首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The application of nonpolar matrices for the analysis of low molecular weight nonpolar synthetic polymers using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is demonstrated. Anthracene, pyrene, and acenaphthene were utilized as nonpolar matrices for the analysis of polybutadiene, polyisoprene, and polystyrene samples of various average molecular weights ranging from about 700 to 5000. The standard MALDI-MS approach for the analysis of these types of polymers involves the use of conventional acidic matrices, such asall-trans-retinoic acid, with an additional cationization reagent. The nonpolar matrices used in this study are shown to be as equally effective as the conventional matrices. The uniform mixing of the nonpolar matrices and the nonpolar analytes enhances the MALDI-MS spectral reproducibility. Silver salts were found to be the best cationization reagents for all of the cases studied. Copper salts worked well for polystyrene, poorly for polyisoprene, and not at all for polybutadiene samples. These matrices should be useful for the characterization of hydrocarbon polymers and other analytes, such as modified polymers, which may potentially be sensitive to acidic matrices.  相似文献   

2.
3.
Oxidized carbon nanotubes (CNTs), which can form a stable homogeneous suspension in water close to a solution phase, were synthesized and used for matrix-assisted desorption/ionization mass spectrometric (MALDI-MS) analysis of biomolecules. Infrared (IR) spectra, transmission electron microscopy (TEM) and particle size analysis were used for the characterization of the oxidized CNTs. The results indicate that the physical structure of the CNTs was not damaged, but carboxylate groups were introduced onto the surface of the CNTs. In addition, impurities including amorphous carbon, which is one of the main reasons for ion source contamination, were destroyed by the oxidization. The carboxyl groups on the oxidized surface of the CNTs can not only provide an additional proton source, but can also increase the surface polarity and solubility of the CNTs, making it easier to manipulate which is important for MALDI analysis of some biomolecules, especially larger peptides and proteins. The oxidized CNTs were successfully applied to the analysis of neutral oligosaccharides, peptides, and insulin, and thus promise to be an efficient matrix for MALDI-MS analysis of biomolecules.  相似文献   

4.
Direct analysis of proteins adsorbed onto the surface of nylon membranes has been performed at the picomole level by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). Nylon-66 and positive charge-modified nylon (Zetabind) membranes fixed to MALDI probe tips were successfully employed to analyze picomole quantities of sample that were adsorbed onto these inert supports prior to adding a matrix-containing solution. Proteins and peptides are readily solubilized from these types of membrane with conventional matrix solvents and cocrystallize with the matrix on the membrane surface. Because solubilization of membrane-adsorbed protein is necessary for successful sample preparation, nylon membranes are more suitable for use with MALDI-MS than other protein transfer membranes such as polyvinylidene difluoride or nitrocellulose. When compared to samples prepared conventionally, no apparent loss of sensitivity or resolution is observed when analysis by MALDI-MS is performed from nylon-66 or positive charge-modified nylon membranes. Detection limits and resolution are not apparently affected by the membrane immobilization/washing procedure, and no change in the mass accuracy is observed when analysis is performed on the nylon surface. However, there is a time shift (increase) in ion flight time when analysis by MALDI-time-of-flight-MS is performed directly from the membrane fixed to the probe tip (about 200 ns for an ion of mass 379.3). To maintain mass accuracy, the use of internal standards or external calibration performed on a membrane support was necessary. The immobilization of proteins on nylon membranes can be used to facilitate removal of water-soluble contaminants because the sample is retained when the membrane is immersed in water prior to adding the matrix solution. The feasibility of performing both chemical and enzymatic modifications of proteins adsorbed onto inert nylon supports prior to analysis by MALDi-MS is also demonstrated.  相似文献   

5.
An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed with a commercial MALDI-TOF mass spectrometer. The method was tested with a 41-sample library. MALDI-TOFMS was found to give the needed sensitivity, accurate mass measurement, and soft ionization necessary for structure confirmation, even of mixtures. A mass accuracy of 5 ppm or less was obtained in over 80% of known compound measurements. A mass accuracy better than 10 ppm was obtained for all measurements of known compounds. Analyses of parallel synthesis products resulted in 77% of the measurements with a mass accuracy of 5 ppm or better.  相似文献   

6.
Berndt P  Hobohm U  Langen H 《Electrophoresis》1999,20(18):3521-3526
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry of protein samples from two-dimensional (2-D) gels in conjunction with protein sequence database searches is frequently used to identify proteins. Moreover, the automatic analysis of complete 2-D gels with hundreds and even thousands of protein spots ("proteome analysis") is possible, without human intervention, with the availability of highly accurate mass spectrometry instruments, and high-throughput facilities for preparation and handling of protein samples from 2-D gels. However, the lack of software for precise automatic analysis and annotation of mass spectra, as well as software for in-batch sequence database queries, is increasingly becoming a significant bottleneck for the proteomics work flow. In the present paper we outline an algorithm for reliable, accurate, and automatic evaluation of mass spectrometric data and database searches. We show here that simply selecting from the sequence database the protein that has the most matching fragment masses often leads to false-positive results. Reliable protein identification is dependent on several parameters: the accuracy of fragment mass determination, the number of masses submitted for query, the mass distribution of query masses, the number of masses matching between sample and database protein, the size of the sequence database, and the kind and number of modifications considered. Using these parameters, we derive a simple statistical estimation that can be used to calculate the probability of true-positive protein identification.  相似文献   

7.
A variety of protein isolation and purification techniques for ribonucleoprotein (RNP) complexes were investigated for their compatibility with downstream analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Ribosomal proteins from Escherichia coli 70S ribosomes were obtained using methods such as phenol extraction and precipitation by organic solvents or acids. Under optimal conditions, more than 90% of the expected ribosomal proteins were detected in a single MALDI-MS experiment. The most effective approach combined ribosome denaturation by buffer exchange with acid precipitation of the ribosomal ribonucleic acids. An improved acid precipitation approach, involving the sequential additions of acetic and trifluoroacetic acid, yielded more complete protein coverage while minimizing loss of ion signal from lower molecular weight proteins. With phenol extraction, substantial gains in ion abundance of higher molecular weight proteins are noted, although some of the lower molecular weight proteins were not efficiently extracted. These results illustrate several effective approaches for protein isolation from protein complexes such as RNPs that are MALDI-MS compatible, and these approaches should extend the use of MALDI-MS for proteomics-based analyses of other protein-nucleic acid complexes.  相似文献   

8.
Ultraviolet matrix-assisted laser desorption/ionization mass spectrometric (UV-MALDI-MS) analysis of highly acidic, thermally labile species such as glycosaminoglycan-derived oligosaccharides is complicated by their poor ionization efficiency and tendency to fragment through the loss of sulfo groups. We have utilized a systematic approach to evaluate the effect of alkali metal counterions on the degree of fragmentation through SO3 loss from a highly sulfated model compound, sucrose octasulfate (SOS). The lithium, sodium, potassium, rubidium, and cesium salts of SOS were analyzed by UV-MALDI-time-of-flight (TOF)MS using an ionic liquid matrix, bis-1,1,3,3-tetramethylguanidinium alpha-cyano-4-hydroxycinnamate. The positive-ion and negative-ion MALDI mass spectra of five alkali metal salts of SOS were compared in terms of the degree of analyte fragmentation through the SO3 loss and the absolute intensity of a molecular ion signal. Experimental results demonstrate that the lithium, sodium, and potassium salts of SOS undergo some degree of fragmentation through the loss of SO3, whereas the fragmentation through the loss of SO3 in the rubidium and cesium salts of SOS is suppressed. A high detection sensitivity associated with the stability of sulfate half-esters was achieved for the cesium salt of SOS using positive-ion detection. Finally, the cesium salt of chondroitin sulfate A disaccharide was successfully analyzed using UV-MALDI-TOFMS.  相似文献   

9.
It has become necessary to assess the authenticity of beef origin because of concerns regarding human health hazards. In this study, we used a metabolomic approach involving matrix-assisted laser desorption/ionization imaging mass spectrometry to assess the authenticity of beef origin. Highly accurate data were obtained for samples of extracted lipids from beef of different origin; the samples were grouped according to their origin. The analysis of extracted lipids in this study ended within 10 min, suggesting this approach can be used as a simple authenticity assessment before a definitive identification by isotope analysis.  相似文献   

10.
Peptide Mass Fingerprinting (PMF) is still of significant interest in proteomics because it allows a large number of complex samples to be rapidly screened and characterized. The main part of post-translational modifications is generally preserved. In some specific cases, PMF suffers from ambiguous or unsuccessful identification. In order to improve its reliability, a combined approach using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICRMS) was evaluated. The study was carried out on bovine serum albumin (BSA) digest. The influence of several important parameters (the matrix, the sample preparation method, the amount of the analyte) on the MOWSE score and the protein sequence coverage were evaluated to allow the identification of specific effects. A careful investigation of the sequence coverage obtained by each kind of experiment ensured the detection of specific peptides for each experimental condition. Results highlighted that DHB-FTICRMS and DHB- or CHCA-TOFMS are the most suited combinations of experimental conditions to achieve PMF analysis. The association (convolution) of the data obtained by each of these techniques ensured a significant increase in the MOWSE score and the protein sequence coverage.  相似文献   

11.
A series of seven typical matrix-assisted laser desorption/ionization (MALDI) matrices has been investigated by means of electron capture negative ion mass spectrometry (ECNI-MS). It has been shown that the most effective matrices form deprotonated negative ions predominantly in the low-energy region. Relative dissociative cross sections have been measured for all molecules under investigation. The relative integrated abundance of [M - H](-) ion formation in the series changes by four orders of magnitude. It has been shown that 2,5-DHB (gentisic acid), one of the most effective MALDI matrices, has maximal relative intensity of [M - H](-) formation at the energy approximately equal 0.8 eV. This result is in accordance with a finding of Frankevich and Zenobi [Book of Abstracts, Workshop-school "Mass spectrometry in chemical physics, bio-physics and environmental sciences", Zvenigorod, Russia, April, 25-26, 2002, p. 40] that a probable origin of negative ions in MALDI is the process of low-energy (0.5-1 eV) dissociative electron capture by matrix molecules.  相似文献   

12.
Permethylated, peracetylated and perbenzoylated derivatives of glycosphingolipids (GSLs) were prepared to compare their liquid secondary ionization mass spectrometric (LSIMS) and collision-induced dissociation tandem mass spectrometric (CID/MS/MS) fragmentation patterns and also to determine sensitivity improvement in LSIMS and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) relative to the native species. Permethylation was carried out in the liquid phase, whereas peracetylation and perbenzoylation could be effected using either liquid (bulk)-phase or gas-phase procedures. Lower amounts of starting material were required for the gas-phase derivatization (? 100 pmol) compared with the bulk phase (?1 nmol), because the former method permits more efficient sample handling. All three types of derivatives yielded sensitivity improvements of at least two orders of magnitude over the native species in both LSIMS and MALDI-TOFMS. The behavior of the permethylated compounds was used as the benchmark for GSL structural information content in normal and tandem mass spectra. Fragments present in spectra of the three types of derivatives generated complementary information. Permethylated GSLs favored the formation of ions related to the ceramide moieties, whereas peracetylation enhanced the production of carbohydrate-related ions. The LSI mass spectra of perbenzoylated GSLs contained information on both ceramide and sugar portions of the molecules. Each of the LSIMS, MS/MS and MALDI-TOFMS techniques proved to be complementary to the others in this study; the use of all three is recommended for the generation of complete structural information.  相似文献   

13.
Potential difficulties associated with background silver salt clusters during matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of nonpolar polymers are reported. Silver salt cluster ions were observed from m/z 1500 to 7000 when acidic, polar matrices, such as 2,5-dihydroxybenzoic acid (DHB), all-trans-retinoic acid (RTA) or 2-(4-hydroxyphenylazo)benzoic acid (HABA), were used for the analysis of nonpolar polymers. These background signals could be greatly reduced or eliminated by the use of nonpolar matrices such as anthracene or pyrene. Representative examples of these background interferences are demonstrated during the analysis of low molecular weight nonpolar polymers including polybutadiene and polystyrene. Nonpolar polymers analyzed with acidic, polar matrices (e.g., RTA) and silver cationization reagents can yield lower quality mass spectral results when interferences due to silver clusters are present. Replacing the polar matrices with nonpolar matrices or the silver salts with copper salts substantially improved the quality of the analytical results. In addition, it was found that silver contamination cannot be completely removed from standard stainless steel sample plates, although the presence of silver contamination was greatly reduced after thorough cleaning of the sample plate with aluminum oxide grit. Carry-over silver may cationize polymer samples and complicate the interpretation of data obtained using nonpolar matrices in the absence of added cationization reagents.  相似文献   

14.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging is a technique that provides the ability to identify and characterize endogenous and exogenous compounds spatially within tissue with relatively little sample preparation. While it is a proven methodology for qualitative analysis, little has been reported for its utility in quantitative measurements. In the current work, inherent challenges in MALDI quantification are addressed. Signal response is monitored over successive analyses of a single tissue section to minimize error due to variability in the laser, matrix application, and sample inhomogeneity. Methods for the application of an internal standard to tissue sections are evaluated and used to quantify endogenous lipids in nerve tissue. A precision of 5% or less standard error was achieved, illustrating that MALDI imaging offers a reliable means of in situ quantification for microgram-sized samples and requires minimal sample preparation.  相似文献   

15.
Acquisition of tandem mass spectra from peptides or other analytes deposited on non-conductive membranes is inhibited on instruments combining matrix-assisted laser desorption/ionization with tandem time-of-flight analyzers (MALDI-TOF/TOF) due to a charging effect. A thin layer of gold renders the membrane conductive. This allows adequate data acquisition on MALDI-TOF/TOF systems. Therefore, this methodology extends the capacity of the molecular scanner concept to tandem mass spectrometry.  相似文献   

16.
The fragmentation behavior of six tetracyclic 2,3-dihydro-1,5-benzothiazepine derivatives cationized with protons and silver ions under post-source decay (PSD) matrix-assisted laser desorption/ionization (MALDI) conditions is reported. The protonated adduct ions decompose into several structurally important fragment ions, including substituted cyclopropane and benzohydrothiazole cations. Elimination of Ag and H and/or AgH from the silver-cationized adduct ions of these ([M+Ag](+)) compounds was observed. It was also found that [M+Ag](+) produced silver-depleted fragment ions exclusively. Based on the PSD results a fragmentation pathway is proposed for the [M+H](+) and [M+Ag](+) precursor ions.  相似文献   

17.
18.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   

19.
In those cases where the information obtained by peptide mass fingerprinting or matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) is not sufficient for unambiguous protein identification, nano-electrospray ionization (nano-ESI) and/or electrospray ionization tandem mass spectrometry (ESI-MS/MS) analysis must be performed. The sensitivity of nano-ESI/MS, however, is lower than that of MALDI-MS, especially at very low analyte concentrations and/or in the presence of contaminants, such as salt and detergents. Moreover, to perform ESI-MS/MS, the peptide masses of the precursor ions must be known. The approach described in this paper, MALDI-directed nano-ESI-MS/MS, makes use of information obtained from the more sensitive MALDI-MS experiments in order to direct subsequent nano-ESI-MS/MS experiments. Peptide molecular ions found in the MALDI-MS analysis are then selected, as their (+2) precursor ions, for nano-ESI-MS/MS sequencing, even though these ions cannot be detected in the ESI-MS spectra. This method, originally proposed by Tempst et al. (Anal. Chem. 2000, 72: 777-790), has been extended to provide better sensitivity and shorter analysis times; also, a comparison with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been performed. These experiments, performed using quadrupole time-of-flight instruments equipped with commercially available nano-ESI sources, have allowed the unambiguous identification of in-gel digested proteins at levels below their ESI-MS detection limits, even in the presence of salts and detergents.  相似文献   

20.
Salts with low melting points, also termed room-temperature ionic liquids, can be used as matrices in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF). They have great vacuum stability, and can dissolve polar and apolar solutes including carbohydrates, biological oligomers and proteins. The ionic liquids give much more homogeneous sample solutions compared with solid matrices. We demonstrate the usefulness of using ionic matrices to determine the molecular weight of DNA oligomers by direct TOF mass spectrometric analysis. Three oligonucleotides were tested, (d(pT)(10), d(pC)(11), and d(pC)(12)), with several ionic matrices synthesized from different bases associated to two acids (3-hydroxypicolinic acid and 2,5-dihydroxybenzoic acid). The results obtained show that the best ionic matrices enhance the ion peak intensity of the oligonucleotides with respect to conventional molecular matrices under our experimental conditions. In one case, an ionic matrix provided a signal-to-noise ratio ten times higher than the corresponding molecular matrix. Several of the tested ionic matrices were liquids. However, all working ionic matrices were solids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号