首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
A method using high-performance liquid chromatography (HPLC) with UV absorption detection was developed to monitor stevioside in soju, a distilled spirits product that is commercially available. The method uses a single-step dilution for sample preparation. It completely eliminates the time-consuming process of solid-phase extraction. A method using HPLC/mass spectrometry was optimized to confirm the identities of stevioside and other related impurities, including rebaudioside A, rebaudioside C, and dulcoside. The method was validated. The validation parameters included range (10.1-1007.3 ppm), precision, linearity, accuracy, robustness, system suitability, and intermediate precision. Stevioside standard solutions at 6 concentration levels were prepared for the validation work, including the tests for precision, linearity, and accuracy. The solutions were prepared in triplicate for each concentration. The relative standard deviation for the precision test was <3% for all 6 concentration levels. The correlation coefficient for the linearity within the concentration range was determined to be > 0.999. The average recovery ranged from 95.7 to 101.1% for the soju samples spiked with stevioside standard. The detection limit for stevioside was estimated at 75 ppb. The method was used to screen several soju samples; no detectable stevioside was found in the samples.  相似文献   

4.
5.
6.
The metabolism and urinary excretion of a 100 mg dose of the non-sedating anxiolytic drug buspirone was examined using high-performance liquid chromatography/electrospray ionization mass spectrometry in the positive ion mode. In addition to a significant proportion of unchanged buspirone we were able to detect three major metabolite classes. These were identified as monohydroxy, dihydroxy and dihydroxymethoxy products. Detection of the metabolites and the parent drug was possible in all the urine samples collected (1-12 h) post-administration.  相似文献   

7.
Tripamide is a drug widely used in clinical practice for the treatment of hypertension and edema. This work evaluated a screening method for Tripamide and its urinary metabolites in human urine, using high-performance liquid chromatography diode-array detection (HPLC/DAD). Identification of these metabolites was investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) after dosing with 15 mg Tripamide. Acid hydrolysis showed that Tripamide is conjugated in the body. Two suspected metabolites were detected by HPLC/DAD. HPLC/ESI-MS/MS analysis suggested that these metabolites were probably hydroxylated together with loss of the -NH(2) group and dehydrogenation. These results will be useful in confirmation methods for Tripamide in doping control.  相似文献   

8.
Flavonoid profiling of a soybean sample has been performed by liquid chromatography/positive electrospray tandem mass spectrometry (LC/ESI(+)-MS/MS) using a quadrupole-linear ion trap (QLIT) instrument with an information-dependent data acquisition (IDA) protocol that looped, in a single run, an enhanced MS scan and an enhanced product ion scan. As compromise between time and obtainable information, spectra acquisition was split into two distinct runs: 220-450 Th and 400-800 Th, respectively. The isoflavones daidzein and genistein were identified as aglycones, monoglycosides, diglycosides, triglycosides, acetylglycosides, malonylglycosides, malonyl diglycosides, and dimalonyl diglycosides, whereas glycitein triglycosides, acetylglycosides, and dimalonyl diglycosides were not detected. Also kaempferol di- and triglycosides, malonylglycosides and malonyl diglycosides, previously reported in soy leaves and pods, and four naringenin malonylglycosides were identified.  相似文献   

9.
A reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and compared with a gas chromatography/mass spectrometry (GC/MS) method for determining butylated hydroxytoluene (BHT) in foodstuffs as a result of migration from plastic packaging. Similar extraction procedures were used in both methods. BHT was quantitated using an external standard in the HPLC method and an internal standard in the GC/MS method. Both methods presented good linearity (r(2) > or = 0.9917) and low detection limits. Recoveries obtained with the HPLC method (chicken meat, 95.8%, and Gouda cheese, 83.9%) were better than with the GC/MS method (chicken meat, 85.6%, and Gouda cheese, 71.3%).  相似文献   

10.
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism.  相似文献   

11.
A congener-specific method based on high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ES-MS/MS) in the negative ion mode was developed for the analysis of hexabromocyclododecane (HBCDD). On a C(18) analytical column, with a methanol/water mobile phase, the alpha-isomer was completely resolved from the beta- and gamma-isomers while the beta- and gamma-isomers were sufficiently resolved at half their peak heights. The ES spray voltage strongly influenced the intensity of the ion signal. For MS, a source temperature of 500 degrees C and a collision energy of 50 eV were found to be optimum for the [M-H](-) to Br(-) transition. Run-to-run and day-to-day (n = 3) variability was minimal, with relative standard deviations of 2.6-4.1 and 2.4-4.4%, respectively. The limit of detection was 4-6 pg on-column. When applied to tissue samples from Lake Winnipeg fish both alpha- and gamma-isomers of HBCDD were found in low-ng/g (lipid corrected) concentrations.  相似文献   

12.
A newly developed high-performance liquid chromatography/mass spectrometry (HPLC/MS) method has been successfully used to analyze plasma concentrations of various phytosterols (cholestanol and beta-sitosterol) and cholesterol metabolites (desmosterol and lathosterol). This was based on an unusual solvent combination of water/methanol vs. methanol/acetone/n-hexane applied on a Purospher Star RP-18e (125 x 2 mm, 3 microm) column, which proved excellent for the separation, identification and quantification of plasma sterols. Simple solid-phase extraction preparation of plasma samples was performed, followed by the developed fast and robust HPLC separation. Results on four groups of people were compared, those with low, normal and high plasma cholesterol levels and those with high cholesterol levels on statin therapy, and the results were evaluated using linear discriminant analysis (LDA). Variable selection for LDA was achieved using backward removal selection. Highly discriminatory variables were the ratios of desmosterol to sitosterol and of lathosterol to total plasma cholesterol. The latter ratio was also excellent for distinguishing subjects on statin therapy. The success rate of classification was 100%. The present pilot study shows the potential of HPLC/MS analysis and chemometrics for studying cholesterol-related disorders and warrants future full-scale medical study.  相似文献   

13.
14.
15.
16.
A confirmatory method coupling liquid chromatography to tandem mass spectrometry (LC/MS/MS) is described for the determination of tetracycline, oxytetracycline, doxycycline and chlortetracycline in honey. Demeclocycline, another tetracycline molecule not reported for its usage in honey, was used as internal standard to quantify the four analytes. The sample preparation entails a clean-up on an Oasis HLB solid-phase extraction cartridge and analyses were realised by LC/MS/MS in selected reaction monitoring mode. The stability of tetracyclines was checked under various storage conditions at -20, +4 and +20 degrees C (both under dark and light exposures). Indeed, tetracyclines are not stable molecules and the epimerisation phenomenon was evaluated in this work. Appropriate correction factors of the MS/MS responses of each epimer were studied for each of the four tetracyclines to accurately quantify them. Moreover, the matrix effects encountered during the LC/MS/MS analyses were also studied in spiked experiments from blank honey samples of various geographical origins and different flower types.  相似文献   

17.
We describe a novel two-dimensional liquid chromatography (2D-LC) method for fast and robust isolation and concentration of low abundant carbohydrates (sorbitol, glycerol) from biological matrices (plasma and urine). Off-line pre-purified fractions, enriched by analyte of interest, were analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS-MS). Initial 2D-LC automated sample pre-purification improved MS detection, eliminated matrix effects, and achieved high sensitivity (picogram detection limit) with a 6 min runtime and increased column lifetime. Using this method we have analyzed more than 1300 samples from biological matrices without column replacement.  相似文献   

18.
The review discusses the pitfalls of the matrix effect in mass spectrometry detection hyphenated to liquid chromatography separation. Matrix effect heavily influences both qualitative and quantitative analyses, giving rise to suppression or enhancement of the signal. As generally recognised, the predominant cause is the presence of undesired components that co-elute in the chromatographic separation and alter the ionisation process. The interfering species can be components of the sample, compounds released during the pre-treatment/extraction process or reagents added to the mobile phase to improve chromatographic resolution. The different mechanisms proposed in literature to explain the suppression or the enhancement of the signal both in electrospray and atmospheric pressure chemical ionisations are presented and the results observed in the different experimental conditions are compared and discussed. All data together lead to conclude that the chemical properties of the target analyte, the kind of matrix, the matrix to analyte concentration ratio, the extraction process, the chromatographic conditions as well as the kind of the mass spectrometry instrumentation and the ionisation conditions can play a role. Likely all these potential causes act in a synergic way and the final effect observed is hardly due to only one of them. Depending on an unpredictable combination of conditions, signal suppression or enhancement can be observed. The review discusses the matrix effects observed in HPLC–MS and HPLC–MS/MS analysis proposes hypotheses to explain the observed behaviours and proposes methods and strategies to overcome the matrix effects.  相似文献   

19.
Five metal complex azo compounds were analyzed using negative-ion electrospray ionization mass spectrometry (ESI-MS). Mass spectra of all compounds yield intense peaks corresponding to [M - H](-) ions without any fragmentation, where M denotes the neutral compound with a proton as the counterion. Under collision induced dissociation (CID) conditions, structurally important fragment ions were studied using the ion trap analyzer with a multistage mass spectrometry (MS(n) facility. Synthesized compounds with (15)N atoms in the azo group facilitated the fragmentation pattern recognition. A reversed-phase high-performance liquid chromatography (HPLC) method using 5 mM ammonium acetate in 70% aqueous acetonitrile as mobile phase was developed making possible the separation of all complex compounds tested. The lower detection limits of the ESI-MS method are in the range 10-20 ng of each compound. The HPLC/ESI-MS method makes possible the monitoring of ligand exchange in aqueous solutions of metal complex azo dyes, and also investigation of the stabilities of the complexes in solution. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

20.
Aspartame is a widely used sweetener,the long-term safety of which has been controversial ever since it was accepted for human consumption.It is unstable and can produce some harmful degradation products under certain storage conditions.A high-performance liquid chromatography/tandem mass spectrometry method was developed for the simultaneous analysis of aspartame and its four degradation products,including aspartic acid,phenylalanine,aspartyl-phenylalanine and 5-benzyl-3,6-dioxo-2-piperazieacetic acid in water and in diet soft drinks.Aspartame and its four degradation products were quantified by a matrix matched external standard calibration curve with excellent correlation coefficients.The limits of detection were 0.16–5.8 mg/L,which exhibited higher sensitivity than common methods.This method was rapid,sensitive,specific and capable of eliminating matrix interferences.It was also applied to the study of the degradation of aspartame at various pH and temperatures.The results indicated that aspartame was partly degraded under strong acidic or basic conditions and the extent of degradation increased with increasing temperature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号