首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Aryl oxalate chemiluminescence detection for high-performance liquid chromatography offers ultrahigh sensitivity for interactive fluorophores. With optimal analytes, attomole limits of detection can be obtained with conventional instrumentation  相似文献   

2.
3.
A novel method for the simultaneous determination of phenolic compounds such as salicylic acid, resorcinol, phloroglucinol, p-hydroxybenzoic acid, 2,4-dihydroxybenzoic acid, and m-nitrophenol by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection was developed. The procedure was based on the chemiluminescent enhancement by phenolic compounds of the cerium(IV)-Tween 20 system in a sulfuric acid medium. The separation was carried out with an isocratic elution or with a gradient elution using a mixture of methanol and 1.5% acetic acid. For six phenolic compounds, the detection limits (3σ) were in the range 1.40-5.02 ng/ml and the relative standard deviations (n=11) for the determination of 0.1 μg/ml compounds were in the range 1.9-2.9%. The CL reaction was well compatible with the mobile phase of HPLC, no baseline drift often occurred in HPLC-CL detection was observed with a gradient elution. The method has been successfully applied to the determination of salicylic acid and resorcinol in Dermatitis Clear Tincture and p-hydroxybenzoic acid in apple juices.  相似文献   

4.
The chemiluminescence reaction between an aryl oxalate, hydrogen peroxide and a fluorescent compound is well known for use in h.p.l.c. post-column reactors. Here, several aryl oxalates are evaluated for this purpose in terms of intensity, rate of chemiluminescence decay, solubility in different solvents, and stability in the presence of hydrogen peroxide. Five oxalates are selected for different pH ranges of column eluates: bis(pentafluorophenyl) oxalate for pH < 2, bis(2,4-dinitrophenyl) oxalate for pH 2–4, bis(2-nitrophenyl) oxalate for pH 4–6, bis(2,4,6-trichlorophenyl) oxalate for pH 6–8, and bis(2,4,5-trichlorophenyl-6-pentyloxycarbonyl) oxalate for pH > 8.  相似文献   

5.
Ofloxacin (OFLX) exhibited strong electrogenerated chemiluminescence (ECL) in NaNO3 solution with a dual-electrode system when constant current was exerted. Based on this observation, a sensitive direct ECL method coupled with high-performance liquid chromatography (HPLC) separation was developed for determination of OFLX in human serum. Factors affected the ECL emission were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of OFLX in the range of 1.0 × 10−8 to 4.0 × 10−6 g mL−1 and the detection limit was 4 × 10−9 g mL−1 (S/N = 3). The proposed method was sensitive, simple and convenient to operate.  相似文献   

6.
A method was developed for the determination of polyamines (PA) by high-performance liquid chromatography with chemiluminescence detection. It is based on the unsaturated complex of PA with Cu(II) which had a strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The separation of PA was carried out on a reveres phase C18 column using methanol/water (25/75, v/v) as a mobile phase. The method was applied to the analysis of putrescine and the total amount of spermine and spermidine in apple leaves and strawberry fruit. The results indicated that the method is practical and useful.  相似文献   

7.
The selectivity and sensitivity of analytical response in electrochemical (amperometric and conductometric) detection methods in the high-performance liquid chromatography of organic compounds is discussed in comparison with other detection techniques. The importance of electrode materials of different nature for extending the range of analytes is noted. Presented at the V All-Russian Conference with the Participation of CIS Countries on Electrochemical Methods of Analysis (EMA-99), Moscow, December 6–8, 1999.  相似文献   

8.
A method using high-performance liquid chromatography with chemiluminescence detection was developed for analyzing mutagenic nitrobenzanthrone (NBA) isomers in airborne particulates. The method was a modification of our previously described method for analyzing nitropolycyclic aromatic hydrocarbons (NPAHs). The pretreatment and reducing conditions for 1-, 2-, 3- and 10-NBAs were the same as those for NPAHs. In order to separate these NBA isomers, we used a polymeric-type ODS column (Cosmosil 5C-18MS); a mixture of 40% acetonitrile and 60% 10 mM imidazole-HClO4 buffer was employed as the mobile phase at a flow rate of 1 mL/min. The isomers of 1-, 2-, 3- and 10-NBA were determined in chemiluminescence with linear calibration graphs from 0.1 to 4 pmol, from 200 to 4000 pmol, from 1 to 50 pmol and from 10 to 400 pmol, respectively. The detection limits (S/N = 3) of 1-, 2-, 3- and 10-NBA isomers were 0.02 pmol, 35 pmol, 0.3 pmol and 3 pmol, respectively. The method was used to analyze airborne particulates at a heavy traffic site in Kanazawa. 2- and 3-NBAs were detected in the extracts of the particulates, while 1-NBA and 10-NBA were not detected. The atmospheric concentrations of 2- and 3-NBAs were 1.83 pmol/m3 and 24.7 fmol/m3, respectively.  相似文献   

9.
Three metabolites of 1-nitropyrene, i.e., 3-hydoxy-1-nitropyrene (3-OHNP), 6-hydoxy-1-nitropyrene (6-OHNP) and 8-hydoxy-1-nitropyrene (8-OHNP), were sensitively and selectively detected by HPLC with peroxyoxalate chemiluminescence (CL) detection. In the system, the three OHNPs were reduced to their corresponding amino derivatives through a reduction column packed with Pt/Rh-coated alumina and then concentrated on a concentrator column. By rotating a switching valve, the analytes were eluted into a separator column (ODS), separated and then detected by the bis(2,4,6-trichlorphenyl)oxalate-H(2)O(2) CL system. The detection limits (signal-to-noise ratio=3) were in the range from 5fmol (6-OHNP and 8-OHNP) to 12fmol (3-OHNP) per injection. To demonstrate the proposed method, it was used to determine three compounds in the incubation mixture of 1-nitropyrene and rat S9 mix.  相似文献   

10.
Electrochemical detection in liquid chromatography was introduced in 1973 for the assay of catecholamines, the electroactive hormones and neurotransmitters, and continues to grow in popularity for the assay of trace amounts of biologically active compounds in complex samples in biology and medicine.  相似文献   

11.
A chemiluminescence reaction detector was developed for the detection of polyphenols separated by HPLC based on the inhibition of chemiluminescence from the luminol-potassium hexacyanoferrate(III) reaction by polyphenols. The separation was carried out on a RP-C18 column at 37 degrees C by using stepwise gradient elutions. The detection limits are in the range of 6.8 x 10(-7)-2.0 x 10(-9) g/ml for catechol, protocatechuic acid, chlorogenic acid, rutin, resorcinol, hydroquinone and p-tert.butylpyrocatechol. The method is sensitive, selective, fast and simple. It has been successfully applied to the determination of chlorogenic acid and rutin in real tobacco samples.  相似文献   

12.
13.
A highly sensitive method for the determination of myoglobin in serum is described, based on high-performance size-exclusion chromatography with chemiluminescence detection. Serum proteins are separated according to their molecular masses on columns packed with TSK-SW gel and those containing haem are detected selectively by post-column chemiluminescence reaction with luminol using a conventional fluorimetric detector. The method is rapid (30 min) and sufficiently sensitive for the diagnosis of myocardial infarction. The minimum detectable myoglobin concentration is 10 ng/ml.  相似文献   

14.
A simple cation-exchange chromatographic system was used to separte cobalt from other metal ions. The cobalt thus separated was detected by the luminol chemiluminescence reaction using a spectrofluorimeter as the detector. A 3σ detection limit of 0.5 ng l?1 was achieved, without the need for preconcentration, with a 200-μl sample. The system provided a linear analytical working range from 5 ng l?1 to 10 μg l?1. The cobalt content of a rice flour certified reference material was determined using the system and gave good agreement with the certificate value.  相似文献   

15.
Estradiol extracted with an ODS minicolumn from serum (500 μl) is derivatized with 5-dimethylamino-1-naphthalenesulfonyl (dansyl) chloride at room temperature for 80 min, purified on the ODS minicolumn, separated on silica gel columns (150 × 1.9 mm i.d. and 100 × 1.9 mm i.d.) with n-hexane/chloroform/ethanol (70:30:0.1) as eluent at 3 ml min?1 and detected by the chemiluminescence emission produced in a post-column reaction with bis-(2,4,6-trichlorophenyl) oxalate (8 mM in chloroform containing 100 mM triethylamine) and hydrogen peroxide (600 mM in methanol containing 6% (v/v) sodium acetate buffer at pH 4.0). The overall recovery of estradiol from serum is ca. 90% and the detection limit is ca. 50 pg.  相似文献   

16.
A sensitive method has been developed for liquid chromatographic determination of short aliphatic amines in water samples. Analytes are preconcentrated and dansylated on solid sorbents (C18 solid-phase extraction cartridges). The dansyl derivatives are chromatographed and post-column mixed with peroxyoxalate (TCPO) and H2O2 in order to perform chemiluminescence detection. Optimal results have been obtained using a sample volume of 5 ml. The method has been applied to the quantification or screening of several aliphatic amines: methylamine, ethylamine, butylamine, diethylamine, pentylamine and hexylamine. The screening procedure has been developed including also polyamines (putrescine, cadaverine, spermidine and spermine). The results obtained by using chemiluminescence (CL) detection have been compared with other detection systems (fluorescence and UV). The sensitivity can increase from 3 to 75 times respect UV detection and from 2 to 10 times respect fluorescence detection depending on the amine. The detection limits achieved were between 0.15 and 0.9 microg/l.  相似文献   

17.
Three N-substituted maleimides were tested as derivatizing reagents; N-(4-anilinophenyl) maleimide (APM) was the most favorable in terms of sensitivity and reactivity. N-Acetyl-l-cysrteine, glutathione, l-cysteine and d-penicillamine were readily converted into the adducts with APM. Picogram levels of these thiol compounds were separated and quantified.  相似文献   

18.
Indirect detection is a technically simple method to follow and quantify compounds without inherent detector response in high-performance liquid chromatography. The underlying principle can be expressed in simple equations. These equations indicate clearly how the detection sensitivity can be optimized and how disturbance effects can be avoided when the mobile phase gives detector response.  相似文献   

19.
20.
Yonghua Sun  Zhijun Xi  Zuolong Shi 《Talanta》2009,79(3):676-1696
A simple and sensitive liquid chromatographic method coupled with electrogenerated chemiluminescence (ECL) was described for the separation and quantification of naproxen in human urine. The method was based on the ECL of naproxen in basic NaNO3 solution with a dual-electrode system. Factors affected the ECL emission were investigated. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of naproxen in the range of 4.0 × 10−8 g mL−1 to 2.0 × 10−6 g mL−1 and the detection limit was 1.6 × 10−8 g mL−1 (S/N = 3). Application of the method to the analyses of naproxen in human urine proved feasible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号