of the cations including alkali, alkaline earth, transitions and heavy metal ions. The practical utility of the proposed electrodes have been demonstrated by their use in the study of interactions between copper ions and human growth hormone (hGH) in biological systems, potentiometric titration of copper with EDTA and determination of copper content of a sheep blood serum sample and some other real samples.  相似文献   

13.
Two novel 25,27-dihydroxy-26,28-bis(3-phenylthiapropxy)-calix[4]arene(3) and 25,27-dihydroxy-26,28-bis(3-phenylthiapropoxy)-5,11,17,23-tetra-tert-butylcalix[4] arene (4) were synthesized for the evaluation of their ion-selectivity in ion-selective electrodes(ISEs).ISEs based on 3 and 4 as neutral ionophores were prepared,and their selectivity coefficients for Ag^ (lg KAg,M^pot)were investigated against other alkali metal,alkaline-earth metal,aluminum,thallium(Ⅰ),Lead and some transition metal ions using the separate solution method (SSM).These ISEs showed excellent Ag^ seletivity over most of the interfering cations examined,except for Hg^2 and Fe^2 having relative smaller interference(lg KAg,M^pot≤-2.1).  相似文献   

14.
Two well‐defined triphenylamine‐based fluorescent conjugated copolymers with pendant terpyridyl ligands were synthesized through Suzuki coupling polymerization and were further characterized by 1H‐NMR, 13C‐NMR, gel permeation chromatography, Infrared, and UV‐vis spectra. Polymer P‐1 , terpyridine‐bearing poly(triphenylamine‐alt‐fluorene) with a high fluorescence quantum yield (62%) shows much higher sensitivities toward Fe3+, Ni2+, and Cu2+ as compared with the other metal ions investigated. Especially, Fe3+ can lead to an almost complete fluorescence quenching of polymer P‐1 . Whereas, the analogous polymer P‐2 , in which N‐ethylcarbazole repeat units replace the fluorene units in P‐1 , shows a very poor selectivity. It demonstrates that polymers with a same receptor may show different sensitivity to analytes owing to their different type of backbones. © 2010 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 48: 1310–1316, 2010  相似文献   

15.
The competitive removal of Pb2+, Cu2+, and Cd2+ ions from aqueous solutions by the copolymer of 2‐acrylamido‐2‐methyl‐1‐propane sulfonic acid (AMPS) and itaconic acid (IA), P(AMPS‐co‐IA), was investigated. Homopolymer of AMPS (PAMPS) was also used to remove these ions from their aqueous solution. In the preparation of AMPS–IA copolymer, the molar percentages of AMPS and IA were 80 and 20, respectively. In order to observe the changes in the structures of polymers due to metal adsorption, FTIR spectra by attenuated total reflectancetechnique and scanning electron microscopy (SEM) pictures of the polymers were taken both before and after adsorption experiments. Total metal ion removal capacities of PAMPS and P(AMPS‐co‐IA) were 1.685 and 1.722 mmol Me2+/gpolymer, respectively. Experimental data were evaluated to determine the kinetic characteristics of the adsorption process. Competitive adsorption of Pb2+, Cu2+, and Cd2+ ions onto both PAMPS and P(AMPS‐co‐IA) was found to fit pseudo‐second‐order type kinetics. In addition, the removal orders in the competitive adsorption of these metal ions onto PAMPS and P(AMPS‐co‐IA) were found to be Cd2+ > Pb2+ > Cu2+ and Pb2+ > Cd2+ > Cu2+, respectively. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
In the present study, surface‐enhanced Raman spectra of a bifunctional Raman reporter, 2‐mercaptobenzimidazole, has been found to be responsive exclusively towards Cu2+ ions while the reporter remains anchored on the Au nanoparticle surface. Thus a specific Cu2+‐ion‐detection protocol emerges. The simplicity, sensitivity, and reproducibility of the method allow routine and quantitative detection of Cu2+ ions. An interference study involving a wide number of other metal ions shows the procedure to be uniquely selective and analytically rigorous. A theoretical study was carried out to corroborate the experimental results. Finally, the method is promising for real‐time assessment of Cu2+ ions in aqueous samples and also has the ability to discriminate CuI and CuII ions in solution.  相似文献   

17.
Herein, we report a new kind of highly fluorescent probe for Cu2+ sensing generated by hydrothermal treatment of graphene quantum dots (GQDs). After hydrothermal treatment in ammonia, the greenish‐yellow fluorescent GQDs (gGQDs) with a low quantum yield (QY, 2.5 %) are converted to amino‐functionalized GQDs (afGQDs) with a high QY (16.4 %). Due to the fact that Cu2+ ions have a higher binding affinity and faster chelating kinetics with N and O on the surface of afGQDs than other transition‐metal ions, the selectivity of afGQDs for Cu2+ is much higher than that of gGQDs. Furthermore, afGQDs are biocompatible and eco‐friendly, and the afGQDs with a positive charge can be easily taken up by cells, which makes it possible to sense Cu2+ in living cells. The strategy presented here is simple in design, economical, and offers a “mix‐and‐detect” protocol without dye‐modified oligonucleotides or complex chemical modification.  相似文献   

18.
Herein a ratiometric fluorescent Cu2+ probe was rationally constructed in a straightforward manner with the concept of aldehyde group protection/deprotection. The probe showed a ratiometric fluorescent response to Cu2+ with a large emission wavelength shift (>100 nm) and displayed high selectivity for Cu2+ over other metal ions due to distinct deprotection conditions. In addition, a Cu2+‐promoted dethioacetalization mechanism was proposed.  相似文献   

19.
The potentiometric characteristics of a new Cu2+‐selective electrode based on 2‐(benzyliminomethyl)‐6‐methoxy‐4‐(4‐methoxyphenyl‐azo) phenol as an efficient ionophore has been evaluated. The effects of influential parameters on the potentiometric responses such as the amount of plasticizer, the amount of ionophore, pH of the sample solution, and the effect of coexisting ions on the electrode signal were subsequently investigated . The selectivity of the electrode was assessed by calculating the selectivity coefficients using the matched potential method. The optimum ratio of the amount of materials required for the preparation of the electrode was found to be 1.7: 32.1: 64.2: 2.0 corresponding to carboxylated PVC, dimethyl sebacate as solvent mediators, potassium tetrakis (p‐chlorophenyl) borate as the anion localizing agent, and ionophore, respectively. The electrode had a fast response (7s) as well as a satisfactory Nernstian slope (29.26±0.91 mV/decade) to Cu2+ over a wide concentration range of 2.0×10?6‐ 5.0×10?2 M with a low detection limit of 5.9×10?7 M. The developed sensor was successfully used for the potentiometric titration of Cu2+ ion with EDTA and subsequently, efficient determination of this metal ion in a mineral water sample was performed.  相似文献   

20.
New amphiphilic gelators that contained both Schiff base and L ‐glutamide moieties, abbreviated as o‐SLG and p‐SLG, were synthesized and their self‐assembly in various organic solvents in the absence and presence of metal ions was investigated. Gelation test revealed that o‐SLG formed a thermotropic gel in many organic solvents, whilst p‐SLG did not. When metal ions, such as Cu2+, Zn2+, Mg2+, Ni2+, were added, different behaviors were observed. The addition of Cu2+ induced p‐SLG to from an organogel. In the case of o‐SLG, the addition of Cu2+ and Mg2+ ions maintained the gelating ability of the compound, whilst Zn2+ and Ni2+ ions destroyed the gel. In addition, the introduction of Cu2+ ions caused the nanofiber gel to perform a chiral twist, whilst the Mg2+ ions enhanced the fluorescence of the gel. More interestingly, the Mg2+‐ion‐mediated organogel showed differences in the fluorescence quenching by D ‐ and L ‐tartaric acid, thus showing a chiral recognition ability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号