建立了气相色谱法测定工业废气中的氯化氰含量的方法。采用PE GC580型气相色谱仪,电子俘获检测器,Rt–PlotQ色谱柱,采用外标法定量。氯化氰浓度在0.1~10 mol/mol范围内与峰面积呈良好的线性关系,相关系数大于0.999,9次重复测定结果的相对标准偏差小于4%,样品加标回收率为95%~104%。结果表明该方法简单、快速,测试结果准确可靠,满足废气中氯化氰含量的测试。  相似文献   

2.
气相色谱法测定工业废气中的丙酮   总被引:3,自引:0,他引:3  
用活性炭吸附管采集吸附工业废气中的丙酮,经二硫化碳解吸后由自动进样器送入气相色谱仪中分离并由FID检测器检测。2 mL二硫化碳解吸溶剂中丙酮的绝对量在1.58~6.32 mg时,测定结果的相对标准偏差为2.4%~3.7%(n=5)。当样品采集量为10 L时,方法检出限为0.4 mg/m3。所用活性炭采样管对丙酮的吸附效果良好,100 g活性炭对丙酮的穿透容量大于15 mg。二硫化碳溶剂对吸附在活性炭中的丙酮解吸效果较好,丙酮加标量为3.95~15.80 mg时,解吸效率为93.8%~100.9%。  相似文献   

3.
建立了直接进样测定工业废气中苯乙烯的气相色谱法.工业废气样品通过气体进样阀进入气相色谱仪中进行分离和检测,采用0.25 mL气体进样阀时,方法的检出限为1.4 mg/m3,苯乙烯含量在3.19~51.0 mg/m3时,测定结果的相对标准偏差为2.19%~4.50%(n=5),与行业标准HJ 583-2010,HJ 584-2010相比,该方法操作简便、快速,适合工业废气中苯乙烯的快速测定.  相似文献   

4.
气相色谱法测定汽油馏分中的单体芳烃   总被引:2,自引:0,他引:2  
金珂  杨海鹰 《色谱》2003,21(1):85-87
采用三柱一阀气相色谱系统单次进样、归一化法定量分析初馏至200 ℃的汽油(包括含有醇类、醚类的成品汽油)中的芳烃含量。具体操作:样品进入系统后分为两路,一路经过分析柱1(Col.2)后直接到检测器;另一路进入预切柱(Col.1),烷烃和烯烃先于芳烃流出,待烷烃和烯烃放空后将阀切换到反吹状态,Col.1中的芳烃被反吹出来,进入分析柱2(Col.3),经过分离后到检测器,经计算得到样品分析结果。该法简便、快速、样品用量少、测试范围宽,避免了汽油中其他组分对芳烃测定的干扰。  相似文献   

5.
建立气相色谱法同时测定固定污染源中6种丙烯酸酯。采用气袋采样,直接进样,以气相色谱法同时测定固定污染源中6种丙烯酸酯。6种丙烯酸酯在0.5~20μmol/mol范围内与色谱峰面积的线性关系良好,相关系数均不小于0.998,方法检出限为0.5~2.0 mg/m3。对低、中、高三种浓度标准气体进行分析,测定结果的相对标准偏差(n=6)分别为1.8%~3.5%、3.1%~4.1%和1.9%~3.0%;相对误差(n=6)分别为-6.2%~5.5%、1.2%~8.2%和-6.0%~(-4.1%),实际样品加标回收率为91.3%~125%。该方法适合于固定污染源废气中丙烯酸酯化合物的分析。  相似文献   

6.
气相色谱法测定工业污水中甲醇   总被引:5,自引:0,他引:5  
甲醇主要对血管有麻痹作用及可导致神经变性 ,特别严重的是损害视神经。所以甲醇作为酒中的卫生指标必须测定 ,国家已有标准检验方法和标准限值[1] 。但对某些化工厂最终排放水中甲醇的测定方法及标准限值国内尚未见报道。本文采用气相色谱法直接测定工业污水中的甲醇[2 ] ,相对标准偏差为 1.9%,回收率为 98.8%。1 试验部分1.1 仪器与试剂SP 5 0 2气相色谱仪 ,由岛津版工作站计算结果甲醇标准溶液 :10mg·ml- 1,称取甲醇 1 0 0 0 g ,置于 10 0ml容量瓶中 ,加水稀释至刻度。置冰箱中保存。1.2 色谱条件长 2m的不锈钢柱 ,固定…  相似文献   

7.
提出了甲醇中共存杂质(丙酮、乙酸甲酯、乙醇)和微量芳烃(乙苯、对二甲苯、间二甲苯和邻二甲苯)含量的气相色谱测定方法。用INNOWAX色谱柱,采取程序控制柱温升温,用氢火焰离子检测器,各种化合物完全分离。丙酮、乙酸甲酯和乙醇的线性范围为4.0~20mg.L-1,各芳烃化合物的线性范围为0.4~2.0mg.L-1。方法用于甲醇样品的分析,加标回收率在88%~114%之间,相对标准偏差(n=7)为2.56%~4.68%。  相似文献   

8.
9.
气相色谱法快速鉴定植物油   总被引:4,自引:1,他引:3  
田文荣  余仲建 《色谱》1990,8(6):393-394
分析植物油的经典方法是测定多种物理常数和进行化学分析。方法十分烦杂,费时费事,结果还不一定可靠,特别是鉴别伪劣品更困难。本文用气相色谱法快速鉴定国内常见的十三种植物油。试样经甲酯化后用φ2mm×1m 5%Reoplex 400柱在15min内就能很好地分离月桂酸、肉豆蔻酸、软脂酸、油酸、亚油酸、亚麻酸、花生烯酸和芥酸的甲酯。提出以脂肪酸甲酯作为保留指数的基准物,测  相似文献   

10.
按照HJ/T 55或GB/T 16157的相关规定,用固定量0.12mol·L~(-1)盐酸溶液吸收采集固定污染源废气中三甲胺。分取样品溶液10.00mL,移至顶空瓶中,加入氯化钠3.2g和硫酸钾1.0g,并用微量注射器加入质量分数为50%的NaOH溶液500μL和氨水100μL,立即密封顶空瓶,在顶空平衡温度为80℃,平衡时间为30min的条件下进行顶空采样。选择CP-Volamine石英毛细管色谱柱进行三甲胺及其他5种研究的脂肪胺类化合物的定量分离,采用氢火焰离子化检测器(FID)进行检测。分别按HJ/T 55及GB/T 16157规定的方法各取三甲胺标准气体20L,分别进行7组平行试验,测得前一采样方法的检出限[t_(n-1,0.99))×s]为0.004mg·m~(-3),后一采样方法的检出限[t_(n-1,0.99))×s]为0.02mg·m~(-3)。另取高浓度(0.510μmol·mol~(-1))、中浓度(0.102μmol·mol~(-1))及低浓度(0.010 2μmol·mol~(-1))等3种浓度的三甲胺标准气体,按规定方法采样并分析6次,计算得三甲胺的回收率在90.1%~108%之间,测定值的相对标准偏差(n=6)在2.2%~6.7%之间。应用此方法分析实际样品,测定结果表明该方法能满足国家标准GB 14554-93及天津市和上海市两地方标准对恶臭污染物排放的规定,并配合上述标准的执行。  相似文献   

11.
王桂华  王钧效  黄学政  陆家祥  刘娜 《色谱》2004,22(4):445-448
采用气相色谱-质谱联用技术(GC/MS)对柴油机排气微粒中的可溶性有机组分(SOF)进行了分离分析。SOF分析液样品采用超声提取法制取。GC条件为:SE-50型石英毛细管色谱柱(30 m×0.2 mm i.d.×0.2 μm);程序升温:初始温度100 ℃,恒温2.0 min,以4.0 ℃/min升至160 ℃,再以8 ℃/min升至250 ℃,恒温31.75 min;汽化室温度260 ℃;载气为氦气,柱头压力45 kPa;进样量1 μL。MS条件为:电子轰击离子源,电子轰击能量70 eV;倍增器电压18  相似文献   

12.
气相色谱/质谱法测定熏肉中的多环芳烃   总被引:22,自引:0,他引:22  
李永新  张宏  毛丽莎  孙成均 《色谱》2003,21(5):476-479
建立了熏肉中多环芳烃的气相色谱/质谱(GC/MS)测定方法。样品经正己烷-丙酮(体积比为1∶1)超声波提取、氧化铝柱净化后,用GC/MS分离测定。优化了25种多环芳烃(PAHs)化合物的分离测定条件。结果 25种PAHs回收率范围为48.5%-106.5%;日内(n=7)相对标准偏差为3.75%-7.95%。方法具有灵敏度高、准确度好、能同时分离测定20余种多环芳烃化合物的优点,适合于熏肉中多环芳烃化合物的分析测定。  相似文献   

13.
快速毛细管气相色谱分析白酒中的香味成分   总被引:1,自引:0,他引:1  
本文建立了快速毛细管气相色谱法,在10 min内分离了白酒中的香味成分,并对其中的醇、醛、酸、酯进行定性分析,对主要呈味成分己酸乙酯进行定量分析,方法重复性好,回收率较高。与常规毛细管色谱法相比,快速毛细管气相色谱法有效地缩短了分析时间,提高了白酒的分析效率。  相似文献   

14.
全二维气相色谱用于轻质石油馏分中芳烃含量的测定   总被引:2,自引:0,他引:2  
李艳艳 《色谱》2006,24(4):380-384
建立了采用全二维气相色谱(GC×GC)技术一次进样完成轻质石油馏分中非芳烃、一环芳烃和二环芳烃的分离、定性 和定量。通过对柱系统的选择和色谱条件的优化,实现了一次全二维气相色谱分析即完成轻质石油馏分的族组成分离以及 目标化合物的分离。方法的加标回收率为89.5%~106.1%;样品中各组分含量重复测定的相对标准偏差均不大于5.8%,能 够满足样品测定的精密度和准确性要求,且完成1次分析最多只需要30 min。  相似文献   

15.
The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed inside a metal tube which can be heated, and cooled, much more rapidly than any conventional GC oven. The EZ Flash assembly can generate temperature ramps up to 1200°/min and can be cooled down from 300 to 50°C in 30 s. Samples were injected via a conventional split/splitless injector and transferred to the GC column. The combination of a short column (5 m×0.25 mm i. d.), a high gas flow rate (up to 10 mL/min), and fast temperature programmes typically decreased analysis times from 30 min to about 2.5 min. Both the split and splitless injection mode could be used. With n-alkanes as test analytes, the standard deviations of the retention times with respect to the peak width were less than 15% (n = 7). First results on RSDs of peak areas of less than 3% for all but one n-alkane indicate that the technique can also be used for quantification. The combined use of a short GC column and fast temperature gradients does cause some loss of separation efficiency, but the approach is ideally suited for fast screening as illustrated for polycyclic aromatic hydrocarbons, organophosphorus pesticides, and triazine herbicides as test compounds. Total analysis times – which included injection, separation, and equilibration to initial conditions – were typically less than 3 min.  相似文献   

16.
Biodiesel serves as a promising alternative to the conventional petroleum fuels and is considered to be a renewable source of energy which can be used in compression-ignition engines with minimum or no modifications. Two biodiesels derived from Jatropha curcas seeds and marine microalga Chlorella variabilis were substituted for petrodiesel and 16 priority polycyclic aromatic hydrocarbons (United States Environmental Protection Agency) were targeted for quantification through gas chromatography equipped with a flame ionization detector. For comparison, petrodiesel was selected as a control, and the analyte concentrations were calculated through calibration curves with correlation coefficient ranging from 0.9909 to 0.9999. The analytical figures of merit were determined for each analyte. The relative standard deviations for intra-day repeatability and inter-day reproducibility were in the range of 4.47–8.75%. The results indicated a significant decrease of around 77 and 68% in the overall polycyclic aromatic hydrocarbon concentrations in the particulate matter originating from J. curcas and microalga C. variabilis biodiesel, respectively. This study is perceived as an important step toward describing the green emission behavior of these biodiesels and their merits compared to the conventional petroleum-based fuels.  相似文献   

17.
一种直热式快速气相色谱快速升温装置的设计   总被引:1,自引:0,他引:1  
用大电流脉冲直接加热不锈钢毛细管柱, 将脉冲间隔调整到正好使柱管局部完成热平衡, 用快速PID技术控制脉冲频率和宽度, 设计了一种直热式快速升温装置. 该装置最高升温速率可达到5 ℃/s, 升温范围 40~150 ℃, 程序升温线性相关系数大于0.9996, 最大功耗74 W, 加热平均功耗小于50 W, 在34 s内完成nC8~nC17 10种正构烷烃的分离, 保留时间重复精度误差RSD在0.22%~0.55%之间, 降温和平衡时间仅为30 s. 与常规气相色谱仪相比, 该装置分析挥发性和半挥发性有机物速度可提高20倍以上, 专用于快速气相色谱仪.  相似文献   

18.
气相色谱法测定大气中非甲烷总烃量的探讨   总被引:3,自引:0,他引:3  
用直接进样差量气相色谱法测定非甲烷总烃(NMHC)量。实验研究了分析条件、气源和定量方式等对NMHC定量准确度的影响。综合考虑较低基线响应和较高灵敏度等,选择合适的氢气和空气流速,测得NMHC方法检出限为0.03 mg/m3(以碳计),该法可保证低浓度样品分析的准确度。实验结果表明,标准气中CH4和C3H8遵从碳数响应规律,其配比不会影响定量的准确性,可根据样品总烃和甲烷比例适当配制;对于低浓度样品,以空气为底气的总烃响应灵敏度低于氮气为底气的总烃响应灵敏度,采用以氮气为底气的标准气来定量空气中总烃的含量时,测定结果将产生较大偏差,甚至可能产生负值,应该用以除烃空气为底气的标准气来定量空气样品;某些样品测定过程中,总烃不只出一个峰,需要调节相关条件再进行测定。  相似文献   

19.
吹扫-捕集气相色谱法测定水中挥发性卤代烃   总被引:5,自引:0,他引:5  
研究建立了吹扫 捕集法富集样品 ,利用HP 1大口径厚液膜通用型熔融石英毛细管柱 (30m× 0 .5 3mm×2 .6 5 μm) ,ECD检测器 ,测定水中 10种挥发性卤代烃的方法 ,确定了最佳吹扫 捕集条件 .结果表明 :水样体积为 5mL时 ,标准偏差在 0 .0 2~ 0 .0 7μg L之间 ,变异系数在 1.0 9%~ 3.2 8%之间 ,加标回收率为 94.0 %~ 10 7%之间 ,10种物质的检出限在 0 .0 7~ 0 .19μg L之间  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏