首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 234 毫秒
1.
A selective method has been developed for extraction chromatographic studies of aluminium(III) and its separation from several metal ions with a chromatographic column containing N-n-octylaniline (liquid anion exchanger) coated on silanized silica gel as a stationary phase. The aluminium(III) was quantitatively extracted with the 0.065 mol/L N-n-octylaninine from 0.013 to 0.05 mol/L sodium succinate at a flow rate of 1.0 mL/min. The extracted metal ion has been recovered by eluting with 25.0 mL of 0.05 mol/L hydrochloric acid and estimated spectrophotometrically with aurintricarboxylic acid. The effects of the acid concentration, the reagent concentration, the flow rate and the eluting agents have been investigated. The log-log plots of distribution coefficient (KdAl(III)) versus N-n-octylaniline concentrationin 0.005 and 0.007 mol/L sodium succinate gave theslopes 0.5 and 0.7 respectively and showed theprobable composition of theextracted species was 1:1 (metal to amine ratio) and the nature of extracted species is [RR''NH2+ Al succinate2-] org. .The extraction of aluminium(III) was carried out in the presence of various ions to ascertain the tolerance limit of individual ions. Aluminium(III) has been separated from multicomponent mixtures, pharmaceutical samples and synthetic mixtures corresponding to alloys. A scheme for mutual separation of aluminium(III), indium(III), gallium(III) and thallium(III) has been developed by using suitable masking agents. The method is fast, accurate and precise.  相似文献   

2.
A column chromatographic method has been developed for the separation and determination of cerium(Ⅲ) using poly[dibenzo-18-crown-6]. The separation was carried out in L-valine medium. The adsorption of cerium(Ⅲ) was quantitative from 1×10-1 to 1×10-4 mol/L L-valine. Amongst the various eluents, 1.0-8.0 mol/L hydrochloric acid, 1.0-8.0 mol/L hydrobromic acid, 1.0-8.0 mol/L perchloric acid, 1.0-2.0 mol/L sulfuric acid and 4.0-5.0 mol/L acetic acid, were found to be the efficient eluents for cerium(Ⅲ). The capacity of poly[dibenzo-18-crown-6] for cerium(Ⅲ) was (0.428±0.01) mmol/g. The method was applied to the separation of cerium(Ⅲ) from associated elements link uranium(Ⅵ) and thorium(Ⅳ). It was also applied for the determination of cerium(Ⅲ) in geological samples. The method is simple, rapid and selective with good reproducibility (approximately±2% ).  相似文献   

3.
 A column chromatographic method has been developed for the separation and determination of cerium(Ⅲ) using poly[dibenzo-18-crown-6]. The separation was carried out in L-valine medium. The adsorption of cerium(Ⅲ) was quantitative from 1×10-1 to 1×10-4 mol/L L-valine. Amongst the various eluents, 1.0-8.0 mol/L hydrochloric acid, 1.0-8.0 mol/L hydrobromic acid, 1.0-8.0 mol/L perchloric acid, 1.0-2.0 mol/L sulfuric acid and 4.0-5.0 mol/L acetic acid, were found to be the efficient eluents for cerium(Ⅲ). The capacity of poly[dibenzo-18-crown-6] for cerium(Ⅲ) was (0.428±0.01) mmol/g. The method was applied to the separation of cerium(Ⅲ) from associated elements link uranium(Ⅵ) and thorium(Ⅳ). It was also applied for the determination of cerium(Ⅲ) in geological samples. The method is simple, rapid and selective with good reproducibility (approximately±2%).  相似文献   

4.
 A reversed-phase high performance liquid chromatography (HPLC) method was developed, validated, and used for the quantitative determination of gatifloxacin (GA) and ambroxol hydrochloride (AM), from its tablet dosage form. Chromatographic separation was performed on a HiQ Sil C18 column (250 mm×4.6 mm, 5 μm), with a mobile phase comprising of a mixture of 0.01 mol/L potassium dihydrogen orthophosphate buffer and acetonitrile (70∶30, v/v), and pH adjusted to 3 with orthophosphoric acid, at a flow rate of 1 mL/min, with detection at 247 nm. Separation was completed in less than 10 min. As per International Conference on Harmonisation (ICH) guidelines the method was validated for linearity, accuracy, precision, limit of quantitation, limit of detection, and robustness. Linearity of GA was found to be in the range of 10-60 μg/mL and that for AM was found to be 5-30 μg/mL. The correlation coefficients were 0.9996 and 0.9993 for GA and AM respectively. The results of the tablet analysis (n=5) were found to be 99.94% with ±0.25% standard deviation (SD) and 99.98% with±0.36% SD for GA and AM respectively. Percent recovery of GA was found to be 99.92%-100.02% and that of AM was 99.86%-100.16%. The assay experiment shows that the method is free from interference of excipients. This demonstrates that the developed HPLC method is simple, linear, precise, and accurate, and can be conveniently adopted for the routine quality control analysis of the tablet.  相似文献   

5.
Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/Lα-HIBA(adjusted to pH 4.8 by HAc solution).The post-capillary reagent was 2.0 mmol/L K_3Fe(CN)_6 which was adjusted to pH 13.0 by NaOH solution.Under the optimum conditions,the detection limits(S/N=3)for Co(Ⅱ)and Cu(Ⅱ)were 7.5×10~(-11)mol/L and 7.5×10~(-9)mol/L,with the linear range of 7.5×10~(-9)mol/L to 1.0×10~(-6)mol/L and 7.5×10~(-8)mol/L to 5.0×10~(-5)mol/L, respectively.  相似文献   

6.
A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior to flame atomic absorption spectrometric determinations.The method is based on the sorption of mentioned ions on synthesized GO using 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide as a chelating agent.Several parameters on the extraction and complex formation were optimized.Under the optimized conditions(pH 6,flow rate 9 mL/min),metal ions were retained on the column,then quantitatively eluted by HNO3solution(5 mL,3.0 mol/L).The preconcentration factor was calculated as250.The detection limits for the analyte ions of interest were found in the range of 0.11 ng/mL(Ni2+) to0.63 ng/mL(Cu2+).The column packed with GO was adequate for metal ions separation in matrixes containing alkali,alkaline earth,transition and heavy metal ions.  相似文献   

7.
In the present work, a novel method to extract three kinds of spices, namely vanillin, ethyl vanillin and ethyl maltol from food products such as biscuit, chocolate and milk powder was developed. 1-Octyl-3-methylimidazolium chloride([Omim]Cl) aqueous solution was selected as the extracting medium. A 0.5 g powder of food product was extracted by 5.0 mL of [Omim]Cl aqueous solution(0.3 mol/L, pH 6.0) under ultrasonication at 50 8C, and then the extract was centrifuged for 10 min at 4000 rpm. The extract was filtered through a syringe filter and injected into ion chromatography system for analysis. The separation of the three spices was carried out on an anion exchange column. The detection wavelength was set at 280 nm. Compared with traditional extraction solvents, [Omim]Cl aqueous solution displayed particular advantages. The applicability of the proposed method to real sample was confirmed. Under the optimal conditions, good reproducibility of extraction performance was obtained, with the relative standard deviation(RSD) values ranging from 1.9% to 6.3%. The recoveries of spiked samples were between 79.8% and 95.8%. The detection limits(LOD, S/N = 3) of vanillin, ethyl vanillin and ethyl maltol were in the range of 20–45 mg/kg. The use of ionic liquid aqueous solution as extraction solvent was operationally easy and environmental-friendly.  相似文献   

8.
《色谱》2015,(6)
A simple and sensitive method for the separation and determination of isoproterenol from other doping drugs has been developed on thin layers of bismuth silicate,a synthetic inorganic ion exchanger as adsorbent in thin layer chromatography(TLC).A mixture of methanol and 0.1 mol/L formic acid(3∶7,v/v)was employed as the mobile phase.The development time was 32 min.The quantitative measurement were performed with a Camag TLC Scanner-3 at wavelength(λ)of 410 nm.The isoproterenol recovery in this procedure was 98.9%.The linear correlation coefficient was greater than 0.987 1 and the relative standard deviation(RSD)was less than 0.94.The limit of detection(LOD)and limit of quantification(LOQ)were 7.7×10-7mol/L and 3.85×10-6mol/L,respectively.This method has been applied in the determination of isoproterenol in dosage forms and in biological fluids.  相似文献   

9.
Ion-exclusion/anion-exchange chromatography(IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH——form with basic eluent has been developed.The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase.This system is useful for simultaneous separation and determination of ammonium ion(NH+4),nitrite ion(NO-2),and nitrate ion(NO-3) in water samples.The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column.In this study,several separation columns,which consisted of different particle sizes,different functional groups and different anion-exchange capacities,were compared.As the results,the separation column with the smaller anion-exchange capacity(TSKgel Super IC-Anion) showed well-resolved separation of cations and anions.In the optimization of the basic eluent,lithium hydroxide(LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L,considering the resolution of analyte ions and the whole retention times.In the optimal conditions,the relative standard deviations of the peak areas and the retention times of NH+4,NO-2,and NO-3 ranged 1.28%-3.57% and 0.54%-1.55%,respectively.The limits of detection at signal-to-noise of 3 were 4.10 μmol/L for NH+4,1.87 μmol/L for NO-2 and 2.83 μmol/L for NO-3.  相似文献   

10.
高效液相色谱-荧光检测法测定人血浆中匹伐他汀的含量   总被引:2,自引:0,他引:2  
 Pitavastatin belongs to the class of coenzyme A reductase inhibitors. Very few methods of assaying pitavastatin from human plasma are available in literature. An analytical method is presented for the determination of the drug from human plasma making use of the fluorescent property of the drug. The drug is extracted from plasma using ethyl acetate under neutral condition and then analyzed by reversed-phase high performance liquid chromatography (HPLC) with fluorescence detection (λEx 245 nm; λEm 420 nm). Analysis of pitavastatin was carried out on a C18 HPLC column using a gradient flow of mobile phase (0.01 mol/L monobasic potassium phosphate (pH 3.20)-acetonitrile, 63∶37, v/v). Fluorescein isothiocyanate was used as internal standard. The dynamic range of assay was 3 to 50 ng/mL. The intraday precision was less than 10% and accuracy ranged from 95.2% to 112.6%. The same for interday check was less than 12% and 92.8% to 105.1%, respectively. The drug was found to be stable under the assay conditions. The developed method is simple, precise, accurate, and stable. This indicates that it can be applied to routine analysis of this drug in human subjects where there are large numbers of samples without the need of specialized instruments like column switching.  相似文献   

11.
N-n-octylaniline in xylene is used for the extractive separation of gold(III) from halide media. Gold(III) was extracted quantitatively with 10 ml of 2% reagent in xylene from 0.5-10 M and 0.5-8 M hydrochloric acid and hydrobromic acid, respectively. It was stripped from the organic phase with ammonia buffer solution (pH 10.1) and estimated spectrophotometrically with stannous chloride. The effect of metal ion, acids, reagent concentration and of various foreign ions has been investigated. Method is applicable to the analysis of synthetic mixtures containing platinum metals and alloy samples. The method is fast, accurate and precise.  相似文献   

12.
Lokhande TN  Anuse MA  Chavan MB 《Talanta》1998,47(4):823-832
N-n-octylaniline in xylene is used for the extractive separation of platinum(IV) from acidic media. Platinum(IV) was extracted quantitatively with 10 ml of 3% reagent in xylene from 0.5 to 10 and 2.5 to 10 M hydrochloric and sulphuric acid, respectively. It was stripped from organic phase with water and estimated photometrically with stannous chloride. The effect of metal ion, acids, reagent concentration and of various foreign ions has been investigated. The method affords binary separation of platinum(IV) from iron(III), cobalt(II), nickel(II) and copper(II), and is applicable to the analysis of synthetic mixtures and alloys. The method is fast, accurate and precise.  相似文献   

13.
A new an innovative separation method has been developed using N-n-octylaniline (liquid anion exchanger) coated on silica gel. Ruthenium(III) has been extracted quantitatively from 0.05 M hydrochloric acid, striped with aqueous solution of various acids and then determined by spectrophotometric method. Mutual separation scheme for ruthenium(III), iridium(III) and osmium(VIII) has been developed. Ruthenium(III) has been separated from commonly associated elements. Different parameter are studied viz effect of acid concentration, reagent concentration, striping agent, flow rate, foreign ion and synthetic mixture corresponding to alloys. Validity of method has been verified by separation of ruthenium(III) from fissium alloy.  相似文献   

14.
逐级提取-高效液相色谱法快速测定植物组织中8种有机酸   总被引:2,自引:0,他引:2  
黄天志  王世杰  刘秀明  刘虹  吴沿友  罗绪强 《色谱》2014,32(12):1356-1361
针对植物组织中草酸存在的不同形态,建立了水和稀盐酸作为提取介质的逐级提取方法,获得了水溶态和酸溶态草酸及乙醇酸、乙醛酸、酒石酸、苹果酸、乙酸、柠檬酸、琥珀酸等有机酸。采用Hypersil ODS (200 mm×4.6 mm, 5 μm)色谱柱,以5 mmol/L磷酸二氢钾水溶液(pH 2.8)作为流动相,在进样量5 μL、检测波长210 nm、柱温30 ℃的条件下,通过分时段控制流速实现了8种有机酸的快速分离,同时去除了盐酸对酸溶态草酸测定的干扰。本方法精确灵敏、回收率高、重复性好,可应用于实际样品的测定分析。  相似文献   

15.
Kolekar SS  Anuse MA 《Talanta》2002,58(4):761-771
Solvent extraction separation method for the determination of rhodium(III) has been described. Selective and quantitative extraction of rhodium(III) by N-n-octylaniline, a high molecular weight amine (HMWA) into xylene takes place from aqueous sodium malonate medium. The effect of concentration of malonate, N-n-octylaniline, role of various diluents, stripping agents and foreign ions on the extraction of rhodium(III) has been studied. The procedure offers distinct improvements in need of real sample analysis and environmental safety as the extraction procedure carried out in weak organic acid media.  相似文献   

16.
毛细管电泳-间接紫外检测法测定蜂蜜中的氨基酸   总被引:2,自引:0,他引:2  
周贤婧  师彦平 《色谱》2013,31(7):661-666
采用毛细管电泳-间接紫外检测法同时分离测定蜂蜜中的赖氨酸、色氨酸、谷氨酸等9种氨基酸。考察了磷酸浓度、进样方式和缓冲液pH对分离效率和重现性的影响。在分离电压为-15 kV、检测波长为220 nm条件下,以含有0.5 mmol/L十六烷基三甲基溴化铵、20 mmol/L烟酸、10%甲醇的10 mmol/L磷酸二氢钠缓冲溶液(pH 10.2)为运行缓冲液,9种组分在11 min内达到基线分离;检出限最低可达到0.3 mg/L;线性范围为1.0~1000 mg/L;日间及日内精密度为0.64%~5.83%。实际样品中除甲硫氨酸外的8种氨基酸的加标回收率为60.00%~118.37%。将该方法应用于不同蜜源植物和产地的蜂蜜样品的测定,在市售的5种蜂蜜中均检测到脯氨酸、丝氨酸和天冬氨酸,而只在荔枝蜜中检测到苏氨酸。该方法可以为蜂蜜的蜜源鉴别及质量评估提供借鉴方法。  相似文献   

17.
We have developed the extraction method of rhodium(III) from malonate media with 2‐octylaminopyridine (2‐OAP) in xylene at pH 8.0. The quantitative extraction of rhodium(III) with extractant was found by screening of different physicochemical parameters like malonate concentration, extractant concentration, pH, diluents, effect of temperature, aq: org phase ratio, loading capacity of 2‐OAP. The optimum condition was malonate=0.025 M, pH=8.0, 2‐OAP=0.05 M in xylene. The complete stripping of rhodium(III) from the loaded organic phase was carried out with 2 M HCl. Log‐log plot was investigated to determine the stoichiometry of the extracted species and it was found to be 1 : 2 : 1 (metal : acid :extractant). The versatility of the proposed method was checked for extraction and separation of rhodium(III) from binary, ternary mixture of associated metal ions as well as platinum group metals and from the synthetic solution of rhodium minerals and alloys.  相似文献   

18.
建立了血液样品中4种苏丹染料(苏丹Ⅰ、Ⅱ、Ⅲ和Ⅳ)的固相萃取-超快速液相色谱-串联质谱(UFLC-MS/MS)测定方法。样品经乙腈涡旋振荡提取,上清液加等体积水稀释混匀后移入C18固相萃取小柱净化,采用Agilent Eclipse Plus C18色谱柱(100 mm×2.1 mm,1.8 μm)以0.1%(v/v)甲酸水溶液和0.1%(v/v)甲酸乙腈溶液为流动相梯度洗脱分离,电喷雾电离(ESI)正离子多反应监测模式进行定量分析。讨论了苏丹Ⅲ和苏丹Ⅳ的偶氮基团E-Z光学异构现象,并对影响因素进行了分析。结果4种苏丹染料在0.1~20.0 μg/L范围内线性关系良好,相关系数均大于0.999;在低、中、高3个加标水平的平均回收率为93.0%~108.2%,相对标准偏差为4.8%~9.5%;方法的检出限(LOD)为0.06 μg/L,定量限(LOQ)为0.2 μg/L。本方法准确、快速、灵敏,可用于血液样品中苏丹类染料的检测分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号