首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
A fast and simple capillary zone electrophoresis method was developed and validated for the determination of lidocaine in skin using tape samples. Separation was performed in a 350 mm (265 mm to window) x 50 microm i.d. fused silica capillary using a background electrolyte of phosphoric acid-Tris pH 2.5. The extraction of lidocaine from tape samples was achieved using methanol, which was diluted to 50% with water before injection. Procaine was the internal standard. The migration times for procaine and lidocaine were 2.9 and 3.2 min, respectively. The limit of quantification for lidocaine was 50 microg, with signal to noise ratio greater than 10. The calibration curve was linear from 50 to 1000 microg with r(2) greater than 0.99. The CV for both within- and between-assay imprecision and the percentage of inaccuracy for the quality control samples including lower and upper limits of quantitation were 97%. The accuracy and selectivity of this method allowed the measurement of lidocaine in tape samples obtained from a skin tape stripping study of local anesthetics in healthy subjects.  相似文献   

2.
A non-aqueous capillary electrophoresis (NACE) method for quantifying the seven crocin metabolites that are the major biologically active ingredients of saffron was developed. Separation is done by using a fused silica capillary filled with a 12.5 mM H3BO3/37.5 mM sodium tetraborate methanolic solution as background electrolyte. The results obtained were compared with the total index "safranal value", widely used as a quality measure of saffron products. The comparison revealed that the proposed NACE method provides useful information not obtained in the safranal value. Infact, samples with a similar safranal value can contain crocin metabolites in different concentrations and relative proportions. This new method is very useful for quality control in commercial saffron samples.  相似文献   

3.
In the present study, nonaqueous capillary electrophoretic separation of imatinib mesylate (IM) and related substances, N-(5-amino-2-methylphenyl)-4-(3-pyridyl)-2-pyrimidinamine (PYA), N-(4-methyl-3-(4-(pyridin-3-yl)pyrimidin-2-ylamino)phenyl)-4-((piperazin-1-yl)methyl) benzamide (NDI) and 4-chloromethyl-N-(4-methyl-3-((4-(pyridin-3-yl) pyrimidin-2-yl) amino) phenyl) benzamide (CPB) was developed. The influential factors affecting separation, including type and concentration of the electrolyte, applied voltage, and buffer modifier were investigated. Baseline separation of the studied analytes was obtained using a buffer of 50 mM Tris and 50 mM methanesulfonic acid in methanol at a apparent pH (pH*) of 1.65. To enhance the sensitivity, large-volume sample stacking was employed for online concentration. The strongest analytical signal with a suitable separation was achieved when the injection time was 100 s. The linearity ranges of PYA and NDI were 0.100-2.50 μg mL(-1) , and that of CPB was 0.125-2.50 μg mL(-1) , with good coefficients (r(2) > 0.9948). The relative standard deviations of intra- and interday were satisfactory. Under the optimized conditions, seven batches of the synthesized samples were analyzed and CPB was detected in two batches. Owing to its simplicity, effectiveness, and low price, the developed method is promising for quality control of IM.  相似文献   

4.
An original capillary electrophoretic method has been developed and applied for the enantioselective analysis of the antiparkinson drug biperiden in pharmaceutical formulations, using a modified cyclodextrin as the chiral selector. Baseline enantioseparation of the racemic compound was achieved in less than 7 min using an uncoated fused silica capillary (50 μm i.d. and 48.5, 40.0 cm, total and effective length, respectively), filled with a background electrolyte consisting of a 50 mM phosphate buffer at pH 3.5 supplemented with 3% (w/v) β-cyclodextrin sulphate and applying a voltage of 20 kV, reversed polarity. Samples were injected by pressure (50 mbar, 90 s) at the cathodic end of the capillary and detection wavelength was 195 nm (bandwidth: 10 nm). A simple and fast pre-treatment procedure allowed the complete extraction of the drug from commercial formulations (sustained release tablets and ampoules for injections) without any interference from the matrix. Good linearity was found in the 1–50 μg/mL concentration range; the limit of quantitation was 1 μg/mL and the limit of detection was 0.4 μg/mL. Precision and accuracy were good, with R.S.D. values always lower than 2.8% and a mean recovery value of 101.1%. The method was suitable for the quality control of biperiden in commercial formulations.  相似文献   

5.
Summary A capillary electrophoretic method has been developed for the determination of the main product as well as of by-products in technical samples of substituted pyrimidines. Both zone electrophoresis and micellar electrokinetic chromatography have been used for the separation employing electrolytes consisting of borate buffers (pH 9 to 9.4) with or without sodium dodecylsulfate. Optimization of separation selectivity could be achieved by addition of up to 20% 2-propanol or methanol to the carrier electrolyte. Quantification by internal standards resulted in relative standard deviations between 0.2 and 0.8%. By-products could be analyzed down to levels of 0.1% in technical samples.
Analyse von Pyrimidinderivaten mitteles Kapillarelektrophorese
Zusammenfassung Für die Bestimmung von Haupt- und Nebensubstanzen in technischen Proben von substituierten Pyrimidinen wurde ein kapillarelektrophoretisches Analysenverfahren entwickelt. Sowohl Zonenelektrophorese als auch mizellare elektrokinetische Chromatographie mit Trägerelektrolyten bestehend aus Boratpuffern (pH 9 bis 9.4) mit oder ohne Natriumdodecylsulfat wurden für die Trennung eingesetzt. Eine Optimierung der Trennselektivität war durch die Zugabe von bis zu 20% 2-Propanol oder Methanol zum Trägerelektrolyten möglich. Quantifizierung mittels interner Standards ergab relative Standardabweichungen zwischen 0.2 und 0.8%. Nebenprodukte konnten in technischen Proben bis zu Gehalten von 0.1% analysiert werden.
  相似文献   

6.
The aim of this study was to establish a rapid quality assessment method for Gentianae Macrophyllae Radix (RGM) using near-infrared (NIR) spectra combined with chemometric analysis. The NIR spectra were acquired using an integrating sphere diffuse reflectance module, using air as the reference. Capillary electrophoresis (CE) analyses were performed on a model P/ACE MDQ Plus system. Partial least squares-discriminant analysis qualitative model was developed to distinguish different species of RGM samples, and the prediction accuracy for all samples was 91%. The CE response values at each retention time were predicted by building a partial least squares regression (PLSR) calibration model with the CE data set as the Y matrix and the NIR spectra data set as the X matrix. The converted CE fingerprints basically match the real ones, and the six main peaks can be accurately predicted. Transforming NIR spectra fingerprints into the form of CE fingerprints increases its interpretability and more intuitively demonstrates the components that cause diversity among samples of different species and origins. Loganic acid, gentiopicroside, and roburic acid were considered quality indicators of RGM and calibration models were built using PLSR algorithm. The developed models gave root mean square error of prediction of 0.2592% for loganic acid, 0.5341% for gentiopicroside, and 0.0846% for roburic acid. The overall results demonstrate that the rapid quality assessment system can be used for quality control of RGM.  相似文献   

7.
李亚萍  虞烈  谢友柏  梁恒 《化学学报》1999,57(3):281-288
以非平衡热力学分离理论为框架,建立了毛细管电泳分离大系统的分离模型。以分离过程的操作电压U为控制量,以溶质体系的净分离熵S~S作为目标函数,通过对分离大系统的优化设计,得到了最优操作电压控制轨线U^*(t)。通过仿真,证明了分离大系统在此最优控制规律作用下,分离效果最好。  相似文献   

8.
A precise and accurate method has been developed for the determination of methylmercury in biological material using capillary gas chromatography with electron-capture detection. Homogenized fish or mussel samples were digested with acid, spiked with ethylmercury chloride as an internal standard and extracted with toluene. After treatment of the solvent extract with sodium thiosulphate and cupric bromide the alkylmercurials were extracted into benzene as their bromide derivatives and analyzed using an OV-275 coated glass capillary column. The detection limit of the method for methylmercury was 5 g/kg tissue.  相似文献   

9.
《Electrophoresis》2018,39(4):569-580
A fast and precise affinity capillary electrophoresis (ACE) method has been applied to investigate the interactions between two serum albumins (HSA and BSA) and heparinoids. Furthermore, different free flow electrophoresis methods were developed to separate the species which appears owing to interaction of albumins with pentosan polysulfate sodium (PPS) under different experimental conditions. For ACE experiments, the normalized mobility ratios (∆R/Rf), which provided information about the binding strength and the overall charge of the protein‐ligand complex, were used to evaluate the binding affinities. ACE experiments were performed at two different temperatures (23 and 37°C). Both BSA and HSA interact more strongly with PPS than with unfractionated and low molecular weight heparins. For PPS, the interactions can already be observed at low mg/L concentrations (3 mg/L), and saturation is already obtained at approximately 20 mg/L. Unfractionated heparin showed almost no interactions with BSA at 23°C, but weak interactions at 37°C at higher heparin concentrations. The additional signals also appeared at higher concentrations at 37°C. Nevertheless, in most cases the binding data were similar at both temperatures. Furthermore, HSA showed a characteristic splitting in two peaks especially after interacting with PPS, which is probably attributable to the formation of two species or conformational change of HSA after interacting with PPS. The free flow electrophoresis methods have confirmed and completed the ACE experiments.  相似文献   

10.
A rapid method for the enantioseparation of pramipexole and its R‐enantiomer has been developed by capillary electrophoresis. The influence of chemical and instrumental parameters was investigated including the type and concentration of chiral selectors, buffer composition and pH, co‐ions, applied voltage, capillary length and temperature. Optimal separation conditions were obtained using a 50 mM phosphate buffer (pH 2.8) containing 25 mM carboxymethyl‐β‐cyclodextrin on a fused‐silica capillary. Online UV detection was performed at 262 nm. A voltage of 25 kV was applied, and the capillary temperature was kept at 25°C. Hydrodynamic injection was performed at 3.45 kPa for 5.0 s. The separation of enantiomers was achieved in <6.5 min. The method was further validated in terms of stability of solutions, selectivity, linearity (both pramipexole and R‐enantiomer, R2>0.995), LOD and LOQ (0.91 and 2.94 μg/mL, respectively), repeatability (RSD<1.5%) and accuracy (pramipexole, 100.4%; R‐enantiomer, 100.5%). The proposed method was then applied to two kinds of pramipexole dihydrochloride monohydrate commercially available tablets, immediate release tablets (1.50 and 0.125 mg) and sustained release tablets (0.52 mg), to quantify the main component in the tablets. The amount of distomer could be quantified in bulk sample materials.  相似文献   

11.
Zidovudine (AZT) therapy given during pregnancy has been shown to reduce the vertical transmission of the human immunodeficiency virus (HIV) from mother to fetus. In order to investigate the efficacy of AZT, it is important to know the concentration of its active phosphorylated metabolites. We have developed the first CE method for the simultaneous quantitation of AZT and zidovudine monophosphate (AZT-MP) from rat plasma, amniotic fluid and fetal tissues. Sample extractions were performed by protein precipitation using acetonitrile for the plasma and amniotic fluids, while in fetal tissues solid phase extraction using Waters Oasis HLB extraction cartridges was used. Recoveries ranged from 78 to 92% for AZT, AZT-MP and 3'-azidouridine (internal standard, AZDU), in the three matrices. The optimum separation conditions were achieved using a 40 mm sodium dodecylsulfate (SDS) in 50 mm phosphate buffer (pH 7) with a run voltage of 15 kV. The CE system consists of a 75 microm i.d., 50 cm effective length uncoated fused silica capillary. The method was validated over the range 0.5-100 microg/ml ( micro g/g for tissues). Intra-day precision (RSD) and accuracy (%error) for AZT ranged from 0.13 to 11 and 0.68 to 11.1%, respectively, while for AZT-MP it ranged from 2.05 to 11.1 and 4.22 to 11.7%. Inter-day precision and accuracy for AZT ranged from 3.82 to 11.2 and 3.14 to 9.01%, while for AZT-MP it ranged from 3.9 to 9.32 and 3.44 to 9.37%, respectively. We also report the enzymatic dephosphorylation of AZT-MP in the placental tissue of rats. This new enzymatic pathway provides increased understanding of the mechanism of anti-viral transport in the rat during pregnancy.  相似文献   

12.
This paper presents an inexpensive and easy-to-implement voltage sequencer instrument for use in microchip capillary electrophoresis (MCE) actuation. The voltage sequencer instrument takes a 0–5 V input signal from a microcontroller and produces a reciprocally proportional voltage signal with the capability to achieve the voltages required for MCE actuation. The unit developed in this work features four independent voltage channels, measures 105 × 143 × 45 mm (width × length × height), and the cost to assemble is under 60 USD. The system is controlled by a peripheral interface controller and commands are given via universal serial bus connection to a personal computer running a command line graphical user interface. The performance of the voltage sequencer is demonstrated by its integration with a fluorescence spectroscopy MCE sensor using pinched sample injection and electrophoretic separation to detect ciprofloxacin in samples of milk. This application is chosen as it is particularly important for the dairy industry, where fines and health concerns are associated with the shipping of antibiotic-contaminated milk. The voltage sequencer instrument presented represents an effective low-cost instrumentation method for conducting MCE, thereby making these experiments accessible and affordable for use in industries such as the dairy industry.  相似文献   

13.
We have investigated the influence of capillary temperature on migration time and peak area and have evaluated different cooling systems. It was found that for applied voltages below 15 kV (i.e. those most frequently used) temperature control effectively improves peak area reproducibility but has less effect on migration time.  相似文献   

14.
The purity profile for porcine secretin attributable to contamination by equilibrium products such as aspartoyl(3) secretin has been shown to be dependent on the pH of the analytical system. Capillary zone electrophoresis (CZE) methods have been developed for the efficient separation of synthetic porcine secretin, its equilibrium products and other impurities in aqueous solutions at both acidic and alkaline pH. These conditions are more representative of those used for the reconstitution and administration of porcine secretin, and good results cannot be achieved using HPLC due to poor peak shape above pH 5.8. The influence of various CZE operational parameters was systematically examined. The methods were validated for accuracy, precision, linearity, LOD and LOQ. A comparative evaluation of the stability of test solutions was determined using CZE and HPLC over a range of pH values. HPLC and CZE methods produced similar results at low pH.  相似文献   

15.
Eight textile dye compounds including five cationic dyes, namely, basic blue 41, basic blue 9, basic green 4, basic violet 16 and basic violet 3, and three anionic dyes, acid green 25, acid red 1 and acid blue 324, were separated and detected by non-aqueous capillary electrophoresis (NACE) with electrochemical detection. Simultaneous separations of acid and basic dyes were performed using an acetonitrile-based buffer. Particular attention was paid to the determination of basic textile dyes. The optimized electrophoresis buffer for the separation of basic dyes was a solvent mixture of acetonitrile/methanol (75:25, v/v) containing 1 M acetic acid and 10 mM sodium acetate. The limits of detection for the basic dyes were in the range of 0.1–0.7 μg mL−1. An appropriate solid-phase extraction procedure was developed for the pre-treatment of aqueous samples with different matrices. This analytical approach was successfully applied to various water samples including river and lake water which were spiked with textile dyes.  相似文献   

16.
Summary In isothermal CE the migration velocity of analytes and the number of theoretical plates delivered are expected to be proportional to the field strength. In reality ohmic heating of the capillary causes distortions: the migration velocity increases more rapidly while the plate count increases less rapidly, and may even fall at high values of the field. These distortions are worse the larger the bore of the capillary and the higher the concentration of buffer. A detailed investigation of these effects using capillaries cooled by natural convection has confirmed that self heating of the capillary is indeed largely responsible. The extent of self heating has been determined by three independent methods and to a first approximation is proportional to the power dissipation in the capillary. Decreasing viscosity with temperature is responsible for the nonlinearity of the dependence of velocity upon field strength while increase in the diffusion coefficient of analytes is responsible for the poorer than expected performance at high field strengths.  相似文献   

17.
高效毛细管电泳分离及检测蛋氨酸对映体   总被引:1,自引:0,他引:1  
蛋氨酸(Methionine)学名甲硫基丁氨酸,分子式C5H11NO2S,相对分子质量149.2。在蛋白质合成中,蛋氨酸是信息核糖核酸“翻译”成蛋白质过程中的第一步。无蛋氨酸的存在,蛋白质生物的合成就无法开始。适用于防治肝脏疾病和砷中毒,也用作食品的添加剂。蛋氨酸有D,L两种构型。目前尚未见用Cu^2+做手性选择剂毛细管电泳电化学拆分D,L-蛋氨酸的报道。电化学检测(主要是安培检测和电导检测)具有操作简单、维护方便、无须衍生化处理等优点,  相似文献   

18.
Guan J  Wang H  Ren L  Niu Q 《色谱》2012,30(1):107-110
建立了同时测定乙醛酸和草酸的毛细管区带电泳法。考察了缓冲溶液的种类、浓度和pH以及分离电压等因素对分离结果的影响。在缓冲溶液为20 mmol/L硼砂-5.5 mmol/L邻苯二甲酸氢钾(pH 9.0)、分离电压20 kV、检测波长212 nm的优化条件下,11 min内即可实现对目标物的分离。乙醛酸和草酸分别在0.8~20 g/L和1.2~20 g/L范围内线性关系良好,相关系数分别为0.9993和0.9975;方法的检出限分别为0.2和0.4 g/L(信噪比为3);样品的加标回收率为98.3%~102.5%,相对标准偏差为0.35%~0.61%。该方法操作简便、快速、成本低廉,已应用于实际样品的分析,并获得了令人满意的结果。  相似文献   

19.
The feasibility of using the affinity CE methodologies pre-equilibrium CZE and CE frontal analysis was tested on interaction systems exhibiting rapid on-and-off kinetics. Experimentally, the methodologies differ only with respect to the volume of sample introduced into the capillary. Pre-equilibrium CZE has been considered amendable to interactions with slow on-and-off kinetics only; however, it has recently been applied in studies of interactions with fast on-and-off kinetics. The effect of varying the sample volume introduced hydrodynamically into the capillary on the apparent degree of complexation was studied. For two different binding systems, the fraction of free analyte was found to be overestimated using pre-equilibrium CZE as compared to volumes providing plateau peak conditions as used with frontal analysis. Results indicate that frontal analysis conditions lead to more robust binding assays and thus more reliable data. The validity of data obtained by pre-equilibrium CZE may be low, thus the use of an experimental setup providing plateau peaks is highly recommended. It is suggested that the effect of altering the sample volume on the degree of binding should be investigated as part of method development and validation.  相似文献   

20.
孙毓庆  孙国祥  金郁 《色谱》2008,26(2):160-165
以作者多年从事毛细管电泳、毛细管电泳-质谱联用及其指纹图谱对中药的研究成果为基础,介绍了毛细管电泳实验条件的优化方法、毛细管电泳指纹图谱的研究方法与评价方法及其在中药质量控制中的作用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号