首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Preparation and biological activity of the metabolites of the potent antihyperglycemic and antihyperlipidemic agent, (E)-4-(4-[(5-methyl-2-phenyl-1,3-oxazol-4-yl)methoxy]benzyloxyimino)-4-phenylbutyric acid (TAK-559) (1), were investigated. Metabolites M-I (2), M-II (3), M-III (4) and M-IV (5) were synthesized and their biological activities were evaluated by in vitro and in vivo experiments. Compounds 2-4 activate human peroxisome proliferator-activated receptor gamma one (hPPARgamma1) and hPPARalpha, but their activities are weaker than those of TAK-559 (1). Compound 5 only activates hPPARgamma1 weakly. TAK-559 (1) showed potent in vivo plasma glucose and triglyceride lowering activities in Wistar fatty rats after intraperitoneal administration, while its metabolites (2-5) showed comparatively weak activities.  相似文献   

2.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) based on selected reaction monitoring (SRM) is the standard methodology in quantitative analysis of administered xenobiotics in biological samples. Utilizing two SRM channels during positive electrospray ionization (ESI) LC/MS/MS method development for a drug compound containing two basic functional groups, we found that the response ratio (SRM1/SRM2) obtained using an acidic mobile phase was dramatically different from that obtained using a basic mobile phase. This observation is different from the well-established phenomenon of mobile phase affecting the [M+H](+) response, which is directly related to the amount of the [M+H](+) ions produced during the ionization. Results from follow-up work reported herein revealed that the MS/MS fragmentation patterns of four drug or drug-like compounds are affected not only by the pH, but also by the aqueous-organic ratio of the mobile phase and the buffer concentration at a given apparent pH. The observed phenomenon can be explained by invoking that a mixture of [M+H](+) ions of the same m/z value for the analyte is produced that is composed of two or more species which differ only in the site of the proton attachment, which in turn affects their MS/MS fragmentation pattern. The ratio of the different protonated species changes depending on the pH, aqueous-organic ratio, or ionic strength of the mobile phase used. The awareness of the mobile phase dependency of the MS/MS fragmentation pattern of precursor ions of identical m/z value will influence LC/MS/MS-based bioanalytical method development strategies. Specifically, we are recommending that multiple SRM transitions be monitored during mobile phase screening, with the MS/MS parameters used for each SRM optimized for the composition of the mobile phase (pH, organic percentage, and ionic strength) in which the analyte elutes.  相似文献   

4.
Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking‐water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high‐resolution MS data using a hybrid quadrupole time‐of‐flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co‐eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC‐MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
This paper describes the development and partial validation of a fast, sensitive and specific ultra-performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method for the determination of testosterone (T) and its four metabolites, 6beta-OH-T, 16alpha-OH-T, 16beta-OH-T and 2alpha-OH-T, in in vitro samples. The analytical method involves direct dilution of samples with acetonitrile containing an internal standard, followed by separation of testosterone and the four metabolites on an Acquity UPLCtrade mark C(18) column and detected by selected reaction monitoring (SRM) in positive ionization mode using turbo ionspray ionization. The parent compound and its metabolites investigated were well separated (Rs >1.5) with a run time of 4 min under a gradient condition. The method was partially validated. The linear concentration range was 0.01 to 5 microM for all the compounds of interest. Inter-assay mean bias and relative standard deviation (RSD) were in the range of -12% to 8% and 4.1% to 8.5%, respectively. Intra-assay mean bias and RSD were in the range of -8.0% to 5.2% and 3.4% to 9.6%, respectively. The lower limit of quantitation for this assay was 0.01 microM. The differences in LC/MS performance were investigated by conducting a comparison of UPLC with another method previously optimized for HPLC-based separation and quantification of testosterone and its metabolites.  相似文献   

6.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantification of opioids, cocaine, and metabolites in urine was developed and validated. A 10-microL aliquot of urine was injected directly onto the LC/MS/MS system. The lack of sample preparation substantially reduced total analysis time. Separation was performed by reversed-phase chromatography with gradient elution for all analytes in 26 min. Atmospheric pressure chemical ionization (APCI) was a rugged and efficient ionization technique for basic drugs. Identification and quantification was based on selected reaction monitoring (SRM). Calibration, with deuterated internal standards, was performed by linear regression analysis (weighting factor 1/x). Limits of quantitation (LOQ) were established between 10-100 ng/mL and linearity was obtained up to a maximum of 10 000 ng/mL with an average correlation coefficient (R(2)) > 0.99. Analytical validation criteria for specificity, precision, accuracy, dilution integrity, matrix effect, and stability were fulfilled. The method proved to be simple and time efficient, and was applicable for illicit drug use monitoring and methadone treatment compliance in clinical research projects at the National Institute on Drug Abuse (NIDA).  相似文献   

7.
BAPTA-AM is the acetoxymethylester of the calcium chelator BAPTA and has demonstrated efficacy in several animal models of cerebral ischemia. This paper describes the development of a method for the determination of BAPTA-AM in rat plasma by liquid chromatography/tandem mass spectrometry. Owing to multiple ester groups in the structure of BAPTA-AM, [M + Na](+) was chosen as the analytical ion for quantification of BAPTA-AM. During the analytical method development, a high percentage of organic solvent and the addition of an amount of sodium acetate and formic acid in the mobile phase were found to favor the sensitivity and reproducibility of [M + Na](+). Poor fragmentation was usually observed in the MS/MS spectra of sodium adduct ions. However, abundant and reproducible fragment ions were observed for the BAPTA-AM sodium adduct ion, and therefore the traditional selective reaction-monitoring mode was used to further improve the sensitivity of MS detection. Because of the lability of the ester bond, a combination of fluoride and hydrochloric acid was applied to minimize the enzymatic hydrolysis, and acetonitrile was chosen to avoid the chemical hydrolysis or solvolysis during the sample collection and preparation procedure. On the basis of these studies, a rapid, sensitive and reproducible method for the determination of BAPTA-AM in rat plasma, using LC/ESI-MS/MS and a simple protein precipitation procedure, was developed and validated. Also, the present method was successfully applied to the determination of BAPTA-AM plasma concentrations for pharmacokinetic studies in rats.  相似文献   

8.
MK-0767, 5-[2,4-dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)phenyl]methyl]benzamide (I, Table 1), is a dual peroxisome proliferator-activated receptor (PPAR) alpha/gamma agonist previously studied for the treatment of type 2 diabetes and dyslipidemia. To support further toxicological studies in one of the animal species used in chronic testing of I, a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantification of I and seven metabolites in rat urine was developed and validated. In this method, urine samples were diluted with acetonitrile/methanol (50:50, v/v) and injected directly onto the column of an LC system. Detection was achieved by MS/MS using a turbo ion spray probe monitoring precursor --> product ion combinations in selected reaction monitoring (SRM) mode. The linear range for I and three metabolites was 0.8-800 ng/mL, and 8-8000 ng/mL for four other metabolites found to be present in urine at higher concentrations than I. Intra-day and inter-day variation using this method were < or = 13.0%. The method exhibited good linearity, reproducibility, specificity and sufficient sensitivity when used for the analysis of rat urine samples. Concentrations of I and its major metabolites in rat urine were determined in samples collected between 0-24 h after dosing on the last day of administration of nine daily oral doses to three male (1000 mg/kg/day) and three female (300 mg/kg/day) Sprague-Dawley rats. The urinary concentrations of I and its metabolites were similar in male and female rats. The average concentrations of I were 0.51 and 0.33 microg/mL in male and female rats, respectively. Concentrations of four of the seven metabolites quantified were 6- to 45-fold higher than those of I. The most abundant metabolite, with concentrations of 24.2 and 13.3 microg/mL in male and female rat urine, respectively, was a methyl sulfoxide derivative formed by oxidative cleavage of the thiazolidinedione ring, followed by S-methylation and oxidation of the sulfide intermediate.  相似文献   

9.
Novel thiosemicarbazone metal chelators are extensively studied anti‐cancer agents with marked and selective activity against a wide variety of cancer cells, as well as human tumor xenografts in mice. This study describes the first validated LC‐MS/MS method for the simultaneous quantification of 2‐benzoylpyridine 4‐ethyl‐3‐thiosemicarbazone (Bp4eT) and its main metabolites (E/Z isomers of the semicarbazone structure, M1‐E and M1‐Z, and the amidrazone metabolite, M2) in plasma. Separation was achieved using a C18 column with ammonium formate/acetonitrile mixture as the mobile phase. Plasma samples were treated using solid‐phase extraction on 96‐well plates. This method was validated over the concentration range of 0.18–2.80 μM for Bp4eT, 0.02–0.37 μM for both M1‐E and M1‐Z, and 0.10–1.60 μM for M2. This methodology was applied to the analysis of samples from in vivo experiments, allowing for the concentration–time profile to be simultaneously assessed for the parent drug and its metabolites. The current study addresses the lack of knowledge regarding the quantitative analysis of thiosemicarbazone anti‐cancer drugs and their metabolites in plasma and provides the first pharmacokinetic data on a lead compound of this class. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Validated liquid chromatography/tandem mass spectrometric (LC/MS/MS) methods are now widely used for quantitation of drugs in post-dose (incurred) biological samples for the assessment of pharmacokinetic parameters, bioavailability and bioequivalence. In accordance with the practice currently accepted within the pharmaceutical industry and the regulatory bodies, validation of a bioanalytical LC/MS/MS method is performed using standards and quality control (QC) samples prepared by spiking the drug (the analyte) into the appropriate blank biological matrix (e.g. human plasma). The method is then declared to be adequately validated for analyzing incurred biological samples. However, unlike QC samples, incurred samples may contain an epimer or another type of isomer of the drug, such as a Z or E isomer. Such a metabolite will obviously interfere with the selected reaction monitoring (SRM) transition used for the quantitation of the drug. The incurred sample may also contain a non-isomeric metabolite having a molecular mass different from that of the drug (such an acylglucuronide metabolite) that can still contribute to (and hence interfere with) the SRM transition used for the quantitation of the drug. The potential for the SRM interference increases with the use of LC/MS/MS bioanalytical methods with very short run times (e.g. 0.5 min). In addition, a metabolite can potentially undergo degradation or conversion to revert back to the drug during the multiple steps of sample preparation that precede the introduction of the processed sample into the LC/MS/MS system. In this paper, we recommend a set of procedures to undertake with incurred samples, as soon as such samples are available, in order to establish the validity of an LC/MS/MS method for analyzing real-life samples. First, it is recommended that the stability of incurred samples be investigated 'as is' and after sample preparation. Second, it is recommended that potential SRM interference be investigated by analyzing the incurred samples using the same LC/MS/MS method but with the additional incorporation of the SRM transitions attributable to putative metabolites (multi-SRM method). The metabolites monitored will depend on the expected metabolic products of the drug, which are predictable based on the functional groups present in the chemical structure of the drug. Third, it is recommended that potential SRM interference be further investigated by analyzing the incurred samples using the multi-SRM LC/MS/MS method following the modification of chromatographic conditions to enhance chromatographic separation of the drug from any putative metabolites. We will demonstrate the application of the proposed strategy by using a carboxylic acid containing drug candidate and its acylglucuronide as a putative metabolite. Plasma samples from the first-in-man (FIM) study of the drug candidate were used as the incurred samples.  相似文献   

11.
A rapid, sensitive and selective method has been developed for the direct determination of ethephon residues in vegetables (apple, cherry and tomato). Given the anionic character of ethephon, the use of ion-pairing liquid chromatography (LC) in combination with tandem mass spectrometry (MS/MS, triple quadrupole) allowed its direct determination in these matrices avoiding a derivatisation step and favouring the automation of the method. Samples were extracted with a mixture of dichloromethane/aqueous formic acid (pH 3) (1:1). Then, tetrabutylammonium acetate (TBA) was added as an ion-pairing reagent, and an aliquot of the aqueous extract was directly injected into the LC/MS/MS system. Quantification was performed with matrix-matched standards prepared from blank sample extracts. MS/MS measurements were made in the selected reaction monitoring (SRM) mode, using the most sensitive transition (m/z 107 > 79) for quantification, and up to four additional transitions for confirmation. Quantitative recoveries were obtained for all matrices (between 83% and 96%) at two concentration levels tested (0.05 and 0.5 mg/kg), with relative standard deviations lower than 9% in all cases. The addition of TBA directly into the sample extract contained in the injection vial was found sufficient to obtain satisfactory LC retention for the analyte. Under these conditions, the absence of ion-pairing reagent in the mobile phase minimised the ionisation suppression for ethephon in the MS source, leading to an increase in the sensitivity of the method and reaching limits of detection of 0.02 mg/kg for all matrices investigated. The acquisition of five specific MS/MS transitions for ethephon allowed the simultaneous and reliable quantification and confirmation of the analyte in the samples.  相似文献   

12.
A simple, sensitive and selective high‐performance liquid chromatography electrospray ionization tandem mass spectrometry (LC‐MS/MS) method was developed for simultaneous determination and pharmacokinetic study of caffeic acid (CA) and its active metabolites. The separation with isocratic elution used a mobile phase composed of methanol and water (containing 0.1% formic acid) at a flow rate of 0.2 mL/min. The detection of target compounds was done in selected reaction monitoring (SRM) mode. The SRM detection was operated in the negative electrospray ionization mode using the transitions m/z 179 ([M ? H]?) → 135 for CA, m/z 193 ([M ? H]?) → 134.8 for ferulic acid and isoferulic acid and m/z 153 ([M ? H]?) → 108 for protocatechuic acid. The method was linear for all analytes over the investigated range with all correlation coefficients 0.9931. The lower limits of quantification were 5.0 ng/mL for analytes. The intra‐ and inter‐day precisions (relative standard deviation) were <5.86 and <6.52%, and accuracy (relative error) was between ?5.95 and 0.35% (n = 6). The developed method was applied to study the pharmacokinetics of CA and its major active metabolites in rat plasma after oral and intravenous administration of CA. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
The effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of drug molecules in liquid chromatographic/ionspray tandem mass spectrometric (LC/MS/MS) determination were evaluated for simvastatin (SV) and its hydroxy acid (SVA). The objective was to improve further the sensitivity for SV by overcoming the unfavorable condition caused by the formation of multiple major adduct ions and multiple major fragment ions when using ammonium as LC mobile phase buffer. Mobile phases (70:30 acetonitrile-buffer, 2 mM, pH 4.5) with buffers made from ammonium, hydrazine or alkyl (methyl, ethyl, dimethyl or trimethyl)-substituted ammonium acetate were evaluated. Q1 scan and product ion scan spectra were obtained for SV in each of the mobile phases under optimized conditions. The results showed that, with the alkylammonium buffers, the alkylammonium-adducted SV was observed as the only major molecular ion, while the formation of other adduct ions ([M + H](+), [M + Na](+) and [M + K](+)) was successfully suppressed. On the other hand, product ion spectra with a single major fragment ion were not observed for any of the alkylammonium-adducted SVs. The affinity of the alkylammoniums to SV and the basicity of the alkylamines are believed to be factors influencing the formation and abundance of molecular and fragment ions, respectively. Methylammonium acetate provided the most favorable condition among all the buffers evaluated and improved the sensitivity several-fold for SV in LC/MS/MS quantitation compared with that obtained using ammonium acetate buffer. Better precision for SV in both Q1 and SRM scans was observed when using methylammonium buffer compared with those using ammonium buffer. The mobile phase buffer contents did not seem to affect the ionization, fragmentation and chromatography of SVA. The results of this evaluation can be applied to similar situations with other organic molecules in ionspray LC/MS/MS determination.  相似文献   

14.
15.
Ding  Chenxu  Wang  Lingyun  Tian  Chunliang  Li  Yulin  Sun  Zhiwei  Wang  Honglun  Suo  Yourui  You  Jinmao 《Chromatographia》2008,67(11):893-903

A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL−1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.

  相似文献   

16.
Beclomethasone dipropionate (BDP) is a potent pro-drug to beclomethasone (BOH) and is used in the treatment of chronic and acute respiratory disorders in the horse. The therapeutic dose of BDP (325 microg per horse) by inhalation results in very low plasma and urinary concentrations of BDP and its metabolites that pose a challenge to detection and confirmation by equine forensic laboratories. To solve this problem, a method involving the use of a liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) was developed for the detection, confirmation and quantification of the analytes in equine samples. Ammonium formate or acetate buffer added to LC mobile phase favored the formation of [M + H](+) ions from BDP and its metabolites, whereas formic acid led to the formation of sodium and potassium adduct ions ([M + Na](+), [M + K](+)) together with [M + H](+) ions. Acetonitrile, on the other hand, favored the formation of abundant solvent adduct ions [M + H + CH(3)CN](+) with the analytes under electrospray ionization (ESI) and atmospheric pressure chemical ionization conditions. In contrast, methanol formed much less solvent adduct ions than acetonitrile. The solvent adduct ions were thermally stable and could not be completely desolvated under the experimental conditions, but they were very fragile to collision-induced dissociation (CID). Interestingly, these solvent adduct ions were observed on a triple-quadrupole mass spectrometry but not on an ion trap instrument where helium used as a damping gas in the ion trap might cause the solvent adduct ions desolvated by collision. By CID studies on the [M + H](+) ions of BDP and its metabolites, their fragmentation paths were proposed. In equine plasma at ambient temperature over 2 h, BDP and B21P were hydrolyzed in part to B17P and BOH, respectively, but B17P was not hydrolyzed. Sodium fluoride added to equine plasma inhibited the hydrolysis of BDP and B21P. The matrix effect in ESI was evaluated in equine plasma and urine samples. The method involved the extraction of BDP and its metabolites from equine plasma and urine samples by methyl tert-butyl ether, resolution on a C(8) column with a mobile phase gradient consisting of methanol and ammonium formate (2 mmol l(-1), pH 3.4) and multiple reaction monitoring for the analytes on a triple-quadrupole mass spectrometer. The detection limit was 13 pg ml(-1) for BDP and B17P, 25 pg ml(-1) for BOH and 50 pg ml(-1) for B21P in plasma and 25 pg ml(-1) for BOH in urine. The method was successfully applied to the analysis of equine plasma and urine samples for the analytes following administration of BDP to horses by inhalation. B17P, the major and active metabolite of BDP, was detected and quantified in equine plasma up to 4 h post-administration by inhalation of a very low therapeutic dose (325 microg per horse) of BDP.  相似文献   

17.
1-[(1R,2R)-2-(2,4-Difluorophenyl)-2-hydroxy-1-methyl-3-(1H-1,2,4-triazol-1-yl)propyl]-3-[4-(1H-1-tetrazolyl)phenyl]-2-imidazolidinone [(1R,2R)-1: TAK-456] is a new antifungal agent selected as a candidate for clinical trials. The three stereoisomers [(1S,2R)-, (1S,2S)- and (1R,2S)-1] of this compound were prepared as authentic samples to determine the enantiomeric and diastereomeric purity of TAK-456 as well as to compare their in vitro antifungal activity. Pharmacokinetic studies of TAK-456 using rats identified the existence of metabolites in the liver homogenate. The structures of the major metabolites were assigned as 4-hydroxy-2-imidazolidinone (3) and/or 5-hydroxy-2-imidazolidinone (4), based on HPLC and LC/MS/MS analyses. These hydroxylated compounds, 3 and 4, were prepared by reduction of the corresponding imidazolidinediones, 11 and 12, and confirmed to be identical to the metabolites by HPLC. In vitro antifungal activities of the three stereoisomers and the synthesized metabolites were considerably weaker than TAK-456.  相似文献   

18.
Bioanalytical support of plasma pharmacokinetic (PK) studies for drug discovery programs primarily involves the quantitative analysis of dosed compounds using liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/MS/MS) operated in selected reaction monitoring (SRM) mode. However, there is a growing need for information on the metabolism of new chemical entities (NCEs), in addition to the time-concentration profiles from these studies. In this paper, we present a novel approach to not only quantify parent drugs with SRM, but also simultaneously screen for metabolites using a hybrid triple quadrupole/linear ion trap (QqQ(LIT)) instrument. This was achieved by incorporating both the conventional SRM-only acquisition of parent compounds and the SRM-triggered information-dependent acquisition (IDA) of potential metabolites within the same scan cycle during the same LC/MS/MS run. Two test compounds were used to demonstrate the applicability of this approach. Plasma samples from PK studies were processed by simple protein precipitation and the supernatant was diluted with water before injection. The fast scanning capability of the linear ion trap allowed for the information-dependent acquisition of metabolite MS/MS spectra (<1 s/scan), in addition to the collection of adequate data points for SRM-only channels. The MS/MS spectra obtained from potential metabolites in post-dose samples correlated well with the spectra of the parent compounds studied, therefore providing additional confirmatory structure information without the need for repetitive analyses. Relative quantitative time-concentration profiles of identified metabolites were also obtained. Furthermore, this articulated SRM+SRM-IDA approach generated equivalent quantitative results for parent compounds to those obtained by conventional SRM-only analysis. This approach has been successfully used to support discovery PK screening programs.  相似文献   

19.
A sensitive, specific and accurate HPLC method for the quantification of rivastigmine (RSM) in rat urine was developed and validated. The method involves the simple liquid–liquid extraction of RSM and pyridostigmine as an internal standard (IS) from rat urine with tertiary methyl butyl ether. The chromatographic separation of RSM and IS was achieved with 20 mm ammonium acetate buffer (pH 6.5) and acetonitrile (65:35, v/v) delivered at flow‐rate of 1 mL/min on a Kromasil KR‐100. The method was in linear range from 50 to 5000 ng/mL. The validation was done as per FDA guidelines and the results met the acceptance criteria. The method was successfully applied for the quantification of RSM in rat urine. Besides method validation, we have identified two metabolites of RSM in urine. Both the metabolites were characterized by HPLC‐PDA and LC‐MS/MS and it was found that one metabolite is novel. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
HR011303 is a novel and highly selective urate transporter 1 (URAT1) inhibitor. In this study, a sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for quantification of HR011303 in beagle dog plasma. Plasma samples were pretreated with protein‐precipitation extraction by acetonitrile and added with a trifluoromethyl substituted analog of HR011303 as internal standard. The chromatographic separation was performed on a Shiseido C18 column (100 × 4.6 mm, i.d., 5 μm) by mobile phases consisting of 5 mm ammonium–formic acid (100:0.1) and acetonitrile–formic acid (100:0.1) solutions in gradient elution. The MS detection was conducted in electrospray positive ionization with multiple reactions monitoring at m/z 338 → 240 for HR011303 and m/z 328 → 230 for the internal standard using 25 eV argon gas collision induced dissociation. The established LC–MS/MS method showed good selectivity, sensitivity, precision and accuracy. The plasma pharmacokinetics of HR011303 in beagle dogs following both oral and intravenous administration were then successfully evaluated using this LC–MS/MS method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号