首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A Pd/IrO(2) co-electrodeposited glassy carbon electrode was prepared and the electrochemical behavior of glutathione (GSH) at this chemically modified electrode (CME) has been studied by cyclic voltammetry (CV). The results indicated that the modified electrode efficiently exhibited electrocatalytic oxidation for GSH with relatively high sensitivity, stability, and long-life. Coupled with high-performance liquid chromatography (HPLC), the Pd/IrO(2) modified electrode was utilized for the electrochemical detection (ECD) of the thiocompounds, glutathione and cysteine (Cys). The peak currents were linear with the substance concentrations in the range of 1.0 x 10(-5) mol L(-1) to 8.0 x 10(-4) mol L(-1) for GSH and 4.0 x 10(-6) mol L(-1) to 2.0 x 10(-4) mol L(-1) for Cys. The detection limits were 2.0 x 10(-6) mol L(-1) for GSH and 5.0 x 10(-7) mol L(-1) for Cys with S/N of 3. The method has been successfully applied to assess the contents of GSH and Cys in rat brain microdialysates.  相似文献   

2.
王桂芬  朴元哲 《分析化学》1998,26(12):1490-1493
应用循环伏安法、微分脉冲伏安法对多菌灵在破碳电极上的电化学行为及其测定进行了研究。在pH=9.0的2mol/L NH3-NH4Cl底液中,对其进行循环伏安扫描,发现于0.61V(vs.Ag/AgCl)产生一灵敏的氧化峰。微分脉冲伏安法殉菌灵的检测限为4×10^-8mol/L。多菌灵的浓度在5.0×10^-7 ̄1.0×10^-5mol/L间与微分脉冲伏安峰电流呈线性关系(r=0.9942)。对于1×  相似文献   

3.
研究了金-钯双金属纳米颗粒修饰电极测定痕量砷的阳极溶出伏安法。采用紫外可见分光光度法、高分辨透射电镜及循环伏安法对颗粒的结构和电化学特性进行表征。采用方波伏安法测定三价砷,探讨了富集电位和方波伏安参数如频率、增幅、波幅以及干扰离子等对测定结果的影响。实验结果表明:金-钯双金属纳米颗粒呈壳-核结构;砷在0.30 V出现灵敏的阳极溶出伏安峰,峰电流与砷质量浓度在0.5~20μg/L范围内呈良好的线性关系,检出限为0.15μg/L;所制备的修饰电极重现性好,可用于三价砷的重复测定。共存离子Cu(Ⅱ)会影响三价砷的测定,而Pb(Ⅱ)、Cd(Ⅱ)、Zn(Ⅱ)等离子的存在对测定结果无影响。  相似文献   

4.
A simple and highly selective electrochemical method was developed for the simultaneous determination of aspartame and cyclamate in dietary products at a boron-doped diamond (BDD) electrode. In square-wave voltammetric (SWV) measurements, the BDD electrode was able to separate the oxidation peak potentials of aspartame and cyclamate present in binary mixtures by about 400 mV. The detection limit for aspartame in the presence of 3.0x10(-4) mol L(-1) cyclamate was 4.7x10(-7) mol L(-1), and the detection limit for cyclamate in the presence of 1.0x10(-4) mol L(-1) aspartame was 4.2x10(-6) mol L(-1). When simultaneously changing the concentration of both aspartame and cyclamate in a 0.5 mol L(-1) sulfuric acid solution, the corresponding detection limits were 3.5x10(-7) and 4.5x10(-6) mol L(-1), respectively. The relative standard deviation (R.S.D.) obtained was 1.3% for the 1.0x10(-4) mol L(-1) aspartame solution (n=5) and 1.1% for the 3.0x10(-3) mol L(-1) cyclamate solution. The proposed method was successfully applied in the determination of aspartame in several dietary products with results similar to those obtained using an HPLC method at 95% confidence level.  相似文献   

5.
制备了2,5-巯基-1,3,4-硫代二氮唑(DMTD)自组装单分子层修饰金电极,用电化学阻抗谱进行了表征,研究了Ag(I)在该电极上的电化学行为并用差分脉冲阳极溶出伏安法对其进行了测定。结果表明,DMTD/Au电极能显著提高Ag(I)测定的灵敏度和选择性,Ag(I)浓度在9.4×10-7~8.0×10-6mol/L范围内,氧化峰电流与Ag(I)呈现良好的线性关系,检出限为2×10-7 mol/L。该自组装电极可用于水样的测定。  相似文献   

6.
Myoglobin (Mb) has been successfully immobilized on a self-assembled monolayer (SAM) of L-cysteine (Cys) on a gold electrode, Au/Cys. The presence of a pair of well-defined and nearly reversible waves centered at ca. 0.086 V vs Ag/AgCl (pH 6.5) suggests that the native character of Mb heme Fe(III/II) redox couple has been obtained. The formal potential of Mb on Cys SAM exhibited pH-dependent variation in the pH range of 5-9 with a slope of 55 mV/pH, indicating that the electron transfer is accompanied by a single proton exchange. Thermodynamic and kinetic aspects of Mb adsorption processes on Au/Cys were studied by using voltammetric and quartz-crystal microbalance methods. The Au/Cys electrode with immobilized Mb exhibited electrocatalytic activity toward ascorbic acid (AA) oxidation with an overpotential decrease of over 400 mV and a linear dependence of current on the AA concentration from 0.5 to 5.0 mmol L(-1).  相似文献   

7.
The penicillamine (Pen) self-assembled monolayer (SAM) modified gold electrode (Pen/Au) is demonstrated to catalyze the electrochemical response of dopamine (DA) by cyclic voltammetry. A pair of well-defined redox waves was obtained and the calculated standard rate constant (k(s)) is 3.88 x 10(-3) cm/s at the self-assembled electrode. The electrode reaction is a quasi-reversible process. The oxidation peak of DA can be used to determine the concentration of DA. The peak current and the concentration of DA are a linear relationship in the range of 2.0 x 10(-5) M to 8.0 x 10(-4) M. The detection limit is 4.0 x 10(-6) M. By ac impedance spectroscopy the apparent electron transfer rate constant (k(app)) of Fe(CN)(3-)/Fe(CN)(4-) at the Pen/Au electrode was obtained as 2.08 x 10(-5) cm/s. The Pen SAM was characterized with X-ray photoelectron spectroscopy (XPS), grazing angle FT-IR spectroscopy and contact angle goniometer.  相似文献   

8.
A new strategy for the preparation of a DNA-modified carbon paste electrode is developed. It is found that the anodic response of mifepristone is greatly enhanced at the dsDNA-modified carbon paste electrode comparing with that obtained at the bare electrode, while the response at a ssDNA-modified electrode is similar to bare electrode. So the dsDNA-modified electrode is employed as a sensitive biosensor for the detection of mifepristone. A linear dependence of the peak currents on the concentration is observed in the range 2.0 x 10(-7) approximately 2.0 x 10(6) mol/L, with a detection limit of 1.0 x 10(-7) mol/L. The relative standard deviation is 4.3% for six successive determinations of 1.0 x 10(6) mol/L mifepristone. The determination of mifepristone tablets is carried out and satisfactory results are obtained.  相似文献   

9.
A simple flow injection system is proposed for the determination of thiamine in pharmaceutical formulations. The determination is based on the precipitation reaction of thiamine with silicotungstic acid in acidic medium to form a thiamine silicotungstate suspension that is measured at 420 nm. Adding 0.05% (w/v) poly(ethyleneglycol) in the carrier solution (0.5 mol l(-1) hydrochloric acid), an improvement in the sensitivity, repeatability and baseline stability of the flow injection system was obtained. The calibration graph was linear in the thiamine concentration range from 5.0x10(-5) to 3.0x10(-4) mol l(-1) with a detection limit of 1.0x10(-5) mol l(-1). The relative standard deviations for ten successive measurements of 1.0x10(-4) mol l(-1) and 2.5x10(-4) mol l(-1) thiamine were less than 1% and an analytical frequency of 90 h(-1) was obtained.  相似文献   

10.
The weak fluorescence of N-[P-(2-benzoxazolyl)phenyl]maleimide (BOPM) can be greatly enhanced by thiol-containing compounds. A sensitive and simple spectrofluorimetric method based on the use of BOPM has been developed for the determination of thiols such as cysteine (Cys) and reduced glutathione (GSH). Calibration plots were linear in the concentration range from 0 to 1.6 x 10(-7) mol L(-1) for Cys and 0 to 1.7 x 10(-7) mol L(-1) for GSH. The detection limits (3a) were 2.36 x 10(-10) mol L(-1) for Cys and 1.49 x 10(-10) mol L(-1) for GSH. Many other amino acids (present at 100-fold greater concentrations) did not interfere with the determination. The proposed method has been used for the determination of Cys in protein hydrolysate and cystine electrolyte or GSH in serum, with recoveries of 95.4-103.7%.  相似文献   

11.
《Analytical letters》2012,45(4):697-707
Abstract

The preparation of a gold electrode modified by aminylferrocene (FcAI) covalently bound to L‐cysteine self‐assembled monolayer (L‐Cys/Au SAM) was described, and characterized by cyclic voltammogram (CV) and electrochemical impedance spectroscopy (EIS). In pH 7.4 buffers, FcAI incorporated in L‐Cys/Au SAM gave a pair of well‐defined and quasi‐reversible cyclic voltammetric peaks at 0.109 vs. saturated calomel eletrode (SCE), characteristic of Fe(II)/Fe(III) redox couples of the Fc. The apparent surface electron transfer rate constant is 6.86 s?1 at the modified electrode. The immobilized Fc gave an excellent electrocatalytic activity for the oxidation of epinephrine (EP). The catalytic current of EP vs. its concentration has a good linear relation in the range of 1.7×10?7–1.0×10?4 mol/L, with the correlation coefficient of 0.9975 and detection limit of 1.8×10?8 mol/L. The modified electrode can be used for the determination of EP in practical injection. The method is simple, quick, sensitive, and accurate.  相似文献   

12.
2,5-Dimercapto-1,3,4-thiadiazol (DMTD) can bind on the surface of a gold electrode through the strong gold-sulfur interaction. The fabrication and electrochemical characteristics of the DMTD self-assembled monolayer (SAM)-modified gold electrode were investigated. The DMTD SAM electrode exhibited a significantly increased sensitivity. Cu(II) was accumulated in phosphate buffer (pH 4.6) at a potential of -0.6 V (vs. Ag/AgCl) for 40 s and then determined by anodic stripping voltammetry (ASV) in copper-free phosphate buffer (pH 5.0). The effects of various parameters, such as the pH values of the preconcentration solution and measurement solution, the accumulation potential, and the accumulation time, were investigated. Under the optimum conditions, a linear calibration graph was obtained in the concentration range of 8.0 x 10(-6) to 8.0 x 10(-5) mol l(-1) with a correlation coefficient of 0.9978. The relative standard deviations for eight successive determinations were 4.3 and 2.9% for 1.0 x 10(-5) and 2.0 x 10(-5) mol l(-1) Cu(II), respectively. The detection limit (three times signal to noise) was 4.0 x 10(-7) mol l(-1). The proposed voltammetric method was utilized successfully to detect the concentration of Cu(II) ions in tap water samples.  相似文献   

13.
张亚  郑建斌 《应用化学》2016,33(1):103-107
制备了石墨烯修饰玻碳电极(GN/GCE)。 在0.5 mol/L HAc-NaAc(pH=4.8)缓冲溶液中,用循环伏安法(CV)和方波伏安法(SWV)研究了米吐尔在修饰电极上的电化学行为,建立了测定米吐尔的新方法。 研究表明,米吐尔在GN/GCE上的氧化、还原峰电势差比其在裸玻碳电极(GCE)上的小,峰电流显著增加,说明GN/GCE对米吐尔有电催化作用;共存物对苯二酚干扰米吐尔的测定,通过方波伏安法可以消除其干扰。 在方波伏安曲线上,米吐尔的还原峰电流与其浓度在8.0×10-8~5.0×10-5 mol/L范围内呈线性关系,检出限为2.0×10-8 mol/L。 该法可用于照相显影废液中米吐尔的测定。  相似文献   

14.
The comparative electrochemical behavior of self-assembled monolayers of two Schiff's bases, 2-{[(Z)-1-(3-furyl)methylidene]amino}-1-benzenethiol (FMAB) and 2-{[(2-sulfanylphenyl)imino]methyl}phenol (SIMP) on a bare gold electrode (Au FMAB SAM-modified electrode and Au SIMP SAM-modified electrode, respectively), was investigated by means of cyclic voltammetry and electrochemical impedance spectroscopy in a 0.1 mol L(-1) KCl solution that contains 5.0 × 10(-3) mol L(-1) [Fe(CN)(6)](3-/4-). The results revealed that the modified electrodes showed an electrocatalytic activity toward the anodic oxidation of dopamine by a marked enhancement in the current response and lower overpotential (60 and 90 mV for the Au FMAB and Au SIMP SAM-modified electrodes, respectively) in phosphate buffer solution at pH 6.0. The Au SIMP SAM-modified electrode was applied successfully to the determination of dopamine in the presence of a high concentration of ascorbic acid. Selective detection was realized in total elimination of ascorbic acid response-a method different from the ones based on the potential separations. The detection limit of dopamine was 5.0 × 10(-8) mol L(-1) in a linear range from 1.0 × 10(-6) to 1.2 × 10(-4) mol L(-1) in the presence of 1.0 × 10(-3) mol L(-1) ascorbic acid. The interference studies also showed that the Au SIMP SAM-modified electrode exhibited good selectivity in the presence of a large excess of uric acid and could be employed for the determination of dopamine in pharmaceutical formulations, plasma samples and human urine with adequate selectivity and precision.  相似文献   

15.
Fluorimetric determination of peroxynitrite based on an enzymatic reaction.   总被引:1,自引:0,他引:1  
A novel fluorimetric method for the determination of peroxynitrite (ONOO-) using hemoglobin (Hb) as a catalyst is described. The method employs the reaction of ONOO with thiamine (TM), a colorless, non-fluorescent reagent in a glycine-NaCl-NaOH buffer solution (pH 12.7), to generate a highly fluorescent product, thiochrome (TC). The fluorescent product was monitored by fluorimetry. A linear calibration graph was obtained over an ONOO- concentration range from 4.95 x 10(-7) mol L(-1) to 2.97 x 10(-5) mol L(-1), with a detection limit of 9.78 x 10(-9) mol L(-1) ONOO-. The relative standard deviation at an ONOO- concentration of 2.11 x 10(-6) mol L(-1) was 4.15% (n = 9).  相似文献   

16.
Wang C  Wang G  Jiao S  Guo Z  Fang B 《Annali di chimica》2007,97(5-6):331-342
Aminylferrocene(FcAI)-Nanogold(NG) modified glassy carbon electrode (FcAI/NG/GCE) was prepared by the Au-N bond between Au and FcAI. Electrochemical impedance spectroscopy (EIS) was employed to study the surface of the modified electrode. The electrochemical behavior of dopamine (DA) on the modified electrode was investigated and it was found that the modified electrode had an obvious electrocatalytic effect on DA. Compared with a bare GCE, the modified electrode exhibited an apparent shift of the oxidation peak potential in the negative potential direction and a marked enhancement in the current response for DA. We investigated the determination of DA on the modified electrode by differential pulse voltammetry (DPV). Linear calibration curve was obtained in the range of 7.0 x 10(-7) mol/L to 6x10(-4) mol/L of DA in 0.1 mol/L phosphate buffer solution (pH = 7.0) with a correlation coefficient of 0.9989. The detection limit (S/N = 3) of DA was estimated to be 1.0 x 10(-7) mol/L. Especially, by using the modified electrode, we can separate the oxidation peaks of ascorbic acid (AA) and DA in the PBS and it was satisfactory for the determination of DA with the interference of AA.  相似文献   

17.
Sorption of gold(III) chlorocomplexes was studied by means of a carbon paste electrode modified with montmorillonite. Anionic exchange behavior was found in chloride media with low ionic strength. Anionic sorption of [AuCl4]- can be used as a preconcentration step to the determination of Au(III). Linear calibration dependences were found in the concentration range 4.06 x 10(-6) - 1.22 x 10(-5) mol/L Au(III) after 5 min of sorption and in the range 8.12 x 10(-7) - 6. 1 x 10(-6) mol/L after 10 min of sorption. Interferences of several anions and cations were studied. Model samples of table water were analyzed.  相似文献   

18.
邓培红 《应用化学》2009,26(7):875-877
以多壁碳纳米管修饰乙炔炭黑微电极为工作电极,研究了碘离子在该修饰电极上的阳极溶出伏安特性。在0.1 mol/L KH2PO4 缓冲液(pH4.0)中,从200 mV以200 mV/s的速率正向扫描至1200 mV,碘离子在570 mV处出现一灵敏的阳极溶出峰。峰电流与碘离子的浓度在2.0×10-6~1.0×10-3 mol/L范围内呈良好的线性关系,检出限为8.0×10-7 mol/L。方法用于食盐中碘含量的测定,结果满意。  相似文献   

19.
制备了一种新型的Nafion/Au溶胶修饰微铂传感器(Au溶胶颗粒的直径为7~14nm),并将该传感器应用于心肌细胞中NO水平的研究.实验结果表明,自组装制备的Nafion/Au溶胶修饰微传感器对NO有较高的灵敏度和良好的选择性,在1.0×10-7~4.0×10-5mol/L浓度范围内,NO的催化氧化电流与其浓度呈良好线性关系,检测限为5.0×10-8mol/L.探讨了该修饰微传感器对NO的催化机理,研究了在L-精氨酸和乙酰胆碱刺激下心肌细胞内的NO释放.  相似文献   

20.
Lu X  Wang Z  Geng Z  Kang J  Gao J 《Talanta》2000,52(3):411-416
A differential pulse anodic stripping voltammetry was developed for the sensitive and selective determination of Co(II) at 2,4,6-tri(3,5-dimethylpyrazoyl)-1,3,5-triazine modified carbon paste electrode in 0.1 mol l(-1) NH(4)Cl solution (pH 4.95). The oxidation peak of Co(II) was observed at 0.03 V(vs. Ag/AgCl) by scanning the potential in a positive direction. The analysis procedure consisted of an open circuit accumulation step in stirred sample solution. This was followed by medium exchange to a clean solution and subsequently an anodic potential scan was effect to obtain the voltammetric peak. The current was proportional to the concentration of the Co(II) ion in a range of 1x10(-8)-1x10(-6) mol l(-1) for 3 min accumulation and in the range of 1x10(-9)-1x10(-8) mol l(-1) for 5 min accumulation; most of metal ions do not interfere with the determination. The developed method was applied to Co(II) determination in potable water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏