首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and efficient electrochemical method is utilized to functionalize aligned carbon nanotubes (ACNTs) by the electrochemical reduction of 4‐carboxyphenyl diazonium salt. Thus hemoglobin (Hb) molecules were covalently immobilized on the diazonium‐ACNTs surface via carbodiimide chemistry. Direct electrochemistry and bioelectrocatalytic activity of the immobilized Hb were then investigated by cyclic voltammetry (CV) and amperometry techniques. It is showed that the Hb film on the diazonium‐ACNTs electrode had well‐defined redox peaks with a formal potential (E°) at ?312 mV (vs. Ag/AgCl), and the Hb‐ACNTs electrode displayed good electrocatalytic activity to H2O2 reduction. Owing to the high Hb covering on the ACNTs surface (Γ*=2.7×10?9 mol cm?2), the catalytic current were significantly improved when compared to the current measured at an Hb‐tangled carbon nanotubes electrode. The Hb‐ACNTs electrode exhibited high sensitivity, long‐term stability and wide concentration range from 40 μM to 3 mM for the amperometric detection of H2O2. The heterogeneous reaction rate constant (ks) was 0.95±0.05 s?1 and the apparent Michaelis–Menten constant (K was 0.15 mM.  相似文献   

2.
血红蛋白在碳纳米管修饰碳糊电极上的直接电化学行为   总被引:6,自引:0,他引:6  
利用吸附法将血红蛋白(Hb)固定在碳纳米管修饰碳糊电极表面,制成稳定的固载Hb碳纳米管修饰电极,研究了Hb在碳纳米管修饰电极上的直接电化学行为.固载Hb的碳纳米管修饰电极在pH=7.0的PBS(磷酸盐缓冲溶液)中有一对相当可逆的循环伏安氧化还原峰,为Hb血红素辅基Fe(Ⅲ)/Fe(Ⅱ)电对的特征峰.式电位为-0.160 V(vs SCE),随扫描速度变化很小.电子转移数为1.021,近似为一个辅基发生电子转移.Hb在碳纳米管修饰电极表面的电子转移常数为0.0816 s-1,远大于亚甲蓝作媒介体时Hb的电子转移反应速率常数.应用于过氧化氢、三氯乙酸和硝基苯等的电催化还原,固定在碳纳米管修饰碳糊电极的血红蛋白表现出稳定且较高的催化活性.  相似文献   

3.
In this article we report on the fabrication of a carbon ionic liquid electrode (CILE) by using a room temperature ionic liquid of 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) as binder. It was further modified by single‐walled carbon nanotubes (SWCNTs) to get a SWCNTs modified CILE denoted as SWCNTs/CILE. The redox protein of hemoglobin (Hb) was further immobilized on the surface of SWCNTs/CILE with the help of Nafion film. UV‐vis and FT‐IR spectra indicated that the immobilized Hb retained its native conformation in the composite film. The direct electrochemistry of Hb on the SWCNTs/CILE was carefully studied in pH 7.0 phosphate buffer solution (PBS). Cyclic voltammetric results indicated that a pair of well‐defined and quasireversible voltammetric peaks of Hb heme Fe(III)/Fe(II) was obtained with the formal potential (E°') at ?0.306 V (vs. SCE). The electrochemical parameters such as the electron transfer coefficient (α), the electron transfer number (n) and the apparent heterogeneous electron transfer rate constant (ks) were calculated as 0.34, 0.989 and 0.538 s?1, respectively. The fabricated Hb modified electrode showed good electrocatalytic ability to the reduction of trichloroacetic acid (TCA) in the concentration range from 20.0 to 150.0 mmol/L with the detection limit of 10.0 mmol/L (3σ).  相似文献   

4.
A polymer film based on polymeric ionic liquid, which was poly(1‐vinyl‐3‐butylimidazolium chloride) (poly(ViBuIm+Cl?)for short), was firstly used as matrix to immobilize hemoglobin (Hb). FTIR and UV‐vis spectra demonstrated that the native structure of Hb was well preserved after entrapped into the polymer film. The Hb immobilized in the poly(ViBuIm+Cl?) film showed a fast direct electron transfer for the Hb‐FeIII/FeII redox couple. Based on the direct electron transfer of the immobilized Hb, polyvinyl alcohol (PVA)/Hb/poly(ViBuIm+Cl?)/GC electrode displayed good sensitivity and wide linear range for the detection of H2O2. The linear range of the PVA/Hb/poly(ViBuIm+Cl?)/GC electrode to H2O2 is from 3.5 to 224 μM with a limit of detection of 1.17 μM. Such an avenue, which integrated polymeric ionic liquid and redox protein via a simple method, may provide a novel and efficient platform for the fabrication of biosensors, biofuel cells and other bioelectrochemical devices.  相似文献   

5.
A cobalt nanoparticles-attached indium tin oxide(CoNPs/ITO) electrode was applied to the immobilization of hemoglobin(Hb) and an Hb modified CoNPs/ITO electrode(Hb/CoNPs/ITO) was prepared. The direct electron transfer of Hb was shown by the well-behaved voltammetric responses for Hb/CoNPs/ITO electrode and the effects of scan rate and pH value were observed. Based on the catalytic activity of Hb immobilized on the CoNPs/ITO electrode toward the reduction of H2O2, a mediator-free H2O2 sensor was developed. A linear relationship existed between the catalytic current and the H2O2 concentration in a range of 1.0―100.0 μmol/L with a detection limit (S/N=3) of 0.2 μmol/L.  相似文献   

6.
In this paper NiMoO4 nanorods were synthesized and used to accelerate the direct electron transfer of hemoglobin (Hb). By using an ionic liquid (IL) 1‐butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (CILE) as the basic electrode, NiMoO4 nanorods and Hb composite biomaterial was further cast on the surface of CILE and fixed by chitosan (CTS) to establish a modified electrode denoted as CTS/NiMoO4‐Hb/CILE. UV‐vis and FT‐IR spectroscopic results showed that Hb in the film retained its native structures without any conformational changes. Electrochemical behaviors of Hb entrapped in the film were carefully investigated by cyclic voltammetry with a pair of well‐defined and quasi‐reversible redox voltammetric peaks appearing in phosphate buffer solution (PBS, pH 3.0), which was attributed to the direct electrochemistry of the electroactive center of Hb heme Fe(III)/Fe(II). The results were ascribed to the specific characteristic of NiMoO4 nanorods, which accelerated the direct electron transfer rate of Hb with the underlying CILE. The electrochemical parameters of Hb in the composite film were further carefully calculated with the results of the electron transfer number (n) as 1.08, the charge transfer coefficient (α) as 0.39 and the electron‐transfer rate constant (ks) as 0.82 s?1. The Hb modified electrode showed good electrocatalytic ability toward the reduction of trichloroacetic acid (TCA) in the concentration range from 0.2 to 26.0 mmol/L with a detection limit of 0.072 mmol/L (3σ), and H2O2 in the concentration range from 0.1 to 426.0 µmol/L with a detection limit of 3.16×10?8 mol/L (3σ).  相似文献   

7.
The high electrically conductive carboxyl‐functionalized multiwalled carbon nanotubes (COOH‐MWCNTs) were used to combine with nonconducting polyimide (PI) to generate a PI/COOH‐MWCNTs membrane. PI served as a matrix to entrap COOH‐MWCNTs and hemoglobin (Hb). COOH‐MWCNTs can improve the conductivity of the composite. The direct electrochemistry measurement indicated that the PI/COOH‐MWCNTs composite enhanced the immobilization of Hb significantly. Besides, the Hb/PI/COOH‐MWCNTs/GCE biosensor possessed excellent electrocatalytic activity for the detection of nitrite. Therefore, PI is a good matrix for Hb immobilization and it has application in sensor construction. This work is promising in the development of sensitive biosensors based on PI/COOH‐MWCNTs composite film.  相似文献   

8.
Silver nanoparticles (narrowly dispersed in diameter) were electrodeposited on carbon ionic liquid electrode (CILE) surface using a two‐step potentiostatic method. Potentiostatic double pulse technique was used as a suitable and simple method for controlling the size and morphologies of silver nanoparticles electrodeposited on CILE. The obtained silver nanoparticles deposited on CILE surface showed excellent electrocatalytic activity (low overpotential of ?0.35 V vs. Ag/AgCl) towards reduction of hydrogen peroxide. A linear dynamic range of 2–200 μM with an experimental detection limit of 0.7 μM (S/N=3) and reproducibility of 4.1% (n=5) make the constructed sensor suitable for peroxide determination in aqueous solutions.  相似文献   

9.
《Electroanalysis》2006,18(11):1075-1080
The voltammetric behavior of uric acid (UA) has been studied at a multiwalled carbon nanotube‐ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium hexafluorophosphate, BMIMPF6) paste coated glassy carbon electrode (MWNTs‐BMIMPF6/GC). It is found that UA can effectively accumulate at this electrode and cause a sensitive anodic peak at about 0.49 V (vs. SCE) in pH 4.0 phosphate buffer solutions. Experimental parameters influencing the response of the electrode, such as solution pH and accumulation time, are optimized for uric acid determination. Under the optimum conditions, the anodic peak current is linear to UA concentration in the range of 1.0×10?8 M to 1.0×10?6 M and 2.0×10?6 M to 2.0×10?5 M. The detection limit is 5.0×10?9 M for 180 s accumulation on open circuit. The electrode can be regenerated by successively cycling in a blank solution for about 3 min and exhibits good reproducibility. A 1.0×10?6 M UA solution is measured for eight times using the same electrode regenerated after every determination, and the relative standard deviation (RSD) of the peak current is 3.2%. As for different electrodes fabricated by the same way the RSD (i.e., the electrode to electrode deviation) is 4.2%(n=9). This method has been applied to the determination of UA in human urine samples, and the recoveries are 99%–100.6%. In addition, comparison is made between MWNTs‐BMIMPF6/GC and MWNTs/GC. Results show that the MWNTs‐BMIMPF6/GC exhibits higher sensitivity, selectivity and ratio of peak current to background current.  相似文献   

10.
A new hemoglobin (Hb) and carbon nanotube (CNT) modified carbon paste electrode was fabricated by simply mixing the Hb, CNT with carbon powder and liquid paraffin homogeneously. To prevent the leakage of Hb from the electrode surface, a Nafion film was further applied on the surface of the Hb‐CNT composite paste electrode. The modified electrode was characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Direct electrochemistry of hemoglobin in this paste electrode was easily achieved and a pair of well‐defined quasi‐reversible redox peaks of a heme Fe(III)/Fe(II) couple appeared with a formal potential (E0′) of ?0.441 V (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical behaviors of Hb in the composite electrode were carefully studied. The fabricated modified bioelectrode showed good electrocatalytic ability for reduction of H2O2 and trichloroacetic acid (TCA), which shows potential applications in third generation biosensors.  相似文献   

11.
A biocompatible nanocomposite film was fabricated for hemoglobin (Hb) molecules immobilization. This film consists of multiwalled carbon nanotubes (MWNTs), 1‐pyrenebutanoic acid, succinimidyl ester (PASE), hemoglobin (Hb) and Au nanoparticles (AuNPs). Herein, PASE molecules physically adsorbed onto MWNTs, and its groups then covalently bond with Hb. AuNPs were then linked with Hb/PASE/MWNTs via electrostatic adsorption force. UV‐visible adsorption spectra, Fourier transform infrared spectra, scanning electron microscope and electrochemical impedance spectroscopy have characterized the film. Cyclic voltammetry (CV) scans showed that in the film Hb has well‐defined redox reaction, with the formal potential (E°) at about ?0.27 V (vs. Ag/AgCl). Herein, differential pulse voltammetry (DPV) was employed to electrochemically detect the Hb in the film with a detection limit of 9.3×10?8 M. The proposed method was also succeeded for Hb detection in clinical blood samples. Furthermore, the Hb in the film showed good electrocatalytic activities to the reduction of H2O2, TCA, NaNO2 and O2.  相似文献   

12.
A novel composite was fabricated through dispersing multiwalled carbon nanotubes (MWNTs) in gold nanoparticle (GPs) colloid stabilized by chitosan and ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium tetrafluoroborate, BMIMBF4). Transmission electron microscopy (TEM) experiment showed that the GPs highly dispersed on the MWNTs probably due to the electrostatic interaction among GPs, MWNTs and the imidazolium cation of BMIMBF4. X‐ray photoelectron spectroscopy (XPS) indicated that thus‐formed gold nanostructure was mediated by BMIMBF4. When glucose oxidase (GOD) was immobilized on the composite (MWNTs‐GPs) its ultraviolet‐visible absorption spectrum kept almost unchanged. The immobilized GOD coated glassy carbon electrode (GOD/MWNTs‐GPs/GC) exhibited a pair of well‐defined peaks in 0.10 M pH 7.0 phosphate buffer solution (PBS), with a formal potential of ?0.463 V (vs. SCE). The electrochemical process involved two‐electron transfer. The electron transfer coefficient was ca.0.56 and the electron transfer rate constant was 9.36 s?1. Furthermore, the immobilized GOD presented good catalytic activity to the oxidation of glucose in air‐saturated PBS. The Km and Im values were estimated to be 13.7 μM and 0.619 μA. The GOD/MWNTs‐GPs/GC electrode displayed good stability and reproducibility.  相似文献   

13.
A nanobiocompatible composite containing hemoglobin (Hb), ZnO nanoparticles (nano‐ZnO) and ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) was fabricated and further modified on the glassy carbon electrode (GCE). The electrochemical behaviours of Hb in the composite film were carefully studied and a pair of quasi‐reversible redox peaks appeared in pH 7.0 phosphate buffer solution, which was attributed to the electrode reaction of Hb heme Fe(III)/Fe(II) redox couple. The presences of nano‐ZnO and BMIMPF6 in the film can retain the bioactivity of Hb and greatly enhance the direct electron transfer of Hb. The immobilized Hb showed high stability and good electrocatalytic ability to the reduction of hydrogen peroxide and O2.  相似文献   

14.
将血红蛋白固定在用室温离子液体和魔芋葡甘聚糖(KGM)水凝胶修饰的玻碳电极上,其循环伏安扫描显示一对可逆的氧化还原电流峰,克式量电位(-0.38V,vs.SCE)随溶液pH值的增大而负移,呈良好的线性关系,斜率为51 mV/pH,表明在离子液体和KGM共同修饰的电极上包埋在魔芋葡甘聚糖水凝胶中的血红蛋白发生了直接可逆的电子传递反应,并伴随有一质子的迁移过程.此外,还考察了该血红蛋白修饰电极对O2还原反应的电催化性能.  相似文献   

15.
Platinum nanoparticles (Ptnano) decorated multiwalled carbon nanotubes (MWCNTs)–1‐octyl‐3‐methylimidazolium hexafluorophosphate ([omim][PF6]) composite material (MWCNTs‐Ptnano‐[omim][PF6]) was fabricated and characterized for the first time. In the presence of [omim][PF6], more Ptnano could deposit on MWCNTs. The average diameter of the deposited Ptnano was about 5 nm. The composite material film coated glassy carbon electrode (GCE) exhibited sensitive voltammetric response to theophylline (TP). Under the optimized conditions (i.e., preconcentration for 2 minutes on open circuit in 0.10 M pH 3.0 phosphate buffer), the anodic peak current of TP at about 1.1 V (vs. SCE) was linear to TP concentration over the range of 1.0×10?8–1.0×10?5 M. The detection limit was estimated to be 8.0×10?9 M. The modified electrode was successfully applied to the determination of TP in medicine tablet and green tea. In addition, the voltammetric responses of hypoxanthine (HX), xanthine (Xan) and uric acid (UA) on the MWCNTs‐Ptnano‐[omim][PF6]/GCE were also discussed.  相似文献   

16.
本文构建了一种新型多壁碳纳米管/壳聚糖/离子液体修饰电极.研究了支持电解质、酸度和扫描速度等因素对对苯二酚伏安响应的影响,获得了较优的实验条件.在0.1 mol/L pH=6.8磷酸盐缓冲溶液中测定对苯二酚,其氧化峰电流与对苯二酚浓度在8.0×10~(-7)~1.0×10~(-4) mol/L范围内呈良好的线性关系,检出限为7.9×10~(-8) mol/L.该电极对对苯二酚有较高的选择性,可直接测量对苯二酚,结果满意.  相似文献   

17.
纳米碳管电极上氧的电催化还原   总被引:5,自引:0,他引:5  
以聚四氟乙烯为粘结剂制成了多壁纳米碳管(MWNT)电极.采用恒电位阶跃法和循环伏安法研究了MWNT电极在碱性溶液中的电化学行为,并对碱性溶液中溶解氧在该电极上的电化学还原行为进行了研究.实验结果表明: MWNT电极具有比石墨电极更高的孔隙率和电化学表面积;MWNT电极上O2还原成的反应为准可逆过程;在5~50 mV•s-1的扫描速率范围内,阴极峰电流与扫描速度成线性关系,表明MWNT电极上O2还原成的反应受吸附控制;对碱性溶液中的氧还原反应, MWNT比石墨具有更高的催化活性.  相似文献   

18.
《Analytical letters》2012,45(8):1610-1621
Abstract

Cobalt hexacyanoferrate (CoHCF) film was formed on multiwalled carbon nanotubes (MWNTs) modified gold electrode by electrodeposition from 0.5 M KCl solution containing CoCl2 and K3Fe(CN)6. The electrochemical behavior and the electrocatalytic property of the modified electrode were investigated. Compared with CoHCF/gold electrode, the CoHCF/MWNTs/gold electrode exhibits greatly improved stability and enhanced electrocatalytic activity toward the oxidation of thiosulfate. A linear range from 5.0×10?5 to 6.5×10?3 M (r=0.9990) for thiosulfate detection at the CoHCF/MWNTs/gold electrode was obtained, with a detection limit of 2.0×10?5 M (S/N=3).  相似文献   

19.
A new hemoglobin (Hb) and room temperature ionic liquid modified carbon paste electrode was constructed by mixing Hb with 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) and graphite powder together. The Hb modified carbon ionic liquid electrode (Hb‐CILE) was further characterized by FT‐IR spectra, scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Hb in the carbon ionic liquid electrode remained its natural structure and showed good direct electrochemical behaviors. A pair of well‐defined quasireversible redox peaks appeared with the apparent standard potential (E′) as ?0.334 (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer number (n), the electron transfer coefficient (α) and the heterogeneous electron transfer kinetic constant (ks) of the electrode reaction were calculated with the results as 1.2, 0.465 and 0.434 s?1, respectively. The fabricated Hb‐CILE exhibited excellent electrocatalytic activity to the reduction of H2O2. The calibration range for H2O2 quantitation was between 8.0×10?6 mol/L and 2.8×10?4 mol/L with the linear regression equation as Iss (μA)=0.12 C (μmol/L)+0.73 (n=18, γ=0.997) and the detection limit as 1.0×10?6 mol/L (3σ). The apparent Michaelis–Menten constant (KMapp) of Hb in the modified electrode was estimated to be 1.103 mmol/L. The surface of this electrochemical sensor can be renewed by a simple polishing step and showed good reproducibility.  相似文献   

20.
碳糊电极上无机膜固载血红蛋白的直接电化学   总被引:12,自引:0,他引:12  
报道了用硅溶胶-凝胶(Sol-gel)膜将血红蛋白(Hb)固载于碳糊电极上的直接电化学行为.研究结果表明,Hb-Sol-gel修饰的碳糊电极在pH=7.0的缓冲溶液中于-0.275V(vs.Ag/AgCl)处有一对可逆的循环伏安氧化-还原峰,为Hb血红素辅基Fe(Ⅲ)/Fe(Ⅱ)电对的特征峰.HbFe(Ⅲ)/Fe(Ⅱ)电对的式量电位在pH5.0~11.0范围内与溶液pH值呈线性关系,表明Hb的电化学还原很可能是一个质子伴随着一个电子的电极过程.FTIR光谱证实,Sol-gel膜对Hb的固载没有破坏其天然结构.Hb-Sol-gel修饰的碳糊电极能够催化还原H2O2,可望将其用于制作第三代生物传感器.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏