首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.
A fast 3D look-locker method for volumetric T1 mapping.   总被引:1,自引:0,他引:1  
We introduce a fast technique, based on the principles of the 2D Look-Locker T1 measurement scheme, to rapidly acquire the data for accurate maps of T1 in three dimensions. The acquisition time has been shortened considerably by segmenting the acquisition of the k(y) phase encode lines. Using this technique, the data for a 256 x 128 x 32 volumetric T1 measurement can be acquired in 7.6 min. T1 measurements made in phantoms with T1s between 200 and 1200 ms had an accuracy of 4% and a reproducibility of 3.5%. Measurements of T1 made in normal brain using the fast 3D sequence corresponded well with inversion-recovery fast spin-echo measurements.  相似文献   

2.
The single-point ramped imaging with T1 enhancement (SPRITE) imaging technique has proven to be a very robust and flexible method for the study of a wide range of systems with short signal lifetimes. As a pure phase encoding technique, SPRITE is largely immune to image distortions generated by susceptibility variations, chemical shift and paramagnetic impurities. In addition, it avoids the line width restrictions on resolution common to time-based sampling, frequency encoding methods. The standard SPRITE technique is however a longitudinal steady-state imaging method; the image intensity is related to the longitudinal steady state, which not only decreases the signal-to-noise ratio, but also introduces many parameters into the image signal equation. A centric scan strategy for SPRITE removes the longitudinal steady state from the image intensity equation and increases the inherent image intensity. Two centric scan SPRITE methods, that is, Spiral-SPRITE and Conical-SPRITE, with fast acquisition and greatly reduced gradient duty cycle, are outlined. Multiple free induction decay (FID) points may be acquired during SPRITE sampling for signal averaging to increase signal-to-noise ratio or for T2* and spin density mapping without an increase in acquisition time. Experimental results show that most porous sedimentary rock and concrete samples have a single exponential T2* decay due to susceptibility difference-induced field distortion. Inhomogeneous broadening thus dominates, which suggests that spin density imaging can be easily obtained by SPRITE.  相似文献   

3.
Fast and precise T1 imaging using a TOMROP sequence   总被引:3,自引:1,他引:2  
Proton spin-lattice (T1) relaxation time images were computed from a data set of 32 gradient-echo images acquired with a fast TOMROP (T One by Multiple Read Out Pulses) sequence using a standard whole-body MR imager operating at 64 MHz. The data acquisition and analysis method which permits accurate pixel-by-pixel estimation of T1 relaxation times is described. As an example, the T1 parameter image of a human brain is shown demonstrating an excellent image quality. For white and gray brain matter, the measured longitudinal relaxation processes are adequately described by a single-component least-squares fit, while more than one proton component has to be considered for fatty tissue. A quantitative analysis yielded T1 values of 547 +/- 36 msec and 944 +/- 73 msec for white and gray matter, respectively.  相似文献   

4.
A full-frame bit-allocation technique of data compression has been implemented using the existing computer facilities of an MR imager. Images reconstructed from compressed data files have been compared with the original image and changes in noise and pixel value measured to evaluate any image degradation introduced by the compression process. A 256 x 256 x 8 bit brain image can be compressed in 20 seconds with a compression ratio of greater than 4:1 without significant loss of information.  相似文献   

5.
The nonhuman primate brain study provides important supplemental means for human brain exploration since the two species share close anatomical and functional similarities. MR diffusion tensor imaging (DTI) in human brain has revealed exquisite details of brain structures especially in the brain white matter. However, most previous monkey brain DTI results lack the spatial resolution in comparison to the conventional tracing and postmortem imaging methods, especially when it is acquired in commonly available human MRI scanners of field strength of 3 T or lower. To meet the increasing demands for nonhuman primate DTI studies, we proposed an in vivo high-resolution monkey DTI acquisition protocol that is practically feasible and combined it with an improved postprocessing procedure for a 3-T human scanner. The acquisition protocol, susceptibility distortion correction method with phase reversal acquisition, and postprocessing steps were proved to be effective in our study of rhesus monkeys. Results from diffusion tensor estimations and fiber tractography at 1 x 1 x 1 mm(3) resolution were found to be comparable to previous ex vivo DTI studies with much longer acquisition times. Effects of image resolution were evaluated and it was confirmed that the partial volume effect due to the larger voxel size in low-resolution data biased the diffusion tensor estimation and produced erroneous fiber tractography. Our results suggest that in vivo high-resolution monkey brain DTI can be achieved within practical time, which allows accurate diffusion tensor estimation and fiber tractography in monkey brains, so that the complex anatomical structures within many small but important anatomic structures can be delineated.  相似文献   

6.
The recent advances in image-processing techniques have led to the development of many methods to reduce the scan time without degrading the image quality. In particular, tomography has improved image reconstruction methods with the concomitant improvement of high-quality images. In this study, PRECEDENCE 16 was used to reconstruct images using the filtered back projection method, which is generally used, and the Astonish method and three-dimensional ordered-subsets expectation maximization method, which are based on repetition techniques. In qualitative and quantitative analysis of the reconstructed images, a comparison was made between images with different acquisition times and between images with the same acquisition time, which aimed at determining the optimal method for reconstructing high-quality images. A blind test for qualitative analysis confirmed almost no difference in image quality depending on the image acquisition time. Furthermore, in quantitative analysis, there was no significant difference in image quality depending on the image acquisition time. On the other hand, the results of the analysis in the image reconstruction method with the same acquisition time demonstrated a significant difference. The images reconstructed by the Astonish method, which uses a repetition technique, are believed to be excellent because they have high resolution and provide clinical diagnostic information. This study confirmed that the reconstruction method with a repetition technique could be used to improve image quality and reduce the scan time, despite not being in general use until recently due to the lengthy time needed for image reconstruction and lack of storage space.  相似文献   

7.
For sparse sampling that accelerates magnetic resonance (MR) image acquisition, non-linear reconstruction algorithms have been developed, which incorporated patient specific a prior information. More generic a prior information could be acquired via deep learning and utilized for image reconstruction. In this study, we developed a volumetric hierarchical deep residual convolutional neural network, referred to as T-Net, to provide a data-driven end-to-end mapping from sparsely sampled MR images to fully sampled MR images, where cartilage MR images were acquired using an Ultra-short TE sequence and retrospectively undersampled using pseudo-random Cartesian and radial acquisition schemes. The network had a hierarchical architecture that promoted the sparsity of feature maps and increased the receptive field, which were valuable for signal synthesis and artifact suppression. Relatively dense local connections and global shortcuts were established to facilitate residual learning and compensate for details lost in hierarchical processing. Additionally, volumetric processing was adopted to fully exploit spatial continuity in three-dimensional space. Data consistency was further enforced. The network was trained with 336 three-dimensional images (each consisting of 32 slices) and tested by 24 images. The incorporation of a priori information acquired via deep learning facilitated high acceleration factors (as high as 8) while maintaining high image fidelity (quantitatively evaluated using the structural similarity index measurement). The proposed T-Net had an improved performance as compared to several state-of-the-art networks.  相似文献   

8.
A low-coherence reflectometer based on a conventional Michelson interferometer and a novel silicon detector chip that allows parallel heterodyne detection is presented. Cross-sectional images of 64x256 pixels covering an area of 1.92 mm x 1.3 mm are acquired at video rate and with a sensitivity close to the shot-noise limit. Applications in surface profiling and thickness measurement are demonstrated.  相似文献   

9.
Sensitivity-encoded phase undersampling has been combined with simultaneous slice excitation to produce a parallel MRI method with a high volumetric acquisition acceleration factor without the need for auxiliary stepped field coils. Dual-slice excitation was produced by modulating both spin and gradient echo sequences at +/-6 kHz. Frequency aliasing of simultaneously excited slices was prevented by using an additional gradient applied along the slice axis during data acquisition. Data were acquired using a four-channel receiver array and x4 sensitivity encoding on a 1.5 T MR system. The simultaneous parallel inclined readout image technique has been successfully demonstrated in both phantoms and volunteers. A multiplicative image acquisition acceleration factor of up to x8 was achieved. Image SNR and resolution was dependent on the ratio of the readout gradient to the additional slice gradient. A ratio of approximately 2:1 produced acceptable image quality. Use of RF pulses with additional excitation bands should enable the technique to be extended to volumetric acquisition acceleration factors in the range of x16-24 without the SNR limitations of pure partially parallel phase reduction methods.  相似文献   

10.
Fast imaging using the STimulated Echo Acquisition Mode (STEAM) sequence can produce cine images of the heart with black-blood contrast. Nevertheless, correction of deformation-related artifacts is required in order to maintain myocardial signal throughout the cardiac cycle. Recent work by our group has eliminated this artifact by combining two STEAM sequences acquired with two different demodulation gradients. Unfortunately, these two STEAM sequences were acquired on two separate breath-holds; thus, scan time doubled. In this work, we present a technique to reduce the total scan time by one half, without sacrificing image quality. The technique is based on interleaving two demodulations within one acquisition in order to obtain quality cine images of the heart in a single breath-hold. The technique was tested on animal models and human subjects, and the impact of interleaved acquisition on image quality was studied using quantitative and qualitative measures.  相似文献   

11.
A measure of the sharpness of vessel wall interfaces in carotid artery MRI may be useful for assessing the conspicuity of the wall's features. An edge detection technique was used to measure the signal intensity gradients in 2D time-of-flight (2D-TOF) and double-inversion recovery black-blood (DIR-BB) carotid artery images of normal subjects that were acquired at 1.5 T with 0.55 x 0.55 x 2.0-mm (0.6 mm3) acquisition voxels and zero filled to reduce the in-plane reconstructed voxel size by one half in each dimension as well as with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels and at 3.0 T with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels using surface coils. The gradient intensities of the lumen-to-background interface varied closely with the contrast-to-noise ratio of the 2D-TOF imaging. For the DIR-BB imaging, in which higher spatial frequency artery structures are visible, the gradient intensities at the interfaces were higher than theoretically predicted at both field strengths with smaller acquisition voxels. The use of acquisition voxels smaller than those previously used at 1.5 T can improve the visualization of carotid artery structures at 1.5 and 3.0 T with surface coil reception.  相似文献   

12.
BackgroundDiffusion MRI (dMRI) data acquisition protocols are well-established on modern high-field clinical scanners for human studies. However, these protocols are not suitable for the chimpanzee (or other large-brained mammals) because of its substantial difference in head geometry and brain volume compared with humans. Therefore, an optimal dMRI data acquisition protocol dedicated to chimpanzee neuroimaging is needed.MethodsA multi-shot (4 segments) double spin-echo echo-planar imaging (MS-EPI) sequence and a single-shot double spin-echo EPI (SS-EPI) sequence were optimized separately for in vivo dMRI data acquisition of chimpanzees using a clinical 3T scanner. Correction for severe susceptibility-induced image distortion and signal drop-off of the chimpanzee brain was performed and evaluated using FSL software. DTI indices in different brain regions and probabilistic tractography were compared. A separate DTI data set from n=34 chimpanzees (13 to 56 years old) was collected using the optimal protocol. Age-related changes in diffusivity indices of optic nerve fibers were evaluated.ResultsThe SS-EPI sequence acquired dMRI data of the chimpanzee brain with approximately doubled the SNR as the MS-EPI sequence given the same scan time. The quality of white matter fiber tracking from the SS-EPI data was much higher than that from MS-EPI data. However, quantitative analysis of DTI indices showed no difference in most ROIs between the SS-EPI and MS-EPI sequences. The progressive evolution of diffusivity indices of optic nerves indicated mild changes in fiber bundles of chimpanzees aged 40 years and above.ConclusionThe single-shot EPI-based acquisition protocol provided better image quality of dMRI for chimpanzee brains and is recommended for in vivo dMRI study or clinical diagnosis of chimpanzees (or other large animals) using a clinical scanner. Also, the tendency of FA decrease or diffusivity increase in the optic nerve of aged chimpanzees was seen but did not show significant age-related changes, suggesting aging may have less impact on optic nerve fiber integrity of chimpanzees, in contrast to previous results for both macaque monkeys and humans.  相似文献   

13.
High-resolution water, fat and chemical shift artefact-free images of different areas of the skin were obtained on a whole-body MR unit (1.5 T) with commercial receiver surface coil with a diameter of 25 mm and high-power gradients (23 mT/m). Sufficient signal-to-noise ratio was achieved by lowering receiver bandwidth to +/-10 kHz or lower and shortening the echo time to 11 (13) ms. Spectroscopic image data sets were acquired with resolution 0.102 x 0.133 mm in plane and slice thickness 0.5 mm. The results demonstrate that it is possible to produce high-quality water and fat micro-images of the skin layers using only a few chemical shift encoding steps in a clinically reasonable time (approximately 2 minutes per slice).  相似文献   

14.
An MR imaging technique has been developed producing head and body images of diagnostic quality in only a few seconds acquisition time. The Fourier type imaging technique uses excitation with relatively small excitation angels, echoes produced by gradient inversion, and extremely fast profile repetition. A typical result at 0.5 T is an artifact-free head image of 128 x 128 resolution, 10 mm slice thickness in an acquisition time of 2 seconds.  相似文献   

15.
PurposeSimultaneous multi-slice (SMS) imaging accelerates MRI data acquisition by exciting multiple image slices with a single radiofrequency pulse. Overlapping slices encoded in acquired signal are separated using a mathematical model, which requires estimation of image reconstruction kernels using calibration data. Several parameters used in SMS reconstruction impact the quality and fidelity of final images. Therefore, finding an optimal set of reconstruction parameters is critical to ensure that accelerated acquisition does not significantly degrade resulting image quality.MethodsGradient-echo echo planar imaging data were acquired with a range of SMS acceleration factors from a cohort of five volunteers with no known neurological pathology. Images were collected using two available phased-array head coils (a 48-channel array and a reduced diameter 32-channel array) that support SMS. Data from these coils were identically reconstructed offline using a range of coil compression factors and reconstruction kernel parameters. A hybrid space (k-x), externally-calibrated coil-by-coil slice unaliasing approach was used for image reconstruction. The image quality of the resulting reconstructed SMS images was assessed by evaluating correlations with identical echo-planar reference data acquired without SMS. A finger tapping functional MRI (fMRI) experiment was also performed and group analysis results were compared between data sets reconstructed with different coil compression levels.ResultsBetween the two RF coils tested in this study, the 32-channel coil with smaller dimensions clearly outperformed the larger 48-channel coil in our experiments. Generally, a large calibration region (144–192 samples) and small kernel sizes (2–4 samples) in ky direction improved image quality. Use of regularization in the kernel fitting procedure had a notable impact on the fidelity of reconstructed images and a regularization value 0.0001 provided good image quality. With optimal selection of other hyperparameters in the hybrid space SMS unaliasing algorithm, coil compression caused small reduction in correlation between single-band and SMS unaliased images. Similarly, group analysis of fMRI results did not show a significant influence of coil compression on resulting image quality.ConclusionsThis study demonstrated that the hyperparameters used in SMS reconstruction need to be fine-tuned once the experimental factors such as the RF receive coil and SMS factor have been determined. A cursory evaluation of SMS reconstruction hyperparameter values is therefore recommended before conducting a full-scale quantitative study using SMS technologies.  相似文献   

16.
The purpose of this study was to examine the potential of diffusion-weighted (DW) three-dimensional (3D) MP-RAGE MRI for diffusion-tensor mapping of the rat brain in vivo. A DW-3D-MP-RAGE (3D-DWI) sequence was implemented at 2.0 T using six gradient orientations and a b value of 1000 s/mm2. In this sequence, the preparation sequence with a "90 degrees RF-motion proving gradient (MPG): MPG-180 degrees RF-MPG-90 degrees RF" pulse train (DW driven equilibrium Fourier transform) was used to sensitize the magnetization to diffusion. A centric k-space acquisition order was necessary to minimize saturation effects (T1 contamination) from tissues with short relaxation time. The image matrix was 128x128x128 (interpolated from 64x64x64 acquisitions), which resulted in small isotropic DW image data (voxel size: 0.273x0.273x0.273 mm3). Moreover, 3D-DWI-derived maps of the fractional anisotropy (FA), relative anisotropy (RA) and main-diffusion direction were completely free of susceptibility-induced signal losses and geometric distortions. Two well-known commissural fibers, the corpus callosum and anterior commissure, were indicated and shown to be in agreement with the locations of these known stereotaxic atlases. The experiment took 45 min, and shorter times should be possible in clinical application. The 3D-DWI sequence allows for in vivo 3D diffusion-tensor mapping of the rat brain without motion artifacts and susceptibility to distortion.  相似文献   

17.
Spectral quality in (1)H MR spectroscopic imaging (MRSI) of the brain is often significantly degraded in regions subject to local magnetic susceptibility variations, which results in broadened and distorted spectral lineshapes. In this report, a modified acquisition strategy for volumetric echo-planar spectroscopic imaging (3D EPSI) is presented that extends the region of the brain that can be observed. The data are sampled at higher spatial resolution, then corrected for local B(0) shifts and reconstructed such that the final spatial resolution matches that of 3D EPSI data acquired with the conventional lower spatial resolution. Comparison of in vivo data obtained at 1.5 T with these two acquisition schemes shows that the high spatial resolution acquisition provides considerable reduction of spectral linewidths in many problematic brain regions, though with a reduction in signal-to-noise ratio by a factor of approximately 1.4 to 1.6 for the matrix sizes used in this study. However, the effect of the increased noise was largely offset by the improved spectral quality, leading to an overall improvement of the metabolite image quality obtained using automated spectral analysis.  相似文献   

18.
Continuous wave electron paramagnetic resonance imaging (EPRI) of living biological systems requires rapid acquisition and visualization of free radical images. In the commonly used multiple-stage back-projection image reconstruction algorithm, the EPR image cannot be reconstructed until a complete set of projections is collected. If the data acquisition is incomplete, the previously acquired incomplete data set is no longer useful. In this work, a 3-dimensional progressive EPRI technique was implemented based on inverse Radon transform in which a 3-dimensional EPR image is acquired and reconstructed gradually from low resolution to high resolution. An adaptive data acquisition strategy is proposed to determine the significance of projections and acquire them in an order from the most significant to the least significant. The image acquisition can be terminated at any time if further collection of projections does not improve the image resolution distinctly, providing flexibility to trade image quality with imaging time. The progressive imaging technique was validated using computer simulations as well as imaging experiments. The adaptive acquisition uses 50-70% less projections as compared to the regular acquisition. In conclusion, adaptive data acquisition with progressive image reconstruction should be very useful for the accelerated acquisition and visualization of free radical distribution.  相似文献   

19.
The rest period of the coronary arteries has been shown to be on the order of 120–160 msec. Restriction of the acquisition window in breath-hold cardiac-synchronized gadolinium-enhanced imaging to this duration limits the amount of sampled k-space data and hence the information when compared with conventional gadolinium-enhanced imaging. Two techniques for gadolinium-enhanced cardiac-synchronized angiography were implemented that acquire additional data during the unused portions of the cardiac cycle. Data acquisition is synchronized with the heart cycle and is restricted to a short period of each heart cycle. In a single breath-hold, a multi-slab acquisition (n = 5) allowed ECG-synchronized imaging of the entire heart or a CINE acquisition (n = 5) provided multiple stacks of images at different phases in the cardiac cycle over a smaller area. Preliminary results acquired in healthy volunteers and patients with aortic disease indicate that additional information can be acquired without an increase in breath-hold duration or a reduction in image quality.  相似文献   

20.
Objective: Magnetic resonance imaging (MRI) acquisition is inherently sensitive to motion, and motion artifact reduction is essential for improving image quality in MRI. Methods: We developed a deep residual network with densely connected multi-resolution blocks (DRN-DCMB) model to reduce the motion artifacts in T1 weighted (T1W) spin echo images acquired on different imaging planes before and after contrast injection. The DRN-DCMB network consisted of multiple multi-resolution blocks connected with dense connections in a feedforward manner. A single residual unit was used to connect the input and output of the entire network with one shortcut connection to predict a residual image (i.e. artifact image). The model was trained with five motion-free T1W image stacks (pre-contrast axial and sagittal, and post-contrast axial, coronal, and sagittal images) with simulated motion artifacts. Results: In other 86 testing image stacks with simulated artifacts, our DRN-DCMB model outperformed other state-of-the-art deep learning models with significantly higher structural similarity index (SSIM) and improvement in signal-to-noise ratio (ISNR). The DRN-DCMB model was also applied to 121 testing image stacks appeared with various degrees of real motion artifacts. The acquired images and processed images by the DRN-DCMB model were randomly mixed, and image quality was blindly evaluated by a neuroradiologist. The DRN-DCMB model significantly improved the overall image quality, reduced the severity of the motion artifacts, and improved the image sharpness, while kept the image contrast. Conclusion: Our DRN-DCMB model provided an effective method for reducing motion artifacts and improving the overall clinical image quality of brain MRI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号