首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 602 毫秒
1.
A new hyphenated technique couples supercritical fluid extraction in situ derivatization and on-line headspace solid-phase microextraction to gas chromatography-mass spectrometry (SFE in situ derivatization on-line HS-SPME-GC-MS) for the determination of paraben preservatives and polyphenolic antioxidants in cosmetics. The preservatives and antioxidants were extracted from the cosmetic matrices with supercritical carbon dioxide at a pressure of 13,840 kPa. The supercritical fluid extraction was performed at 55 °C for 10 min of static extraction then 15 min of dynamic extraction. The extractant subsequently was derivatized in situ with the silylation reagent N,O-bis(trimethylsilyl)trifluoroacetamide with 0.1% trimethylchlorosilane. The product was then adsorbed on a polyacrylate solid-phase microextraction (SPME) fiber in the headspace. Sea sand was used as a dispersive material in the SFE step. The analytical linear ranges for the preservatives and antioxidants were found to be from 10 to 1000 ng g−1 with RSD values below 7.8%. The detection limits ranged from 0.5 to 8.3 ng g−1. These results are better than those obtained by using only SPME or SFE for trace preservatives and antioxidants analysis in cosmetic matrices. The new method was successfully utilized to determine the amounts of preservatives and antioxidants in real cosmetics without the need for tedious pretreatments.  相似文献   

2.
A fast and sensitive HPLC method for analysis of cosmetic creams for hydroquinone, phenol and six preservatives has been developed. The influence of sample preparation conditions and the composition of the mobile phase and elution mode were investigated to optimize the separation of the eight studied components. Final conditions were 60% methanol and 40% water (v/v) extraction of the cosmetic creams. A C18 column (100 mm × 2.1 mm) was used as the separation column and the mobile phase consisted of methanol and 0.05 mol/L ammonium formate in water (pH=3.0) with gradient elution. The results showed that complete separation of the eight studied components was achieved within 10 min, the linear ranges were 1.0-200 μg/mL for phenol, 0.1-150 μg/mL for sorbic acid, 2.0-200 μg/mL for benzoic acid, 0.5-200 μg/mL for hydroquinone, methyl paraben, ethyl paraben and propyl paraben, butyl paraben, and good linear correlation coefficient (≥0.9997) were obtained, the detection limit was in the range of 0.05-1.0 μg/mL, the average recovery was between 86.5% and 116.3%, and the relative standard deviation (RSD) was less than 5.0% (n=6). The method is easy, fast and sensitive, it can be employed to analyze component residues in cosmetic creams especially in a quality control setting.  相似文献   

3.
A column-switching system, composed of supercritical fluid extraction (SFE) and reverse phase liquid chromatography/mass spectrometry (RPLC/MS) was constructed for on-line extraction and reverse-phase separation of capsaicinoids in capsicum fruits.  相似文献   

4.
Headspace solid phase microextraction (HS-SPME) in-situ supercritical fluid extraction (SFE) was investigated for the determination of trace amounts of perfluorocarboxylic acids (PFCAs) in sediments. Quantitation was performed by using gas chromatography coupled to negative chemical ionization-tandem mass spectrometry (GC-NCI-MS/MS). The optimum conditions of HS-SPME following SFE were obtained using 500 μL n-butanol as a derivatization reagent in supercritical carbon dioxide with static extraction for 10 min, then dynamic extraction for 20 min at 30 MPa and 70 °C and simultaneous collected with 100 μm film thickness PDMS fiber. The linear range of proposed method was from 5 to 5000 ng g(-1), with limit of detection ranging from 0.39 to 0.54 ng g(-1) and limit of quantitation ranging from 1.30 to 1.80 ng g(-1). The developed method was successfully applied to analyze PFCAs in sediments from rivers and beach near industrial areas. The concentrations of PFCAs determined are from 282 to 4473 ng g(-1).  相似文献   

5.
采用液相微萃取/气相色谱-质谱联用测定食品中的四种防腐剂和三种抗氧化剂。优化后的萃取条件为:2.0μL甲苯作萃取剂,微液滴在样品中深度为0.85cm,搅拌速度800r/min,萃取时间25min,溶液的pH=3,加入盐的质量浓度为10%。该方法线性范围为0.5~400mg/kg,检出限0.01~1.2mg/kg,加标回收率93.7%~113.4%,相对标准偏差2.7%~8.6%。  相似文献   

6.
HPLC method for quantitative determination of four preservatives and nine UV filters worldwide authorized in commercial suncare product was developed and validated, and then 101 samples of commercial suncare products were analyzed for the UV filters and preservatives using the proposed method. The mobile phase was acetonitrile-water containing 0.5% acetic acid using a gradient elution at a flow rate of 0.9 mL/min and UV measurements were carried out at 320 nm for UV filters and 254 nm for preservatives. The correlation coefficients of each calibration curves were mostly higher than 0.999. The percent relative standard deviations (%RSD) ranged from 0.97% to 6.1% for five sample aliquots. The recoveries from the spiked solutions were 98-102%. 2-ethylhexyl-p-methoxycinnamate (EHMC) was detected in 96 of 101 commercial suncare products and the concentration was in the range of 3.08-8.16% and 18 samples were found to exceed the 7.5% which has been defined as the maximum allowed concentration in Korea. Methyl paraben was detected in 81 of 101 samples and the next-most often detected preservatives were propyl paraben (25), ethyl paraben (18), and butyl paraben (4). Three samples of 101 suncare products exceeded the maximum allowed concentration (i.e., 0.58-0.79%). The proposed HPLC method allows efficient and simultaneous analysis of preservatives and UV filters suitable for quality control assays of commercial suncare products.  相似文献   

7.
This study describes the development of a new method for determining p-hydroxybenzoic esters (parabens) in house dust. This optimised method was based on the pressurised hot water extraction (PHWE) of house dust, followed by the acetylation of the extracted parabens, stir bar sorptive extraction (SBSE) with a polydimethylsiloxane stir bar, and finally analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The combination of SBSE and PHWE allows the analytes to be preconcentrated and extracted from the aqueous extract in a single step with minimal manipulation of the sample. Furthermore the in situ acetylation of parabens prior to SBSE improved their extraction efficiency and their GC-MS signal. The method showed recoveries of between 40 and 80%, good linearity, repeatability and reproducibility (<10% RSD, at 100 ng g(-1), n=5), low limits of detection (from 1.0 ng g(-1) for propyl paraben to 2.1 ng g(-1) for methyl paraben) and quantification (from 3.3 ng g(-1) for propyl paraben to 8.5 ng g(-1) for methyl paraben). The proposed method was applied to the analysis of house dust samples. All the target parabens were found in the samples. Methyl and propyl parabens were the most abundant, with concentrations up to 2440 ng g(-1) and 910 ng g(-1), respectively. The high levels of parabens found in the samples confirm the importance of determining organic contaminants in indoor environments.  相似文献   

8.
De Rossi A  Desiderio C 《Electrophoresis》2002,23(19):3410-3417
A fast capillary electrochromatographic method was developed for the analysis of paraben preservatives in drugs and cosmetics in the presence of their main metabolite and/or impurity, 4-hydroxybenzoic acid. The separation was optimized in a 75 num ID capillary, fully packed with 5 num C18 stationary phase, studying the effects of mobile phase pH and composition (buffer type and organic solvent content). The mobile phase 5 mM ammonium formate, pH 3.0, containing 65% acetonitrile allowed us to obtain the baseline separation of methyl-, ethyl-, propyl-, butyl-, and benzylparabens from a mixture in less than 2.5 min with repeatability and linearity using the short-end injection method (8 cm separation capillary effective length). Under the optimum experimental conditions, the method provided high separation efficiency for parabens, in the range of 129 312-140 325 number of theoretical plates per meter, and analyte quantitation limits (LOQs) in the range of 1.25-2.50 nug/mL. The method was successfully applied to the quantitative analysis of paraben preservatives in pharmaceutical and cosmetic industrial samples with direct injection or after reduced sample pretreatment.  相似文献   

9.
建立了液相色谱-四级杆飞行时间串联质谱联用技术同时测定4种甜味剂(安赛蜜、糖精钠、甜蜜素、阿斯巴甜)及2种抗氧化剂(叔丁基对苯二酚、丁基羟基茴香醚)的方法.试验采用Extend-C18色谱柱分离与ESI(-)检测,以乙腈-1 mmol/L乙酸铵为流动相梯度洗脱,在6 min内实现6种目标物的快速分离,检测限为0.250 0~5.00 0 ng/m L,日间精密度小于10.71%(n=3),液态样品平均回收率为83.24%~118.3%.方法准确、灵敏,可快速检测食品中的甜味剂和抗氧化剂.  相似文献   

10.
Cheng YC  Wang CC  Chen YL  Wu SM 《Electrophoresis》2012,33(9-10):1443-1448
This study proposes a capillary electrophoresis method incorporating large volume sample stacking, EOF and sweeping for detection of common preservatives used in cosmetic products. The method was developed using chemometric experimental design (fractional factorial design and central composite design) to determine multiple separation variables by efficient steps. The samples were loaded by hydrodynamic injection (10 psi, 90 s), and separated by phosphate buffer (50 mM, pH 3) containing 30% methanol and 80 mM SDS at -20 kV. During method validation, calibration curves were found to be linear over a range of 5-100 μg/mL for butyl paraben and isobutyl paraben; 0.05-10 μg/mL for ethyl paraben; 0.2-50 μg/mL for dehydroacetic acid; 0.5-70 μg/mL for methyl paraben; 5-350 μg/mL for sorbic acid; 0.02-450 μg/mL for p-hydroxybenzoic acid and 0.05-10 μg/mL for salicylic acid and benzoic acid. The analytes were analysed simultaneously and their detection limits (S/N = 3) were down to 0.005-2 μg/mL. The analysis method was successfully used for detection of preservatives used in commercial cosmetics.  相似文献   

11.
This study aimed to establish a rapid analytical method to determine antioxidants in essence. A simple,efficient and practical, vortex-assisted, cloud-point extraction(VACPE) procedure is proposed for extracting and pre-concentrating four different of synthetic phenolic antioxidants(SPAs), propyl gallate(PG), tert-butylhydroquinone(TBHQ), butylated hydroxyanisole(BHA), butylated hydroxytoluene(BHT) in essence prior to high performance liquid chromatography(HPLC) analysis. The non-ionic surfactant, fatty alcohol polyoxyethylene ether-9(AEO-9), was used as extractant and vortex-mixing was utilized to reduce extraction time and improve extraction efficiency. The effective parameters of the extraction process, such as volume of extraction solvent, pH, vortex-mixing time, equilibration temperature and time, were optimized. Under the optimum conditions, the linear range of PG, TBHQ,BHA and BHT was 8.0–800 ng/mL. All correlation coefficients of the calibration curves were higher than0.996 and relative standard deviations(RSD, n = 5) were 2.36%–5.46%. The proposed method was successfully applied to the extraction and determination of antioxidants in essence samples with satisfactory relative recoveries of 89.4%–103.5%. The results confirmed the SPAs of essence could be effectively monitored by this method and also established good reference criteria for essence.  相似文献   

12.
In this contribution, the performance of three different extraction procedures towards the extraction of antioxidants from rosemary (Rosmarinus officinalis) is presented. Namely, pressurized liquid extraction (PLE), using water and ethanol as solvents, supercritical fluid extraction (SFE), using neat CO2 and supercritical CO2 modified with ethanol, as well as a novel extraction process called Water Extraction and Particle formation On-line (WEPO) are directly compared. Different extraction conditions including temperatures, times and pressures have been studied. The produced extracts have been characterized in terms of extraction yield, antioxidant activity (using the DPPH radical scavenging method) and total phenols (using the Folin method). Besides, all the extracts have been chemically characterized using a new quantitative UPLC-MS/MS method. This method allowed the determination of the main antioxidants present in rosemary, including, among others, rosmarinic acid, carnosic acid and carnosol, attaining detection limits as low as 2 ng/mL. The results obtained in this study show that PLE using ethanol at high temperatures (200 °C) was able to produce extracts with high antioxidant activity (EC50 8.8 μg/mL) and high yield (ca. 40%) while efficiently extracting antioxidants of diverse polarity, among them, carnosic and rosmarinic acids, regarded as the most important antioxidants present in rosemary. Nevertheless, in this work, the ability of the three studied environmentally friendly extraction techniques to obtain bioactives from natural sources is demonstrated.  相似文献   

13.
Matrix solid-phase extraction has been successfully applied for the determination of multi-class preservatives in a wide variety of cosmetic samples including rinse-off and leave-on products. After extraction, derivatization with acetic anhydride, and gas chromatography–mass spectrometry analysis were performed. Optimization studies were done on real non-spiked and spiked leave-on and rinse-off cosmetic samples. The selection of the most suitable extraction conditions was made using statistical tools such as ANOVA, as well as factorial experimental designs. The final optimized conditions were common for both groups of cosmetics and included the dispersion of the sample with Florisil (1:4), and the elution of the MSPD column with 5 mL of hexane/acetone (1:1). After derivatization, the extract was analyzed without any further clean-up or concentration step. Accuracy, precision, linearity and detection limits were evaluated to assess the performance of the proposed method. The recovery studies on leave-on and rinse-off cosmetics gave satisfactory values (>78% for all analytes in all the samples) with an average relative standard deviation value of 4.2%. The quantification limits were well below those set by the international cosmetic regulations, making this multi-component analytical method suitable for routine control. The analysis of a broad range of cosmetics including body milk, moisturizing creams, anti-stretch marks creams, hand creams, deodorant, shampoos, liquid soaps, makeup, sun milk, hand soaps, among others, demonstrated the high use of most of the target preservatives, especially butylated hydroxytoluene, methylparaben, propylparaben, and butylparaben.  相似文献   

14.
小白菜中残留虫酰肼的超临界流体萃取条件的研究   总被引:7,自引:0,他引:7  
杨立荣  张兴  陈安良  李广泽 《色谱》2004,22(3):263-266
将超临界流体萃取(supercritical fluid extraction,SFE)技术与高效液相色谱分析相结合,建立了特异性杀虫剂虫酰肼的萃取分离方法。SFE对虫酰肼的萃取条件:压力48.3 MPa(7000 psi),温度60 ℃,静态萃取时间20 min,CO2体积10 mL,改性剂甲醇添加量0.04 mL/g,丙酮为收集溶剂。在此条件下,SFE对虫酰肼的萃取率为100.75%,所得样品可直接用于高效液相色谱分析。色谱条件:紫外-二极管阵列检测器(检测波长为245 nm),C18键合色谱柱,乙腈  相似文献   

15.
A stability-indicating, robust, fast, and user friendly reversed-phase high-performance liquid chromatographic (RP-HPLC) assay method has been developed and validated for the analysis of commercial raw material batches of methylparaben, ethylparaben, propylparaben, and butylparaben. These four parabens are widely used as preservatives in pharmaceutical and cosmetic products. Accurate assay value of each of the parabens in their respective commercial lots is critical to determine the correct weight of the paraben that is needed to obtain the target concentration of the paraben in a specific lot of pharmaceutical or cosmetic products. Currently, there are no single HPLC assay methods (validated as per ICH requirements) available in the literature that can be used to analyze the commercial lots of each of the four parabens. The analytical method reported herein analyzes all four parabens in less than 10 min. The method presented in this report was successfully validated as per ICH guidelines. Therefore, this method can be implemented in QC laboratories to analyze and assay the commercial bulk lots of the four parabens.  相似文献   

16.
Evodiamine and rutaecarpine have been intensively studied due to their pharmacological actions and clinical applications. In this report, supercritical fluid was used to extract evodiamine and rutaecarpine from the unripe fruit of Evodia rutaecarpa. Response surface methodology using Box-Behnken experimental design was utilized to optimize parameters for supercritical carbon dioxide extraction with methanol as co-solvent. The effect of various values of dynamic extraction time (30-90min), temperature (50-70°C) and pressure (200-400bar) on extraction yields of the two compounds was evaluated. Determinations of the extracts were performed by high-performance liquid chromatography. The experimental data obtained were fitted to second-order polynomial equations and analyzed by analysis of variance. The highest yields predicted were 1.217mg/g for evodiamine and 0.969mg/g for rutaecarpine at the optimal values (time 78min, temperature 62°C, pressure 280bar and co-solvent flow rate 0.4mL/min), based on the selected range of experimental conditions.  相似文献   

17.
Recently, supercritical fluid chromatography coupled to mass spectrometry has gained attention as a fast and useful technology applied to the carotenoids analysis. However, no reports are available in the literature on the direct online extraction and determination by supercritical fluid extraction with chromatography and mass spectrometry. The aim of this research was the development of an online method coupling supercritical fluid extraction and supercritical fluid chromatography for a detailed targeted native carotenoids characterization in red habanero peppers. The online nature of the system, compared to offline approaches, improves run‐to‐run precision, enables the setting of batch‐type applications, and reduces the risks of sample contamination. The extraction has been optimized using different temperatures, starting from 40°C up to 80°C. Multiple extractions, until depletion, were performed on the same sample to evaluate the extraction yield. The range of the first extraction yield, carried out at 80°C, which was the best extraction temperature, was 37.4–65.4%, with a %CV range of 2–12. Twenty‐one targeted analytes were extracted and identified by the developed methodology in less than 17 min, including free, monoesters, and diesters carotenoids, in a very fast and efficient way. Quantification of the β‐carotene was carried out by using the optimized conditions.  相似文献   

18.
A multiresidue analytical method for the determination of emerging pollutants belonging to personal care products (PCPs) (antimicrobials, preservatives), benzotriazole UV stabilizers (BUVSs) and organophosphorus compounds (OPCs) in fish has been developed using high speed solvent extraction (HSSE) followed by silica gel clean up and ultra fast liquid chromatography coupled with tandem mass spectrometry (UFLC–MS/MS) analysis. Developed extraction and clean up method yielded good recovery (>70%) for all the four groups of emerging pollutants, i.e. antimicrobials (78.5–85.6%), preservatives (85.0–89.4%), BUVSs (70.9–112%) and OPCs (81.6–114%; except for TEP – 68.9% and TPeP – 58.1%) with RSDs ranging from 0.7 to 15.4%. Intra- and inter-day repeatabilities were less than 19.8% and 19.0%, respectively at three spiked levels. The concentrations were given in lipid weight (lw) basis, and the method detection limits were achieved in the lowest range of 0.001–0.006 ng g−1 for two antimicrobials, 0.001–0.015 ng g−1 for four preservatives, 0.0002–0.009 ng g−1 for eight BUVSs and 0.001–0.014 ng g−1 for nine OPCs. Finally, the method was successfully validated as a simple and fast extraction method for the determination of 23 compounds belonging to PCPs, BUVSs and OPCs and applied to the analysis of three species of fish from Manila Bay, the Philippines. Concentrations ranged from 27 to 278 ng g−1 for antimicrobials, 6.61 to 1580 ng g−1 for paraben preservatives, −1 for BUVSs and ND (not detected) to 266 ng g−1 for OPCs suggesting the ubiquitous contamination by these emerging pollutants in Manila Bay. This is the first method developed for the determination of triclocarban, four paraben preservatives and four BUVSs, in fish.  相似文献   

19.
A rapid supercritical fluid extraction (SFE) procedure for the isolation of five of the most common sunscreen agents (2-ethylhexyl-p-dimethylaminobenzoate, 2-hydroxy-4-methoxybenzophenone, 2-ethylhexyl-p-methoxycinnamate, 4-methylbenzylidene camphor and 4-tert.-butyl-4′-methoxydibenzoylmethane) from cosmetic products is described. Investigation of the factors affecting the extraction efficiency in SFE indicated that sunscreen recoveries were affected mainly by the supercritical CO2 pressure and by the trapping method. The sunscreens were analyzed by reversed-phase high-performance liquid chromatography after a 10-min extraction of the cosmetic product with CO2 at 250 bar and 40°C, using sequential glass surface and C18 sorbent as collection system. A quantitative comparison of SFE with a liquid extraction procedure was performed on commercial cosmetics. The SFE method yielded recoveries higher than 94.8% compared with conventional liquid extraction and exhibited a precision better than 5.3% relative standard deviation. Moreover, SFE minimized sample handling, reduced the consumption of harmful solvents and afforded a more effective purification of the cosmetic matrices.  相似文献   

20.
In this work, a simple isocratic reversed-phase HPLC method for determination of alpha-tocopherol in human erythrocytes has been developed and validated. After separation of plasma the erythrocytes were washed three times with 0.9% sodium chloride containing 0.01% butylated hydroxytoluene (BHT) as antioxidant and then were diluted 1:1 (v/v) with the same solution. In the liquid-liquid extraction (LLE) procedure, 2500 microL of n-hexane was added to 500 microL of erythrocytes. After 2 min this mixture was deproteinized by addition of cool ethanol (500 microL, 5 min) denatured with 5% methanol containing alpha-tocopherol acetate (20 micromol L(-1)), as internal standard, and then extracted for 5 min by vortex mixing. After centrifugation (10 min, 1600xg) an aliquot (2000 microL) of the clean extract was separated and evaporated under nitrogen. The residue was dissolved in 400 microL methanol and analysed by reversed-phase HPLC on a 4.6 mmx150 mm, 5 microm Pecosphere C18 column; the mobile phase was 100% methanol, flow rate 1.2 mL min(-1). The volume injected was 100 microL and detection was by diode-array detector at a wavelength of 295 nm. The extraction recovery of alpha-tocopherol from human erythrocytes was 100.0+/-2.0%. The detection limit was 0.1 micromol L(-1) and a linear calibration plot was obtained in the concentration range 0.5-20.0 micromol L(-1). Within determination precision was 5.2% RSD (n=10), between determination precision was 6.1% RSD (n=10). The method was applied successfully in a clinical study of patients with acute pancreatitis and for determination of the reference values in the healthy Czech population.  相似文献   