共查询到20条相似文献,搜索用时 11 毫秒
1.
Rai DK Alvelius G Landin B Griffiths WJ 《Rapid communications in mass spectrometry : RCM》2000,14(14):1184-1194
The potential use of electrospray tandem mass spectrometry in the rapid characterisation of haemoglobin variants found in the Swedish population has been assessed. Analysis times of the order of 5 -10 min were routinely achieved, and identification of variants using mass spectrometry as the sole analytical technique was possible. However, additional information, readily available from isoelectric focusing experiments, made identification simpler and more secure. In the present communication we report on the identification of the alpha-chain variants, Hb Russ, Hb Le Lamentin and Hb Q-Iran. The identifications were confirmed by the use of nucleotide sequencing techniques. 相似文献
2.
Joachim Stach Dieter Zimmer Monika M
Der And Rainer Herzschuh 《Journal of mass spectrometry : JMS》1989,24(10):946-952
Derivatization of alkylated hydroxyaromatics with N-methyl-bis(trifluoracetamide) is used for a rapid screening for alkylated hydroxyaromatic compounds in complex mixtures by tandem mass spectrometry. Applications are based on a detailed investigation of the fragmentation reactions of derivatized alkylated phenols, 2,3-dihydroindenols, indenols, 1,2,3,4-terrahydronaphtbols and naphthols. As shown by daughter-ion mass spectra obtained in different field-free regions of a BEQQ-instrument, the loss of CF3COOH, CF3CO˙ or CF3COO˙, respectively, is common for the compounds studied and can be used for their detection by means of neutral mass loss scans. 相似文献
3.
Metal affinity capture tandem mass spectrometry (MAC-MSMS) is evaluated in a comparative study of a lysine-derived nitrilotriacetic acid (N(alpha), N(alpha)-bis-(carboxymethyl)lysine, LysNTA) and an aspartic-acid-related iminodiacetic acid (N-(4-aminobutyl)aspartic acid, AspIDA) as selective phosphopeptide detection reagents. Both LysNTA and AspIDA spontaneously form ternary complexes with Ga(III) and phosphorylated amino acids and phosphopeptides upon mixing in solution. Collision-induced dissociation of positive complex ions produced by electrospray produces common fragments (LysNTA + H)(+) or (AspIDA + H)(+) at m/z 263 and 205, respectively. MSMS precursor scans using these fragments as reporter ions allow one to selectively detect multiple charge states of phosphopeptides in mixtures. It follows from this comparative study that LysNTA is superior to AspIDA in detecting phosphopeptides, possibly because of the higher coordination number and greater stability constant for Ga(III)-phosphopeptide complexation of the former reagent. In a continuing development of MAC-MSMS for proteomics applications, we demonstrate its utility in a post-column reaction format. Using a simple post-column-reaction 'T' and syringe pump to deliver our chelating reagents, alpha-casein tryptic phosphopeptides can be selectively analyzed from a solution containing a twofold molar excess of bovine serum albumin. The MAC-MSMS method is shown to be superior to the commonly used neutral loss scan for the common loss of phosphoric acid. 相似文献
4.
Whalen KM Rogers KJ Cole MJ Janiszewski JS 《Rapid communications in mass spectrometry : RCM》2000,14(21):2074-2079
An automated flow injection analysis (FIA) mass spectrometry system (AutoScan) was developed to allow rapid unattended determination of optimal conditions during mass (ms) and tandem mass spectrometry (ms/ms) on new chemical entities (NCEs) arranged in 96-well plates. The 96-well plate is placed on the deck of a modified Gilson Multiprobe autosampler for injection into a PE Sciex API 2000 triple quadrupole mass spectrometer. A customized software interface is used to create the necessary scan experiments by associating each 96-well plate of NCEs to be scanned with an index file containing data on the identity of each analyte and its expected molecular weight. Analytes are injected four at a time into a custom injection manifold and conventional mass spectra are acquired in both polarities (+/-) using an alternating positive/negative Q1 scan function. The software determines the optimal polarity and definitive precursor ion for all analytes and uses the results to build the injection sequence for product ion scanning. The samples are automatically re-injected under MS/MS conditions, and product ion scans that loop among different collision energies are collected for each analyte. The resulting data are processed automatically and the optimal MS/MS transitions for each analyte are selected. A color-coded graphical interface facilitates data review. Any unusual ion transitions or transposition errors made during plate preparation are noted and corrected. Complete MS and MS/MS conditions are obtained for 96 compounds in about one hour and the resulting data are available for download as sample control injection sequence files. 相似文献
5.
Susan D. Richardson John M. McGuire Alfred D. Thruston George L. Baughman 《Journal of mass spectrometry : JMS》1992,27(3):289-299
Eight monosulfonated and disulfonated azo dyes were analyzed using liquid secondary ion mass spectrometry/tandem mass spectrometry, in the negative ion mode, under low-energy collision conditions (110–150 eV). Many structurally characteristic fragment ions were obtained, several of which have not been reported previously using other mass spectrometric techniques. Among the structurally important ions observed were those due to loss of SO2, SO3 and various aromatic substituents, such as NO2 and NHCOCH3. Losses of N2 were also proposed. In addition, product ions due to cleavage at the azo linkage were observed, and also SO3? and HSO3? ions. Several of the azo cleavage product ions detected did not contain sulfonate groups. Possible pathways for the formation of product ions are proposed. The structural information obtained should help to better characterize and identify sulfonated azo dyes in the future. 相似文献
6.
We report a 'top-down' approach for characterization of proteins, and identification of binding sites in protein-drug complexes using nanoelectrospray ionization hybrid quadrupole time-of-flight tandem mass spectrometry (nanoESI-MS/MS). The efficiency of direct fragmentation of intact protein ions and the feasibility of this method were initially demonstrated using several well-characterized proteins with different molecular weights including metallothionein (6126 Da), cytochrome c (horse, 12360 Da), myoglobin (horse, 16592 Da), and hemoglobin (human, 64453 Da). Simply varying collision energy without enzyme digestion and gel or LC separation generated a range of peptide fragments of these proteins. Over 80% of these peptide ions matched those in the SWISS-PROT database with mass accuracy of 8 to 32 ppm with external calibration. This technique was further applied to fragment a cisplatin-metallothionein complex to identify the binding sites, demonstrating a potential application in the study of drug-protein binding. 相似文献
7.
Meng F Wiener MC Sachs JR Burns C Verma P Paweletz CP Mazur MT Deyanova EG Yates NA Hendrickson RC 《Journal of the American Society for Mass Spectrometry》2007,18(2):226-233
Label-free LC-MS profiling is a powerful quantitative proteomic method to study relative peptide abundances between two or more biological samples. Here we demonstrate the use of a previously described comparative LC-MS method, differential mass spectrometry (dMS), to analyze high-resolution Fourier transform mass spectrometry (FTMS) data for detection and quantification of known peptide differences between two sets of complex mixtures. Six standard peptides were spiked into a processed plasma background at fixed ratios from 1.25:1 to 4:1 to make two sets of samples. The resulting mixtures were analyzed by microcapillary LC-FTMS and dMS. dMS successfully identified five out of the six peptides as statistically significant differences (p 相似文献
8.
Johanna Gra?mann Romy K. Scheerle Thomas Letzel 《Analytical and bioanalytical chemistry》2012,402(2):625-645
This review covers recent developments in mass spectrometry-based applications dealing with functional proteomics with special emphasis on enzymology. The introduction of mass spectrometry into this research field has led to an enormous increase in knowledge in recent years. A major challenge is the identification of “biologically active substances” in complex mixtures. These biologically active substances are, on the one hand, potential regulators of enzymes. Elucidation of function and identity of those regulators may be accomplished by different strategies, which are discussed in this review. The most promising approach thereby seems to be the one-step procedure, because it enables identification of the functionality and identity of biologically active substances in parallel and thus avoids misinterpretation. On the other hand, besides the detection of regulators, the identification of endogenous substrates for known enzymes is an emerging research field, but in this case studies are quite rare. Moreover, the term biologically active substances may also encompass proteins with diverse biological functions. Elucidation of the functionality of those—so far unknown—proteins in complex mixtures is another branch of functional proteomics and those investigations will also be discussed in this review. 相似文献
9.
A CEC/ESI-MS/MS combined system has been developed for the separation and on-line structural analysis of neutral oligosaccharides. Various types of isomeric oligosaccharides were first successfully separated by CEC using polar monolithic columns, while the on-line tandem mass spectrometry has been explored to differentiate and elucidate the structures of isomeric oligosaccharides. The experimentally obtained tandem spectra usually provide sequence, branching, and linkage information. Oligosaccharide isomers with a different monomeric composition and branching showed different patterns of glycosidic linkage cleavage (B- and Y-ion series), allowing us to deduce their sequence and branching points. Isomers with different linkages were distinguished by identifying cross-ring fragment ions (A-ion series). While (1-->4) linkages yielded dominant (0,2)A ions, (1-->6) linkages showed an extensive and complete cross-ring cleavage series: (0,2)A, (0,3)A, and (0,4)A ions. Although the anomeric configurations and monosaccharide identification are rarely obtained from tandem MS, the relevant mixture components can be completely resolved with high-efficiency CEC columns featuring a polar functionality. 相似文献
10.
High temperature gas chromatography and gas chromatography/mass spectrometry are used in the characterization of complex natural mixtures of permethylated oligosaccharides released from proteins or lipids. The high resolution allows separation of isomeric compounds and the mass range extends to oligosac-charides around molecular mass 2000 daltons or 10 sugar residues for isomalto-oligosaccharides. The mass spectra of permethylated oligosaccharide alditols from mucin glycopeptides are very informative and the approach allows a simple and rapid characterization of these complex components. 相似文献
11.
Santiago Vazquez Roger J. W. Truscott Richard A. J. O’Hair Allan Weimann Margaret M. Sheil 《Journal of the American Society for Mass Spectrometry》2001,12(7):786-794
A combination of accurate mass measurement and tandem mass spectrometry (both product ion and precursor ion scans) have been used to characterize the major fragment ions observed in the ESI mass spectrum of kynurenine. Kynurenine is a metabolite of tryptophan found in the human lens and is thought to play a role in protecting the retina from UV-induced damage. Three major fragmentation pathways were evident, following initial elimination either of ammonia, H2O and CO or the imine form of glycine. The latter is proposed to occur via the formation of an ion-molecule complex. In the case of loss of H2O and CO from deaminated kynurenine, there is evidence for an acylium ion intermediate, which is not observed for the loss of H2O and CO directly from protonated kynurenine. Product ion scans of deuterated kynurenine enabled the elucidation of structural rearrangements that were not evident in the spectra of the native compound. Since UV filter compounds can often only be isolated in small quantities from the lens, this study forms the basis for the characterization of novel UV filter compounds using mass spectrometry. The approach presented here may also be useful for the characterization of related classes of small molecules. 相似文献
12.
Ilag LL Ubarretxena-Belandia I Tate CG Robinson CV 《Journal of the American Chemical Society》2004,126(44):14362-14363
The protein-micelle complex formed between the protein EmrE and the lipid dodecylmaltoside has been examined by mass spectrometry. The results show that despite the unfavorable hydrophobic environment in the mass spectrometer it is possible to preserve protein submicelle complexes in the gas phase. The peaks assigned to the submicelle complexes are broad in nature and consistent with a heterogeneous distribution of lipid molecules attached to the protein complex. As such, the spectrum cannot be interpreted. To simplify this complexity we used a tandem mass spectrometry procedure in which discrete m/z values are isolated from the peak and subjected to collision-induced dissociation. These spectra reveal clusters of DDM molecules as well as sequential release of TPP+ and EmrE from the complex as the collision cell voltage is raised. Taken together, the results provide direct evidence for drug binding within a relevant gas-phase protein-micelle complex. 相似文献
13.
Fragmentation study of simvastatin and lovastatin using electrospray ionization tandem mass spectrometry 总被引:2,自引:0,他引:2
The fragmentation mechanism of simvastatin and lovastatin was investigated using both triple quadrupole and ion trap mass spectrometers. The elimination of the ester side-chain followed by dehydration and dissociation of the lactone moiety were observed as the main fragmentation pathways for both compounds. Another major fragmentation process was a C==C double-bond facilitated rearrangement. Our tandem mass spectrometric (MS/MS) data suggested that the beta-hydroxy group was involved in the fragmentation by interacting with the carboxyl group generated from the ring opening of the lactone. As a result, a facile neutral loss of 60 Da (CH(3)COOH or a combination of CH(2)==C==O and H(2)O) was detected. MS/MS studies of the structural analogs also provided evidence that the dehydration of the beta-hydroxy lactone generated preferentially the beta,gamma-unsaturated lactones. 相似文献
14.
Brett Harper Elizabeth K. Neumann Sarah M. Stow Jody C. May John A. McLean Touradj Solouki 《Analytica chimica acta》2016
Ion mobility (IM) is an important analytical technique for determining ion collision cross section (CCS) values in the gas-phase and gaining insight into molecular structures and conformations. However, limited instrument resolving powers for IM may restrict adequate characterization of conformationally similar ions, such as structural isomers, and reduce the accuracy of IM-based CCS calculations. Recently, we introduced an automated technique for extracting “pure” IM and collision-induced dissociation (CID) mass spectra of IM overlapping species using chemometric deconvolution of post-IM/CID mass spectrometry (MS) data [J. Am. Soc. Mass Spectrom., 2014, 25, 1810–1819]. Here we extend those capabilities to demonstrate how extracted IM profiles can be used to calculate accurate CCS values of peptide isomer ions which are not fully resolved by IM. We show that CCS values obtained from deconvoluted IM spectra match with CCS values measured from the individually analyzed corresponding peptides on uniform field IM instrumentation. We introduce an approach that utilizes experimentally determined IM arrival time (AT) “shift factors” to compensate for ion acceleration variations during post-IM/CID and significantly improve the accuracy of the calculated CCS values. Also, we discuss details of this IM deconvolution approach and compare empirical CCS values from traveling wave (TW)IM-MS and drift tube (DT)IM-MS with theoretically calculated CCS values using the projected superposition approximation (PSA). For example, experimentally measured deconvoluted TWIM-MS mean CCS values for doubly-protonated RYGGFM, RMFGYG, MFRYGG, and FRMYGG peptide isomers were 288.8 Å2, 295.1 Å2, 296.8 Å2, and 300.1 Å2; all four of these CCS values were within 1.5% of independently measured DTIM-MS values. 相似文献
15.
GC/MS and GC/MS/MS in a quadrupole ion trap were used to analyze for anthraquinone, alkyl anthraquinones, benz[a]anthracene-7, 12-dione and 9-fluoranone in a sediment obtained from an aluminum smelter settling pond contaminated with polycyclic aromatic hydrocarbons. By standard GC/MS analysis many of these target compounds were either undetectable or their confirmation uncertain because of matrix interferences. Detection and identification were greatly improved by using GC/MS/MS. GC/MS/MS analyses were performed by selecting the molecular ion (M) of a target compound and fragmenting it via collision induced dissocation (CID) to yield product ions corresponding to loss of CO for unsubstituted compounds or CO plus CH(3) for alkylated compounds. The CID conditions were optimized using anthraquinone and 2-methylanthraquinone standards by varying the CID excitation energy and RF storage levels to yield optimum amounts of fragment ions. CID experiments were performed using both resonant and non-resonant wave forms. Although both excitation techniques gave comparable results for the removal of matrix interferences, non-resonant excitation provided more characteristic spectra for the alkylated anthraquinones. Monitoring of secondary fragmentation products, such as M-2CO, provided greater discrimination from matrix interferences than the use of primary fragmentation products, such as M-CO. 相似文献
16.
di Donna L Grassi G Mazzotti F Perri E Sindona G 《Journal of mass spectrometry : JMS》2004,39(12):1437-1440
A high-throughput method is presented for the determination of rotenone in contaminated matrices. The procedure involves atmospheric pressure chemical ionization tandem mass spectrometry with a triple-quadrupole instrument and the use as internal standard of a cycloadduct derivative of rotenone itself. The method was applied to the evaluation of the decay of rotenone in olives and olive oil at various times after exposure to the contaminant. 相似文献
17.
Analysis of trace levels of carbohydrate monomers in complex matrices requires excellent discrimination of the peaks of interest from background noise. Minimizing contaminating peaks introduced during sample preparation and chromatography is extremely important. However, the exquisite selectivity of the mass spectrometer is essential as a chromatographic detector in this regard. Traditionally gas chromatography-mass spectrometry (GC-MS) has been the method of choice for trace analysis of derivatized carbohydrates. Recent improvements in commercial tandem mass spectrometers (MS-MS) are encouraging the use of GC-MS-MS for improved specificity in trace analysis. There has also been an explosion in applications of electrospray ionization (ESI) for sensitive introduction of polar molecules (including sugars) into the mass spectrometer. This has encouraged ongoing developments in high-performance liquid chromatography-mass spectrometry (LC-MS) and MS-MS of underivatized carbohydrates. This has the potential to dramatically simplify sample preparation. However, as yet LC-MS and MS-MS do not match the sensitivity of GC-MS or GC-MS-MS. Developments in analysis of sugar monomers from complex matrices using chromatography (GC/LC) in conjunction with mass spectrometry (MS, MS-MS) or stand-alone MS-MS are discussed. 相似文献
18.
Lucia Bartella Leonardo Di Donna Anna Napoli Giovanni Sindona Fabio Mazzotti 《Journal of mass spectrometry : JMS》2020,55(9)
A fast methodology for the assay of parabens in drug and cosmetic preparations has been presented. The procedure developed is based on paper spray tandem mass spectrometry and isotope dilution approach. For each investigated paraben, the corresponding labeled standard has been used in order to improve the accuracy and reproducibility of the analyses. The MS experiments have been performed under MRM conditions, monitoring the transitions [M‐H]? → m/z 92 and [M‐H]? → m/z 98, respectively, for each analyte and the corresponding labeled internal standard. The quantitative assay has been performed using a calibration curve built from 2 to 15 mg/L. The method accuracy, in all case near 100%, was evaluated using fortified samples at two concentration levels, which are representative of the lower and the higher portion of calibration curve. The good values of LOQ, LOD, and reproducibility confirm the consistency of the developed approach. 相似文献
19.
Ya-Jun Zheng Andreas Staempfli Julie A. Leary 《Journal of the American Society for Mass Spectrometry》1993,4(12):943-948
Fast-atom bombardment tandem mass spectrometry and the semiempirical molecular orbital method were used to investigate the mechanism of gas-phase aldose-ketose isomerization process in lithiated 1,3 linked disaccharide isomers. Both the 1,3 hydrogen shift and hydride transfer mechanisms were investigated. Our experimental and theoretical calculations support the latter. The hydride transfer mechanism in these lithium-coordinated systems is similar to the xylose isomerase catalyzed aldose-ketose isomerization. 相似文献
20.
A simple and rapid method for determining ethylenebisdithiocarbamates (EBDCs; mancozeb, maneb, and zineb) in fruits and vegetables
is described. EBDCs are transformed into dimethylethylenebisdithiocarbamate (EBDC-dimethyl) by methylation after their decomposition
with ethylenediaminetetraacetic acid (EDTA). These processes were performed simultaneously in this method. Dimethyl sulfate
was used as the methylation reagent, and acetonitrile extracts obtained from partitioning with anhydrous magnesium sulfate
and sodium chloride were subjected to dispersive solid-phase extraction with the primary secondary amine sorbent. Liquid chromatography
with tandem mass spectrometry in the positive heated-electrospray ionization mode was used for the determination of EBDC-dimethyl
produced from EBDCs. The method was validated at levels of 10, 50, and 100 ng g−1 maneb as a representative EBDC. The recoveries of the present method were between 71 and 101%. The limits of detection and
quantification were 0.24 and 0.8 ng g−1 maneb, respectively. 相似文献