首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 182 毫秒
1.
The detection and removal of bacteria, such as E. coli in aqueous environments by using safe and readily available means is of high importance. Here we report on the synthesis of nanodiamonds (ND) covalently modified with specific carbohydrates (glyco-ND) for the precipitation of type 1 fimbriated uropathogenic E. coli in solution by mechanically stable agglutination. The surface of the diamond nanoparticles was modified by using a Diels-Alder reaction followed by the covalent grafting of the respective glycosides. The resulting glyco-ND samples are fully dispersible in aqueous media and show a surface loading of typically 0.1 mmol g(-1). To probe the adhesive properties of various ND samples we have developed a new sandwich assay employing layers of two bacterial strains in an array format. Agglutination experiments in solution were used to distinguish unspecific interactions of glyco-ND with bacteria from specific ones. Two types of precipitates in solution were observed and characterized in detail by light and electron microscopy. Only by specific interactions mechanically stable agglutinates were formed. Bacteria could be removed from water by filtration of these stable agglutinates through 10 μm pore-size filters and the ND conjugate could eventually be recovered by addition of the appropriate carbohydrate. The application of glycosylated ND allows versatile and facile detection of bacteria and their efficient removal by using an environmentally and biomedically benign material.  相似文献   

2.
For better understanding and improving the non‐covalent interactions of dendritic core–shell, we evaluated the interactions of hyperbranched poly(ethylene imine) (PEI) decorated with various oligosaccharide shells with water‐soluble B vitamins, an estradiol derivative and pantoprazole. Depending on the different properties of the analyte molecules, dendritic core–shell glyco architectures showed (very) weak, moderate and strong interactions with the analyte molecules. Thus, ionic interactions are the strongest driving force for the formation of host–guest complexes. The core–shell glyco architecture is a necessary prerequisite for stable analyte/PEI complexes; the pure hyperbranched PEI did not show any sufficiently strong interactions with neutral, cationic or anionic analytes under the shear forces applied during ultrafiltration of pure aqueous solution without an adjusted pH. Thus, only robust non‐covalent interactions between analytes and the dendritic polyamine scaffold of the glycopolymer structure survive this separation step and allow isolation of stable host–guest complexes in aqueous solution.  相似文献   

3.
We report a new approach for immunoassays based on magnetite nanoparticles for Escherichia coli (E. coli) detection using conductometric measurements. Biotinylated antibodies, anti-E. coli, were immobilized on streptavidin modified magnetite nanoparticles by biotin–streptavidin interaction. A layer of functionalized nanoparticles were directly immobilized on the conductometric electrode using glutaraldehyde cross-linking.The specific test with E. coli cells and the non specific test using Staphylococcus epidermidis (S. epidermidis) were investigated by conductometric measurements. Results show a good response as a function of antigen additions. The detection of 1 CFU/ml of E. coli induces a conductivity variation of 35 μS. The negative test shows good selectivity using the conductometric immunosensor. Conductometric measurements allow to detect 500 CFU/l.  相似文献   

4.
The detection and identification of dilute bacterial samples by surface-enhanced Raman spectroscopy has been explored by mixing aqueous suspensions of bacteria with a suspension of nanocolloidal silver particles. An estimate of the detection limit of E. coli was obtained by varying the concentration of bacteria. By correcting the Raman spectra for the broad librational OH band of water, reproducible spectra were obtained for E. coli concentrations as low as approximately 103 cfu/mL. To aid in the assignment of Raman bands, spectra for E. coli in D2O are also reported. Figure Light scattering apparatus used to detect bacteria  相似文献   

5.
铂纳米颗粒修饰电极对大肠杆菌的电化学快速检测   总被引:2,自引:0,他引:2  
本文采用了电化学沉积法制备了铂纳米颗粒化学修饰电极(PtNP/GCE),并将它应用于大肠杆菌的检测。原理是基于检测大肠杆菌溶液中酶与底物的反应产物,对氨基酚,实现了对大肠杆菌的快速检测。采用了铂纳米颗粒修饰电极,并对检测系统进行优化,提高大肠杆菌的检测灵敏度。大肠杆菌浓度在50—1.0×105cfu/ml与响应电流成良好的线性关系,最低检测限为20 cfu/ml,检测时间在4个小时以内。与传统方法相比,该电化学方法能很好地满足食品安全、环境监控和临床医学等领域中快速检测的要求。  相似文献   

6.
Yuxiao Cheng 《Talanta》2009,77(4):1332-95
A rapid, specific and sensitive method for assay of Escherichia coli (E. coli) using biofunctional magnetic nanoparticles (BMNPs) in combination with adenosine triphosphate (ATP) bioluminescence was proposed. The BMNPs were fabricated by immobilizing a specific anti-E. coli antibody on the surface of amine-functionalized magnetic nanoparticles (about 20 nm in diameter), and then was applied to capture the target bacteria E. coli from samples. The BMNPs exhibited high capture efficiency to E. coli. Transmission electron microscope (TEM) images showed that the BMNPs were bound to the surface of entire E. coli cells. The target bacteria became magnetic so that could be isolated easily from the sample solution by employing an external magnetic field. The concentration of E. coli captured by the BMNPs was then detected by an ATP bioluminescence method. The optimization of ATP measurement was carried out to improve the detection sensitivity. The proposed method was applied to detect the E. coli inoculated into pasteurized milk with low detection limit (20 cfu/mL) and short detection time (about 1 h).  相似文献   

7.
We report glyco‐pseudopolyrotaxanes composed of cucurbit[6]uril‐based mannose wheels (ManCB[6]) threaded on polyviologen (PV), which not only effectively induce bacterial aggregation, but also exhibit high inhibitory activity against bacterial binding to host cells. Three glyco‐pseudopolyrotaxanes ( 1 – 3 ), which have 10, 5, and 3 ManCB[6] wheels, respectively, on a PV string, were prepared and characterized. Bacterial aggregation assays and hemagglutination inhibition assays illustrated the specific and multivalent interaction between the glyco‐pseudopolyrotaxanes and E. coli ORN178. Compound 3 was especially effective at inducing bacterial aggregation and showed 300 times higher inhibitory potency than monomeric methyl‐α‐mannoside (Me‐αMan) for ORN178‐induced hemagglutination. Furthermore, we demonstrated their inhibitory activities for the adhesion of ORN178 bacteria to urinary epithelial cells as a model of urinary tract infection. Our findings suggest that these supramolecular carbohydrate clusters are potentially useful in antiadhesion therapy.  相似文献   

8.
A rapid and cost-effective method to specifically identify and quantify pathogenic Escherichia coli (E. coli) bacteria in aqueous samples and food products is highly recommended to avoid the degradation of human health that can unfortunately lead to fatal cases. To overcome these borderline situations, portable and easy-to-use screening devices are needed for the non-expert public and confirmed by medical personnel/physicians who can quickly guide/prescribe antibiotic treatments. In such a context, nanotechnologies are very promising and useful tools due to the remarkable optical, chemical and physical properties of biocompatible nanomaterials deposited or synthesized on traditional solid electrodes that greatly improve the detection limit and the selectivity of nanostructured-based biosensors. With this in mind, this review summarizes the latest advances in the bioelectrochemical detection of E. coli and its related products using different biosensor configurations in saline buffers and spiked real samples, namely food products (milk, fruits, vegetables), body fluids (blood, urine, swine feces) and river water.  相似文献   

9.
Available online Development of water soluble AIE-active “light-up” bioprobes for the detection of biomacromolecules has drawn huge research interests in recent past. In this study, a series of ethylene glycol modified water soluble tetrameric tetraphenylethylene amphiphiles with pyridinium polar heads (TPE-xEG-Py, x = 3, 4, 6 or 1a-c) have been synthesized by varying the ethylene glycol spacer. Their unique structure allows them to form vesicles and other nanoaggregates in aqueous solutions. These amphiphiles were successfully utilized for fluorimetric detection and quantitation of BSA and DNA based on the electrostatic interactions to trigger AIE-emission from the TPE moiety. The electrostatic interaction was also proved very effective in wash-free imaging of both Gram-negative (E. coli) and Gram-positive (S. aureus) bacteria with up to 92 folds increase in fluorescence response within bacterial concentration 0–12 × 108 CFU mL?1. The strategy is advantageous due to cost-effective and easy synthesis, high water solubility, and fast response.  相似文献   

10.
Mannose-coated CdS quantum dots (Man-QDs) were prepared in a facile aqueous, one-pot process that exploits the self-assembly of thiolated mannose in the presence of CdS under reducing conditions. The resulting ∼15 nm diameter nanoparticles produce an intense, broad luminescence emission centred at 550 nm. These Man-QDs induce luminescent aggregates of Escherichia coli which can be used to detect bacteria in cell suspensions containing as few as 104E. coli per mL. The aggregation process is dependent on the E. coli cell surface FimH mannose-specific lectin. The recognition and subsequent detection of the E. coli using the Man-QD has been shown to be specific as aggregation does not occur either with an E. coli strain defective in the FimH lectin or with galactose-coated QDs.  相似文献   

11.
Early detection of pathogenic microorganisms is pivotal to diagnosis and prevention of health and safety crises. Standard methods for pathogen detection often rely on lengthy culturing procedures, confirmed by biochemical assays, leading to >24 h for a diagnosis. The main challenge for pathogen detection is their low concentration within complex matrices. Detection of blood-borne pathogens via techniques such as PCR requires an initial positive blood culture and removal of inhibitory blood components, reducing its potential as a diagnostic tool. Among different label-free microfluidic techniques, inertial focusing on microscale channels holds great promise for automation, parallelization, and passive continuous separation of particles and cells. This work presents inertial microfluidic manipulation of small particles and cells (1–10 μm) in curved serpentine glass channels etched at different depths (deep and shallow designs) that can be exploited for (1) bacteria preconcentration from biological samples and (2) bacteria-blood cell separation. In our shallow device, the ability to focus Escherichia coli into the channel side streams with high recovery (89% at 2.2× preconcentration factor) could be applied for bacteria preconcentration in urine for diagnosis of urinary tract infections. Relying on differential equilibrium positions of red blood cells and E. coli inside the deep device, 97% red blood cells were depleted from 1:50 diluted blood with 54% E. coli recovered at a throughput of 0.7 mL/min. Parallelization of such devices could process relevant volumes of 7 mL whole blood in 10 min, allowing faster sample preparation for downstream molecular diagnostics of bacteria present in bloodstream.  相似文献   

12.
《Analytical letters》2012,45(9):2155-2166
Abstract

A piezoelectric crystal biosensor system was applied to the detection of Escherichia coli. the system consists of an oscillator, a frequency counter, a flow cell and a modified piezoelectric crystal. Anti-E. coli antibody is immobilized on the surface of the crystal. It is used as an E. coli detection by measuring its resonant frequency shift due to a mass change caused by specific binding of the micro organisms to the surface. the frequency shift correlates with an E. coli concentration in the range of 106?108 cells·cm?3. the resonant frequency shift is increased by further treatment to bind micro-particles modified with anti-E. coli antibody. This method allows us to improve the determination limit to 105 cells · cm?3.  相似文献   

13.
Living Micrococcus luteus (M. luteus) and Escherichia coli (E. coli) are encapsulated in poly(vinyl alcohol), poly(vinylpyrrolidone), hydroxypropyl cellulose, and gelatin by high‐temperature spray drying. The challenge is the survival of the bacteria during the standard spray‐drying process at temperatures of 150 °C (M. luteus) and 120 °C (E. coli). Raman imaging and transmission electron microscopy indicate encapsulated bacteria in hollow composite microparticles. The versatility of the spray‐dried polymer bacteria microparticles is successfully proved by standard polymer solution–processing techniques such as electrospinning, even with harmful solvents, to water‐insoluble polyacrylonitrile, polystyrene, poly(methyl methacrylate), and poly(vinyl butyrate) nanofiber nonwovens, which opens numerous new opportunities for novel applications.  相似文献   

14.
An electrochemical biosensor was developed for the determination of Escherichia coli (E. coli) in water. For this purpose, silver‐gold core‐shell (Ag@Au) bioconjugates and anti‐E. coli modified PS‐microwells were designed in a sandwich‐type format in order to obtain higher sensitivity and selectivity. Ag@Au bimetallic nanoparticles were synthesized by co‐reduction method. The core‐shell formation was analyzed by using UV‐Vis spectroscopy and transmission electron microscopy. Biotin labeled anti‐E. coli antibodies were coupled with Ag@Au nanoparticles to form bioconjugates. The electrochemical immunosensor was prepared by immobilizing anti‐E. coli on polystyrene (PS)‐microwells via chemical bonding. These modified microwells were identified with X‐ray photoelectron spectroscopy and surface enhanced Raman spectroscopy. E. coli was sandwiched between Ag@Au bioconjugates and anti‐E. coli on PS‐microwells at different concentrations. The relationship between the E. coli concentration and stripping current of gold ions (Au3+) were investigated by square wave anodic stripping voltammetry at pencil graphite electrode. The proposed method can provide some advantages such as lower detection limit and shorter detection time. The electrochemical response for the immunosensor was linear with the concentration of the E. coli in the range of 101 and 105 cfu/mL with a limit of detection 3 cfu/mL. The procedure maintains good sensitivity and repeatability and also offers utility in the fields of environmental monitoring and clinical diagnosis.  相似文献   

15.
Microcrystalline cellulose (MCC) was modified with pyridone derivatives such as pyridone diester (PDE) and pyridone diacid (PDA) by using succinic acid anhydride as a linker. The modified MCCs were characterized by the fourier transform infrared spectroscopy, scanning electron microscopy, thermal gravimetric analysis, elemental analysis and solid state 13C NMR. The adsorption capacities of the modified MCCs to cationic dyes were examined by using methylene blue (MB) as a model dye. It was found that the kinetic adsorption data followed the pseudo-second-order kinetic model, and the adsorption equilibriums were reached less than 10 min. The isothermal adsorption data were fitted with the Langmuir isotherm model very well, from which the maximum adsorption capacities of the MCCs modified with PDE and PDA were determined to be 101.01 and 142.86 mg/g, respectively. Further investigation showed that the modified MCCs were pH-dependent for adsorption of MB in aqueous solutions. The modified MCCs could be used for removal of MB from an aqueous solution at pH 8, and reused by regeneration in an acidic solution. It was tested that the modified MCCs had a high reusability for removal of MB from aqueous solutions, and still maintained high adsorption capacities even after multiple cycles of desorption–adsorption processes. Hence, the MCCs modified with PDE and PDA could be an effective and efficient approach to removal of cationic dyes from aqueous solutions.  相似文献   

16.
《中国化学快报》2023,34(8):108102
The threat to public health from bacterial infections has led to an urgent need to develop simpler, faster and more reliable bacterial detection methods. In this work, we developed a universal dual-recognition based sandwich fluorescence resonance energy transfer (FRET) sensor by using specific aptamer-modified quantum dots (Aptamer-QDs) as energy donor and lectin concanavalin A (Con A) modified gold nanoparticles (Con A-AuNPs) as energy acceptor to achieve rapid and sensitive detection of Escherichia coli (E. coli) within 0.5 h. In the presence of the target E. coli, the energy donor of Aptamer-QDs and acceptor of Con A-AuNPs were close to each other, causing changes of FRET signals. Based on the constructed FRET sensor, a linear detection range of from 102 cfu/mL to 2 × 108 cfu/mL with the detection limit of 45 cfu/mL for E. coli was achieved. Furthermore, the FRET sensor was applied to detect E. coli in the milk and orange juice with the detection limit of 300 cfu/mL and 200 cfu/mL, respectively and recovery rate from 83.1% to 112.5%. The strategy holds great promise in pathogenic bacteria detection due to its rapid and sensitivity.  相似文献   

17.
In this work, CE‐LIF was employed to investigate the amino acid metabolites produced by Escherichia coli (E. coli) in microbial fuel cell (MFC). Two peptides, l ‐carnosine and l ‐alanyl‐glycine, together with six amino acids, cystine, alanine, lysine, methionine, tyrosine, arginine were separated and detected in advance by a CE‐LIF system coupled with a homemade spontaneous injection device. The injection device was devised to alleviate the effect of electrical discrimination for analytes during sample injection. All analytes could be completely separated within 8 min with detection limits of 20–300 nmol/L. Then this method was applied to analyze the substrate solution containing amino acid metabolites produced by E. coli. l ‐carnosine, l ‐alanyl‐glycine, and cystine were used as the carbon, nitrogen, and sulfur source for the E. coli culture in the MFC to investigate the amino acid metabolites during metabolism. Two MFCs were used to compare the activity of metabolism of the bacteria. In the sample collected at the running time 200 h of MFC, the amino acid methionine was discovered as the metabolite with the concentrations 23.3 μg/L.  相似文献   

18.
《Analytical letters》2012,45(17):2690-2704
A disposable immunosensor for the detection of Escherichia coli O157:H7 based on a multiwalled carbon nanotube–sodium alginate nanocomposite film was constructed. The nanocomposite was placed on a screen-printed carbon electrode, and horseradish peroxidase-labeled antibodies were immobilized to E. coli O157:H7 on the modified electrode to construct the immunosensor. The modification procedure was characterized by atomic force microscopy and cyclic voltammetry. Under optimal conditions, the proposed immunosensor exhibited good electrochemical sensitivity to E. coli O157:H7 in a concentration range of 103–1010 cfu/mL, with a relatively low detection limit of 2.94 × 102 cfu/mL (S/N = 3). This immunosensor exhibited satisfactory specificity, reproducibility, stability, and accuracy, making it a potential alternative tool for early assessment of E. coli O157:H7.  相似文献   

19.
Effective bacteria detection and quantification are essential prerequisite for the prevention and treatment of infectious diseases. Herein, we report a method for the detection and quantification of Escherichia coli (E. coli).N-Methylimidazolium modified magnetic particles (MIm-MPs) are synthesized successfully and used as an efficient magnetic material for the isolation and concentration of E. coli. The factors including pH of binding buffer, concentration of elution buffer and elution time which may affect the capture and elution efficiencies are optimized. The linear correlation between bacteria concentration and peak area of polymerase chain reaction (PCR) product analyzed by capillary electrophoresis (CE) is determined. Rapid preconcentration of trace amount of E. coli (101 cfu mL−1) in large volume of aqueous sample (500 mL) is achieved, and the capture efficiency can reach 99%. The quantification of bacteria in large volume of spiked tap water and mineral water samples is realized. The recoveries for different concentrations of E. coli in tap and mineral water samples are in the range between 83% and 93%. The results demonstrate that this MIm-MPs-PCR-CE method can be applied to detect and quantify bacteria in real samples.  相似文献   

20.
Functionalisation of the sensing surface is a key factor in immunosensor fabrication as it allows target-selective capture and prevents nonspecific adsorption of undesired components. Gold immunofunctionalisation using self-assembled monolayers (SAM) has been widely exploited to this end for the detection of small targets. However, we recently demonstrated that this strategy fails when detecting whole bacteria cells (Baldrich et al., Anal Bioanal Chem 390:1557–1562, 2008). We now investigate different physisorption-based alternatives using E. coli as the target organism. Our results demonstrate that physisorption generates the appropriate substrate for the specific detection of bacteria on gold surfaces, providing detection limits down to 105 cells mL−1 in an ELISA-type colorimetric assay. Additionally, surface coverage is highly reproducible when assayed by impedance spectroscopy and the inter- and intra-assay coefficients of variation are below 10–15% in all cases. These surfaces were stable, retained functionality and did not suffer from significant biomolecule desorption after 10 days storage in PBS at 37 °C, hence confirming physisorption as a cheap, simple and efficient strategy for the detection of bacteria.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号