首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 612 毫秒
1.
A cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) method has been developed and validated for purity determination of two bile acids, ursodeoxycholic acid (UDCA) and deoxycholic acid (DCA). Quantitation of related impurities such as lithocholic acid (LCA), chenodeoxycholic acid (CDCA), cholic acid (CA), and DCA in UDCA and CA in DCA was performed. A running buffer containing 20 mM borate-phosphate, 50 mM sodium dodecyl sulfate (SDS), 2.0 mM beta-cyclodextrin, and acetonitrile was used. Modifiers were added to improve resolution and selectivity. The applied voltage was 25 kV and detection was performed at 185 nm. Validation parameters such as selectivity, linearity, repeatability, intermediate precision, limit of detection, limit of quantitation, and robustness were evaluated. The method was simple and proved to be useful for the purity testing of bile acids in bulk drugs. Good results were obtained for related impurities at concentration levels from 0.05 to 1.5% with respect to the main component, according to international requirements.  相似文献   

2.
The potential of micellar electrokinetic chromatography (MEKC) for the profiling of cocaine samples is described. An MEKC system containing sodium dodecyl sulfate (SDS) and methanol was optimized using a test mixture of cocaine, its common impurities (benzoylecgonine, norcocaine, tropacocaine, and trans-cinnamoylcocaine), and several degradation products. The effect of pH, percentage modifier, and concentration surfactant on the separation has been investigated. The optimal separation buffer for cocaine samples consisted of 75 mM SDS, 17.5% methanol, and 25 mM borate (pH 8.3) and was well suited to separate components of diverse polarity in one run. Various cocaine seizures have been analyzed with the MEKC system and their signatures were compared. The electrokinetic chromatograms obtained were characteristic, and differences and similarities among the samples could easily be observed. Several impurities were identified in the samples by means of migration times and comparison of recorded and library UV spectra. The composition of the samples was determined semiquantitatively using relative corrected peak areas.  相似文献   

3.
This paper describes the characterization of procyanidin mixtures by acid depolymerization in the presence of cysteine (thiolysis with cysteine) and micellar electrokinetic chromatography (MEKC). Reversed-phase liquid chromatography (RP-HPLC) and MEKC were investigated for the separation of the major components of the depolymerized mixtures (catechins and their cysteinyl derivatives). The solutes could only be effectively separated using MEKC. Two background electrolytes (BGEs) are recommended: (i) 50 mM phosphate at pH 7, containing 40 mM sodium cholate (SC) and 10 mM sodium dodecyl sulfate (SDS); (ii) a BGE with the same composition but containing only 50 mM SDS. The MEKC procedures here reported, are cheap, reliable and fast, and their potential in the determination of the size and composition in procyanidin mixtures has been shown. The proposed MEKC methods were validated by comparison with our intralaboratory reference RP-HPLC method using cysteamine as thiol donor.  相似文献   

4.
A previously developed high-performance liquid chromatography method combined with pulsed amperometric detection allowed to separate many impurities of paromomycin. However, due to the presence of ion pairing agents and sodium hydroxide in the mobile phase, direct coupling to mass spectrometry for the identification of the chemical structures of the impurities was not an option. Indeed, ion suppression was encountered by trifluoroacetic acid and pentafluoroproponic acid in the mobile phase. A cation self-regenerating suppressor, which was originally designed for increasing analyte conductivity of ammonia and amines analysis in ion chromatography, was coupled between the liquid chromatography and ion trap-time of flight-mass spectrometry and almost all trifluoroacetic acid and pentafluoroproponic acid in the mobile phase was removed. The limit of detection of paromomycin in this integrated system improved significantly to 20 ng/ml (0.4 ng). The chemical structures of 19 impurities were elucidated and seven impurities were reported for the first time.  相似文献   

5.
A cyclodextrin-modified micellar electrokinetic chromatographic (CD-MEKC) method for the determination of the most important potential impurities of methotrexate (MTX): 2,4-diamino-6-(hydroxymethyl)pteridine, aminopterine hydrate, 4-[N-(2-amino-4-hydroxy-6-pteridinylmethyl)-N-methylamino] benzoic acid, 4-[N-(2,4-diamino-6-pteridinylmethyl)-N-methylamino] benzoic acid, and the distomer D-MTX is presented. The MEKC separation of these compounds was optimized by applying a step-by-step approach. The addition of beta-CD to a conventional MEKC system, based on sodium dodecyl sulfate (SDS) as surfactant, showed to be essential for the enantioresolution of racemic MTX as well as for the separation of the achiral impurities. To achieve high-resolution factor between the peaks adjacent to the main component (L-MTX), as required in the analysis of related impurities, the separation conditions were stressed; in particular, the addition of methanol to the CD-MEKC system resulted in a very effective choice. Under the optimized final conditions (100 mM SDS and 45 mM beta-CD in a mixture of 50 mM borate buffer, pH 9.30-methanol (75:25 v/v)), the method was validated showing a general adequate accuracy (93-106% recovery) in the determination of L-MTX related substances at the impurity level of 0.12% w/w with a relative standard deviation (RSD)% lower than 8% (n = 4). The method was successfully applied to the analysis of pharmaceuticals (tablets and injections) which showed to contain the distomer D-MTX as major impurity and aminopterine hydrate as a further related substance in the commercial tablets.  相似文献   

6.
Oligomeric procyanidins are potent antioxidant polyphenols of potential interest as disease-preventing agents. Their efficiency depends on the size and composition of their oligomeric structures. The mean degree of polymerization of these compounds is usually estimated by thiolysis with thiol-alpha-toluene followed by analysis using high-performance liquid chromatography (HPLC). We show the development of a mixed micellar electrokinetic chromatography (MEKC) method for the separation of the major components obtained after thiolysis with cysteamine (catechins and their cysteamine conjugates). MEKC studies using sodium dodecyl sulfate (SDS as pseudostationary phase led to long migration times, e.g., with 100 mM SDS, at pH 7, the solutes were separated in about 40 min), while the use of sodium cholate (SC) produced an elution window relatively short. Using a mixed micellar SC-SDS system (50 mM phosphate at pH 7 containing 40 mM SC and 10 mM SDS), it is possible to separate these compounds in less than 15 min. The proposed method is useful to separate the major components of the thiolysate in effluents from food processing (e.g., skins and seeds from grape and apple) considered as potential procyanidin sources.  相似文献   

7.
An efficient micellar electrokinetic chromatography (MEKC) method has been developed for the analysis of nine anthraquinones and bianthrones in rhubarb. A chemometric approach was used to search for the optimum conditions of separation. Those factors which were found to be significant with a screening design were further optimized with a central composite face-centered (CCF) design. Acetonitrile concentration was found to be the most influential, not only in resolution, but also in analysis time and peak asymmetry. With the optimized conditions: 15 mM sodium tetraborate/15 mM sodium dihydrogenphosphate buffer, 30 mM sodium deoxycholate, pH 8.6, 17 vol.% acetonitrile and 28 kV, nine tested analytes were baseline-separated within 14 min. The method was validated to analyze the rhubarb material. Solid-phase extraction (SPE) was manipulated to remove interfering substances. Five anthraquinones and two glycosidic bianthrones were detected and quantificated. The method should be suitable for determining these major active principles in rhubarb crude drugs.  相似文献   

8.
建立了以铁氰化钾测定头孢噻肟钠的分光光度法。 在0.20 mol/L NaOH溶液中,头孢噻肟钠(CTX)于100 ℃水浴中降解生成的巯基化合物能将Fe(Ⅲ)(pH=3.0)还原为Fe(Ⅱ),根据Fe(Ⅱ)与K3[Fe(CN)6]反应生成可溶性普鲁士蓝(KFeⅢ[FeⅡ(CN)6])的吸光度,可以间接测定头孢噻肟钠的含量。 头孢噻肟钠在0.040~24 mg/L范围内与吸光度(A)呈线性关系,线性回归方程:A=0.05088+0.2166ρ(mg/L),相关系数R=0.9986,检出限为0.01 mg/L,相对标准偏差(RSD)为1.36%(n=11),表观摩尔吸光系数ε=2.3×105 L/(mol·cm)。 此方法可用于药物及血清中头孢噻肟钠含量的测定。  相似文献   

9.
One micrometre silica particles, derivatized with C18, were electrokinetically packed into a 75-microm-i.d. capillary. The resulting column was evaluated for the separation of trimethoprim (TMP) and its impurities using pressurized capillary electrochromatography (pCEC), starting from a capillary liquid chromatographic (CLC) separation. These samples require gradient elution when separated by high performance liquid chromatography (HPLC), but with the new columns isocratic elution suffices for their separation by CLC or pCEC. Only 70,000 theoretical plates/m for impurity C were achieved using CLC mode at relative low pressure (78 bar) although very small particles were utilized. When a voltage above 2 kV (50 V/cm) was applied, unknown peaks appeared, which was assumed due to an electrophoretic effect with the unknown peaks resolving as a result of the applied voltage. In order to minimize these unfavorable contributions, only a low voltage was applied, still leading to higher separation performances and shorter separation times than in CLC. The optimal analyzing conditions in pCEC included a pressure of 78 bar, an applied voltage of 1 kV, and a mobile phase consisting of 80 mM sodium perchlorate (pH 3.1)/methanol (60/40, v/v). These conditions were used to separate and quantify four major impurities in TMP within 22 min. The obtained calibration curves were linear (r>0.9980) in concentration ranges between 0.005 and 0.1 mg/mL for impurities A and C; 0.02 and 0.10 mg/mL for impurity F; and 0.01 and 0.10 mg/mL for impurity H. The detection limits (S/N=3) for impurities A, C, F, and H were 0.52, 0.84, 3.18, and 2.41 microg/mL, respectively. The calibration curves were successfully applied to analyze spiked bulk samples, with mean recoveries ranging from 92% to 110%. The developed method can therefore be considered simple, rapid, and repeatable.  相似文献   

10.
This paper describes the development and validation of a microemulsion liquid chromatography (MELC) method for simultaneous determination of perindopril tert-butylamine and its impurities in bulk active substances and the pharmaceutical dosage form of tablets. An appropriate resolution with reasonable retention times was obtained for a microemulsion containing 0.24% (w/v) butyl acetate, 0.30% (w/v) ethyl acetate, 2% (w/v) sodium dodecyl sulfate, 7.75% (w/v) n-butanol, and 20.0 mM potassium dihydrogen phosphate, the pH of which was adjusted to 3.70 with 85% orthophosphoric acid. Separations were performed on a Nucleosil 120-5 butyl modified (C4), 250 x 4 mm, 5 microm particle size silica column at 40 degrees C, with a mobile phase flow rate of 1.25 mL/min. UV detection was performed at 254 nm. The established method was subjected to method validation, and required validation parameters were defined. Robustness testing, an important part of method validation, was performed as well. Since robustness validation can be conducted using different experimental designs, the Plackett-Burman design was applied due to its possibility of testing many factors at the same time. The validated MELC method was found to be suitable for the simultaneous determination of perindopril tert-butylamine and its impurities in pharmaceuticals.  相似文献   

11.
A sensitive high-performance liquid chromatography (HPLC) impurity profile method for the antibiotic ertapenem is developed and subsequently validated. The method utilizes an Inertsil phenyl column at ambient temperature, gradient elution with aqueous sodium phosphate buffer at pH 8, and acetonitrile as the mobile phase. The linearity, method precision, method ruggedness, limit of quantitation, and limit of detection of the impurity profile HPLC method are found to be satisfactory. The method is determined to be specific, as judged by resolving ertapenem from in-process impurities in crude samples and degradation products that arise from solid state thermal and light stress, acid, base, and oxidative stressed solutions. In addition, evidence is obtained by photodiode array detection studies that no degradate or impurity having a different UV spectrum coeluted with the major component in stressed or unstressed samples. The challenges during the development and validation of the method are discussed. The difficulties of analyzing an unstable active pharmaceutical ingredient (API) are addressed. Several major impurities/degradates of the API have very different UV response factors from the API. These impurities/degradates are synthesized or prepared by controlled degradation and the relative response factors are determined.  相似文献   

12.
Biologically active compounds with heteroaromatic ring system of cefotaxime sodium have been synthesized via aminomethylation reaction. The aminomethylation of cefotaxime sodium with various biologically potent sulphonamides/secondary amines was carried out and then characterized by elemental analysis and spectral studies – IR, 1H NMR, 13C NMR, Powder X-ray diffraction and Scanning Electron Microscopy. The compounds were screened for their antibacterial activity against various pathogenic bacteria at varying concentrations. The antibacterial activity of cefotaxime sodium derivatives was compared with parent sulphonamides. The toxicity of synthesized cefotaxime sodium derivatives was ascertained by LD50 test.  相似文献   

13.
裘亚  秦峰  闻宏亮  赵敬丹  刘浩  杨美成 《色谱》2015,33(12):1314-1319
建立了在线二维液相色谱-四极杆飞行时间质谱检测头孢噻吩钠杂质谱的方法,有效地解决了流动相中含不挥发性磷酸盐的色谱系统不适合用于液相色谱-质谱快速鉴定杂质的难题。一维高效液相色谱(HPLC)以Symmetry C18为色谱柱,以磷酸盐缓冲液(pH 2.5)和乙腈梯度洗脱;二维以ACQUITY UPLC BEH C18为色谱柱,以0.1%(v/v)甲酸水溶液和0.1%(v/v)甲酸乙腈溶液梯度洗脱。以HLB C18为捕集柱,用0.1%(v/v)甲酸水溶液进行捕集和脱盐,采用正离子模式采集数据。对头孢噻吩钠中6个杂质进行了结构鉴定,对其来源进行了分析,并进一步确证了《中国药典》2010年版对头孢噻吩钠杂质A认定有误。采用本方法可以快速、简便、灵敏地对头孢噻吩钠杂质谱进行检测。  相似文献   

14.
This work verifies the potential of CE in the analysis of significant impurities of montelukast sodium - an active ingredient for the treatment of bronchial asthma. Using 20 mM borate buffer pH 9.2 with 10 mM SDS and 10 mM (2-hydroxypropyl)-gamma-CD (2HP-gamma-CD) it was possible to separate montelukast and several impurities, including its cis-isomer, after exposure to light and oxygen. The obtained method surpasses a chromatographic method for montelukast sodium in terms of time of analysis (9 min of CE analysis vs. 35 min HPLC) and efficiency (CE offered over 900 000 theoretical plates for montelukast). Good repeatability of the method was supported by the low % RSD for the migration time of montelukast (0.53%). For the first time, the capillary electrophoretic method was employed for temporal study of the degradation of montelukast. The results showed that degradation of montelukast and the formation of the cis-isomer mainly occurred during the first 2 days of exposure, and occurred to a higher degree when there was no contact with the air (oxygen) in the exposed sample.  相似文献   

15.
The application of capillary electrophoresis for separation of penicillin V and its impurities was investigated. The phosphate-borate buffer supplemented with sodium dodecyl sulfate (SDS) 20.0 g/L (69 mM) and pentanesulfonic acid sodium salt (PS) 2.2 g/L (12.5 mM) adjusted to pH 6.3, and current voltage 15 kV seem to provide optimal conditions for this aim. The resolution between penicillin V and each impurity was very good. The statistical analysis of phenoxymethylpenicillin V assay showed no significant differences between the results obtained by CE and HPLC methods.  相似文献   

16.
Four major bilirubin species in serum were separated by micellar electrokinetic chromatography with 25 mM sodium dodecyl sulfate (SDS) and 20 mM sodium tetraborate-boric acid buffer at pH 8.5. Due to the solubilization of the serum proteins by the SDS micelles, serum samples were injected directly into a 50 cm x 75 microns I.D. fused-silica capillary and complete separation of the four bilirubin species was accomplished within ca. 10 min without extensive sample pretreatment. Detection was performed by absorbance at 450 nm and average limit of detection was in the 6.0 microM concentration range. The usefulness of this method was demonstrated for the separation and detection of a number of bilirubin species present in pathological human serum samples.  相似文献   

17.
A stability indicating capillary electrophoretic method for separation and determination of cetirizine dihydrochloride and its major impurities in bulk and a tablet dosage form was developed. The electrophoretic separation was performed in an uncoated fused-silica capillary (75 cm × 50 μm i.d.) using 75 mM sodium phosphate (pH 2.8) as background electrolyte, with an applied voltage of +25 kV at 25°C and UV detection at 230 nm. Fexofenadine was used as internal standard. The proposed method was found selective for determination of the main drug and its major impurities. The regression data obtained from the calibration plots indicated linear relationship (r 2 = 0.998) over the concentration range of 40–240 μg/mL of cetirizine. Repeatability and reproducibility of the method, assessed as intra-day and inter-day variation and expressed as RSD (%), were 1.3 and 2.6, respectively. Stress tests on cetirizine under acidic, basic, oxidative and heat incubating at 80°C conditions revealed that no major compound was formed under the applied conditions and the proposed CE method is applicable for stability studies on cetirizine. Then, the method was successfully applied to the determination of cetirizine in bulk and a tablet dosage form.  相似文献   

18.
The separation of tylosin by micellar electrokinetic capillary chromatography with a mixed micelle system is described. Good selectivity was obtained with sodium phosphate buffer (80 mM, pH 7.5) containing 20 mM sodium cholate and 7 mM cetyltrimethylammonium bromide (CTAB). This method permits tylosin to be separated from its closely related substances within 15 min. The influences of type of buffer, buffer pH, the concentrations of sodium cholate and CTAB were investigated. The robustness of the method was examined for tylosin by means of a full-fraction factorial design. Quantitative results are presented. Using a similar buffer system (80 mM sodium phosphate, pH 6.0, 20 mM sodium cholate and 5 mM CTAB), separation of erythromycin and its main related substances was also obtained. However, detection sensitivity and resolution are not sufficient for analysis of related substances in erythromycin commercial samples.  相似文献   

19.
A method was proposed for the simultaneous determination of steroids of the endo- and exogeneous origin with the use of micellar electrokinetic chromatography, which provides the determination of residual medicines in biological fluids and the control of medication efficiency at different steroidogenesis abnormalities. The introduction of a macrocyclic addition of β-cyclodextrin (from 1 to 6 mM) into a buffer electrolyte solution (25 mM phosphoric acid, 20 mM sodium dodecyl sulfate, 4.5 mM urea, pH 2.5) or into a sample solution decreases the detection limit by a factor of 20–200.  相似文献   

20.
A method based on RP-HPLC with indirect UV detection was developed for the determination of phosphates and phosphites as impurities in sodium risedronate. RP separation of the phosphates and phosphites was achieved by adding tetrabutylammonium hydroxide as an ion-pairing agent in the mobile phase. Potassium hydrogen phthalate was added to the mobile phase as an ionic chromophore in order to obtain high background absorption of the mobile phase. Separation was performed on a C18 column using a mixture of pH 8.2 buffer (containing 0.5 mM tetrabutylammonium hydroxide and 1 mM phthalate) and acetonitrile (95 + 5, v/v) as the mobile phase, with indirect UV detection at 248 nm. The validation of the method included determination of specificity/selectivity, linearity, LOD, LOQ, accuracy, precision, and robustness. The LOD was 0.86 microg/mL for phosphates and 0.76 microg/mL for phosphites. The LOQ was 2.60 microg/mL for phosphates and 2.29 microg/mL for phosphites. The developed method is suitable for quantitative determination of phosphates and phosphites as impurities in QC of sodium risedronate.  相似文献   