首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A headspace solid-phase micro-extraction (HS-SPME) method was developed and optimized for gas chromatographic separation and determination of commonly found organotin compounds in human urine after potential exposure. Butyl- and phenyltin compounds were in situ derivatized to ethylated derivatives by sodium tetraethylborate (NaBEt4) directly in the urine matrix. The relevant parameters affecting the yield of the SPME procedure were examined using tetrabutyltin as internal standard. The method was optimized for direct use in the analysis of undiluted human urine samples and mono-, di- and tri-substituted butyl- and phenyltin compounds could be determined after a 15-min headspace extraction time at room temperature. The selectivity of the microwave-induced plasma atomic emission detector (MIP-AED) as an element specific detector in combination with the relatively selective sample preparation technique of HS-SPME allowed the interference-free detection of the organotin compounds in all cases. A quadrupole mass spectrometer was used in parallel experiments as a detector for the confirmation of the identity molecular structure of the eluted compounds. The performance characteristics of the developed method are given for the determination of mixtures of these compounds. Finally the proposed method was applied to the analysis of several human urine samples.  相似文献   

2.
A new sample preparation and preconcentration technique – solid phase microextraction (SPME) – is reported for the application of several tinorganic compounds and tetrabutyllead in aqueous samples. The solvent-free procedure is rapid in comparison with liquid-liquid extraction or SFE but also sensitive. Analytical variables of the extraction such as adsorption and desorption time, stirring rate and temperature has been investigated. The determination has been performed by GC coupled with atomic emission detection (AED). After optimization of the conditions of SPME a calibration was realized on the basis of a multicomponent standard solution, prepared by ethylation of organotin salts directly in the sample using sodium tetraethylborate (NaBEt4) without prior separation of the analytes from the matrix. The method permits preconcentration. Values of about 10 can be reached. A detection limit of 0.09 pg Sn and 0.08 pg Pb can be achieved under optimized conditions. The proposed procedure has been successfully applied to the analysis of organotin compounds in various slurry samples.  相似文献   

3.
Summary A rapid, simple and sensitive method has been developed for the simultaneous determination of butyl- and phenyltin species in environmental waters. The ionic organotin compounds are ethylated in the aqueous phase using sodium tetraethylborate (NaBEt4) and extracted with hexane. A 25 l aliquot of the extract is injected at a low temperature into a Tenax filled liner. After solvent venting the analytes are transferred onto the capillary column using programmed temperature vaporization (PTV) injection. Detection is done by means of a microwave induced plasma atomic emission detector (MIP AED). The method allows the determination of butyl- and phenyltin compounds in water samples down to the level of 0.1 ng/l (as Sn) while 50 ml of sample is sufficient for analysis. The accuracy of the method was confirmed by GC-AAS after chelation and Grignard derivatization.  相似文献   

4.
A fast and simple procedure is presented for the simultaneous leaching of butyl (mono, di and tributyl) and phenyl organotin species from sediment samples. Leached compounds are further ethylated with sodium tetraethylborate in aqueous medium, and analyzed by gas chromatography. After testing the stability of triphenyltin under different extraction conditions, ultrasound-assisted leaching at room temperature in the presence of acetic acid was been proposed as an extraction procedure compatible with the simultaneous determination of phenyl- and butyltin compounds in sediments. Recoveries between 70 and 90% were obtained for phenyl species in spiked samples prepared in the laboratory. Results for butyltin species were validated by use of the reference material PACS-2. Quantification limits, using GC–MIP–AES as measurement technique, were approximately 5–10 ng g–1. Precision in the consecutive analysis of three sediment samples varied between 3 and 10%. Received: 16 January 2001 / Revised: 12 March 2001 / Accepted: 13 April 2001  相似文献   

5.
Citric acid was thermochemically esterified onto defatted cotton fibre to produce a carboxyl cotton chelator (CCC), which had been used for extraction of copper prior to its determination by flame atomic absorption spectrometry. The extraction of copper has been studied under both batch and column methods. Quantitative extraction of copper was achieved in the pH range 4–7. The time needed to extract each sample was less than 30 min by the batch method. The copper extraction capacity of CCC was found to be 22.7 mg g−1 at optimal pH value. The elution was quantitative with 1 mol L−1 hydrochloric acid. The feasible flow rate of copper-containing solution for quantitative extraction onto the column packed with CCC was 0.5–4.0 mL min−1, whereas for elution it was less than 1.5 mL min−1. A 100-fold extraction factor could be achieved under the optimal column conditions. The tolerance limits for common metal ions on the extraction of copper and the time of column reuse were investigated. The proposed method has been successfully applied for extraction and determination of copper in industrial wastewater and natural water samples.  相似文献   

6.
Ethyl glucuronide (EtG) analysis in hair is a suitable method for the retrospective determination of previous alcohol consumption. According to the German guidelines, EtG abstinence is improbable at c EtG > 7 pg/mg in the proximal 3 cm of scalp hair. The chromatography of the routinely used liquid chromatography-tandem mass spectrometry procedure was optimized by replacing the stationary phase. To simplify sample preparation, two different mills were tested, and an optimized grinding process was developed. The new method was successfully validated according to the guidelines of the German Society of Toxicological and Forensic Chemistry. Despite a simple extraction procedure without any cleaning steps, a very high sensitivity (limit of detection, 1.7 pg/mg; limit of quantitation, 2.3 pg/mg) could be achieved. Competitive analysis showed significantly higher EtG concentrations in pulverized versus cut hair samples. The strong impact of sample preparation on the determined EtG concentrations suggests the introduction of a standardized sample preparation method to produce comparable results.  相似文献   

7.
 Yttrium-doped BaTiO3 ceramics have been studied as a potential material for positive temperature coefficient resistors (PTCR). The mechanism of Y incorporation into BaTiO3 plays an important role for displaying good electrical properties. Determination of the amount of yttrium in the BaTiO3 as well as microstructure characterization of the samples were performed using SEM, EDS and WDS analysis. An optimized trace element WDS quantitative analysis was applied to determine elemental concentrations for Ba, Ti and Y in the samples as accurately as possible. BaTiO3 and Y2O3 were used as standards. Analysis was undertaken using a JEOL JXA 840A electron probe microanalyzer. WDS X-ray intensity measurements were performed under 20 kV, 50 nA beam current and 0.2% preset standard counting deviation (σc) using a PET crystal. Measured k-ratios were quantified by ZAF matrix correction. Average results of WDS quantitative analysis showed 20.17 ± 0.08 at % Ti, 19.95 ± 0.09 at % Ba, 0.22 ± 0.03 at % Y, and 59.66 at % O. The results suggest incorporation of yttrium in the BaTiO3 preferentially at the Ba-sites, however partial incorporation of Y at Ti-sites could not be excluded.  相似文献   

8.
Hongmei Jiang  Bin Hu 《Mikrochimica acta》2008,161(1-2):101-107
A new method of direct single-drop microextraction combined with electrothermal atomic absorption spectrometry (ETAAS) is presented for the determination of trace Cd and Pb with dithizone (H2DZ) as chelating reagent. Factors influencing the microextraction efficiency and determination, such as pH, microdrop volume, stirring rate, extraction time were evaluated. Under the optimized experimental conditions, the detection limits of the method are 2 and 90 pg mL−1 for Cd and Pb, and the relative standards deviations for 0.5 ng mL−1 Cd and 10 ng mL−1 Pb are 11 and 12.8%. After 10 min of extraction, the enrichment factors for Cd and Pb are 118 and 90, respectively. The results for the determination of Cd and Pb in tap water, spring water, river water, pond water, lake water and spiked water samples demonstrate the accuracy, recovery and applicability of the method. An environmental water certified reference material (GSBZ 50009-88) was analyzed, and the determined values are in a good agreement with the certified values. Correspondence: Bin Hu, Department of Chemistry, Wuhan University, Wuhan 430072, P.R. China  相似文献   

9.
A new extraction method for the determination of tributyltin (TBT), dibutyltin (DBT) and monobutyltin (MBT) in sediments based on extraction with tartaric acid and methanol has been developed. Tin species were extracted from sediment samples using focused microwave technology, then ethylated with sodium tetraethylborate (NaBEt4) and analyzed by isotope dilution (ID) gas chromatography-mass spectrometry (GC-MS). The advantages of such methodology in comparison with other established extraction methods for the routine speciation analysis of organotin compounds are discussed with respect to sulfur interferences co-extracted from complex matrices.Interferences from elemental sulfur are normally found with acetic acid extraction, but with tartaric acid extraction these interferences were eliminated, demonstrating selective extraction.The accuracy of the analytical procedure was established by analyzing a certified reference material (CRM) (PACS-2, marine sediment) and comparing the results to the certified values. Good agreement between determined and certified values for butyltin compounds was obtained. Finally, some complex sediment samples collected from San Vicente's Bay, Chile, were analyzed with the proposed methodology, demonstrating its potential value for monitoring butyltins in environmental samples with high concentrations of sulfur compounds.  相似文献   

10.
This paper describes determination of the deoxynivalenol and ergosterol in samples from different varieties of barley and, consequently, malt produced from this barley. In total, 20 samples of barley and 20 samples of barley malt were analyzed. The alkaline hydrolysis with consequent extraction into hexane was applied to obtain the ergosterol from cereals. Extraction to acetonitrile/water and subsequent solid-phase extraction (SPE) were used for deoxynivalenol. The determination of the samples was performed on high-performance liquid chromatography using UV detection (ergosterol) and mass spectrometric detection (deoxynivalenol). The influence of the malting process on the production of two compounds of interest was assessed from obtained results. Ergosterol concentration ranged 0.88–15.87 mg/kg in barley and 2.63–34.96 mg/kg in malt, where its content increased to 95% compared to samples before malting. The malting process was observed as having a significant effect on ergosterol concentration (P = 0.07). The maximum concentration of deoxynivalenol was found to be 641 μg/kg in barley and 499 μg/kg in malt. Its concentration was lower than the legislative limit for unprocessed cereals (1,250 μg/kg). The statistic effect of the malting process on deoxynivalenol production was not found. Linear correlation between ergosterol and deoxynivalenol content was found to be very low (barley R = 0.02, malt R = 0.01). The results revealed that it is not possible to consider the ergosterol content as the indicator of deoxynivalenol contamination of naturally molded samples.  相似文献   

11.
 A simple, sensitive and selective kinetic spectrofluorimetric determination of NO2 sampled by the droplet method in the atmosphere was proposed on the basis of the reaction of safranin O with nitrite. By this reaction, a diazonium salt is formed, which causes a fluorescent reddish-orange dye color of the solution to change into a non fluorescent blue color. The reaction was monitored fluorimetrically by measuring the decrease in fluorescence intensity of safranin O at (λexem = 536 nm/579 nm) by a fixed-time method. The experimental conditions were optimized. Under the optimum conditions in the concentration range of 7.5–400 ng/ml, a linear calibration curve (r2 = 0.9978) was obtained with a detection limit of 7.5 ng/ml. The method was applied successful ly to the determination of nitrite in spiked water and NO2 in the atmosphere, as sampled by a liquid droplet method. Received August 23, 1999. Revision February 29, 2000.  相似文献   

12.
A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 μm PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L−1 in water and close to ng (Sn) kg−1 in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME–GC–PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.  相似文献   

13.
A sensitive and reliable method using capillary zone electrophoresis with UV-diode array detection has been developed and validated for trace determination of residues of sulfonylurea herbicides in environmental water samples and grapes from different origins. The analytes included are triasulfuron, rimsulfuron, flazasulfuron, metsulfuron-methyl, and chlorsulfuron. Optimum separation has been achieved on a 48.5-cm × 50-μm (effective length 40 cm) bubble cell capillary using 90 mM ammonium acetate buffer, pH 4.8, by applying a voltage of 20 kV at 25 °C and using p-aminobenzoic acid as the internal standard. In order to increase sensitivity, large volume sample stacking with polarity switching has been applied as on-line preconcentration methodology. For water samples, a solid-phase extraction (SPE) procedure based on the use of Oasis HLB cartridges was applied for off-line preconcentration and cleanup. For grape samples, the SPE procedure was achieved with C18 sorbent, after extraction of the compounds with MeOH:H2O (1:1) by sonication. The limits of detection for the studied compounds were between 0.04 and 0.12 μg/L for water samples and 0.97 and 8.30 μg/kg in the case of grape samples, lower in all cases than the maximum residue limits permitted by the EU for this kind of food. The developed methodology has demonstrated its suitability for the monitoring of these residues in environmental water and grape samples with high sensitivity, precision, and satisfactory recoveries.  相似文献   

14.
 In this study the reference intervals for folate and vitamin B12 were estimated according to the National Committee for Clinical Laboratory Standards Approved Guideline C28-A and International Federation of Clinical Chemistry recommendations. The study included 155 women and 124 men between ages 18–40. The health status was confirmed by history, physical examination and a questionnaire. The central 95% reference intervals of serum folate and vitamin B12 for women, determined non-parametrically, were found to be 3.9–18.1 ng/ml and 101–666.7 pg/ml, respectively. The reference values of serum folate and vitamin B12 for men were also found to be 2,5–17.6 ng/ml and 100–699.57 pg/ml, respectively. We did not observe subclass differences between females and males. Received: 15 April 2000 · Accepted: 15 April 2000  相似文献   

15.
Microwave-assisted leaching of organotin compounds from sediment samples followed by the simultaneous extraction-derivatization of the extracted species was revisited with the goal to compare the existing procedures, improve their recoveries and extend them to phenyltin compounds. The stability of butyl- and phenyltin compounds under microwave field, real recoveries of the whole analytical procedure, effect of the extraction solvent, and the necessity for an internal standard were evaluated using two candidate reference sediments. The combination of the optimized sample preparation procedure with multicapillary chromatography resulted in a rapid (2 min leaching + 5 min extraction-derivatization + 3 min chromatographic separation) and efficient analytical procedure for speciation analysis of organotin compounds in sediment samples. The detection limit achieved with a microwave-induced plasma atomic emission detector was 2 ng g–1. Received: 27 July 1998 / Revised: 31 August 1998 / Accepted: 4 September 1998  相似文献   

16.
The aqueous instability of pyrethroids and other compounds usually found in commercial pesticide formulations has been demonstrated in this work. Several types of sample treatment have been studied to avoid analyte losses during sample manipulation and storage. Analysis was performed by SPME–GC–MS. Addition of sodium thiosulfate to tap water prevented pyrethroid degradation as a result of oxidation by free chlorine. The amount added was optimized to minimize the effect of the salt on the analytical results. Analysis of samples that had been stored at 4 °C for several days revealed loss of some of the pyrethroids in the first period of storage. The effect of freezing the samples was studied and it was confirmed that samples could be stabilized for at least one week by freezing. Finally, addition of a miscible organic solvent, for example acetone, led to improvement of the analytical precision. The quality of the SPME–GC–MS method was studied. Linearity (R > 0.993), repeatability (RSD < 15%), and sensitivity (detection limits between 0.9 and 35 pg mL−1) were good. When the procedure was applied to real samples including run off and waste water some of the target compounds were identified and quantified.   相似文献   

17.
A procedure for the determination of benzene, toluene, ethylbenzene and o-xylene, m-xylene and p-xylene (BTEX) in occupational environments is proposed. These compounds are extracted from activated charcoal using accelerated solvent extraction. Operational parameters are optimized and quantitative recovery is obtained using acetonitrile as the extraction solvent and 1-mL extraction cells, a preheat time of 2 min, a temperature of 160 °C, a pressure of 1,500 psi, a static period of 5 min, a flush volume of 110%, two cycles and a purge time of 90 s. Determination of BTEX compounds is carried out by gas chromatography using a flame ionization detector. The recoveries, obtained for a confidence level of 95%, are 91 ± 4, 100 ± 3, 104 ± 2, 93 ± 4, 99 ± 2 and 99 ± 2% for benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene, respectively. The detection limits are 0.5 μg for benzene, 0.7 μg for toluene and 1.0 μg for the other compounds. The proposed procedure has been applied to real samples collected in several workplaces, like a microbiology laboratory, an analytical chemistry laboratory, a printer’s, a car repair shop and a petrol station. From the results obtained, it can be concluded that the occupational exposures determined are always acceptable because they are lower than the tenth part of the recommended exposure limits (VLA-ED and VLA-EC).  相似文献   

18.
Gas chromatography-mass spectrometry (GC/MS) was employed for the determination of 30 widely used pesticides including various transformation products and alkylphenols in water and agricultural soils with the aim of assessing the impact of these compounds in agricultural soils and the underlying aquifer. The extraction, clean-up, and analytical procedures were optimized for both water and soil samples to provide a highly robust method capable of determining target analytes at the ppb–ppt level with high precision. For water samples, different solid-phase extraction cartridges and conditions were optimized; similarly, pressurized liquid extraction conditions were tested to provide interference-free extracts and high sensitivity. Instrumental LODs of 3–4 pg were obtained. The multi-residue extraction procedures were applied to the analysis of groundwaters and agricultural soils from the Ebro river basin (NE Spain). Most ubiquitous herbicides detected were triazines but some acetanilides and organophosphorus pesticides were also found; the pesticide additive tributylphosphate was found in all water samples. Levels varied between 0.57 and 5.37 μg/L in groundwater, whereas nonylphenol was the sole compound detected in soil. Alkylphenols are used as adjuvants in pesticide formulations and are present in sludges employed as soil fertilizers. Occurrence was found to be similar to other environmental studies.  相似文献   

19.
Summary Extra-fine powdered activated charcoal has been used as stationary phase (coating layer) in solid-phase microextraction (SPME). The efficiency and reliability of the prepared device have been investigated for the extraction of some volatile organic compounds such as benzene, toluene, ethylbenzene and xylene isomers (BTEX) from the headspace of water samples. Monitoring of the extracted compounds and further quantitative analysis of the real samples have been performed by capillary GC-FID. Effects of several factors such as temperature, addition of salt, and stirring speed on extraction efficiency and exposure time have been studied. Under optimum conditions, extraction recoveries for these compounds from 50 mL water were >95%. The calibration graphs were linear in the range 5 to 104 pg mL−1 and the detection limit for each BTEX compound was 1.5–2 pg mL−1. The results obtained by use of this porous layer activated charcoal (PLAC)-coated fiber have also been compared with results reported in the literature by use of a polydimethylsiloxane (PDMS)-coated fiber. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

20.
A sensitive LC-MS/MS assay for quantification of total and free concentrations of R- and S-warfarin in plasma was required to support clinical studies on warfarin enantiomers. Several ultrafiltration devices were evaluated for separation of free warfarin from plasma proteins. The highest precision and lowest non-specific binding was obtained for Centrifree ultrafiltration devices. R- and S-warfarin were extracted from plasma (total) and ultrafiltrate (free) by liquid–liquid extraction with methyl tert-butyl ether using d6-warfarin as internal standard. Mean extraction recovery was 68 ± 4%. The enantiomers were separated on a Chirobiotic V column with isocratic elution using 40% methanol and 0.03% acetic acid in water. Negative mode electrospray ionisation was used for MS/MS detection, monitoring the ion transition m/z 307/161. Calibration curves (quadratic, weighted 1/x) were fitted over the range of 20–2,000 ng/ml (r 2 ≥ 0.995) in plasma and 0.5–20 ng/ml (r 2 ≥ 0.998) in ultrafiltrate. The lower limit of quantification for R- and S-warfarin was 0.5 ng/ml in ultrafiltrate. Intra- and interday precision (% RSD) and bias were within 10% in all cases, and matrix effects were negligible. The assay was applied successfully to analysis of samples from clinical studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号