《Electroanalysis》2017,29(2):609-615
In this work a method for sensitive anodic stripping voltammetric determination of Pb(II) ions using a poly xylenol orange film modified electrode (PXOFME) has been proposed. Poly xylenol orange film (PXOF) was formed on a paraffin impegrenated graphite electrode (PIGE) using electro polymerization method by scanning the potential between −0.5 V to 1.3 V, at a scan rate of 50 mV/s for 30 segments in 0.1 M phosphate buffer solution (PBS) of pH 7. The PXOFME was characterized by scanning electron microscopy (SEM), ATR‐IR spectroscopy, cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The modified electrode has been used to develop a sensitive method for the determination of Pb(II) ions by anodic stripping voltmmetry (ASV). The PXOFME was used to preconcentrate Pb(II) ions through complexation, the complexed metal ions were reduced electrochemically and then stripped anodically from the surface of the electrode. A linear range of 5 μg/L to 413 μg/L with a limit of detection (S/N=3) of 1.6 μg/L was observed for the determination of Pb(II) ions. The method was applied to lead determination in sea water and tap water samples and the results were found to be satisfactory.  相似文献   

2.
A simple electroanalytical method for Cd(II) and Pb(II) detection based on differential pulse anodic stripping voltammetry (DPSV) with in situ prepared antimony-modified glassy carbon rotating disk electrode (in situ Sb-GC-RDE) was developed. The electrochemical detection was performed in a microdroplet (50 μL) of 0.01 M hydrochloric acid that is placed between the electrode surface (top) and a Parafilm®-covered glass slide to maintain a hydrophobic surface (bottom). This method includes a preconcentration process using a membrane filter (MF). The target metal ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a chelating agent, which was accumulated on the MF via filtration. The RDE microdroplet anodic stripping voltammetry was suitable for the elution and determination of metal ions accumulated on the MF. The in situ preparation of antimony-modified electrode allows the use of common GC electrode with high performance. The detection limits for Cd(II) and Pb(II) were 1.4 and 1.1 μg/L, respectively. The proposed method was successfully used in natural water samples for the simultaneous determination of Cd(II) and Pb(II).  相似文献   

3.
《Analytical letters》2012,45(7):1267-1278
Abstract

In this work, a new method for the simultaneous determination of Pb(II) and Cd(II) on the multiwalled carbon nanotubes (MWNT)-Nafion-bismuth modified glassy carbon electrode (GCE) using square-wave anodic stripping voltammetry has been studied. Scanning electron microscopy was used to investigate the characteristics of the MWNT-Nafion-bismuth modified GCE. Well-defined sharp stripping peaks were observed in the determination of Pb(II) and Cd(II) simultaneously on this electrode. Under optimized conditions, the lowest detectable concentrations were 50 ng/l for Pb(II) and 80 ng/l for Cd(II) under a 10 min preconcentration. The attractive performances of MWNT-Nafion-bismuth modified GCE demonstrated its application for a simple, rapid, and harmless determination of trace heavy metals.  相似文献   

4.
The voltammetric characteristics of lead(II) benzoylacetonate in chloroform at the mercury electrode are investigated. The conditions for nearly reversible reduction of lead(II) were optimized. Anodic stripping voltammetry for the determination of trace-lead was developed using differential pulse technique to strip amalgamed lead from hanging mercury drop electrode. The experimental conditions, such as scanning rate of electrode potential and deposition time of lead were optimized. The calibration graph was linear over concentration range 5x10(-8)-10(-6) M of lead(II). The detection limit was 2.5x10(-9) and the relative standard deviation for the determination of 4x10(-7) M Pb(II) was 2%. Preceded by decomposition of organolead compounds with concentrated nitric acid, then ashing at 300 degrees C and a solvent extraction of Pb(II) benzoylacetonate in chloroform, the suitability of the proposed method for the determination of lead in free-lead gasoline and gas oil was demonstrated as a typical example of application.  相似文献   

5.
In this work, simultaneous determination of Cu(II), Pb(II) and Zn(II) ions at low concentration levels (ppb) by square wave anodic stripping voltammetry on a Bi(III) film electrode plated in situ at a glassy carbon electrode (GCE) is described. A chemometric approach was used to overcome the overlapping peaks of Cu(II) and Bi(III), the competition of the electrodeposited Cu and Bi for the surface of the GCE and the formation of Cu‐Zn intermetallic compounds. The construction of the multivariate calibration models, based on partial least squares regression, allowed the simultaneous determination of Cu (in the concentration range 8.0 to 20.1 ppb), Pb (2.0 to 30.0 ppb) and Zn (29.7 to 90.4 ppb) with most of the prediction errors obtained in the external validation set for the three models lower than 16, 11 and 26 %, respectively. Finally, this method was used for the determination of these trace metal ions in surface river water samples with satisfactory results [errors below 10, 5 and 32 % for Cu(II), Pb(II) and Zn(II), respectively].  相似文献   

6.
A hexagonal mesoporous silica (HMS) functionalized with a 5-mercapto-1-methyltetrazole derivative was employed to prepare a chemically modified carbon paste electrode for Pb(II) detection in aqueous solution by square wave adsorptive stripping voltammetry. The optimal operating conditions were 5 min preconcentration time at pH 6.5, and 120 s electrolysis time in 0.2 mol L?1 HCl. Under these conditions, the voltammetric signal increased linearly with the preconcentration time in the range 1 to 10 min and with the Pb(II) concentration in the range 1 to 100?µg L?1. The electrode was reproducible and sensitive. Simultaneous determination of Pb, Cd and Cu was also carried out with the electrode. The accuracy of the method was validated by analysing Pb(II) in tap water and groundwater samples.  相似文献   

7.
Bismuth film electrodes are widely used for determination of heavy metal ions in acidic solutions, while alkaline solutions are rarely employed. We have compared the deposition of Bi(III) and Pb(II) on a Nafion-coated glassy carbon electrode in alkaline and acidic solutions. The results indicate that both Bi(III) and Pb(II) can be deposited in either alkaline or acidic solution, but the quantity of Pb(II) deposited in alkaline solution is less than that in acidic solution. The modified electrode was used to determine heavy metal ions in both alkaline and acidic solutions, and the results of the method agree well with those of atomic absorption spectroscopy.  相似文献   

8.
以金纳米粒子修饰玻碳电极为工作电极, 采用超声-微分脉冲阳极溶出伏安法连续测定饮用水中痕量铅(II)和 铜(II). 通过原子力显微镜(AFM)对金纳米粒子的形貌和大小进行表征, 对超声波提高伏安检测信号的工作机理作了比较详细的探讨. 实验结果表明, 超声波-伏安法提高了方法的灵敏度, 与传统的微分脉冲伏安法相比, Pb(II)和Cu(II)的峰电流分别增大10倍和8倍. Pb(II)和Cu(II)离子在质量浓度10~250 µg•L-1和5~200 µg•L-1范围内成良好的线性关系, 相关系数分别为0.9943和0.9985. 在含有50 µg•L-1 Pb(II)和20 µg•L-1 Cu(II)的溶液中重复测定9次, 其相对标准偏差为3.5%和2.2%, Pb(II)和Cu(II)的检出限分别为0.3 ng•mL-1和0.1 ng•mL-1. 该方法成功应用于饮用水中痕量Pb(II)和Cu(II)的检测, 方法简便可靠, 具有实际应用意义.  相似文献   

9.
We report on a glassy carbon electrode (GCE) modified with a lead ionophore and multiwalled carbon nanotubes. It can be applied to square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) for 300?s in pH?4.5 acetate buffer containing 400?μg?L?1 of Bi(III). The ionophore-MWCNTs film on the GCE possesses strong and highly selective affinity for Pb(II) as confirmed by quartz crystal microbalance experiments. Under the optimum conditions, a linear response was observed for Pb(II) ion in the range from 0.3 to 50?μg?L?1. The limit of detection (at S/N?=?3) is 0.1?μg?L?1. The method was applied to the determination of Pb(II) in water samples with acceptable recovery.
Figure
A glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes is successfully applied to sensitive and selective square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) in pH?4.5 solutions containing 400?μg?L?1 of Bi(III).  相似文献   

10.
The preparation of Hg(II)-modified multi walled carbon nanotube (MWCNT) by reaction of oxidized MWCNT with aqueous HgCl2 was carried out. The Hg(II)-modified multi walled carbon nanotube (Hg(II)/MWCNT) dispersed in Nafion solution was used to coat the polished graphite electrode surface. The Hg(II)/MWCNT modified graphite electrode was held at a cathodic potential (−1.0 V) to reduce the coordinated Hg(II) to Hg forming nanodroplets of Hg. The modified electrode was characterized by FESEM/EDAX which provided useful insights on the morphology of the electrode. The SEM images showed droplets of Hg in the size of around 260 nm uniformly distributed on the MWCNT. Differential pulse anodic stripping voltammetry (DPASV) and electrochemical impedance spectroscopy were used to study the Hg(II) binding with MWCNT. Differential pulse anodic stripping voltammetry of ppb levels of cadmium and lead using the modified electrode yielded well-defined peaks with low background current under a short deposition time. Detection limit of 0.94 and 1.8 ng L−1 were obtained following a 3 min deposition for Pb(II) and Cd(II), respectively. Various experimental parameters were characterized and optimized. High reproducibility was observed from the RSD values for 20 repetitive measurements of Pb(II) and Cd(II) (1.7 and 1.9%, respectively). The determination of Pb(II) and Cd(II) in tap water and Pb(II) in human hair samples was carried out. The above method of fabrication of Hg(II)/MWCNT modified graphite electrode clearly suggests a safe route for preparing Hg immobilized electrode for stripping analysis.  相似文献   

11.
A flow coulometric electroanalytical system using a copper column electrode with a copper wire inserted into a Nafion tube was developed to determine Pb(II) content based on anodic stripping voltammetry. The electrolysis efficiency of 5 μM Pb(II) was evaluated to be 100.4±4.5 % (n=5) when the length of the copper wire and flow rate of the Pb(II) solution were 50 cm and 0.1 mL min−1, respectively. The amount of electricity due to the re-oxidation of Pb electrodeposited at the copper column electrode was proportional to the concentration of Pb(II) in the range between 0.1 to 100 μM, and the limit of detection for Pb(II) was 0.8 μM for a deposition time of 15 min. Interference from the presence of Cd(II) could be avoided and the selective determination of Pb(II) was successfully achieved by adjustment of the electrodeposition potential.  相似文献   

12.
A sensitive and selective method for the determination of lead(II) with a 1,4-bis(prop-2'-enyloxy)-9,10-anthraquinone (AQ) modified carbon paste electrode has been developed. The method is based on non-electrolytic preconcentration via complex formation with modifier, followed by an accumulation period with a negative potential (-1.5 V), and then by a proper anodic stripping. The analytical performance was evaluated with respect to the quantity of modifier in the paste, concentration of electrolyte solution, preconcentration time, lead(II) concentration, and other variables. A linear calibration graph was obtained in the concentration range 2.00x10(-9)-1.06x10(-5) M Pb(II) (n=21, r=0.9999) with 30 s preconcentration time. The detection limit was found to be 1x10(-9) M. For eight preconcentration/determination cycles, the differential pulse voltammetric response was reproduced with 5.0 and 3.7% relative standard deviations at 2.00x10(-8) and 2.00x10(-6) M Pb(II), respectively. Rapid and convenient renewal of electrode surface allows the use of a single modified electrode surface in multiple analytical determinations over several weeks. Many coexisting metal ions had little or no effect on the determination of lead(II). The developed method was applied to lead determination in waste waters.  相似文献   

13.
《Analytical letters》2012,45(11):2273-2284
Abstract

A novel voltammetric method—anodic—using a bismuth/poly(aniline) film electrode has been developed for simultaneous measurement of Pb(II) and Cd(II) at low µg L?1 concentration levels by stripping voltammetry. The results confirmed that the bismuth/poly(aniline) film electrode offered high‐quality stripping performance compared with the bismuth film electrode. Well‐defined sharp stripping peaks were observed for Pb(II) and Cd(II), along with an extremely low baseline. The detection limits of Pb(II) and Cd(II) are 1.03 µg L?1 and 1.48 µg L?1, respectively. The bismuth/poly (aniline) electrode has been applied to the determination of Pb(II) in tap water samples with satisfactory results.  相似文献   

14.
A simple flow injection analysis (FIA) system for residual chlorine in tap water has been developed by using a Pb(II) ion-selective electrode (ISE) detector. The method is based on a specific response of the Pb(II)-ISE to residual chlorine. The FIA system consists of a millivolt meter, a peristaltic pump, a Pb(II)-ISE detector and a recorder. A linear working curve between peak height and concentration of residual chlorine was obtained from 0.1 to 1 mg l(-1) for the developed FIA system. The relative standard deviation for repeated injections of a 0.2 mg l(-1) residual chlorine sample was 2%. The regression line and its correlation factor between the conventional o-tolidine colorimetric method and the present method were Y=0.75X+0.17 and 0.967, respectively, for this determination.  相似文献   

15.
The behavior of Pb(II) and Pb(IV) was studied by voltammetry in supporting electrolytes containing 0.1 M NaOH or 0.1 M NaOH + 0.1 M Na3Cit at a graphite and a mercury thin-film electrodes. The best conditions were found for the coulometric determination of Pb by the oxidation of Pb(0) to Pb(II) in the presence of 5- to 20-fold amounts of Bi(III) and Cu(II) within the range 0.2–2 mg Pb(II) with an error and a relative standard deviation of less than 0.5%. Along with the procedure proposed previously for the determination of Pb(II) and Pb(IV) present simultaneously using a platinum gauze electrode, this procedure was applied to the determination of Pb(II) and Pb(IV) in samples of high-Tc. Cu-Bi superconductors. For samples of high-Tc. Bi-Pb-A-Cu-0 superconductors (A = Ba or Sr-Ca) containing from 2 to 12% Pb(II), the relative standard deviation was less than 0.5%; for 0.6–7% Pb(IV), it was 1-0.2%.  相似文献   

16.
In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.  相似文献   

17.
A modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) and 3-(4-methoxybenzylideneamino)-2-thioxothiazolodin-4-one as a new synthesized Schiff base was constructed for the simultaneous determination of trace amounts of Hg(II) and Pb(II) by square wave anodic stripping voltammetry. The modified electrode showed an excellent selectivity and stability for Hg(II) and Pb(II) determinations and for accelerated electron transfer between the electrode and the analytes. The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as pH, deposition potential and deposition time were optimized for the purpose of determination of traces of metal ions at pH 3.0. Under optimal conditions the limits of detection, based on three times the background noise, were 9.0 × 10−4 and 6.0 × 10−4 μmol L−1 for Hg(II) and Pb(II) with a 90 s preconcentration, respectively. In addition, the modified electrode displayed a good reproducibility and selectivity, making it suitable for the simultaneous determination of Hg(II) and Pb(II) in real samples such as sea water, waste water, tobacco, marine and human teeth samples.  相似文献   

18.
A voltammetric method for the determination of Cu(II) and Pb(II) in gasoline using sample preparation as three-component solutions (gasoline:propan-1-ol:water, 25:60:15 v/v/v) is proposed. HNO(3) was employed as a supporting electrolyte and to allow the use of aqueous inorganic standards for calibration, even if the analyte species originally in gasoline is present as a metallo-organic form. A square-wave anodic sequential determination was used by measuring the stripping current of Cu(II) (at +104 mV) using a glassy carbon electrode (GCE) and, in a second run, measuring the Pb(II) stripping current (at -470 mV) using a bismuth-film deposited on the surface of the GCE. The method allowed the quantification of 1.7 x 10(-9) mol L(-1) of Cu and 1.4 x 10(-10) mol L(-1) of Pb employing a 1500-s accumulation time. Recovery tests using analyte spiked three-component solutions prepared with commercial gasoline samples enabled recoveries of Cu and Pb from 97 +/- 8 to 102 +/- 5%.  相似文献   

19.
We have developed a sensor for the square wave anodic stripping voltammetric determination of Pb(II). A glassy carbon electrode was modified with a thin film of an antimony/poly(p-aminobenzene sulfonic acid) composite in air-saturated aqueous solution of pH 2.0. Compared to a conventional antimony film electrode, the new one yields a larger stripping signal for Pb(II). The conditions of polymerization, the concentration of Sb(III), the pH value of the sample solution, the deposition potential and time, frequency, potential amplitude, and step increment potential were optimized. Under the optimum conditions, a linear response was observed for Pb(II) in the range of 0.5 to 150.0 μg?L?1. The detection limit for Pb(II) is 0.1 μg?L?1.
Figure
The surface of a glassy carbon electrode (GCE) was modified by electropolymerization of p-aminobenzene sulfonic acid (p-ABSA) and the modified electrode was then prepared by in situ depositing antimony and target metal on the poly(p-ABSA) coated glassy carbon electrode. The antimony/poly(p-ABSA) film electrode displays high electrochemical activity in giving a peak current that is proportional to the concentration of Pb(II) in a certain range.  相似文献   

20.
A composite of high-purity grade carbon powder and an epoxy resin is used to in situ obtain a bismuth-film electrode. The surface of the indicator electrode is renewed by cutting a thin surface layer before each determination. The in situ obtained Bi-film electrode is virtually no different from an Hg-film electrode in sensitivity, reproducibility, and the ability to separate signals from Tl, Cd, and Pb. The calibration graph is linear in the range of thallium concentrations from 0.01 to 1 mg/L (RSD varies from 4 to 2%). A significant excess of Pb(II), Sn(II), and Cd(II) does not interfere with the determination of thallium. A procedure for determining down to 5 × 10?6% thallium in lithium carbonate is developed.  相似文献   