首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A determination procedure has been developed for210Bi and210Po in environmental samples and was applied for pine needles. Bismuth-210 and210Po separated from the parent nuclide210Pb as BiOCl precipitate were extracted simultaneously by TOPO/toluene containing PPO and POPOP. The separation of210Bi and210Po from210Pb was almost satisfactory. The activity of210Bi+210Po in the TOPO/toluene was measured periodically by liquid scintillation counting for about 20 days after separation. The time course of the decreasing pattern of the activity was determined by the initial activity ratio210Po/210Bi. The decreasing pattern of the activity was compared with theoretical patterns, and best estimates for210Po and210Bi were obtained by non-linear least-squares fitting. The activities of210Bi and210Po were determined for one-year and two-year old pine needles fro the same pine tree, and weathering half-time and deposition rate of these nuclides was discussed.  相似文献   

2.
 Measurement uncertainties in the determination of 210Pb and 210Po in Reference Material IAEA-300 (Baltic Sea Sediment) were evaluated. 210Pb and 210Po were separated from the matrix using an Sr resin column. The chemical yield of 210Pb was determined gravimetrically in PbSO4 form. Precipitation was followed by beta proportional counting after 210Bi ingrowth. 210Po was determined by alpha spectrometry after its spontaneous deposition on a Cu planchet. The major source of uncertainty was identified as the statistical counting uncertainty, which was also expected and is almost impossible to reduce without extension of the time required for an analysis. The expanded uncertainties were determined as 7.4% and 12.2% for 210Pb and 210Po, respectively. Received: 3 September 2002 Accepted: 3 December 2002 Acknowledgement This work was financially supported by Ministry of Education, Science and Sport, Republic of Slovenia (Project group PO-0106–0532). Presented at CERMM-3, Central European Reference Materials and Measurements Conference: The function of reference materials in the measurement process, May 30–June 1, 2002, Rogaška Slatina, Slovenia Correspondence to P. Vreˇcek  相似文献   

3.
A method for the separation of210Pb,210Bi and210Po using spontaneous deposition has been developed. The210Bi and210Po are simultaneously removed by deposition onto nickel foil (copper and tin could also be used but less effectively) while the210Po is separated from210Bi, after dissolution of the nickel foil, by deposition onto silver foil. The effectiveness of each separation was evaluated by adding aliquot portions of each solution to a cocktail and counting with a liquid scintillation counter. Water was used as the medium to observe the Cherenkov count of the sample solution.  相似文献   

4.
A method for210Po and210Pb determination in water samples is described. The nuclides are concentrated, in presence of added208Po and lead carrier, by evaporation. Then the polonium is plated electroless from the acidic solution on a copper planchet and measured by alpha spectrometry.210Pb separation from the other isotopes is based on the solutility of PbSO4 in citrate.210Pb content is determined by measuring the activity of its daughter210Bi. The critical steps in the isolation of lead have been examined and discussed.  相似文献   

5.
Methodologies for the quantification of measurement uncertainties associated with the determination of 210Pb- and 210Po-specific activities by liquid scintillation counting (LSC) and alpha-particle spectrometry are presented, and are demonstrated using the soil reference material IAEA-326. Major contributors to the combined uncertainty associated with the measurement result of 210Pb were the uncertainties of net count rates in the 210Pb energy region of the sample spectrum and in the 210Bi energy region of the blank spectrum. The predominant sources of uncertainty in the measurement of 210Po were the uncertainties of net count rates in the regions of interest of 209Po and 210Po. The relative standard uncertainty of 210Po exponentially increases with the time interval between the sampling date and the separation date of Po, and this effect is strongly dependent on the 210Po/210Pb activity ratio. When the specific activity of 210Pb is much higher than that of 210Po in the sample, the relative standard uncertainty of the 210Po determination increases significantly within a short time interval between the sampling date (or reference date) and the separation date of Po in samples.  相似文献   

6.
Kim G  Hussain N  Church TM  Yang HS 《Talanta》1999,49(4):851-858
A practical technique has been developed for the determinations of (234)Th simultaneously with (210)Po and (210)Pb in seawater samples, which greatly simplifies the on-board chemical procedures and enables an accurate correction of (234)Th ingrowth. A unique feature of this technique lies in the exact determination of co-precipitated (238)U following Fe(OH)(3) precipitation which leads to an exact correction of ingrown (234)Th between Fe(OH)(3) precipitation and U/Th separation. Such a correction eliminates several cumbersome on-board chemistry steps (such as Po plating, Fe(2+) oxidation, and 9 N HCl anion exchange) required in regular procedures to eliminate the (234)Th ingrowth. The total time required for on-board sample treatment (spike equilibration, Fe (OH)(3) co-precipitation and filtration) could be less than 10 h which significantly increases the sample processing efficiency and data throughput.  相似文献   

7.
8.
Using as eluent a sequence of 3M HCl, 12M HCl, and 8M HNO3, a mixture of210Pb,210Bi, and210Po may be clearly separated on a column of Dowex 1×2−100 anion exchange resin. A Cherenkov count in H2O and the variation in count rate with time confirm that the nuclides emerge in the order210Pb→210Bi→210Po. If 12M HCl is replaced by 1.5M H2SO4/2.3 M Na2SO4, a clean separation also results, but recovery of210Po becomes considerably more difficult. All three nuclides are readily detectable by liquid scintillation counting, with the efficiency for210Pb in the 60–70% range. The Cherenkov aqueous counting efficiency for210Bi is ∼14–15%.  相似文献   

9.
10.
The disintegration rates of35S and45Ca samples were determined by the modified integral counting method, which extrapolates the integral count rate to the zero detection threshold of a liquid scintillation spectrometer. The agreement between the extrapolated value and the standardized disintegration rate of the sample is very satisfactory.  相似文献   

11.
Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific activity of tetrahydrocortisol and tetrahydrocortisone in urine from patients who had received tritium-labelled cortisol was determined by the indicated methods, followed by fraction collection and liquid scintillation counting. The post-column reaction detection procedure was superior to ultraviolet detection, both in selectivity and analysis time. Intra- and inter-assay variance of the post-column reaction detection procedure were 3.7 and 4.7%, respectively. A good correlation (r = 0.99) was obtained between values determined by this procedure and by a thin-layer chromatographic procedure.  相似文献   

12.
Journal of Radioanalytical and Nuclear Chemistry - Lead-210 is a useful tracer in environmental studies for a wide range of applications, particularly in atmospheric research and geochronology....  相似文献   

13.
The viability of a dual label liquid scintillation technique has been investigated. To avoid the need for two procedures, gamma counting for125Iodine (125I) and liquid scintillation counting for14C. Since the125I spectrum covers almost as wide a range of pulse heights as14C, conventional dual label methods would result in very low14C counting efficiencies. The conventional dual label technique has ben modified to increase the14C counting efficiency and to accomodate the consequent additional spillover of125I counts into the upper window. This dual label technique has been applied to the determination of125I and14C activities in blood samples. The accuracy of the method has been tested, and its advantages and limitations are discussed.  相似文献   

14.
When measuring210Pb via its progenies using the extractive cocktail PolexTM, the sample must be transferred to a phosphate system. When measuring low level samples, care has to be taken in the choise of the phosphoric acid used, as it may contain rather large amounts of210Pb. Typical activity concentrations for products of different manufacturers are given.  相似文献   

15.
A rapid method for the separation of 210 Po from 210 Pb was developed utilizing extraction of triisooctylamine (TIOA)/xylenein HCl+H2O2 medium. Polonium in the form of PoCl 6 2– was extracted into TIOA phase and 210Pb remains in the aqueous phase. Lead-210 was determined by -countingof its granddaughter, 210 Po ingrown from 210 Pb forsome period of time. Distribution of 210 Po and 210Pb in TIOA and aqueous phases was investigated in various concentrations ofHCl media. Hydrogen peroxide was used to further decompose organic matterand to remove sulfur to prevent its deposition on the silver disc. The improvedprocedure resulted in a good chemical yield (80–95%) and a good á-resolution.  相似文献   

16.
17.
This work describes a procedure for the isolation of 90Sr and 210Pb from deer bones by anion exchange methods and their sequential measurement by LSC. To prevent collection of Pb on the Sr·Spec® resin we first separated Pb on a Dowex anion exchange column. Sr, which is not held back on the Dowex column, was then purified using Sr·Spec® resin: first Ca and the Ra isotopes were eluted with 3 M HNO3 and then Sr was eluted with distilled water. With this 2-steps procedure pure 210Pb and 90Sr spectra can be achieved. The chemical yield of both steps was determined by ICP-MS. Our 90Sr results show satisfying agreement with data obtained by a shorter Sr·Spec® method and also by the “classical” 90Sr determination using fuming nitric acid. Also 210Pb results were checked by re-measuring bone samples with already known 210Pb activities. Further our method was verified on the reference sample IAEA-A-12.  相似文献   

18.
Liquid scintillation counting has not been widely applied to a-particle detection because of its poor energy resolution and variable background. In the present work, a time saving and reasonably accurate method for determination of 226Ra in water has been developed, using liquid scintillation spectrometry and pulse-shape analysis. The effect of three levels of chemical quench on the spillover of alpha interactions into the beta window and vice versa was assessed. The advantages of liquid scintillation in comparison with other methods (radon emanation) for determination of 226Ra are the high counting efficiency (~100%) and the easier sample preparation, with no need for sample preconcentration.  相似文献   

19.
Sandhya D  Subramanian MS 《Talanta》1998,46(5):921-926
A sensitive and selective radiometric method of substoichiometric isotope dilution analysis for the determination of trace amounts of zinc is described. The activity of (65)Zn used as a tracer in this method was measured by liquid scintillation counting and its counting efficiency was found to be 76+/-2.7%. The method is based on the extraction of the ion-association complex of zinc from thiocyanate medium at pH 7.9 using substoichiometric amount of Aliquat-336 in toluene. The method is sensitive to 20 ng of Zn(II) in an aqueous phase volume of up to 15 ml and its reliability was tested by applying it to a certified reference material-magnesium alloy and pharmaceutical samples.  相似文献   

20.
210Po and 210Pb concentrations have been determined in 58 cigar brands manufactured in 11 countries. Cuban and American cigars showed the lowest 210Po content. The mean levels of 210Po in Brazilian, European and Dominican cigars were almost identical and somewhat lower than the levels observed for cigars from other Latin American countries. Cuban, American and European cigars contained low levels of 210Pb. Cigars from the remaining countries contained twice as much 210Pb. The mean 210Po/210Pb ratio showed an excess of polonium. In the case of a one cigar-a-day smoker, the calculated annual absorbed dose due to 210Po is -16 mGy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号