首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive method has been developed for species selective determination of chromium(III) and chromium(VI) in water by electrothermal atomic absorption spectrometry. The procedure is based on selective absorption of Cr(III) on a cellulose micro column (pH 11, 0.5 mol L(-1) NaCl). Total chromium was subsequently determined after appropriate reduction of Cr(VI) to Cr(III). Recoveries of more than 97% were found. A concentration factor of 100 was achieved. The relative standard deviations (n=10) at the 40 ng L(-1) level for chromium(III) and chromium(VI) were 2.3% and 1.8% and corresponding limits of detection (based on 36) were 1.8 ng L(-1) and 5.1 ng L(-1), respectively. No interference effects have been observed from other investigated species and the method has been successfully applied to natural water samples.  相似文献   

2.
Zhang N  Suleiman JS  He M  Hu B 《Talanta》2008,75(2):536-543
A new chromium(III)-imprinted 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS)-functionalized silica gel sorbent was synthesized by a surface imprinting technique and was employed as a selective solid-phase extraction material for speciation analysis of chromium in environmental water samples prior to its determination by inductively coupled plasma mass spectrometry (ICP-MS). The prepared Cr(III)-imprinted silica gel shows the selectivity coefficient of more than 700 for Cr(III) in the presence of Mn(II). The static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cr(III) were 30.5 mg g(-1) and 13.4 mg g(-1). It was also found that Cr(VI) could be adsorbed at low pH by the prepared imprinted silica gel, and this finding makes it feasible to enrich and determine Cr(VI) at low pH without adding reducing reagents. The imprinted silica gel sorbent offered a fast kinetics for the adsorption and desorption of both chromium species. Under the optimized conditions, the detection limits of 4.43 pg mL(-1) and 8.30 pg mL(-1) with the relative standard deviations (R.S.D.s) of 4.44% and 4.41% (C=0.5 ng mL(-1), n=7) for Cr(III) and Cr(VI) were obtained, respectively. The proposed method was successfully applied to the speciation of trace chromium in environmental water samples. To validate the proposed method, two certified reference materials were analyzed and the determined values were in a good agreement with the certified values. The developed method is rapid, selective, sensitive and applicable for the speciation of trace chromium in environmental water samples.  相似文献   

3.
A new solid phase extraction (SPE) method has been developed for the speciation of Cr(III) and Cr(VI). This method is based on the adsorption of Cr(VI) on modified alumina‐coated magnetite nanoparticles (ACMNPs). Total chromium in different samples was determined as Cr(VI) after oxidation of Cr(III) to Cr(VI) using H2O2. The chromium concentration has been determined by flame atomic absorption spectrometric (FAAS) technique and amount of Cr(III) was calculated by substracting the concentration of Cr(VI) from total chromium concentration. The effect of parameters such as pH, amount of adsorbent, contact time, sample volume, eluent type, H2O2 concentration and cetyltrimethylammonium bromide (CTAB) concentration as modifier on the quantitative recovery of Cr(VI) were investigated. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation (RSD) of Cr(VI) were 140 (for 350 mL of sample solution), 0.083 ng mL?1, 0.1‐10.0 ng mL?1 and 4.6% (for 5.0 ng mL?1, n = 7), respectively. This method avoided the time‐consuming column‐passing process of loading large volume samples in traditional SPE through the rapid isolation of CTAB@ACMNPs with an adscititious magnet. The proposed method was successfully applied to the determination and speciation of chromium in different water and wastewater samples and suitable recoveries were obtained.  相似文献   

4.
Hagendorfer H  Goessler W 《Talanta》2008,76(3):656-661
Due to its extensive use in industrial processes, large quantities of chromium compounds are discharged into the environment. Common approaches for the speciation of Cr employ the determination of Cr(VI) and total Cr. The focus of the present work was a separation of Cr(III) and Cr(VI) species, with a minimum of sample preparation, by keeping an eye on the more relevant and toxic Cr(VI). For the successful simultaneous separation of both chromium species we implemented a RSpak NN-814 4DP (PEEK, 4 mm x 150 mm) multi-mode column using an eluent containing 90 mM ammonium sulfate and 10 mM ammonium nitrate, adjusted to pH 3.5. At a flow of 0.3 mL min(-1) the separation of both Cr species was possible within 8 min. Further the octopole reaction system of the inductively coupled plasma mass spectrometer was systematically studied and optimised to reduce the influence of polyatomic interferences. The major advantage of the developed method compared to published methods is that a derivatisation of the Cr(III) species--an invasion in the speciation--is not required. With the used multi-mode column both chromium species are retained. Furthermore the pH of the mobile phase (pH 3.5) prevents reduction of Cr(VI) as well as precipitation of Cr(III) during the analysis. A limit of determination of approximately 0.5 microg L(-1) for both chromium species with an injection volume of 25 microL was obtained. The optimised method was successfully applied to the determination of Cr(VI) in cement samples as well as chromium speciation analysis in homeopathic drugs.  相似文献   

5.
Under ultrasonic irradiation, organic fluorescence nanoparticles have been prepared by a reprecipitation method. Compared with single organic fluorophores, these nanoparticles are brighter, more stable against photobleaching and more water-soluble. They also have high room-temperature fluorescence quantum yields (approximately 20%) and a long fluorescence lifetime (approximately 0.2 micros). Based on the fluorescence quenching of nanoparticles by chromium(VI), a method for the selective determination of chromium(VI) without the separation of chromium(III) in water was developed. Under the optimal conditions, the linear range of the calibration curve was 7.0 x 10(-6) - 1.0 x 10(-4) mol L(-1). The detection limit was 2.8 x 10(-6) mol L(-1). The method is characterized by a short reaction time, stable fluorescence signals, simplicity and high selectivity. The present assay has been applied to the selective quantification of Cr(VI) in wastewater with satisfactory results.  相似文献   

6.
微乳相萃取分离富集-原子吸收光谱法分析铬形态   总被引:1,自引:0,他引:1  
建立了一种微乳相萃取分离-石英双缝管原子捕集火焰原子吸收光谱法(STAT-FAAS)分析环境水样中铬形态的新方法。该方法中,Cr(Ⅲ)与8-羟基喹啉反应形成的疏水性配合物,经萃取进入微乳相,Cr(Ⅵ)留在水溶液中,从而实现Cr(Ⅲ)与Cr(Ⅵ)的相互分离。Cr(Ⅵ)含量的测定通过过氧化氢溶液将Cr(Ⅵ)还原为Cr(Ⅲ),按同样方法分析。实验对微乳相萃取的主要影响因素进行了优化。结果表明,经优化后实验条件为:平衡温度80℃,平衡时间10min,溶液酸度pH=9.0,NH3-NH4Cl缓冲溶液用量2.0mL,8-HQ用量0.05mmol;TritonX-100微乳液组成:m(TritonX-100):m(正戊醇):m(正己烷):m(水)=3.0:15:1.5:4.0。在此条件下,萃取的富集倍数达到25倍(50mL起初样品溶液/2mL最终测定液),线性范围为2.5~500μg/L,检出限为0.62μg/L,相对标准偏差(RSD)为3.8%(n=10,c=10μg/L)。本方法已成功地应用于电镀废水中铬形态分析。  相似文献   

7.
A simple, inexpensive method based on solid-phase extraction (SPE) on sawdust from Cedrus deodera has been developed for speciation of Cr(III) and Cr(VI) in environmental water samples. Because different exchange capacities were observed for the two forms of chromium at different pH—Cr(III) was selectively retained at pH 3 to 4 whereas Cr(VI) was retained at pH 1—complete separation of the two forms of chromium is possible. Retained species were eluted with 2.5 mL 0.1 mol L−1 HCl and 0.1 mol L−1 NaOH. Detection limits of 0.05 and 0.04 μg mL−1 were achieved for Cr(III) and Cr(VI), respectively, with enrichment factors of 100 and 80. Recovery was quantitative using 250 mL sample volume for Cr(III) and 200 mL for Cr(VI). Different kinetic and thermodynamic properties that affect sorption of the chromium species on the sawdust were also determined. Metal ion concentration was measured as the Cr(VI)–diphenylcarbazide complex by UV–visible spectroscopy. The method was successfully applied for speciation of chromium in environmental and industrial water samples.  相似文献   

8.
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer-scale TiO2 particles) was prepared by a sol-gel method and characterized by X-ray diffraction and scanning electron microscopy. The adsorptive behavior of Cr(III) and Cr(VI) on immobilized nanometer TiO2 was assessed. Cr(III) was selectively sorbed on immobilized nanometer TiO2 in the pH range of 7-9, while Cr(VI) was found to remain in solution. A sensitive and selective method has been developed for the speciation of chromium in water samples using an immobilized nanometer TiO2 microcolumn and inductively coupled plasma atomic emission spectrometry. Under optimized conditions (pH 7.0, flow rate 2.0 mL/min), Cr(III) was retained on the column, then eluted with 0.5 mol/L HNO3 and determined by ICP-AES. Total chromium was determined after the reduction of Cr(VI) to Cr(III) by ascorbic acid. The adsorption capacity of immobilized nanometer TiO2 for Cr(III) was found to be 7.04 mg/g. The detection limit for Cr(III) was 0.22 ng/mL and the RSD was 3.5% (n = 11, c = 100 ng/ mL) with an enrichment factor of 50. The proposed method has been applied to the speciation of chromium in water samples with satisfactory results.  相似文献   

9.
Methods for the on-line chromatographic preconcentration of Cr(III) and Cr(VI) have been developed. Cr(VI) has been preconcentrated on an RP C18 silica based column with tetrabutylammonium-bromide (TBABr) as ion-pairing agent. Specially for Cr(III) a new and effective preconcentration technique based on the sorption of Cr(III)-ions in a C18 column in presence of KH-phthalate has been developed. The efficiency of sample introduction into the atomic emission spectrometer could be improved by hydraulic high pressure nebulization. For the detection of chromium the acetylene/N(2)O flame has been used as a powerful emission spectrometric source. Applying these steps the detection limit (3sigma) could be improved to 25 pg/mL for Cr(III) and to 20 pg/mL for Cr(VI). The method has been applied for the chromium speciation in natural water samples.  相似文献   

10.
Mandiwana KL 《Talanta》2008,74(4):736-740
A method has been developed that leaches Cr(VI) selectively from soil samples. Hexavalent chromium was leached completely from soil with 0.01molL(-1) Na(3)PO(4). This was achieved by boiling the soil-reagent solution mixture for a period of 5min. The leached Cr(VI) was then quantified by electrothermal atomic absorption spectrometry (ET-AAS) after filtration of the sample solutions through Hydrophilic Millipore PVDF 0.45microm filter. Statistical evaluations indicated that the new developed method is reliable since neither its comparison with the established method nor the comparison of the sum of the concentrations of chromium species to that of the total concentration of chromium show any difference at 95% level of confidence. The spiking of soil samples with Cr(III) standards before pretreatment show that Cr(III) was not oxidized to Cr(VI) during leaching as the Cr(VI) content never increased. The detection limit established was 0.07microg g(-1), which is an improvement to that of the US EPA method 3060A by a factor of more than 500. The maximum concentrations of Cr(VI) found in soil samples collected around the new chromium mine was 8.0microg g(-1) and falls within acceptable level of 15microg g(-1) in accordance with the Italian Guidelines.  相似文献   

11.
Girard L  Hubert J 《Talanta》1996,43(11):1965-1974
We have studied the speciation of chromium (VI) in stainless-steel welding dusts. The approach used for the analysis of Cr(VI) and total Cr relies on a flow-injection analyzer (FIA) equipped with two different sequential detectors. The system measures Cr(VI). by colorimetry (with 1,5-diphenyl carbohydrazide) and total chromium content by flame atomic absorption spectroscopy (AAS). The extraction of the samples of welding-fume dusts is achieved in a buffer solution (acetic acid and sodium acetate at pH 4). This extraction procedure gives a 96% recovery of chromium (VI). The FIA-AAS system that has been described is also more sensitive, has a lower detection limit (0.005 mug ml(-1)) and gives a better precision (< 1%) than other equivalent systems that have been previously described.  相似文献   

12.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

13.
A method for speciation of Cr(III) and Cr(VI) in real samples has been developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its pyrrolidinedithiocarbamate (APDC) complex by using a column containing Amberlite XAD–2000 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of pH, flow‐rate, adsorption and batch capacity and effect of various metal cations and salt anions on the sorption onto the resin were investigated. The adsorption is quantitative in the pH range of 1.5–2.5, and Cr(VI) ion was desorbed by using H2SO4 in acetone. The recovery of Cr(VI) was 97 ± 4 at a 95% confidence level. The highest preconcentration factor was 80 for a 200 mL sample volume. The adsorption and batch capacity of sorbent were 7.4 and 8.0 mg g?1 Cr(VI), respectively, and loading half time was 5.0 min. The detection limit of Cr(VI) is 0.6 μg/L. The procedure has been applied to the determination and speciation of chromium in stream water, tap water, mineral spring water and spring water. Also, the proposed method was applied to total chromium preconcentration in microwave digested moss and rock samples with satisfactory results. The developed method was validated with CRM‐TMDW‐500 (Certified Reference Material Trace Metals in Drinking Water) and BCR‐CRM 144R s (Certified Reference Material Sewage Sludge, Domestic Origin) and the results obtained were in good agreement with the certified values. The relative standard deviations were below 6%.  相似文献   

14.
A high-performance liquid chromatographic method with diode array detection (HPLC-DAD), based on chelation with ammonium pyrrolidinedithiocarbamate (APDC), has been developed for the determination of chromium species. Determination of Cr3+, CrO42-, and Cr2O72- was performed for standards and synthetic environmental matrixes. This method is robust, rugged, and can be used for rapid routine determination of chromium species with high precision and reliability. Sample pretreatment is simple. The method is capable of discriminating not only between Cr(III) and Cr(VI) but also between the chemical forms of Cr(VI) - CrO42- and Cr2O72-. By analysis of numerous samples the method has been shown to be selective, sensitive, and free from matrix interference, which is crucial for the determination of chromium species in difficult-to-analyze environmental matrixes. This method has been validated by means of an interlaboratory study. Although different speciation techniques were used during this study, there was good agreement between results from the two laboratories. The method detection limits were 7 and 4 mg L(-1) for Cr3+ and Cr2O72-, respectively. Recoveries of the analytes from spiked samples were 98% and 100% for Cr3+ and Cr2O72-, respectively. Both were based on a 10-mL sample volume spiked with 0.4 mg L(-1) chromium.  相似文献   

15.
Gao RM  Zhao ZQ  Zhou QZ  Yuan DX 《Talanta》1993,40(5):637-640
A new spectrophotometric determination method of hexavalent chromium in waste water and plating baths is described based on the oxidation of beryllon III by chromium(VI) in 0.02M sulphuric acid medium. The decrease in the absorbance of beryllon III was measured at 482 nm with an apparent molar absorptivity of 5.15 x 10(4)1.mole(-1).cm(-1). Beer's law was obeyed for chromium(VI) over the range 0-25 mug/25 ml. After the oxidation of Cr(III) to Cr(VI) by ammonium persulphate, total chromium can be determined. Therefore, chromium(III) can be calculated by subtracting chromium(VI) from total chromium. The detection limit is 0.015 and 0.020 mug/25 ml for chromium(VI) and total chromium, respectively. A sensitive spectrophotometric method for trace Cr(III) and Cr(VI) in waste water and plating baths was developed with good precision and accuracy. The reaction is also discussed.  相似文献   

16.
The catalytic adsorptive stripping voltammetry (CAdSV) has been applied to physico-chemical chromium speciation study in the upper Dunajec catchment, severely polluted by the tannery wastewater. The method is based on the adsorptive preconcentration of the Cr(III)-diethylenetriammine-N,N,N′,N″,N″-pentaacetic acid (DTPA) complex and the utilization of the catalytic reaction in the presence of nitrate. Under optimized conditions the CAdSV enables the oxidation state speciation study of Cr content by direct determination of Cr(VI) in the presence of the predominant Cr(III) concentration with the detection limit for chromium(VI) of 0.08 nM and the linearity range from 0.1 to 80 nM obtained for 20 s of accumulation, as well as the determination of total Cr after UV oxidation of Cr(III) to Cr(VI). Due to the difference in the chemical properties of different chromium species the CAdSV method makes possible a speciation study of Cr(III) and Cr(VI) oxidation state. The RSD of the determination of Cr(VI) and Cr(III) varies from 0.5 to 5%. It has been proved that in natural water in which strong complexants of Cr(III) such a humid acids are presented, Cr(VI) can be determined accurately in the presence of high excess of Cr(III). Fractionation of selected water samples with tangential flow filtration (TFF, cut-off 10 and/or 1 kDa) provides insight into physical Cr speciation, i.e. partitioning of the Cr(VI) and Cr(III) between the colloidal and the dissolved fractions. It has been shown that the content of the Cr species in the Dunajec river depends on the season, and is significantly higher in autumn and winter during the most intensive tanneries production processes. The concentration of total Cr exceeds occasionally the legally admissible level. A large fraction of total Cr(III) concentration is associated with the colloidal material, while Cr(VI) occurs solely in the truly dissolved form.  相似文献   

17.
Electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry (ETV-ICP-ES) has been used for the sequential determination of Cr(III) and Cr(VI). The method is based on the difference between the chelate reactions of the two Cr species and acetylacetone. Cr(III) chelate was separated from Cr(VI) and determined with use of acetylacetone as chemical modifier. The retained Cr(VI) in graphite tube was analyzed subsequently, after addition of polytetrafluoroethylene (PTFE) as chemical modifier. The different factors affecting the vaporization behavior of Cr(III) acetylacetonate were investigated in detail. The detection limits for Cr (III) and Cr(VI) were 0.56 and 1.4 ng mL(-1), respectively, and relative standard deviations for 0.1 microg mL(-1) Cr(III) and 0.1 microg mL(-1) Cr(VI) were 2.5% (n = 6) and 4.8% (n = 6), respectively. The linear ranges of the calibration curve for both Cr(IIl) and Cr(VI) covered three orders of magnitude. The proposed method was used to analyze water samples with satisfactory results.  相似文献   

18.
Methods for the on-line chromatographic preconcentration of Cr(III) and Cr(VI) have been developed. Cr(VI) has been preconcentrated on an RP C18 silica based column with tetrabutylammonium-bromide (TBABr) as ion-pairing agent. Specially for Cr(III) a new and effective preconcentration technique based on the sorption of Cr(III)-ions in a C18 column in presence of KH-phthalate has been developed. The efficiency of sample introduction into the atomic emission spectrometer could be improved by hydraulic high pressure nebulization. For the detection of chromium the acetylene/N2O flame has been used as a powerful emission spectrometric source. Applying these steps the detection limit (3) could be improved to 25 pg/mL for Cr(III) and to 20 pg/mL for Cr(VI). The method has been applied for the chromium speciation in natural water samples.  相似文献   

19.
A simple, rapid, and selective on-line method for the speciation and determination of Cr(III) and Cr(VI) in aqueous solutions by ion-pairing HPLC coupled with flame atomic absorption spectrometry (FAAS) is described. The composition of the mobile phase has been optimized for better separation. The effects of column temperature, volume of injection loop, fuel flow rate of FAAS, and nebulizer suction rate of FAAS have also been investigated. Separation is accomplished in almost 2.5 min on a 25 cm length C18 column at 40 degrees C. The selectivity of the method has been established by investigating the effect of interfering elements on chromium determination. The detection limit (3sigma) achieved by the method was calculated as 3.7 ng/mL for Cr(III) and 2.0 ng/mL for Cr(VI). The proposed method has been validated by analyzing certified reference material (BCR 544) and successfully applied to the analysis of drinking water and wastewater samples with a relative error below 6%.  相似文献   

20.
A simple speciation, separation and enrichment method has been developed for the determination of Cr(III) and Cr(VI) ions in different samples by ion-pair solvent extraction with a β-diketone ligand, 2-(4-methoxybenzoyl)-N′-benzylidene-3-(4-methoxyphenyl)-3-oxo-N-phenyl-propono hydrazide (MBMP). Cr(III) was separated from Cr(VI) as Cr(III)-(MBMP)-perchlorate ternary ion-pair complex. The influences of various analytical parameters including pH, amount of reagent, shaking time, sample volume and ionic strength on the recovery of Cr(III) and/or Cr(VI) were investigated. Total chromium was obtained after reducing Cr(VI) to Cr(III) with NH2OH?·?HCl. Recoveries were found to be higher than 95% and the relative standard deviation (RSD) was less than 2%. The method detection limit based on 3σ criterion for Cr(III) was found to be 0.32?µg?L?1. The formed ternary ion-pair complex, Cr(III)?:?MBMP?:?2ClO4, has a molar ratio of 1?:?1?:?2. The developed method has been applied successfully to the speciation of chromium in various natural water, soil, sediment and hair samples with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号