首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A preconcentration and determination methodology for vanadium at trace levels in parenteral solutions was developed. Cloud point extraction was successfully employed for the preconcentration of vanadium prior to inductively coupled plasma atomic optical emission spectrometry (ICP-OES) coupled to a flow injection (FI) system. The vanadium was extracted as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol [V-(5-Br-PADAP)] complex, at pH 3.7 mediated by micelles of the nonionic surfactant polyoxyethylene (5.0) nonylphenol (PONPE 5.0). The extracted surfactant-rich phase (100 mul) was mixed with 100 mul of ethanol and this final volume injected into ICP-OES for the vanadium determination. Under these conditions, the 50 ml sample solution preconcentration allowed raising an enrichment factor of 250-fold; however, it was possible to obtain a theoretical enrichment factor of 500-fold. The lower limit of detection (LOD) obtained under the optimal conditions was 16 ng l(-1). The precision for 10 replicate determinations at the 2.0 mug l(-1) V level was 2.3% relative standard deviation (RSD), calculated with the peak heights. The calibration graph using the preconcentration system for vanadium was linear with a correlation coefficient of 0.9996 at levels near the detection limits up to at least 50 mug l(-1). The method was successfully applied to the determination of vanadium in parenteral solution samples.  相似文献   

2.
Tang AN  Ding GS  Yan XP 《Talanta》2005,67(5):942-946
Cloud point extraction was applied as a preconcentration step for electrothermal atomic absorption spectrometry (ETAAS) determination of As(III) in aqueous solutions. After complexation with ammonium pyrrolidinedithiocarbamate, the analyte was quantitatively extracted to the surfactant-rich phase in the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. 0.1 mol L−1 HNO3 in methanol was added to the surfactant-rich phase before ETAAS determination. The precision (R.S.D.) for 11 replicate determinations of 5.0 μg L−1 of As(III) was 3.0%. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for ETAAS determination and in the initial solution, was 36 for As(III). The linear concentration range was from 0.1 to 20 μg L−1. The developed method was applied to the determination of As(III) in lake water and river water.  相似文献   

3.
A preconcentration and determination method for humic and fulvic acids at trace levels in natural water samples was developed. Cloud point extraction was successfully employed for the preconcentration of humic acid (HA) and fulvic acid (FA) prior to the determination by using a flow injection (FI) system coupled to a spectrophotometric UV-Vis detector. The quantitative extraction of HA and FA within the pH range 1-12 was obtained by neutralization of the anionic charge on the humic substances with a cationic surfactant, hexadecyltrimethylammonium bromide (CTAB). This generated a hydrophobic species that was subsequently incorporated (solubilized) into the micelles of a non-ionic surfactant polyethylene glycol, tert-octylphenyl ether (Triton X-114). The FI method for HA and FA determination was developed by injection of 100 microl of the extracted surfactant-rich phase using an HPLC pump with spectrophotometric detection at 350 nm. A 50 ml sample solution preconcentration allowed an enrichment factor of 167. The limit of detection (LOD) obtained under the optimal conditions was 5 microg l(-1). The precision for ten replicate determinations at 0.2 mg l(-1) HA was 3.1% relative standard deviation (RSD), calculated from the peak heights. The calibration using the preconcentration system for HA and FA was linear with a correlation coefficient (r2) of 0.9997 at levels near the detection limits up to at least 1 mg l(-1). The method was successfully applied to the determination of HA and FA in natural water samples (river water).  相似文献   

4.
Nielsen S  Sloth JJ  Hansen EH 《Talanta》1996,43(6):867-880
A time-based flow-injection (FI) procedure for the determination of ultra-trace amounts of inorganic arsenic(III) is described, which combines hydride generation atomic absorption spectrometry (HG-AAS) with on-line preconcentration of the analyte by inorganic coprecipitation-dissolution in a filterless knotted Microline reactor. The sample and coprecipitating agent are mixed on-line and merged with an ammonium buffer solution, which promotes a controllable and quantitative collection of the generated hydroxide on the inner walls of the knotted reactor incorporated into the FI-HG-AAS system. Subsequently the precipitate is eluted with 1 mol 1(-1) hydrochloric acid, allowing ensuing determination of the analyte via hydride generation. The preconcentration of As(III) was tested by coprecipitation with two different inorganic coprecipitating agents namely La(III) and Hf(IV). It was shown that As(III) is more effectively collected by lanthanum hydroxide than by hafnium hydroxide, the sensitivity achieved by the former being approximately 25% better. With optimal experimental conditions and with a sample consumption of 6.7 ml per assay, an enrichment factor of 32 was obtained at a sample frequency of 33 samples h(-1). The limit of detection (3sigma) was 0.003 microg 1(-1) and the precision (relative standard deviation) was 1.0% (n = 11) at the 0.1 microg 1(-1) level.  相似文献   

5.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

6.
An indirect simple and rapid cloud point extraction is proposed for separation and preconcentration of sulfadiazine and its determination by flow injection‐flame atomic absorption spectroscopy (FI‐FAAS). The sulfadiazine from 35 mL of solution was readily converted to silver sulfadiazine upon addition of silver nitrate (9.7 × 10‐5 mol/L). Then, Triton X‐114 a non ionic surfactant was added and the solution was heated to 60 °C. At this stage, two separate phases was formed and silver sulfadiazine enters the surfactant rich phase of non‐ionic micelles of Triton X‐114. The surfactant‐rich phase (~50 μL) was then separated and diluted to 300 μL with acidic methanol. The concentration of silver in the surfactant‐rich phase which is proportional to the concentration of sulfadiazine in sample solution was determined by FI‐FAAS. The parameters affecting extraction and separation were optimized. Under the optimum conditions (i.e. pH 2‐10, silver concentration (9.7 × 10 ‐5 mol/L), Triton X‐114 (0.075% v/v) and temperature 60 °C) a preconcentration factor of 117 and a relative standard deviation of 4.9% at 37 μg L‐1 of sulfadiazine was obtained. The method was successfully applied to analysis of milk, urine and tablet samples and accuracy was determined by recovery experiments.  相似文献   

7.
A method for the preconcentration and speciation of chromium was developed. On-line preconcentration and determination were obtained using inductively coupled plasma optical emission spectrometry (ICP-OES) coupled with flow injection. To determinate the chromium (III) present in parenteral solutions, chromium was retained on activated carbon at pH 5.0. On the other hand, a step of reduction was necessary in order to determine total chromium content. The Cr(VI) concentration was then determined by difference between the total chromium concentration and that of Cr(III). A sensitivity enrichment factor of 70-fold was obtained with respect to the chromium determination by ICP-OES without preconcentration. The detection limit for the preconcentration of 25 ml of sample was 29 ng l−1. The precision for the 10 replicate determinations at the 5 μg l−1 Cr level was 2.3% relative standard deviation, calculated with the peak heights. The calibration graph using the preconcentration method for chromium species was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 60 μg l−1. The method can be applied to the determination and speciation of chromium in parenteral solutions.  相似文献   

8.
建立了以吡咯烷二硫代氨基甲酸铵(APDC)为络合剂、TritonX-100为表面活性剂的浊点萃取-热喷雾火焰原子吸收光谱法测定水样中痕量锌的方法.考查了APDC的浓度、溶液酸度、表面活性剂浓度、加热时间、水浴温度、干扰离子等实验条件对浊点萃取效率的影响.在最优化的实验条件下.方法的检出限为0.1 ng/mL,RsD为4...  相似文献   

9.
The flow‐injection differential‐pulse anodic stripping voltammetric (FI‐DP‐ASV) procedure has been developed for the determination of thallium concentration of the order of the single pM. Due to the analyte preconcentration at the electrode, DPASV is among the leaders in competition for achieving a detection limit as low as possible. The enrichment factor can be easily regulated by the duration of the preconcentration time. A DPASV measurement in a flow‐injection system enables the circulation of an analyzed sample and a medium exchange when preconcentration is completed. This approach ensures significant improvement of a background current. The measurements were performed in a cell of the wall‐jet type containing the mercury film electrode. One hour preconcentration was used for the determination of the lowest thallium concentrations. The developed method provides the opportunity to determine thallium in real environmental samples at the single pM level with the detection limit equal to 0.25 pM and RSD equal to 8.2%. This is by more than one order of magnitude better than the lowest detection limit reported in the literature (5 pM). Additionally, the medium exchange resulted in the improvement of the measuring accuracy, which was evidenced by the application of a certified reference material.  相似文献   

10.
Silva MF  Fernandez LP  Olsina RA 《The Analyst》1998,123(9):1803-1807
An extraction methodology based on cloud point phase separation of non-ionic surfactants has been developed for the preconcentration of ppb amounts of gadolinium in urine as a prior step to its determination by an absorptiometric procedure. A method based on the formation of complexes with 2-(3,5-dichloro-2-pyridylazo)-5-dimethylaminophenol was used for the extraction of Gd(III) in the surfactant-rich phase of non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5). The variables affecting the combined preconcentration-absorptiometric method have been evaluated and optimised. The extraction efficiency, linearity, and the limit of detection (LOD) of the method were determined. The optimised procedure was applied to determine total and free Gd(III) contents in real urine samples of patients after the NMR imaging diagnostic examination with contrast agent.  相似文献   

11.
A cloud point extraction (CPE) method has been developed for the preconcentration of trace aluminum prior to its determination by flame atomic absorption spectrometry (FAAS). The CPE method is based on the complex of Al(III) with Xylidyl Blue (XB) and then entrapped in non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of XB and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 50 was obtained for the preconcentration of Al(III) with 50 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 1.43 μg L− 1, and the relative standard deviation is 2.7% at determination of 100 μg L− 1 Al(III). The proposed method has been applied for determination of trace amount of aluminum in mineral water samples with satisfactory results. Also, the proposed method was applied to the certified reference materials. The results obtained were in good agreement with certified values.  相似文献   

12.
《Analytical letters》2012,45(4):809-822
Abstract

A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV‐ICP‐OES) detection was proposed for the determination of chromium species. Thenoyltrifluoracetone (TTA) was used as both an extractant for CPE of Cr(III) and a chemical modifier for ETV‐ICP‐OES determination. When the system temperature is higher than the cloud point temperature (CPT) of the selected surfactant, Triton X‐114, the complex of Cr(III) with TTA could enter the surfactant‐rich phase, whereas the Cr(VI) remained in aqueous solutions. Thus, an in situ separation of Cr(III) and Cr(VI) could be realized. The concentrated analyte was introduced into ETV‐ICP‐OES for determination of Cr(III) after proper disposal. Cr(VI) is reduced to Cr(III) prior to determining total Cr, and its assay is based on substracting of Cr(III) from total chromium. The main factors affecting cloud point extraction and the vaporization behavior of the analyte were investigated in detail. Under the optimized conditions, the limit of detection (LOD) for Cr(III) was 0.22 µg/L by preconcentration of a 10 mL sample solution, and the relative standard deviation (RSD) was 3.8% (CCr(III)=0.5 µg/mL, n=5). The proposed method was applied to the speciation of chromium in different water samples. In order to verify the accuracy of the method, a certified reference water sample was analyzed, and the results obtained were in good agreement with certified values.  相似文献   

13.
Brilliant green was used as a complexing agent in cloud point extraction (CPE) and applied for selective preconcentration of trace amounts of gold in geological matrices. The analyte in the initial aqueous solution was acidified with hydrochloric acid (0.1 M) and octylphenoxypolyethoxyethanol (Triton X-114) was added as a surfactant. After phase separation, based on the cloud point separation of the mixture, the surfactant rich phase was diluted with methanol and the analyte determined in the surfactant rich phase by flame atomic absorption spectrometry (FAAS). After optimization of the complexation and extraction conditions, a preconcentration factor of 31 was obtained for only 10 mL of sample. The analytical curve was linear in the range of 3–1000 ng mL−1 and the limit of detection was 1.5 ng mL−1. The proposed method was applied to the determination of gold in geological samples.  相似文献   

14.
Cloud point extraction (CPE) was applied as a preconcentration step prior to graphite furnace atomic absorption spectrometry (GFAAS) determination of manganese(II) and iron(III) in water samples. After complexation with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), the analytes could be quantitatively extracted to the phase rich in the surfactant p-octylpolyethyleneglycolphenylether (Triton X-100) and be concentrated, then determined by GFAAS. The parameters affecting the extraction efficiency, such as solution pH, concentration of PMBP and Triton X-100, equilibration temperature and time, were investigated in detail. Under the optimum conditions, preconcentration of 10 ml of sample solution permitted the detection of 0.02 ng ml(-1) of Mn(II) and 0.08 ng ml(-1) of Fe(III) with enrichment factors of 31 and 25 for Mn(II) and Fe(III), respectively. The proposed method was applied to determination of trace manganese(II) and iron(III) in water samples with satisfactory results.  相似文献   

15.
Dithizone (diphenylthiocarbazone) was used as a complexing agent in cloud point extraction for the first time and applied for selective preconcentration of trace amounts of silver. The analyte in the initial aqueous solution was acidified with sulfuric acid (pH<1) and Triton X-114 was added as a surfactant. After phase separation, based on the cloud point separation of the mixture, the surfactant rich phase was diluted with tetrahydrofuran (THF) and the analyte determined in the enriched solution by flame atomic absorption spectrometry. After optimization of the complexation and extraction conditions, a preconcentration factor of 43 was obtained for only 10 ml of sample. The analytical curve was linear in the range of 3-200 ng ml−1 and the limit of detection was 0.56 ng ml−1. The proposed method was applied to the determination of silver in water samples.  相似文献   

16.
A new analytical method using 1-(2-pyridylazo)-2-naphthol (PAN)-modified SiO2 nanoparticles as solid-phase extractant has been developed for the preconcentration of trace amounts of Sb(III) in different water samples. Conditions of the analysis such as preconcentration factor, effect of pH, sample volume, shaking time, elution conditions, and effects of interfering ions for the recovery of the analyte were investigated. The adsorption capacity of nanometer SiO2-PAN was found to be 186.25 micromol/g at optimum pH and the LOD (3sigma) was 0.60 microg/L. The extractant showed rapid kinetic sorption. The adsorption equilibrium of Sb(III) on nanometer SiO2-PAN was achieved in 10 min. Adsorbed Sb(III) was easily eluted with 4 mL 2 M hydrochloric acid. The maximum preconcentration factor was 62.20. The method was applied for the determination of trace amounts of Sb(III) in various water samples (tap, mineral water, and industrial effluents).  相似文献   

17.
《Analytical letters》2012,45(5-6):473-484
A novel sequential injection on-line column preconcentration method for ultra-trace cobalt determination by electrothermal atomic absorption spectrometry (ETAAS) using poly(etheretherketone) (PEEK) turnings as sorbent material was developed. The method was based on the on-line chelate complex formation and retention of target analyte with ammonium pyrrolidine dithiocarbamate (APDC) on the surface of PEEK-turnings and elution with methyl isobutyl ketone (MIBK). A 40 µL fraction of MIBK containing the bulk of analyte complex introduced directly into the transversely heated graphite tube atomizer of ETAAS for quantification. Acidity of sample solution, chelating reagent concentration, and preconcentration time were investigated and optimized separately, while all other factors were optimized by full factorial design optimization methodology. The significance of the variables and their interactions was estimated by employing analysis of variance (ANOVA) and Pareto chart. Under the optimum conditions the enhancement factor for cobalt determination was 60. The detection limit was 6 ng L?1 and the precision expressed as relative standard deviation (RSD) was 3.5% at 0.1 µg L?1 Co(II) concentration level, respectively. The proposed method was evaluated by analyzing water certified reference materials and spiked environmental samples.  相似文献   

18.
In the present work, a cloud point extraction (CPE) system has been proposed for determination of species de chromium in the natural water samples, Cr(III) and Cr(VI). The procedure was based on the reaction of Cr(III) with 1-(2-pyridilazo)-2-naphtol (PAN) in a surfactant solution (Triton X-114) yielding a hydrophobic complex, which then is entrapped “in situ” in the surfactant micelles. When the temperature of the system was higher than the cloud point of Triton X-114, the complex of Cr(III)-PAN entered the surfactant-rich phase and thus separation of the analyte from the matrix was achieved. Separation of the two phases was accomplished by centrifugation for 15 min at 2500 rpm. The Cr(VI) assay is based on its reduction to Cr(III) by ascorbic acid which subsequently reacts with PAN in a similar manner. The main factors affecting the cloud point extraction, such as complexation pH (7.7), buffer concentration (0.025 mol L− 1) and microwave irradiation time (10 min) were optimized by response surface methodology (RSM) using Box–Behnken design. Under the optimized conditions, the preconcentration system (50 mL sample) permitted an enrichment factor of 48, linear range of 2.5–80 μg L− 1, limit of detection and quantification of 0.7 and 2.5 μg L− 1, respectively, and the relative standard deviation (n = 10) of 2.0% for 50 μg L− 1 Cr(III) solution and (n = 10) 5.5% for 10 μg L− 1. The proposed procedure was applied to the speciation of chromium in river water samples. The procedure affords recoveries of 84–115% and a relative standard deviation lower than 4.2%. The analytical results of total chromium in the river water samples under study agreed well with those by electrothermal atomic absorption spectrometry (ET AAS). It is proved that the procedure can be successfully employed as an alternative to the commonly used preconcentration and speciation analytical techniques.  相似文献   

19.
A simple and practical preconcentration method using cloud point approach is proposed for the extraction and preconcentration of Cu (II). The analyte in the initial aqueous solution, acidified with HCl, is complexed with O,O-diethyldithiophosphate and Triton X-100 is added as a surfactant. After phase separation at 40°C based on cloud point of the mixture and dilution of the surfactant-rich phase with methanol, the enriched analyte is determined by flame atomic absorption spectrometry using conventional nebulization and the analytical wavelength used is 324.8 nm. The variables affecting the complexation and extraction steps were optimized. Under optimum conditions, preconcentration of 10 ml of sample in the presence of 0.1% (v/v) Triton X-100 permitted the detection of 0.94 ng ml−1 of Cu. Analytical graphs were rectilinear in the concentration range of 5-200 ng ml−1 and relative standard deviations were lower than 3%. The method affords recoveries in the range 97-101%. The method was successfully applied to the determination of Cu in drinking and rainwater, serum and human hair samples.  相似文献   

20.
The cloud-point methodology was successfully employed for the preconcentration of heavy metal cations at trace levels from aqueous samples prior to flame atomic absorption spectrometry (FAAS). Cations were taken into a complex with 8-quinolinol in an aqueous non-ionic surfactant, Triton X-114, medium and concentrated in the surfactant rich phase by bringing the solution to the cloud-point temperature. The preconcentration of only 100 mL of the solution with 1% Triton X-114 and 10(-3) M 8-quinolinol at pH 7.0 gave a preconcentration factor higher than 100 for most cations. Under these conditions, the detection limits of the cloud-point extraction-FAAS system were 0.8 - 15 microg/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号