首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A biosensor system for simultaneous determination of creatinine and urea in blood serum and dialysate samples was developed. It consisted of creatinine and urea biosensors based on a potentiometric transducers with two identical pH‐sensitive field‐effect transistors. In creatinine biosensor, creatinine deiminase immobilized via photopolymerization in PVA/SbQ polymer on one transistor served as a biorecognition element, while bovine serum albumin in PVA/SbQ polymer placed on the second transistor was used for reference. The urea biosensor was created in the same way but recombinant urease was used instead of creatinine deiminase. The linear ranges of creatinine and urea measurement were 0.02–2 mM and 0.5–15 mM, correspondingly, which allowed simultaneous determination of the metabolites. Response time of the biosensor system was 2–3 min; RSD of responses did not exceeded 5 %. The biosensors demonstrated absence of non‐selective response towards components of blood dialysate and serum. Urea and creatinine concentrations were determined in 20 samples of blood dialysate and serum. The results correlated well with traditional methods of analysis. Creatinine and urea biosensors were stable during five months of storage (during this time the responses decreased by about 10 %). The proposed biosensor system can be effectively used for analysis of serum samples and for hemodialysis control.  相似文献   

2.
Enzymatic amperometric procedures for measurement of Hg (II), based on the inhibitive action of this metal on urease enzyme activity, were developed. Screen-printed carbon electrodes (SPCEs) and gold nanoparticles modified screen-printed carbon electrodes (AuNPs/SPCEs) were used as supports for the cross-linking inmobilization of the enzyme urease. The amperometric response of urea was affected by the presence of Hg (II) ions which caused a decreasing in the current intensity. The optimum working conditions were found using experimental design methodology. Under these conditions, repeatability and reproducibility for both types of biosensors were determined, reaching values below 6% in terms of residual standard deviation. The detection limit obtained for Hg (II) was 4.2 × 10?6 M for urease/SPCE biosensor and 5.6 × 10?8 M for urease/AuNPs/SPCE biosensor. Analysis of the possible effect of the presence of foreign ions in the solution was performed. The method was applied to determine levels of Hg (II) in spiked human plasma samples.  相似文献   

3.
Nickel oxide nanoparticle (NiO?NP) and polypyrrole (PPy) composite were deposited on a Pt electrode for fabrication of a urea biosensor. To develop the sensor, a thin film of PPy?NiO composite was deposited on a Pt substrate that serves as a matrix for the immobilization of enzyme. Urease was immobilized on the surface of Pt/PPy?NiO by a physical adsorption. The response of the fabricated electrode (Pt/PPy?NiO/Urs) towards urea was analyzed by chronoamperometry and cyclic voltammetry (CV) techniques. Electrochemical response of the bio‐electrode was significantly enhanced. This is due to electron transfer between Ni2+ and Ni3+ as the electro‐catalytic group and the reaction between polypyrrole and the urease‐liberated ammonium. The fabricated electrode showed reliable and demonstrated perfectly linear response (0.7–26.7 mM of urea concentration, R2= 0.993), with high sensitivity (0.153 mA mM?1 cm?2), low detection of limit (1.6 μM), long stability (10 weeks), and low response time (~5 s). The developed biosensor was highly selective and obtained data were repeatable and reproduced using PPy‐NiO composite loaded with immobilized urease as urea biosensors.  相似文献   

4.
The urease enzyme of Helicobacter pylori was isolated from biopsy sample obtained from antrum big curvature cell extracts. A new urea biosensor was prepared by immobilizing urease enzyme isolated from Helicobacter pylori on poly(vinylchloride) (PVC) ammonium membrane electrode by using nonactine as an ammonium ionophore. The effect of pH, buffer concentration, and temperature for the biosensor prepared with urease from H. pylori were obtained as 6.0, 5 mM, and 25 °C, respectively. We also investigated urease concentration, stirring rate, and enzyme immobilization procedures in response to urea of the enzyme electrode. The linear working range of the biosensor extends from 1 × 10(-5) to 1 × 10(-2) M and they showed an apparent Nernstian response within this range. Urea enzyme electrodes prepared with urease enzymes obtained from H. pylori and Jack bean based on PVC membrane ammonium-selective electrode showed very good analytical parameters: high sensitivity, dynamic stability over 2 months with less decrease of sensitivity, response time 1-2 min. The analytical characteristics were investigated and were compared those of the urea biosensor prepared with urease enzyme isolated from Jack bean prepared at the same conditions. It was observed that rapid determinations of human serum urea amounts were also made possible with both biosensors.  相似文献   

5.
An optical biosensor for urea based on urease enzyme immobilised on functionalised calcium carbonate nanoparticles (CaCO3-NPs) was successfully developed in this study. CaCO3-NPs were synthesised from discarded cockle shells via a simple and eco-friendly approach, followed by surface functionalisation with succinimide ester groups. The fabricated biosensor is comprised of two layers. The first (bottom layer) contained functionalised NPs covalently immobilised to urease, and the second (uppermost layer) was alginate hydrogel physically immobilised to the pH indicator phenolphthalein. The biosensor provided a colorimetric indication of increasing urea concentrations by changing from colourless to pink. Quantitative urea analysis was performed by measuring the reflectance intensity of the colour change at a wavelength of 633.16 nm. The determination of urea concentration using this biosensor yielded a linear response range of 30–1000 mM (R2 = 0.9901) with a detection limit of 17.74 mM at pH 7.5. The relative standard deviation of reproducibility was 1.14%, with no signs of interference by major cations, such as K+, Na+, NH?+, and Mg2+. The fabricated biosensor showed no significant difference with the standard method for the determination of urea in urine samples.  相似文献   

6.
A new approach was developed for urea determination where a thin film of silicalite and zeolite Beta deposited onto gold electrodes of a conductometric biosensor was used to immobilize the enzyme. Biosensor responses, operational and storage stabilities were compared with results obtained from the standard membrane methods for the same measurements. For this purpose, different surface modification techniques, which are simply named as Zeolite Membrane Transducers (ZMTs) and Zeolite Coated Transducers (ZCTs) were compared with Standard Membrane Transducers (SMTs). Silicalite and zeolite Beta with Si/Al ratios 40, 50 and 60 were used to modify the conductometric electrodes and to study the biosensor responses as a function of changing zeolitic parameters. During the measurements using ZCT electrodes, there was no need for any cross-linker to immobilize urease, which allowed the direct evaluation of the effect of changing Si/Al ratio for the same type of zeolite on the biosensor responses for the first time. It was seen that silicalite and zeolite Beta added electrodes in all cases lead to increased responses with respect to SMTs. The responses obtained from ZCTs were always higher than ZMTs as well. The responses obtained from zeolite Beta modified ZMTs and ZCTs increased as a function of increasing Si/Al ratio, which might be due to the increased hydrophobicity and/or the acid strength of the medium.  相似文献   

7.
Magalhães JM  Machado AA 《Talanta》1998,47(1):183-191
Potentiometric biosensors based on urease (E.C. 3.5.1.5.) immobilized on chitosan membranes coupled to all-solid-state nonactin ammonium ion selective electrodes are described. The enzyme was immobilized on the chitosan membranes by four procedures: (A) adsorption; (B) adsorption followed by reticulation with dilute aqueous glutaraldehyde solution; (C) activation with glutaraldehyde followed by contact with the enzyme solution; and (D) activation with glutaraldehyde, contact with the enzyme solution and reduction of the Schiff base with sodium borohydride. The response characteristics of the biosensors obtained with these enzymatic membranes were determined and compared. The biosensor with best response characteristics, obtained by procedure (B), showed the following characteristics of response to urea: (i) linearity in the 10(-4) to 10(-2) M range; (ii) slope of up to 56 mV per decade; (iii) response time between 30 s and 2 min; and (iv) lifetime of 2 months. This biosensor was tested in the determination of urea in blood serum samples.  相似文献   

8.
《Analytical letters》2012,45(6):997-1011
ABSTRACT

An optical urea biosensor was developed by immobilizing an urease enzyme layer on a thin ammonium-selective polymer membrane. The ammonium optical membrane utilized dichlorofluorescein octadecyl ester (DCFOE) as anionic chromophore and nonactin as neutral ionophore. The urease layer was coated on the top of the ammonium layer by gelatin entrapment combined with glutaradehyde cross-linking. Hydrolysis of urea catalyzed by urease produced ammonium ion, which was extracted into the-polymer film to form complexes with nonactin. A proton was released which resulted in a color change of the optical membrane due to charge neutrality principle. The biosensor  相似文献   

9.
In this article, a mathematical model was developed to describe and optimize the configuration of the urea biosensor. The biosensor is based on interdigitated gold microelectrodes modified with a urease enzyme membrane. The model presented here focuses on the enzymatic reaction and/or diffusion phenomena that occur in the enzyme membrane and in the diffusion layer. Numerical resolution of differential equations was performed using the finite difference technique. The mathematical model was validated using experimental biosensor data. The responses of the biosensor to various conditions were simulated to guide experiments, improve analytical performance, and reduce development costs.  相似文献   

10.
Different modifications of the zeolites Na+‐Beta and LTA were applied for improving the working characteristics of a urea biosensor. The bioselective membrane of the biosensor was based on urease and different zeolites co‐immobilized with bovine serum albumin on the surface of a pH‐FET. It was shown that the biosensors modified with the zeolites H+‐Beta30 and H+‐Beta50 are characterized by increased sensitivity to urea. The influence of the zeolite concentration on the sensitivity of the biosensors was studied. The optimal concentration of the zeolites H+‐Beta30 and H+‐Beta50 in the bioselective membrane was 15 %. Different variants of co‐immobilization of urease and zeolite H+‐Beta30 were studied and the optimal method was selected. Thus, a general conclusion is that the urea biosensor sensitivity can be improved using zeolite H+‐Beta30 for urease immobilization in the bioselective membrane.  相似文献   

11.
A simple, selective and stable biosensor with the enzymatic reactor based on choline oxidase (ChOx) was developed and applied for the determination of choline (Ch) in flow injection analysis with amperometric detection. The enzyme ChOx was covalently immobilized with glutaraldehyde to mesoporous silica powder (SBA‐15) previously covered by NH2‐groups. This powder was found as an optimal filling of the reactor. The detection of Ch is based on amperometric monitoring of consumed oxygen during the enzymatic reaction, which is directly proportional to Ch concentration. Two arrangements of an electrolytic cell in FIA, namely wall‐jet cell with working silver solid amalgam electrode covered by mercury film and flow‐through cell with tubular detector of polished silver solid amalgam were compared. The experimental parameters affecting the sensitivity and stability of the biosensor (i. e. pH of the carrier solution, volume of reactor, amount of the immobilized enzyme, the detection potential, flow rate, etc.) were optimized. Under the optimized conditions, the limit of detection was found to be 9.0×10?6 mol L?1. The Michaelis‐Menten constant for covalently immobilized ChOx on SBA‐15 was calculated. The proposed amperometric biosensor with the developed ChOx‐based reactor exhibits good repeatability, reproducibility, long‐term stability, and reusability. Its efficiency has been confirmed by the successful application for the determination of Ch in two commercial pharmaceuticals.  相似文献   

12.
Prussian blue (PB) is an electrochromic material, which can be used as a signal transducer in the formation of optical urea biosensors. The previous researches in electrochromic properties of PB demonstrated the optical PB response to ammonium ions, which occurs when ammonium ions are interacting with PB layer at a constant 0.2 V vs Ag|AgCl|KClsat potential. In this work PB optical dependence on ammonium ions concentration was applied in the formation of electrochromic urea biosensor. Biosensor was formed by modifying the optically transparent indium tin oxide (ITO) coated glass electrode (glass/ITO) with Prussian blue layer and immobilizing urease (glass/ITO/PB‐urease). Calibration curve showed the linear dependency (R2=0.995) between the change of maximal absorbance (ΔA) and urea concentration in concentration range varying from 3 mM to 30 mM. The highest sensitivity (4 ΔA M?1) of glass/ITO/PB‐urease biosensor is in the concentration range from 7 mM to 30 mM. It was determined that working principle of the glass/ITO/PB‐urease biosensor is not related to pH changes occurring during enzymatic hydrolysis of urea.  相似文献   

13.
A urease optical biosensor for the determination of heavy metals based on sol-gel immobilization technique was developed. A fluorescent dye, FITC-dextran, was encapsulated and parameters including optical properties of the probe, relative enzyme activity, initial pH value and the buffer concentration for substrate preparation were investigated. In sol-gel immobilization, 1 mM Tris-HCl at pH 7.1 provided a sufficient buffer capacity for metal ion analysis as well as the enzyme activity maintenance. Also, two analytical procedures, incubated and un-incubated systems, were compared to understand the sensitivity and applicability to heavy metal analysis. The developed optical biosensor showed high reproducibility and the relative standard deviation (R.S.D.) of 5.1% (n=10) was obtained. Also, eight measurements can be completed automatically within 36 min. The biosensor has high sensitivity to Cu(II) and Cd(II) and an analytical range of 10-230 μM with a detection limit of 10 μM was achieved. Moreover, biological and environmental samples were examined to evaluate the applicability of the developed biosensor. A 19-82% of inhibition was observed when 20-45 μM metal ions were amended into tested samples, revealing that the developed system has the potential for the determination of heavy metals in real samples.  相似文献   

14.
The present article describes a miniaturized potentiometric urea lipid film based biosensor on graphene nanosheets. Structural characterization of graphene nanosheets for miniaturization of potentiometric urea lipid film based biosensors have been studied through atomic force microscopy (AFM) and transmission electron microscopy (TEM) measurements. UV‐Vis and Fourrier transform IR (FTIR) spectroscopy have been utilized to study the pre‐ and postconjugated surfaces of graphene nanosheets. The presented potentiometric urea biosensor exhibits good reproducibility, reusability, selectivity, rapid response times (~4 s), long shelf life and high sensitivity of ca. 70 mV/decade over the urea logarithmic concentration range from 1×10?6 M to 1×10?3 M.  相似文献   

15.
Different techniques have been used (physical adsorption, physically entrapped sandwich and microencapsulation) for the immobilization of urease enzyme in tetramethylorthosilicate (TMOS) derived sol-gel matrix on the sensing surface of glass-pH-electrode. No significant leaching of enzyme occurs from the microencapsulated and physically entrapped enzyme sandwich films. Potentiometric techniques have been used for the estimation of urea concentration in each instance. Various parameters of biosensor performance have been studied which indicates that microencapsulation technique is a better method of enzyme immobilization in sol-gel films derived from TMOS. The advantage of microencapsulated biosensor over others include higher sensitivity (dpH/dp(C) = 2.4), lower detection limit of 52 μg mL−1, larger linear range (0.01-30 mM) of urea determination and reasonably long-term stability of about 25 days with 80% response signal.  相似文献   

16.
A biosensor for the determination of urea in human serum was fabricated using a combination of inkjet printed polyaniline nanoparticles and inkjet printed urease enzyme deposited sequentially onto screen-printed carbon paste electrodes. Chronocoulometry was used to measure the decomposition of urea via the doping of ammonium at the polyaniline-modified electrode surface at -0.3 V vs. Ag/AgCl. Ammonium could be measured in the range from 0.1 to 100 mM. Urea could be measured by the sensor in the range of 2-12 mM (r(2)=0.98). The enzyme biosensor was correlated against a spectrophotometric assay for urea in 15 normal human serum samples which yielded a correlation coefficient of 0.85. Bland-Altman plots showed that in the range of 5.8-6.6 mM urea, the developed sensor had an average positive experimental bias of 0.12 mM (<2% RSD) over the reference method.  相似文献   

17.
A new enzyme coated electrode for the determination of urea in blood samples has been developed. It is based on the encapsulation of urease enzyme in the porous silicate matrix by the sol-gel technique on a glass electrode for the purpose of sensing urea in blood samples. Various parameters like the effect of pH, selection of a suitable buffer of appropriate concentration and interference of common substances in blood samples have been evaluated to optimize the conditions for the determination of urea. The electrode can be used for the determination of urea in the concentration range 0.03-30.0 mM in a solution. The detection limit of the present enzyme-coated electrode is found to be 52 μg/ml of urea. The relative standard deviation for the electrode-to-electrode reproducibility is found to be 2.4% for the determination of 0.1 mM of urea (six replicate electrodes). Sol-gel matrix containing immobilized enzyme was stable for about 25 days at ∼4 °C with 80% urease activity. Urea content in various clinical blood samples has been estimated using this electrode and the results are found to be in good agreement with the standard clinical methods as reported in the literature.  相似文献   

18.
Here the feasibility of layers based on the conducting polymer polyaniline (PANI) as component of glucose biosensors using glucose oxidase (GOx) as enzyme and [Os(bpy)2(4‐aminomethylpyridine)Cl]PF6 (OsCmplx) as electrochemical mediator, is evaluated. Particularly, PANI was employed to obtain a nanostructured macroporous material (m‐PANI) around polystyrene nanoparticles taken as template and the mediator was co‐immobilized during the polymerizing procedure. The GOx biosensor based on OsCmplx modified m‐PANI provides a linear response to glucose concentration in the range 5 up to 65 mM with a sensitivity of 3.54 µA/mM/cm2 (on a projected geometric area=0.07 cm2), an LOD of 0.8 mM and a good precision (%RSD≤7, n=5); the biosensor is stable showing a decrease of 10% to the value of the sensitivity after 15 days of use and of about 50% after 40 days.  相似文献   

19.
A boron‐doped diamond (BDD) electrode coupled to flow injection analysis (FIA) was firstly developed for determination of N‐acetyl‐L ‐cysteine (NAC) in drug formulations. The effects of experimental parameters including pH, applied potential and scan rate on the response were investigated. FIA amperometry was applied as an automatic method for the quantitative detection of trace amounts of NAC. A wide linear range of 0.5–50 µmol/L and a low detection limit of 10 nmol/L were obtained. The results of amperometric determinations show a very good reproducibility, and the RSD for the measurement based on 10 measurements was <3.7 % and <4.1 % for intra‐ and inter‐day, respectively. The benefits of the proposed method are fast, simple, sensitive and no requirement of complicated operational steps.  相似文献   

20.
《Electroanalysis》2006,18(16):1572-1577
An amperometric tyrosinase biosensor was developed via a simple and effective immobilization method using the self‐assembled monolayers (SAMs) technique. The organic monolayer film was first formed by the spontaneous assembly of thiolor sulfur compound (1,6‐hexanedithiol, HDT) from solution onto gold electrode. When these thiol‐rich surfaces were exposed to Au colloid, the sulfurs form strong bonds to gold nanoparticles, anchoring the clusters to the electrode substrate. After the assembly of gold nanoparticles layer, a new nano‐Au surface was obtained. Thus, the tyrosinase could be immobilized onto the electrode. The tyrosinase retained its activity well in such an immobilization matrix. The various experimental variables for the enzyme electrode were optimized. The resulting biosensor can reach 95% of steady‐state current within 10 s, and the trend in the sensitivity of different phenolic compounds was as follows: catechol>phenol>p‐cresol. In addition, the apparent Michaelis–Menten constant (K and the stability of the enzyme electrode were estimated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏