首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Carboxylic multi-walled carbon nanotubes (c-MWNT) have been immobilized into a fused-silica capillary for capillary electrochromatography. The c-MWNT were successfully incorporated after the silanization and coupling with glutaraldehyde on the inner surface of the capillary. The electrochromatographic features of the c-MWNT immobilized stationary phase have been evaluated for the analysis of different compounds of pharmaceutical interest. The results indicated high electrochromatographic resolution, good capillary efficiency and retention factors. In addition, highly reproducible results between runs, days and capillaries were obtained.  相似文献   

2.
Quigley WW  Ecker ST  Vahey PG  Synovec RE 《Talanta》1999,50(3):569-576
The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m(-1), was obtained for resorcinol, at a retention factor of k'=4.88 (retention time of 9.55 min at 1 ml min(-1) for a 25 cmx4.6 mm i.d. column, packed with 5 mum diameter particles with the cyano propyl stationary phase). A separation via reversed phase liquid chromatography (RP-LC) with a 100% water mobile phase of six phenols and related compounds was compared to a separation of the same compounds by traditional RP-LC, using octadecylsilane (ODS), i.e. C18, bound to silica and an aqueous mobile phase modified with acetonitrile. Nearly identical analysis time was achieved for the separation of six phenols and related compounds using the cyano propyl stationary phase with a 100% water mobile phase, as compared to traditional RP-LC requiring a relatively large fraction of organic solvent modifier in the mobile phase (25% acetonitrile:75% water). Additional understanding of the retention mechanism with the 100% water mobile phase was obtained by relating measured retention factors of aliphatic alcohols, phenols and related compounds, and chlorinated hydrocarbons to their octanol:water partition coefficients. The retention mechanism is found to be consistent with a RP-LC mechanism coupled with an additional retention effect due to residual hydroxyl groups on the cyano propyl stationary phase. Advantages due to a 100% water mobile phase for the chemical analysis of alcohol mixtures and chlorinated hydrocarbons are reported. By placing an absorbance detector in-series and preceding a novel drop interface to a flame ionization detector (FID), selective detection of a separated mixture of phenols and related compounds and aliphatic alcohols is achieved. The compound class of aliphatic alcohols is selectively and sensitively detected by the drop interface/FID, and the phenols and related compounds are selectively and sensitively detected by absorbance detection at 200 nm. The separation and detection of chlorinated hydrocarbons in a water sample matrix further illustrated the advantages of this methodology. The sensitivity and selectivity of the FID signal for the chlorinated hydrocarbons are significantly better than absorbance detection, even at 200 nm. This methodology is well suited to continuous and automated monitoring of water samples. The applicability of samples initially in an organic solvent matrix is explored, since an organic sample matrix may effect retention and efficiency. Separations in acetonitrile and isopropyl alcohol sample matrices compared well to separations with a water sample matrix.  相似文献   

3.
A poly(dimethylsiloxane)(PDMS)/glass hybrid microchip for on-line solid phase extraction (SPE) and electrophoresis separation has been developed and evaluated. The SPE microchannel was crossed to the electrophoresis microchannel. All the microfluidic channels were etched on the glass substrate. The magnetic microspheres were coated with hydroxyl-terminated poly-dimethylsiloxane (PDMS-OH) serving as extraction phase, which could be conveniently immobilized into the sample pretreatment channel by magnetic field. The PDMS-OH microspheres were mobilized into and out of the pretreatment channel by injection flow. The 0.1 μmol/L solution of fluorescence isothiocyanate (FITC)-labeled phenylalanine (Phe) was electrically injected into the SPE channel and extracted onto the PDMS-OH microspheres bed. The enriched FITC-labeled Phe was electrically eluted by 9 mmol/L sodium acetate containing 10% acetonitrile and electrically driven into the electrophoresis channel and then separated. The preconcentration factor could reach 87.5 after sufficient extraction. A linear preconcentration curve was obtained with the initial FITC-labeled Phe concentration ranging from 6 nmol/L to 300 nmol/L (R 2=0.9922) with 200 s loading time. The detection limit (S/N=3) for the FITC-labeled Phe was 3 nmol/L.  相似文献   

4.
Capillary electrochromatography requires the deposition of a stationary phase inside the capillary. In this paper the sol-gel method is proposed for this purpose. The gels were prepared externally and injected into a fused-silica capillary, where anchorage to the capillary wall was possible through condensation reactions between the silanol groups of the capillary wall and the residual silanol groups the gel. Contrary to a commonly used practice, alkaline pretreatment of the inner capillary wall prior to the introduction and anchoring of the gel was found to be only marginally effective in improving the mechanical stability of the column. The influence of various parameters, such as the pH, the water content, the presence of alcohol (ethanol) on the formation of tetraethoxysilane (TEOS)-n-octyltriethoxysilane (C8-TEOS) hybrid gels of varied composition is discussed. The pH and the amount of water present were found to be the determining factors in the preparation of a stable gel with the desired mechanical and chromatographic properties. By carrying out the gel formation at 80 degrees C, capillary columns could be produced in 2.5 h. While an acidic pH was required during (external) gel formation, subsequent treatment of the gel inside the capillary with an alkaline solution ('aging') was found to improve separation and stationary phase capacity significantly. The capillary columns were subsequently used to separate a mixture of polycyclic aromatic hydrocarbons in less than 3 min.  相似文献   

5.
6.
The feasibility of using capillary columns equipped with silica frits and packed with a polymer-based anion exchanger (Dionex AS9-HC) for CEC separations of inorganic anions has been investigated. Experiments using a conventional 25 cm packed bed, and mobile phase flow that is a combination of hydrodynamic and electroosmotic flow were used to demonstrate that by varying the applied voltage (electrophoresis component) or the concentration of the competing ion in the mobile phase (ion-exchange component), considerable changes in the separation selectivity could be obtained. Using an artificial neural network, this separation system was modelled and the results obtained used to determine the optimum conditions (9 mM perchlorate and −10 kV) for the separation of eight inorganic anions. When a short (8 cm) packed bed was used, with detection immediately following the packed section, the separation of eight test analytes in under 2.2 min was possible using pressure-driven flow and a simple step voltage gradient. A more rapid separation of these analytes was obtained by only applying high voltage (−30 kV), where many of the same analytes were separated in less than 20 s and with a different separation selectivity to that obtained in conventional ion-exchange or capillary electrophoresis separations.  相似文献   

7.
Li M  Liu X  Jiang F  Guo L  Yang L 《Journal of chromatography. A》2011,1218(23):3725-3729
Enantioselective open-tubular CEC (OTCEC) with thiolated β-CD modified gold nanoparticles (CD-GNPs) as stationary phase was developed. The enantioselective OT capillary column was fabricated by electrostatic assembly of poly(diallydimethylammonium chloride) (PDDA) followed by self-adsorption of negatively charged CD-GNPs. The enantioselective capillary column has a steady EOF mobility over a wide pH range of 3.0 to 9.2 (RSD 4.8%), and is quite stable over 240 min with very good column to column reproducibility. Efficient enantioseparation of the presented method was demonstrated by analyzing three drug enantiomers. Our results show that the column exhibits good run-to-run repeatability for enantioseparations and can maintain the enantioselectivity for more than 1 month if the column was stored in CD-GNPs solution at 4 °C.  相似文献   

8.
Végvári A  Hjertén S 《Electrophoresis》2002,23(20):3479-3486
We have designed a new class of microdevices composed of a supporting plastic (polyvinyl chloride, PVC) plate integrated with a groove for a piece of fused silica capillary (the separation channel), a slit for on-tube detection, an "islet" for the application of sample, electrode vessels and platinum electrodes. The design permits electrophoretic, electrochromatographic and chromatographic separations with on-tube UV detection. The efficient heat dissipation allows relatively high field strengths. This article is the first one dealing with microdevices where polymer solutions are replaced by homogeneous gels. A new type of gels synthesized from acrylamide and 2-hydroxy-3-allyloxy-propyl-beta-cyclodextrin (allyl-beta-CD) as a cross-linker was employed for electrophoresis and electrochromatography. 2-Acrylamido-2-methylpropanesulfonic acid was added to the monomer solution to create a high electroendosmotic flow in electrochromatographic runs. These gels have excellent electrochromatographic and electrophoretic properties for low-molecular-weight compounds and DNA, as shown previously, namely high resolution combined with high stability. The unique cross-linker can be used for specific interaction with the alkyl and phenyl groups. The tripeptide glutathione (gamma-L-glutamyl-L-cysteinyl-glycine) and its benzyl conjugates were selected as model compounds to study the resolving power of the gel because they are difficult to separate by free zone electrophoresis. The limit of detection (LOD) for S-benzyl-glutathione was determined (ca. 7 microM). Run-by-run reproducibility was high (the separation factor of glutathione in the gel was 0.3 with 2.5% coefficient of variation, CV). Neutral compounds (acetone, acetophenone, propiophenone and butyrophenone) were separated electrochromatographically in the gel. The influence of organic solvent (acetonitrile) on the electroendosmotic mobility was similar to that in reversed-phase separations, although the separation mechanism is different. ATP, ADP and AMP were separated in less than 10 s by free-zone electrophoresis.  相似文献   

9.
Chen JL 《Electrophoresis》2006,27(4):729-735
A synthetic coppermesogenic polymer is prepared and then covalently bonded to the siloxane-based deactivated column as the stationary phases of open-tubular CEC with essentially high phase ratio. The EOF generated from the modified phase is surveyed through conventional aqueous buffers and hydroorganic mobile phases. Zeta potentials, which are computed from the EOF data and the ratio of dielectric constant to viscosity, are plotted as a function of pH, ionic molarity, and compositional range. These plots responsible for the electroosmotic characteristic of the bonded phases are found to be like those of bare fused-silica or deactivated columns through decreasing or increasing the ACN content in the mobile phase, respectively. This two-phase characteristic is basically derived from the polymeric configuration with carboxylato ligands attached onto the polysiloxane backbone. Phthalates and amino acids are suitable probes to examine the two phenomena, more-polar and less-polar mediums, respectively, and to judge whether the chromatographic retention is the major source of separation mechanism. With the mixing modes of Lewis acid-base interaction, dispersive force, and shape discrimination, the chromatographic partition adequately accomplishes the uneasily resolved separations by only CZE mode, although the electrophoretic migration is truly somewhat involved.  相似文献   

10.
11.
The capillary electrochromatographic (CEC) analysis of basic compounds on octadecyl-silica stationary phases (Hypersil ODS and Spherisorb ODS I) was studied. A basic drug (fluvoxamine) and one of its possible impurities were used as test compounds. With an eluent of acetonitrile-phosphate buffer (pH 7.0), the compounds could be baseline-separated; however, broad and tailing peaks were obtained. To minimise detrimental interactions with residual silanol groups, the pH of the mobile phase was lowered to 2.5, but the plate numbers were still quite low (<2.6x10(4) plates/m). Addition of a masking agent (hexylamine or triethylamine) to the mobile phase resulted in much better peak efficiencies (ca. 1x10(5) plates/m). Therefore, the influence of the amine concentration and pH of the mobile phase on the CEC performance (peak width, peak tailing, electroosmotic flow, selectivity) was investigated in detail. Highest efficiencies (2.8x10(5) plates/m) could be obtained with the Spherisorb column, while the Hypersil column offered a better selectivity. Furthermore, the results show that the residual silanol groups are (at least partly) responsible for the separation of the basic compounds and that the amount of injected sample has an unusually large effect on the peak efficiency. The usefulness of the system for impurity profiling was demonstrated with a mixture containing fluvoxamine and its stereoisomer (a possible impurity) at the 0.1% level. The general effectiveness of amine additives in CEC was illustrated by the separation of a mixture of five structurally different basic drugs yielding plate numbers in the 1x10(5)-3x10(5) plates/m range. Comparison with capillary electrophoretic analysis revealed a unique selectivity of the CEC system which is based on both electrophoretic mobility and chromatographic partitioning.  相似文献   

12.
Enantiomeric separation of chiral pharmaceuticals is carried out in aqueous and non-aqueous packed capillary electrochromatography (CEC) using a teicoplanin chiral stationary phase (CSP). Capillaries were slurry packed with 5 microm 100-A porous silica particles modified with teicoplanin and initially evaluated using a non-aqueous polar organic mode system suitability test for the separation of metoprolol enantiomers (Rs = 2.3 and 53000 plates m(-1)). A number of pharmaceutical drugs were subsequently screened with enantioselectivity obtained for 25 racemic solutes including examples of neutral, acidic and basic molecules such as coumachlor (Rs = 3.0 and 86000 plates m(-1)) and alprenolol (Rs = 3.3 and 135000 plates m(-1)) in reversed-phase and polar organic mode, respectively. A statistical experimental design was used to investigate the effects of non-aqueous polar organic mobile phase parameters on the CEC electroosmotic flow, resolution and peak efficiency for two model solutes. Results primarily indicated that higher efficiency and resolution values could be attained at higher methanol contents which is similar to findings obtained on this phase in liquid chromatography.  相似文献   

13.
Racemic mixtures of tryptophan and dinitrobenzoyl leucine have been successfully resolved by capillary electrochromatography (CEC) using the macrocyclic antibiotic teicoplanin, covalently bonded to a 5 microns silica support. Modification of a previously published packing procedure was required to pack reliable capillaries, capable of performing enantiomeric separations. Good levels of enantioselectivity were obtained in all cases, with optimised separations being performed in less than 6 min. Retention times, resolution and reproducibility are discussed.  相似文献   

14.
Norton D  Shamsi SA 《Electrophoresis》2008,29(10):2004-2015
The preparation and characterization of a novel lithocholic acid (LCA)-based liquid crystalline (LC) stationary phase (SP) suitable for application in packed-column CEC and CEC coupled to MS is described. The extent of bonding reactions of LCA-SP was assessed using 1H-NMR, 13C-NMR and elemental analysis. This characterization is followed by application of the LCA-SP for separation of beta-blockers, phenylethylamines (PEAs), polyaromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Using the optimum mobile phase operating conditions (pH 3.0-4.5, 10 mM ammonium acetate, 85% v/v ACN), a comparison of the chromatographic ability of the aminopropyl silica phase vs. the LCA-bonded phase was conducted. The results showed improved selectivity for all test analytes using the latter phase. For example, the CEC-MS of beta-blockers demonstrated that the LCA-bonded phase provides separation of six out of seven beta-blockers, whereas the amino silica phase provides four peaks of several co-eluting beta-blockers. For the CEC-MS analysis of PEAs, the LCA-bonded phase showed improved resolution and different selectivity as compared to the aminopropyl phase. An evaluation of the retention trends for PEAs on both phases suggested that the PEAs were retained based on varying degree of hydroxyl substitution on the aromatic ring. In addition, the MS characterization shows several PEAs fragment in the electrospray either by loss of an alkyl group and/or by loss of H2O. Finally, the LCA-bonded phase displayed significantly higher separation selectivity for PAHs and PCBs as compared to the amino silica phase.  相似文献   

15.
Capillary columns were packed with 3 microns C18 stationary phase, interfaced with an ultraviolet-laser based thermo-optical absorbance detector, and evaluated for separation of a mixture of phenylthiohydantoin-amino acids. These columns demonstrated consistent performance with a relative standard deviation (RSD) for migration time of less than 1.5% and a separation efficiency of 216,000 plates/m for the electroosmotic flow marker, thiourea. The thermo-optical absorbance detector was based on a 248 nm krypton-fluoride excimer laser. Detection limits (3 sigma) ranged from 1.6 to 4.8 x 10(-7) M phenylthiohydantoin (PTH)-amino acid injected onto the column, which is a factor of three superior to those obtained in micellar electrokinetic chromatographic analysis of these compounds. A mixture of 17 PTH amino acids was injected onto the capillary; 13 components were nearly baseline resolved in 14 min.  相似文献   

16.
Enantiomeric separations in capillary electrochromatography (CEC) carried out using a continuous-bed chiral stationary phase (CSP) based on the macrocyclic antibiotic, vancomycin, is presented. The continuous beds were prepared from methacryloxypropyl modified fused silica capillaries (100 microm ID) by in situ copolymerization of N-(hydroxymethyl)acrylamide and piperazine diacrylamide with vinyl sulfonic acid comonomer used to introduce ionic functionality and thus a strong electroosmotic flow (EOF). The CSP was subsequently prepared by immobilizing the vancomycin stationary phase by reductive amination. Preliminary results have indicated that an extremely strong EOF is obtained in both the nonaqueous polar organic (15.2 x 10(-5) cm2 V(-1) s(-1) and the aqueous reversed-phase modes of operation (8.5 x 10(-5) cm2 V(-1) s(-1)). Enantioselectivity was obtained for four racemic compounds, the best of which was in the case of thalidomide which was separated in 10 minutes with high resolution (Rs = 2.5) and efficiency (120,000 plates meter(-1)) values.  相似文献   

17.
This work presents the application of membrane technology for the fabrication of stationary phase for CEC columns using the technique based on phase inversion of polymer solution. A blend of polyimide P84 and sulphonated poly(ether ether ketone was processed via immersion precipitation dry‐wet spinning into small‐bore porous fiber. The morphology, zeta potential, and performance of the porous structure in the CEC separation were investigated. Noncharged molecules (as markers of the electroosmotic flow) and small organic compounds were injected into the column, driven under the application of voltage, and detected on the electropherogram. The proof of concept of applying porous membrane structure as stationary phase for CEC was shown and possible optimization to improve efficiency and selectivity was suggested.  相似文献   

18.
Zhu Y  Zhou C  Qin S  Ren Z  Zhang L  Fu H  Zhang W 《Electrophoresis》2012,33(2):340-347
A novel open‐tubular capillary electrochromatography (OT‐CEC) with modified core/shell magnetic nanoparticles coating as stationary phase was introduced using external magnetic force to fix magnetic nanoparticles. The magnetic nanoparticles coating inside the capillary columns could be easily regenerated by removing and re‐applying the external magnetic field. Magnetic field intensity, concentration and flow rate of nanoparticles suspension were investigated to achieve simple and stable preparation. Mixture of five organic acids was used as the marker sample to evaluate the OT‐CEC system, and the relative column efficiency of anthranilic acid reaches 220 000 plates/m. The excellent within‐column and between‐column repeatability has been testified with the RSDs of retention time of less than 1.51 and 5.29%, respectively. The aqueous extract of rhizoma gastrodiae was analyzed by the OT‐CEC system, and 23 peaks were eluted in 30 min. Compared with conventional open‐tubular capillary column, this new system shows faster separation speed and higher column efficiency from the larger surface area of nanoparticles. It has great potential in the method development for the analysis of complex samples, since magnetic coating can effectively prolong the column life by expediently replacing stationary phase to eliminate the pollution or irreversible adsorption.  相似文献   

19.
Summary Capillary electrochromatography (CEC) is classed as a hybrid technique between CE and HPLC and it combines the advantages of both these techniques. However, in some cases the disadvantages are also brought to light and some of these are difficult to resolve. For example the analysis of basic compounds using CEC. The problems of tailing peaks during HPLC analysis of basic compounds was resolved by end capping the residual silanol groups, but in CEC these are the groups that generate the electroosmotic flow. The analysis of basic compounds is crucial within the pharmaceutical industry where a high percentage of the drug actives are basic. Specially designed Continuous Beds stationary phases (CB) can mean that each application can have a specific stationary phase. In order to overcome the problem associated with the analysis of basic compounds using electrochromatography, we have designed a CB stationary phase with a positive charge, which could be operated using negative voltage. The resulting chromatography showed almost gaussian peaks for bases like nortriptyline which tail significantly using stationary phase typically used in CEC.  相似文献   

20.
Conductivity detection is applied to ion-exchange capillary electrochromatography (IE-CEC) with a packed stationary phase, using a capacitively coupled contactless conductivity detector with detection occurring through the packed bed. Columns were packed with a polymeric latex-agglomerate anion-exchanger (Dionex AS9-SC). A systematic approach was used to determine suitable eluants for IE-CEC separations using simultaneous indirect UV and direct conductivity detection. Salicylate and p-toluenesulfonate were identified as potential eluant competing anions having sufficient eluotropic strength to induce changes in separation selectivity, but salicylate was found to be unsuitable with regard to baseline stability. It was also found for both indirect UV and direct conductivity detection that homogenous column packing was imperative, and monitoring of the baseline could be used to assess the homogeneity of the packed bed. Using a p-toluenesulfonate eluant, the separation of eight common anions was achieved in 2.5 min. Direct conductivity detection was found to be superior to indirect UV detection with regard to both baseline stability and detection sensitivity with detection limits of 4-25 microg/L being obtained. However, the calibration for each anion was not linear over more than one order of magnitude. When using conductivity detection, the concentration of the eluant could be varied over a wider range (2.5-50 mM p-toluenesulfonate) than was the case with indirect UV detection (2.5-10 mM), thereby allowing greater changes in separation selectivity to be achieved. By varying the concentration of p-toluenesulfonate in the eluant, the separation selectivity could be manipulated from being predominantly ion-exchange in nature (2.5 mM) to predominantly electrophoretic in nature (50 mM).  相似文献   