首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Okanda FM  El Rassi Z 《Electrophoresis》2005,26(10):1988-1995
A neutral, nonpolar monolithic capillary column having a relatively strong electroosmotic flow (EOF) yet free of electrostatic interactions with charged solutes was developed for the reversed-phase capillary electrochromatography (RP-CEC) of neutral and charged species including peptides and proteins. The neutral nonpolar monolith is based on the in situ polymerization of pentaerythritol diacrylate monostearate (PEDAS) in a ternary porogenic solvent composed of cyclohexanol, ethylene glycol, and water. PEDAS plays the role of both the cross-linker and the ligand provider, generating a macroporous nonpolar monolith having C17 chains as the chromatographic ligands. Despite the fact that the neutral PEDAS monolith is devoid of fixed charges, the monolithic capillary columns exhibited a relatively strong EOF due to the ability of PEDAS to adsorb sufficient amounts of electrolyte ions from the mobile phase. The adsorbed ions imparted the neutral PEDAS monolith the zeta potential necessary to support the EOF required for mass transport across the monolithic column. The absence of fixed charges on the surface of the neutral PEDAS monolith and in turn the adsorption sites for electrostatic attraction of charged solutes allowed the rapid and efficient separations of proteins and peptides at pH 7.0, with an average plate number of 255,000 and 121,000 plates/m, respectively. To the best of our knowledge, this constitutes the first report on the separation of proteins at neutral pH by RP-CEC using a neutral monolithic column.  相似文献   

2.
A neutral, nonpolar monolithic capillary column was evaluated as a hydrophobic stationary phase in pressurized CEC system for neutral, acidic and basic solutes. The monolith was prepared by in situ copolymerization of octadecyl methacrylate and ethylene dimethacrylate in a binary porogenic solvent consisting of cyclohexanol/1,4‐butanediol. EOF in this hydrophobic monolithic column was poor; even the pH value of the mobile phase was high. Because of the absence of fixed charges, the monolithic capillary column was free of electrostatic interactions with charged solutes. Separations of neutral solutes were based on the hydrophobic mechanism with the pressure as the driving force. The acidic and basic solutes were separated under pressurized CEC mode with the pressure and electrophoretic mobility as the driving force. The separation selectivity of charged solutes were based on their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase, and no obvious peak tailing for basic analytes was observed. Effects of the mobile phase compositions on the retention of acidic compounds were also investigated. Under optimized conditions, high plate counts reaching 82 000 plates/m for neutral compounds, 134 000 plates/m for acid compounds and 150 000 plates/m for basic compounds were readily obtained.  相似文献   

3.
Lü H  Wang J  Wang X  Wu X  Lin X  Xie Z 《Journal of separation science》2007,30(17):2993-2999
A monolithic stationary phase was prepared in a single step by in situ copolymerization of iso-butyl methacrylate (IBMA), ethylene dimethacrylate (EDMA), and N,N-dimethylallylamine (DMAA) in a binary porogenic solvent consisting of N,N-dimethylformamide (DMF) and 1,4-butanediol. As the frame structures of monoliths, the amino groups are linked to support the EOF necessary for driving the mobile phase through the monolithic capillary, while the hydrophobic groups are introduced to provide the nonpolar sites for the chromatographic retention. To evaluate the column performance, separations of typical kinds of neutral or charged homologs, such as alkylbenzenes, phenols (including isomeric compounds of hydroquinone, resorcin, and catechol), and anilines (including isomeric compounds of o-phenylenediamine and 1,4-phenylenediamine), were performed, respectively on the prepared column under the mode of pressurized pCEC. Effects of the buffer pH and the mobile phase composition on the linear velocity of mobile phase and the retention factors of these compounds were investigated. It was found that the retention mechanism of charged solutes could be attributed to a mixed mode of hydrophobic interaction and electrophoresis, while an RP chromatographic behavior on the monolithic stationary phases was exhibited for neutral solutes. Especially, basic compounds such as anilines were well separated on the monolithic columns in the "counterdirectional mode," which effectively eliminated the electrostatic adsorption of basic analytes on the charged surface of the stationary phases.  相似文献   

4.
In this paper, a novel highly cross‐linked porous monolithic stationary phase having a long alkyl chain ligand (C16) was introduced and evaluated in CEC. The monolithic stationary phase was prepared by in situ copolymerization of 1‐hexadecene, trimethylolpropane trimethacrylate, and 2‐acrylamido‐2‐methyl‐1‐propanesulfonic acid (AMPS) in the presence of ternary porogenic solvent (cyclohexanol/1,4‐butanediol/water). In preparing monoliths, the ternary cross‐linker trimethylolpropane trimethacrylate was usually applied to preparing molecularly imprinted polymers or molecularly imprinted solid‐phase extraction, instead of binary cross‐linker ethylene dimethacrylate. 1‐Hexadecene was introduced to provide the non‐polar sites (C16) for chromatographic retention, while AMPS was used to generate the EOF for transporting the mobile phase through the monolithic capillary. Monolithic columns were prepared by optimizing proportion of porogenic solvent and AMPS content in the polymerization solution as well as the cross‐linkers. The monolithic stationary phases could generate a strong and stable EOF in various pH values and exhibit an RP‐chromatographic behavior for neutral compounds. For charged compounds, the separation was mainly based on the association of hydrophobic, electrostatic and electrophoretic interaction.  相似文献   

5.
A polar and neutral polymethacrylate-based monolithic column was evaluated as a hydrophilic interaction capillary electrochromatography (HI-CEC) stationary phase with small polar–neutral or charged solutes. The polar sites on the surface of the monolithic solid phase responsible for hydrophilic interactions were provided from the hydroxy and ester groups on the surface of the monolithic stationary phase. These polar functionalities also attract ions from the mobile phase and impart the monolithic solid phase with a given zeta potential to generate electro-osmotic flow (EOF). The monolith was prepared by in situ copolymerization of a neutral monomer 2-hydroxyethyl methacrylate (HEMA) and a polar cross-linker with hydroxy group, pentaerythritol triacrylate (PETA), in the presence of a binary porogenic solvent consisting cyclohexanol and dodecanol. A typical HI-CEC mechanism was observed on the neutral polar stationary phase for both neutral and charged analytes. The composition of the polymerization mixture was systematically altered and optimized by altering the amount of HEMA in the polymerization solution as well as the composition of the porogenic solvent. The monoliths were tested in the pCEC mode. The resulting monoliths had different characteristics of hydrophilicity, column permeability, and efficiency. The effects of pH, salt concentration, and organic solvent content on the EOF velocity and the separation of nucleic acids and nucleosides on the optimized monolithic column were investigated. The optimized monolithic column resulted in good separation and with greater than 140,000 theoretical plates/m for pCEC.  相似文献   

6.
A novel silica monolithic stationary phase functionalized with 3-(2-aminoethylamino)propyl ligands for pressurized CEC has been presented. The monolithic capillary columns were prepared by a sol-gel process in 75 microm id fused-silica capillaries and followed by a chemical modification. The diamino groups on the surface of the stationary phase are meant to generate the chromatographic surface and a substantial anodic EOF as well as to provide electrostatic interaction sites for charged solutes. The electrochromatographic characterization and column performance were evaluated by a variety of neutral and charged solutes. It was observed that the anodic EOF for the diamine-bonded monolith was greatly affected by the reaction time with 3-(2-aminoethylamino)propyltrimethoxysilane and the PEG amount in the sol-gel reaction mixture in addition to the mobile phase conditions. The monolithic stationary phase exhibited hydrophilic interaction chromatographic behavior toward neutral solutes. Good separations of various solutes including phenols, nucleic acid bases, nucleosides and nucleotides were achieved under different experimental conditions. Fast and efficient separations were obtained with high plate counts reaching more than 130,000 plates/m.  相似文献   

7.
A neutral octadecyl monolithic (ODM) column for RP capillary electrochromatography (RP-CEC) has been developed. The ODM column was prepared by the in situ polymerization of octadecyl acrylate (ODA) as the monomer and trimethylolpropanetrimethacrylate (TRIM) as the crosslinker, in a ternary porogenic solvent containing cyclohexanol, ethylene glycol, and water. The ODM column exhibited cathodal EOF over a wide range of pH and ACN concentration in the mobile phase despite the fact that it was devoid of any fixed charges. It is believed that the EOF is due to the adsorption of ions from the mobile phase onto the surface of the monolith thus imparting to the neutral ODM column the zeta potential necessary to support the EOF required for mass transport across the monolithic column. Furthermore, the adsorption of mobile phase ions to the neutral monolith modulated solute retention and affected the separation selectivity. The wide applications of the neutral ODM column were demonstrated by its ability to separate a wide range of small and large solutes, both neutral and charged. While the separation of the neutral solutes was based on RP retention mechanism, the charged solutes were separated on the basis of their electrophoretic mobility and hydrophobic interaction with the C18 ligands of the stationary phase. As a typical result, the neutral monolithic column was able to separate peptides quite rapidly with a separation efficiency of nearly 200,000 plates/m, and this efficiency was exploited in tryptic peptide mapping of standard proteins, e. g., lysozyme and cytochrome C, by isocratic elution.  相似文献   

8.
Lin J  Huang G  Lin X  Xie Z 《Electrophoresis》2008,29(19):4055-4065
A novel porous polymethacrylate-based monolithic column by in situ copolymerization of 3-sulfopropyl methacrylate (SPMA) and pentaerythritol triacrylate in a binary porogenic solvent consisting of cyclohexanol/ethylene glycol was prepared. The monolith possessed in their structures bonded sulfonate groups and hydroxyl groups and was evaluated as a hydrophilic interaction and strong cation-exchange stationary phases in capillary liquid chromatography (cLC) and pressure-assisted CEC using small polar neutral and charged solutes. While the SPMA was introduced as multifunctional monomer, the pentaerythritol triacrylate was used to replace ethylene glycol dimethacrylate as cross-linker with much more hydrophilicity due to a hydroxyl sub-layer. The different characterization of monolithic stationary phases were specially designed and easily prepared by altering the amount of SPMA in the polymerization solution as well as the composition of the porogenic solvent for cLC and pressure-assisted CEC. The resulting monolith showed the different trends about the effect of the permeabilities on efficiency in the pressure-assisted CEC and cLC modes. A typical hydrophilic interaction chromatography mechanism was observed at higher organic solvent content (ACN%>70%) for polar neutral analytes. For polar charged analytes, both hydrophilic interaction and electrostatic interaction contributed to their retention. Therefore, for charged analytes, selectivity can be readily manipulated by changing the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). With the optimized monolithic column, high plate counts reaching greater than 170 000 plates/m for pressure-assisted CEC and 105 000 plates/m for cLC were easily obtained, respectively.  相似文献   

9.
Wu R  Zou H  Ye M  Lei Z  Ni J 《Electrophoresis》2001,22(3):544-551
A mode of capillary electrochromatography (CEC), based on the dynamical adsorption of surfactants on the uncharged monolithic stationary phases has been developed. The monolithic stationary phase, obtained by the in situ polymerization of butyl methacrylate with ethylene dimethacrylate, was dynamically modified with an ionic surfactant such as the long-chain quaternary ammonium salt of cetyltrimethylammonium bromide (CTAB) and long-chain sodium sulfate of sodium dodecyl sulfate (SDS). The ionic surfactant was adsorbed on the surface of polymeric monolith by hydrophobic interaction, and the ionic groups used to generate the electroosmotic flow (EOF). The electroosmotic mobility through these capillary columns increased with increasing the content of ionic surfactants in the mobile phase. In this way, the synthesis of the monolithic stationary phase with binary monomers can be controlled more easily than that with ternary monomers, one of which should be an ionic monomer to generate EOF. Furthermore, it is more convenient to change the direction and magnitude of EOF by changing the concentration of cationic or anionic surfactants in this system. An efficiency of monolithic capillary columns with more than 140000 plates per meter for neutral compounds has been obtained, and the relative standard deviations observed for to and retention factors of neutral solutes were about 0.22% and less than 0.56% for ten consecutive runs, respectively. Effects of mobile phase composition on the EOF of the column and the retention values of the neutral solutes were investigated. Simultaneous separation of basic, neutral and acidic compounds has been achieved.  相似文献   

10.
Dong J  Ou J  Dong X  Wu R  Ye M  Zou H 《Journal of separation science》2007,30(17):2986-2992
A CEC monolithic column with strong cation-exchange (SCX) stationary phase based on hydrophilic monomers was prepared by in situ polymerization of acrylamide, methylenebisacrylamide, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a complete organic binary porogenic solvent consisting of DMSO and dodecanol. The sulfonic groups provided by the monomer AMPS on the surface of the stationary phase generate an EOF from anode to cathode, and serve as an SCX stationary phase at the same time. The monolithic stationary phase exhibited normal-phase chromatographic behavior for neutral analytes. For charged analytes, electrostatic interaction/repulsion with the monolith was observed. The strong SCX monolithic column has been successfully employed in the electrochromatographic separation of basic drugs, peptides, and alkaloids extracted from natural products.  相似文献   

11.
A novel cationic monolithic stationary phase based on the co-polymerization of pentaerythritol diacrylate monostearate (PEDAS) with a selected quaternary amine acrylic monomer was designed for performing capillary electrochromatography at high flow velocity. While PEDAS functioned as both the ligand provider and the cross-linker, the quaternary amine acrylic monomer was introduced to control the magnitude of the electroosmotic flow (EOF). The fabrication of the cationic stearyl-acrylate monolith (designated as cationic C17 monolith) with controlled porosity was achieved by free radical polymerization using the initiator 2,2'-azobisisobutyronitrile in the presence of a ternary porogenic solvent composed of cyclohexanol, ethylene glycol and water. Four different quaternary amine acrylic monomers were investigated in order to find the optimum monomer for achieving maximum electroosmotic flow (EOF) velocity. Both photo- and thermally-initiated polymerization proved effective in producing the cationic C17 monolith, and the best monolith was achieved when [2-(acryloyloxy)ethyl]trimethyl ammonium methyl sulfate (AETA) was used as the quaternary amine acrylic monomer. Although the zeta potential of the resulting cationic C17 monolith is positive with respect to water, the magnitude and direction of the EOF was markedly affected by the nature of the electrolyte in the mobile phase. Consequently, anodal, zero or cathodal EOF was observed depending on the nature of the electrolyte, and this was attributed to the adsorption of the ionic components of the electrolyte on to the solid stationary phase, which is characterized by its amphiphilic nature consisting of C17 chains, ester functions, hydroxyl groups and quaternary amine moieties. Optimized PEDAS-AETA monoliths yielded columns with high separation efficiency and allowed rapid separations on the time scale of seconds to be achieved with short capillaries.  相似文献   

12.
Organic monolithic stationary phases have been synthesized in UV-transparent fused-silica capillaries, which have been used as test format of microfabricated device channels. The columns have been prepared by in situ polymerization of butyl acrylate, lauryl acrylate, 1,3-butanediol diacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent. The resulting stationary phases have been tested in capillary electrochromatography and exhibited reversed-phase chromatography behavior toward neutral solutes. Van Deemter plots of phenylureas and polycyclic aromatic hydrocarbons, selected as model analytes, have been determined to study the influence of various polymerization and separation parameters on properties of the monoliths. The amount of AMPS and the nature of monomers in the polymerization solution have been thus adjusted. It has been observed that the ionic strength of the mobile phase may affect significantly the efficiency of the separation. The effect of the percentage of acetonitrile in the mobile phase on efficiency and permeability of the organic monoliths has also been investigated. Efficiencies greater than 300,000 plates/m have been obtained with the test compounds. Stability and reproducibility have been extensively studied.  相似文献   

13.
A linear polymer-coated capillary was prepared by in-capillary copolymerization of N-tert-butylacrylamide (TBAAm) with a charged monomer, 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS), after the capillary pretreatment with a bifunctional reagent. The coated capillaries were applied in capillary electrochromatographic (CEC) separation of small neutral compounds. Hydrophobic groups in the linear polymer, which were immobilized onto the capillary surface, functioned as the stationary phase in reversed-phase CEC separation, and charged groups in the linear polymer generated electroosmotic flow (EOF) along the column. The coated capillaries were prepared by a simple procedure. Moreover, the reproducibility with respect to EOF rate and migration times of the solutes was excellent. The results for CEC separation of small molecules using the linear polymer-coated capillaries are presented.  相似文献   

14.
In this study, eight benzophenones, which are commonly used as UV filters in various cosmetics and plastics, were analyzed by capillary electrochromatography with a methacrylate ester-based monolithic column. The effects of the composition and pH of mobile phase, porogenic solvent ratio, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) content on benzophenone separations were examined. For all benzophenones, separation performances were markedly improved in monolithic columns with larger 1-propanol ratio and higher AMPS content. Furthermore, a twofold increase in AMPS content almost reduced the separation time in half when a monolithic column had an adequately high surface area, i.e. monolithic column was produced in a higher ratio of 1-propanol. As well, the retention behaviors of these analytes in the monolithic column were strongly influenced by the level of acetonitrile in the mobile phase, and the pH of the mobile phase also had an apparent influence on separation resolution.  相似文献   

15.
 采用二元致孔剂原位聚合的方法制备了一种新型微电渗流毛细管原位柱。与三元致孔剂制柱方法相比 ,具有制备过程简单、重复性好、能够方便地通过改变致孔剂配比来改变柱床的孔径和孔结构的特点。得到的毛细管柱内部结构均匀 ,通透性好。通过对改变不同致孔剂配比所制备的原位柱的孔结构特征及电渗流情况考察 ,及对柱长和柱径与电渗流的关系的探讨 ,发现制备的原位柱在较高 pH值和较高的有机改性剂浓度条件下 ,电渗流均能保持在较低值 ,可以适应不同电泳分离模式的需要。  相似文献   

16.
Ye F  Xie Z  Wu X  Lin X  Chen G 《Journal of chromatography. A》2006,1117(2):170-175
A novel stationary phase phenylaminopropyl silica (PhA-silica) monolith was successfully prepared for pressure assisted capillary electrochromatography (pCEC). The monolithic silica matrix from a sol-gel process was chemically modified by using [3-(phenylamino)propyl]trimethoxysilane as surface modification reagent to produce the phenylaminoporpyl function. The secondary amino groups on the surface of the monolithic stationary phase contributed to the generation of anodic electroosmotic flow (EOF) under acidic conditions. The phenyl group together with the spacer (-(CH(2))(3)-) in PhA-silica provides sufficient hydrophobic properties. To evaluate the column performance, effects of buffer pH and mobile phase composition on the mobile phase linear velocity and the retention factors of alkylbenzenes, phenols and anilines were investigated in pCEC mode. The monolithic stationary phases exhibit typical reversed-phase (RP) electrochromatographic behavior toward neutral solutes. Hydrophobic as well as electrophoretic migration process within the monoliths was observed for the separation of basic solutes such as anilines without peak tailing.  相似文献   

17.
A silica-based monolithic stationary phase with mixed-mode of reversed phase (RP) and weak anion-exchange (WAX) for capillary electrochromatography (CEC) has been prepared. The mixed-mode monolithic silica column was prepared using the sol–gel technique and followed by a post-modification with hexadecyltrimethoxysilane (HDTMS) and aminopropyltrimethoxysilane (APTMS). The amino groups on the surface of the stationary phase were used to generate a substantial anodic EOF as well as to provide electrostatic interaction sites for charged compounds at low pH. A cathodic EOF was observed at pH above 7.3 due to the full ionization of residual silanol groups and the suppression in the ionization of amino groups. A variety of analytes were used to evaluate the electrochromatographic characterization and column performance. The monolithic stationary phase exhibited RP chromatographic behavior toward neutral solutes. The model anionic solutes were separated by the mixed-mode mechanism, which comprised RP interaction, WAX, and electrophoresis. Symmetrical peaks can be obtained for basic solutes because positively charged amino groups can effectively minimize the adsorption of positively charged analytes to the stationary phase.  相似文献   

18.
A novel polymethacrylate‐based monolithic column with covalently bonded zwitterionic functional groups was prepared by in situ copolymerization of N,N‐dimethyl‐N‐methacryloxyethyl N‐(3‐sulfopropyl) ammonium betaine (SPE), pentaerythritol triacrylate (PETA), and vinylsulfonic acid (VS) in a binary porogenic solvent consisting of cyclohexanol and ethylene glycol. This monolith was developed as a separation column for CEC. While SPE functioned as both an electrostatic interaction stationary phase and the polar ligand provider, VS was employed to generate EOF. PETA, which has much more hydrophilicity due to a hydroxyl sub‐layer, was used to replace ethylene dimethacrylate as a cross‐linker. The monolith provided an adequate EOF when VS level was maintained at 0.6% w/w. Different monolithic stationary phases were easily prepared by adjusting the ratio of PETA/SPE in the polymerization solution as well as the composition of the porogenic solvent. The observed RSD were ≤3.6, ≤4.3 and ≤5.6% for the EOF velocity, retention time, and column efficiency, respectively. The column efficiencies greater than 145 000 theoretical plates/m for thiourea and 132 000 theoretical plates/m for charged cytidine were obtained. The poly(SPE‐co‐PETA‐co‐VS) monolith showed good selectivity for neutral and charged polar analytes. It was found that the separation mechanism of charged polar solutes was attributed to a mixed mode of hydrophilic interaction and electrostatic interaction, as well as electrophoresis. No peak tailing was observed for the separation of basic compounds, such as basic nucleic acid bases and nucleoside on the monolith.  相似文献   

19.
Ding G  Da Z  Yuan R  Bao JJ 《Electrophoresis》2006,27(17):3363-3372
A silica-based CEC monolithic column with mixed modes of RP and weak anion-exchange (WAX) was successfully prepared by using the sol-gel technique at mild temperature. The synthesizing procedure was optimized by changing the ratios of tetraethoxysilane (TEOS), aminopropyltriethoxysilane (APTES), and octyltriethoxysilane (C(8)-TEOS) in the mixture. While serving as WAX group, the amino group dominated the charge on the surface of the capillary column and generated an EOF from cathode to anode at low pH. At pH above 7.5, a cathodic EOF was observed due to the full ionization of silanol group and the suppression in the ionization of amino group. The morphology of monolithic columns was examined by SEM, and the performance of column was evaluated in detail by separating different kinds of compounds. As expected, the monolithic column exhibited RP chromatographic behavior for neutral solutes. Fast and efficient separation of six aromatic acids was obtained using acidic mobile phase with column efficiency up to 160,000 plates/m. Symmetrical peaks can be obtained for aromatic amines because positively charged amino groups on the surface can effectively minimize the adsorption of positively charged analytes to the stationary phase.  相似文献   

20.
Monolithic columns have been prepared with a novel bonded silica stationary phase, tetradecylamine bonded silica (TDAS), and used in pressurized capillary electrochromatography (pCEC). The monolithic silica column matrix was prepared by a sol-gel process and then chemically modified with the spacer (3-glycidoxypropyl)trimethoxysilane and tetradecylamine. The introduced embedded polar amine groups dominated the charge on the surface of the monolithic stationary phase and generated an EOF from cathode to anode under acidic conditions. The tetradecyl hydrophobic chains in TDAS provide chromatographic interactions. The chromatographic characteristics of the prepared monolithic column were studied. Some aromatic compounds including alkylbenzenes, aromatic hydrocarbons, phenols, and anilines were successfully separated on the TDAS monolithic column in pCEC mode. As expected, the TDAS monolithic stationary phases exhibit typical reversed-phase electrochromatographic behavior toward neutral solutes due to the introduced tetradecyl groups. Hydrophobic as well as electrophoretic migration processes within the monoliths were observed in the separation of basic anilines. Symmetrical peaks can be obtained for anilines because the embedded polar amine groups on the surface can effectively shield the adsorption of positively charged analytes onto the stationary phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号