首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Water-soluble multi-walled carbon nanotubes (MWNTs) were prepared by the strong adsorption of Congo red (CR) on MWNTs. The CR-functionalized MWNTs (MWNTs–CR) had a high solubility, a high purity and a special property of strong rebundling when dried, capable of forming uniform and compact MWNTs films with a 3D network structure of nanosizes on a glassy carbon electrode (GCE). Compared with GCE, the electrochemical response of estradiol at a MWNTs–CR modified glassy carbon electrode (MWNTs–CR/GCE) was greatly enhanced, which was further amplified by the addition of trace cetyltrimethylammonium bromide (CTAB) in solution, along with the accomplishment of antifouling capacity of the modified electrode. The weak hydrophobic adsorption of surfactants on the hydrophobic and smooth surface of MWNTs was found to be the key for simultaneously improving the sensitivity and antifouling capacity of carbon nanotube-based electrochemical sensors by surfactants.  相似文献   

2.
多壁碳纳米管修饰玻碳电极伏安法测定氯霉素   总被引:1,自引:0,他引:1  
研究了氯霉素(CAP)在多壁碳纳米管修饰玻碳电极上的电化学行为.发现在pH=2.0的0.1 mol/LKCl-HCl底液中,CAP在该修饰电极上有一灵敏的还原峰(Ep=-0.36 V vs.Ag/AgCl),峰电流与CAP浓度成正比,线性范围为6.0×10-6~2.7×10-4mol/L,检测限达3.0×10-6mol/L.该方法灵敏、准确,用于模拟样品和实际样品的测定,结果满意.  相似文献   

3.
A simple, sensitive, and reliable method based on a multi-walled carbon nanotubes (MWNTs) modified carbon ionic liquid electrode (CILE) has been successfully developed for determination of dopamine (DA) in the presence of ascorbic acid (AA). The acid-treated MWNTs with carboxylic acid functional groups could promote the electron-transfer reaction of DA and inhibit the voltammetric response of AA. Due to the good performance of the ionic liquid, the electrochemical response of DA on the MWNTs/CILE was better than that of other MWNTs modified electrodes. Under the optimum conditions a linear calibration plot was obtained in the range 5.0×10(-8) to 2.0×10(-4) mol L(-1) and the detection limit was 1.0×10(-8) mol L(-1).  相似文献   

4.
制备了多壁碳纳米管修饰玻碳电极,研究了对乙酰氨基酚在多壁碳纳米管修饰电极上的循环伏安行为,并建立了测定对乙酰氨基酚含量的电化学分析方法。在pH为6.89的磷酸盐缓冲液中,多壁碳纳米管修饰电极对对乙酰氨基酚有明显的电催化作用,其氧化峰电流与对乙酰氨基酚浓度在1.0×10-6~1.0×10-4mol·L-1范围内呈良好的线性关系,检测限为2.0×10-7mol·L-1。  相似文献   

5.
《Electroanalysis》2005,17(9):749-754
A sensitive electrochemical method for the determination of simvastatin (SV) was established, based on the enhanced oxidation of SV at a multi‐walled carbon nanotubes‐dihexadecyl hydrogen phosphate composite modified glassy carbon electrode (MWNTs‐DHP/GCE). The voltammetric studies showed that MWNTs instead of DHP or GCE could effectively catalyze the oxidation of SV. The dependence of oxidation current on SV concentration was explored under optimal conditions, which exhibited a good linear relationship in the range of 1.0×10?7–7.5×10?6 M. The detection limit of SV was also examined and a low value of 5.0×10?8 M was obtained for 5 min accumulation (σ=3). This electrode was applied to the detection of SV in drug forms and the results were in accordance with those obtained by UV spectroscopy.  相似文献   

6.
《Analytical letters》2012,45(8):883-893
A multi-wall carbon nanotubes (MWNTs) and cobalt(II) tetrakisphenylporphyrin (Co(II)TPP) modified glassy carbon electrode (MWNTs/Co(II)TPP/GCE) has been prepared. It can be used for individual or simultaneous determination of hydroquinone (HQ) and catechol (CC). The anodic peaks of HQ and CC can be separated well. Owing to the unique properties of MWNTs and special synergistic effect of MWNTs and Co(II)TPP, the modified electrode exhibited a remarkable and stable current response for CC and HQ. The linear ranges for CC and HQ were 1.0–450.0 µmol L?1 and 0.8–400.0 µmol L?1 with detection limits of 0.8 µmol L?1 and 0.5 µmol L?1, respectively. Furthermore, Co(II)TPP, MWNTs, and Co(II)TPP/MWNTs composite were also used to construct modified electrodes and the electrochemical performances were studied.  相似文献   

7.
The electrochemistry of xanthinol nicotinate(Xan) was studied by cyclic voltammetry at a glassy carbon electrode modified by a gel containing multi-walled carbon nanotubes(MWNTs) and room-temperature ionic liquid of 1-butyl-3-methylimidazolium hexafluorophosphate(BMTMPF_6).The modified electrode exhibited good promotion to the electrochemical oxidation of Xan and an ultrasensitive electrochemical method was proposed for the determination of Xan.This method was successfully applied to the determination of...  相似文献   

8.
We describe a biosensor for phenolic compounds that is based on a glassy carbon electrode modified with tyrosinase immobilized on multiwalled carbon nanotubes (MWNTs). The MWNTs possess excellent inherent electrical conductivity which enhances the electron transfer rate and results in good electrochemical catalytic activity towards the reduction of benzoquinone produced by enzymatic reaction. The biosensor was characterized by cyclic voltammetry, and the experimental conditions were optimized. The cathodíc current is linearly related to the concentration of the phenols between 0.4???M and 10???M, and the detection limit is 0.2???M. The method was applied to the determination of phenol in water samples.
Figure
A tyrosinase and carbon nanotubes (MWNTs) modified glassy carbon electrode was fabricated and used for the sensitive detection of phenol. The reduction peak of benzoquinone produced by enzymatic reaction of phenol was greatly enhanced due to the presence of MWNTs(c)  相似文献   

9.
《Electroanalysis》2006,18(5):485-492
A novel method for the fabrication of carbon nanotubes/poly(1,2‐diaminobenzene) nanoporous composite based electrode was proposed. By multipulse potentiostatic electropolymerization, the multi‐walled carbon nanotubes (MWNTs) and poly(1,2‐diaminobenzene) were deposited simultaneously on the electrode surface. Compared with the composite prepared by the traditional potentiodynamic method, the composite synthesized by multipulse potentiostatic method has a unique nanoporous structure, exhibits excellent conductivity and better environmental stability. The surface of the resulting electrode was characterized with scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The nanoporous composite film modified glassy carbon electrode was also used successfully for the simultaneously voltammetric determination of trace level of Cd2+ and Cu2+ at first‐time. Under the optimal conditions, the determination limits of 0.25 and 0.33 ppb for Cd2+ and Cu2+ were obtained, respectively. The calibration graphs were linear in the concentration range of 5–100 ppb. The electrode system provides an excellent platform for ultra sensitive electrochemical sensors for chemical and biological sensing.  相似文献   

10.
The fabrication of poly(2,6-pyridinedicarboxylic acid)/MWNTs modified glass electrode(PPDA/MWNTs/GCE) was proposed and used for individual or simultaneous determination of guanine and adenine.The performances of the PPDA/MWNTs/GCE were characterized with cyclic voltammetry(CV).The modified electrode exhibited enhanced electrocatalytic behavior and good stability for the detection of guanine and adenine.Differential pulse voltammetry(DPV) was used to determine the concentration of guanine,adenine.The detection limit(S/N = 3) for guanine and adenine was 0.045μmol/L and 0.05μmol/L,respectively.The electrochemical method for the measurement of guanine and adenine in calf thymus DNA was also developed with this modified electrode and the result was satisfactory.  相似文献   

11.
《Electroanalysis》2017,29(4):1049-1055
A sensitive electrochemical method for the determination and quantification of curcumin using adsorptive stripping voltammetry (AdsSV) at a multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode (MWCNT‐BPPG electrode) is presented exploiting the high surface area of the latter. Next the voltammetric behaviour of curcumin on the modified electrode is examined and AdsSV shown to be a sensitive method for quantifying curcumin. The adsorption of curcumin on the electrode surface is evidenced to follow a Langmuir adsorption isotherm. Linear calibration for curcumin in the range of 2–100 μM was obtained with a detection limit of 0.45 μM and a limit of quantification of 1.49 μM. For application to real samples of turmeric, a one‐step sample preparation in ethanol has developed providing a simple and rapid extraction procedure. The MWCNT‐BPPG electrode with AdsSV allowed the determination of curcumin equivalent in turmeric powder sample with recoveries in the range of 92–108 %. This facile and fast method will be useful for monitoring the quality of curcumin containing in commercial turmeric products.  相似文献   

12.
Electrochemical behavior of dopamine at the RuO2‐modified vertically aligned carbon nanotubes electrode was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The RuO2‐modified carbon nanotube electrode showed higher electrocatalytic activity towards the oxidation of dopamine than the MWNTs electrode in 0.10 M phosphate buffer solution. At an applied potential of +0.4 V, the RuO2/MWNTs electrode exhibited a wide detection range up to 3.6×10?3 M with detection limit of 6.0×10?8 M (signal/noise=3) for dopamine determination. Meanwhile, the optimized sensor for dopamine displayed a sensitivity of 83.8 μA mM?1 and response time of 5 s with addition of 0.20 mM dopamine. In addition, DPV experiment revealed that interfering species such as ascorbic acid and uric acid could be effectively avoided. The RuO2/MWNTs electrode presents stable, highly sensitive, favorable selectivity and fast amperometric response of dopamine.  相似文献   

13.
A sensitive electrochemical method was developed for simultaneous determination of uric acid (UA) and xanthine (XA) at a glassy carbon electrode modified with multi-wall carbon nanotubes (MWNTs) film. The oxidation peak currents of UA and XA were increased at the MWNTs film electrode significantly. The experimental parameters, which influence the peak currents of UA and XA, such as the amount of MWNTs on the glassy carbon electrode, the pH of the solution, accumulation time, and scan rate, were optimized. Under optimum conditions, the peak currents were linear to the concentration of UA over the wide range from 1 x 10(-7) mol L(-1) to 1 x 10(-4) mol L(-1) and to that of XA over the wide range from 2 x 10(-8) mol L(-1) to 2 x 10(-5) mol L(-1). The interferences studies showed that the MWNTs-modified electrode exhibited excellent selectivity in the presence of ascorbic acid, dopamine, and hypoxanthine. The proposed procedure was successfully applied to detect UA and XA in human serum without any preliminary treatment.  相似文献   

14.
《Electroanalysis》2005,17(7):630-634
Myoglobin (Myb) of horse heart is incorporated on multi‐walled carbon nanotubes (MWNTs) and immobilized at a glassy carbon (GC) electrode surface. Its electrochemical behavior and enzyme activity are characterized by employing electrochemical methods. The results indicate that MWNTs can obviously promote the direct electron transfer between Myb and electrode, and that the Myb on MWNTs behaves as an enzyme‐like activity towards the electrochemical reduction of nitric oxide (NO). Accordingly, an unmediated NO biosensor is constructed. Experimental results reveal that the peak current related to NO is linearly proportional to its concentration in the range of 2.0×10?7–4.0×10?5 mol/L. The detection limit is estimated to be 8.0×10?8 mol/L. Considering a relative standard deviation of 2.1% in seven independent determinations of 1.0×10?5 mol/L NO, this biosensor shows a good reproducibility. The biosensor based on Myb/MWNTs modified electrode can be used for the rapid determination of trace NO in aqueous solution with a good stability, nice selectivity and easy construction.  相似文献   

15.
《Analytical letters》2012,45(13):2569-2579
Abstract

A method for determination of L‐dopa by the adsorption stripping voltammetry (ASV) using a multiwalled carbon nanotubes (MWNTs)–Nafion modified glassy carbon electrode (GMGCE) was proposed. This chemically modified electrode (CME) shows a better stability. A sensitive oxidation peak was observed and the anodic peak potential is ca. 0.374V (vs. SCE). The influences of various experimental parameters on the current peak were completely studied. Under the optimized condition, the method has been applied to the determination of L‐dopa in samples. There is a good linear relationship between the peak current (ip) and L‐dopa concentration in the range of 3.5×10?7~1.5×10?5 mol/L, with the limit of detection 5.0×10?8 mol/L.  相似文献   

16.
《Electroanalysis》2006,18(11):1075-1080
The voltammetric behavior of uric acid (UA) has been studied at a multiwalled carbon nanotube‐ionic liquid (i.e., 1‐butyl‐3‐methylimidazolium hexafluorophosphate, BMIMPF6) paste coated glassy carbon electrode (MWNTs‐BMIMPF6/GC). It is found that UA can effectively accumulate at this electrode and cause a sensitive anodic peak at about 0.49 V (vs. SCE) in pH 4.0 phosphate buffer solutions. Experimental parameters influencing the response of the electrode, such as solution pH and accumulation time, are optimized for uric acid determination. Under the optimum conditions, the anodic peak current is linear to UA concentration in the range of 1.0×10?8 M to 1.0×10?6 M and 2.0×10?6 M to 2.0×10?5 M. The detection limit is 5.0×10?9 M for 180 s accumulation on open circuit. The electrode can be regenerated by successively cycling in a blank solution for about 3 min and exhibits good reproducibility. A 1.0×10?6 M UA solution is measured for eight times using the same electrode regenerated after every determination, and the relative standard deviation (RSD) of the peak current is 3.2%. As for different electrodes fabricated by the same way the RSD (i.e., the electrode to electrode deviation) is 4.2%(n=9). This method has been applied to the determination of UA in human urine samples, and the recoveries are 99%–100.6%. In addition, comparison is made between MWNTs‐BMIMPF6/GC and MWNTs/GC. Results show that the MWNTs‐BMIMPF6/GC exhibits higher sensitivity, selectivity and ratio of peak current to background current.  相似文献   

17.
Xu J  Wang Y  Xian Y  Jin L  Tanaka K 《Talanta》2003,60(6):1123-1130
A multiwall carbon nanotubes (MWNTs) film modified electrode was prepared and used as an amperometric sensor for the simultaneous determination of oxidizable amino acids including cysteine, tryptophane and tyrosine. The electrochemical behaviors of these amino acids at this modified electrode were studied by cyclic voltammetry (CV). The results indicated that the MWNTs chemically modified electrode (CME) exhibited efficient electrocatalytic activity towards the oxidation of these amino acids with relatively high sensitivity, stability and long-life. Following separation by ion chromatography (IC) with 2.0×10−3 mol l−1 citric acid buffer solution (pH 6.5) as eluent, cysteine, tryptophane and tyrosine could be determined by the MWNTs CME successfully. Under the optimal conditions, the detection limits were 7.0×10−7 mol l−1 for cysteine, 2.0×10−7 mol l−1 for tryptophane and 3.5×10−7 mol l−1 for tyrosine at the signal-to-noise of 3, respectively. The method was applied successfully to the determination of these substances in plasma.  相似文献   

18.
Multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (GCE) was simply and conveniently fabricated. The electrochemical properties of paracetamol (PCT) at the prepared modified electrode were investigated by cyclic voltammetry (CV). Based on this, an ultrasensitive and rapid electrochemical method was developed for the determination of PCT. The result indicated that the oxidation of PCT was greatly improved at the MWNTs-modified GC (MWNTs/GC) electrode as compared with the bare GC electrode, with relatively high sensitivity, stability and life time. Good linear relationship between the oxidation peak current and the PCT concentration in the range of 1 × 10−7 to 1 × 10−3 M (r = 0.996) was obtained in phosphate buffer solution (PBS) with pH 6.5, the detection limit was 2 × 10−8 M (S/N = 3) by use of modified electrode. The proposed method was successfully applied to the PCT determination in tablets.  相似文献   

19.
《Analytical letters》2012,45(9):1785-1799
Abstract

Multiwalled carbon nanotubes (MWNTs) were treated with a mixture of concentrated sulfuric and nitric acid to introduce carboxylic acid groups to the nanotubes. Conducting polymer film was prepared by electrochemical polymerization of neutral red (NR). By using a layer‐by‐layer method, homogeneous and stable MWNTs and poly (neutral red) (PNR) multilayer films were alternately assembled on glassy carbon (GC) electrodes. With the introduction of PNR, the MWNTs/PNR multilayer film system showed synergy between the MWNTs and PNR, with a significant improvement of redox activity due to the excellent electron‐transfer ability of carbon nanotubes (CNTs) and PNR. The electropolymerization is advantageous, providing both prolonged long‐term stability and improved catalytic activity of the resulting modified electrodes. The MWNTs/PNR multilayer film modified glassy carbon electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. As compared to MWNTs and PNR‐modified GC electrodes, the magnitude of the amperometric response of the MWNTs/PNR composite‐modified GC electrode is more than three‐fold greater than that of the MWNTs modified GC electrode, and nine‐fold greater than that of the PNR‐modified GC electrode. With the immobilization of glucose oxidase onto the electrode surface using glutaric dialdehyde, a biosensor that responds sensitively to glucose has been constructed. In pH 6.98 phosphate buffer, nearly interference‐free determination of glucose has been realized at ?0.2 V vs. SCE with a linear range from 50 µM to 10 mM and response time <10s. The detection limit was 10 µM glucose (S/N=3).  相似文献   

20.
《Analytical letters》2012,45(7):1236-1247
Abstract

The 6-ferrocenylhexanethiol (FcC6SH) functionalized multiwall carbon nanotubes (MWNTs) modified glassy carbon electrode (FcC6SH/MWNTs/GCE) was easily fabricated and used for the sensitive detection of NADH. Cyclic voltammetric and amperometric methods were used to study the behavior of NADH on the FcC6SH/MWNTs/GCE. A broader linear response range to the NADH concentration from 5 µM to 1.5 mM with a correlation coefficient of 0.9982 was obtained. The detection limit was 0.54 µM. The synergetic effects of FcC6SH and MWNTs make the modified electrode highly sensitive to NADH. In addition, the modified electrode can decrease the fouling of the electrode surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号