首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A method for mercury analysis and speciation in drinking water was developed, which involved stir bar sorptive extraction (SBSE) with in situ propyl derivatization and thermal desorption (TD)-GC-MS. Ten millilitre of tap water or bottled water was used. After a stir bar, pH adjustment agent and derivatization reagent were added, SBSE was performed. Then, the stir bar was subjected to TD-GC-MS. The detection limits were 0.01 ng mL(-1) (ethylmercury; EtHg), 0.02 ng mL(-1) (methylmercury; MeHg), and 0.2 ng mL(-1) (Hg(II) and diethylmercury (DiEtHg)). The method showed good linearity and correlation coefficients. The average recoveries of mercury species (n=5) in water samples spiked with 0.5, 2.0, and 6.0 ng mL(-1) mercury species were 93.1-131.1% (RSD<11.5%), 90.1-106.4% (RSD<7.8%), and 94.2-109.6% (RSD<8.8%), respectively. The method enables the precise determination of standards and can be applied to the determination of mercury species in water samples.  相似文献   

2.
A method for the determination of stale-flavor carbonyl compounds including E-2-octenal, E-2-nonenal, E,Z-2,6-nonadienal and E,E-2,4-decadienal in beer was developed using stir bar sorptive extraction (SBSE) with in-situ derivatization followed by thermal desorption-GC-MS analysis. The derivatization conditions with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine and the SBSE conditions--sampling mode, salt addition, sample volume, polydimethylsiloxane volume (sample/polydimethylsiloxane phase ratio) and extraction time--were examined. The method showed good linearity over the concentration range from 0.1 to 10 ng ml(-1) for all analytes and the correlation coefficients were higher than 0.9993. The limits of detection ranged from 0.021 to 0.032 ng ml(-1) for all analytes. The recoveries (98-101%) and precision (RSD 2.4-7.3%) of the method were examined by analyzing beer samples fortified at the 0.5-ng ml(-1) level. The method was successfully applied to low-level concentration samples.  相似文献   

3.
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively.  相似文献   

4.
A method for the determination of seven alkylphenols and bisphenol A by stir bar sorptive extraction (SBSE) with in situ derivatization-thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) is described. SBSE was performed with in situ acetylation and without derivatization for comparison. For 4-tert-butylphenol and bisphenol A, in situ acetylation improved the responses in SBSE-TD-GC-MS. The method detection limits ranged from 0.1 to 3.2 ng/l. The recoveries of the analytes from a river water sample spiked with standards at 10 and 100 ng/l were 85.3-105.9% (R.S.D., 3.0-11.0%) and 88.3-105.8% (R.S.D., 1.6-8.3%), respectively.  相似文献   

5.
A simple and highly sensitive method called stir bar sorptive extraction (SBSE) and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 5-chloro-2-(2,4-dichlorophenoxy)phenol (triclosan) in river water samples, is described. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 10mL water sample and stirring is carried out for 120min at room temperature (25 degrees C) in a vial. Then, the PDMS stir bar is subjected to TD-GC-MS. The detection limit of triclosan is 5ngL(-1) (ppt). The method shows linearity over the calibration range (0.02-20mugL(-1)) and the correlation coefficient is higher than 0.997 for triclosan standard solution. The recovery of triclosan in river water samples ranges from 91.9 to 108.3% (RSD: 4.0-7.0%). This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of triclosan in river water samples.  相似文献   

6.
A method for the trace analysis of methylmercury (MeHg) and Hg(II) in water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ alkylation with sodium tetraethylborate and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS). The limits of quantification of MeHg and Hg(II) are 20 and 10 ng L−1 (Hg), respectively. The method shows good linearity and the correlation coefficients are higher than 0.999. The average recoveries of MeHg and Hg(II) in tap or river water sample are 102.1-104.3% (R.S.D.: 7.0-8.9%) and 105.3-106.2% (R.S.D.: 7.4-8.5%), respectively. This simple, accurate, sensitive, and selective analytical method may be used in the determination of trace amounts of MeHg and Hg(II) in tap and river water samples.  相似文献   

7.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

8.
This study describes the development of a new method for determining p-hydroxybenzoic esters (parabens) in house dust. This optimised method was based on the pressurised hot water extraction (PHWE) of house dust, followed by the acetylation of the extracted parabens, stir bar sorptive extraction (SBSE) with a polydimethylsiloxane stir bar, and finally analysis using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). The combination of SBSE and PHWE allows the analytes to be preconcentrated and extracted from the aqueous extract in a single step with minimal manipulation of the sample. Furthermore the in situ acetylation of parabens prior to SBSE improved their extraction efficiency and their GC-MS signal. The method showed recoveries of between 40 and 80%, good linearity, repeatability and reproducibility (<10% RSD, at 100 ng g(-1), n=5), low limits of detection (from 1.0 ng g(-1) for propyl paraben to 2.1 ng g(-1) for methyl paraben) and quantification (from 3.3 ng g(-1) for propyl paraben to 8.5 ng g(-1) for methyl paraben). The proposed method was applied to the analysis of house dust samples. All the target parabens were found in the samples. Methyl and propyl parabens were the most abundant, with concentrations up to 2440 ng g(-1) and 910 ng g(-1), respectively. The high levels of parabens found in the samples confirm the importance of determining organic contaminants in indoor environments.  相似文献   

9.
This study presents the development of an analytical method for determining 9 synthetic musks in water matrices. The developed method is based on stir bar sorptive extraction (SBSE), coated with polydimethylsiloxane, and coupled with a thermal desorption–gas chromatography–mass spectrometry system (TD–GC–MS). SBSE can efficiently trap and desorb the analytes providing low limits of detection (between 0.02 ng L−1 and 0.3 ng L−1). Method validation showed good linearity, repeatability and reproducibility for all compounds. Furthermore, the limited manipulation of the sample required in this method implies a significant decrease of the risk of external contamination of the samples. The performance of the method in real samples was evaluated by analysing biological wastewater treatment plant (WWTP) influent and effluent samples, reverse osmosis treatment plant effluents and river waters. The most abundant musk was galaxolide with values up to 2069 ng L−1 and 1432 ng L−1 in the influent and effluent of urban WWTP samples, respectively. Cashmeran, Pantolide and Tonalide were also detected in all the matrices with values up to 94 ng L−1, 26 ng L−1 and 88 ng L−1, respectively. Although in Europe the use of nitromusks in cosmetics is prohibited, musk xylene and musk ketone were detected both in the WWTP and in the river samples. As far as we know, this is the first time than a SBSE method coupled with TD is applied for the determination of synthetic musks in water samples.  相似文献   

10.
冯利  张胜军  朱国华  李沐霏  刘劲松 《色谱》2017,35(4):466-471
基于搅拌棒吸附萃取(SBSE)技术建立了气相色谱-质谱测定地表水中16种多环芳烃(PAHs)的分析方法。该法采用多搅拌吸附棒同时富集,依次热脱附冷聚焦后进样的方式有效解决了搅拌棒吸附时间长、富集水样体积小等问题。优化后的结果表明,在0.2~10 ng/L范围内(萘为0.5~10 ng/L范围),16种PAHs的线性关系良好,相关系数(r)均0.99,方法检出限(MDL)为0.03~0.20 ng/L(萘为0.50 ng/L)。用该方法对钱塘江流域地表水进行测定,共检测出11种PAHs,含量为0.13~1.57 ng/L,不同添加水平下的加标回收率为75.6%~108.9%。该法可应用于地表水样品中该类物质的超痕量检测。  相似文献   

11.
A simple and inexpensive method for sorptive extraction of phenols from water samples is presented. A polydimethyl siloxane (PDMS) stir bar (Twister) is used as an extraction medium for derivatized phenols, which is thermally desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). Its performance was illustrated and evaluated for the enrichment of microg l(-1) to ng l(-1) of phenol and selected chlorophenols in water samples. The method showed good linearity, recoveries and blank levels, as well as advantages such as sensitivity, simplicity, low cost and high feasibility, being successfully applied for the analysis of phenolic compounds in natural water samples.  相似文献   

12.
This study focuses on a method for simultaneously determining personal care products in a wide range of polarities in different water matrices. The method is based on stir‐bar sorptive extraction followed by thermal desorption‐gas chromatography‐mass spectrometry. Prior to extraction, the parabens were acetylated to improve their affinity for the polydimethylsiloxane phase of the stir bar. The method showed good linearity, repeatability and reproducibility between days for all compounds and limits of detection at low ng/L levels (between 0.02 and 0.3 ng/L). The proposed method is also environmentally friendly, because it does not use organic solvents, and reduces the risk of external pollution, due to the minimal manipulation of the sample required. The method developed was successfully applied for the analysis of personal care products in different kinds of water matrices: influents and effluents of urban and industrial wastewater treatment plants, effluents of a reverse osmosis treatment plant and river waters. The influents of urban treatment plants generally showed the highest values for synthetic musks, with concentrations of up to 2219 ng/L of galaxolide, whereas the highest concentrations of parabens were detected in the industrial treatment plants influents.  相似文献   

13.
A simple and highly sensitive method called thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of 4-nonylphenol (NP) and 4-tert.-octylphenol (OP) in water samples, is described. NP and OP in samples are extracted from water samples and concentrated by the stir bar sorptive extraction (SBSE) technique. A stir bar coated with polydimethylsiloxane (PDMS) is added to a 2.0 ml water sample and stirring is carried out for 60 min at room temperature (25 °C) in a headspace vial. Then the extract is high sensitively analyzed by TD-GC-MS without any derivatization step. The optimum SBSE conditions are realized at an extraction time of 60 min. The detection limits are 0.02 ng ml−1 for NP and 0.002 ng ml−1 for OP. The method shows good linearity over the concentration range of 0.1-10 ng ml−1 for NP and 0.01-10 ng ml−1 for OP, and the correlation coefficients are higher than 0.999. The average recoveries of NP and OP are higher than 97% (R.S.D.: 3.6-6.2%) with correction using the added surrogate standards, 4-(1-methyl) octylphenol-d5 and deuterium 4-tert.-octylphenol. This simple, accurate, sensitive and selective analytical method may be used in the determination of trace amounts of NP and OP in tap and river water samples.  相似文献   

14.
Stir bar sorptive extraction (SBSE) in combination with thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) was applied for the determination of 9 UV filters in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 20 mL of water sample at pH 2 (10% MeOH) and stirred at 1000 rpm for 180 min. Then, the stir bar was subjected to TD-GC-MS. The desorption conditions (desorption temperature and desorption time) and SBSE parameters (ionic strength, pH, presence of organic solvent and time) were optimised using a full factorial design and a Box-Behnken design, respectively. The method shows good linearity (correlation coefficients >0.994) and reproducibility (RSD<16%). The extraction efficiencies were above 63% for all the compounds. Detection limits were between 0.2 and 63 ng/L. The developed method offers the ability to detect several UV filters at ultra-low concentration levels with only 20 mL of sample volume. The effectiveness of the method was tested by analysing real samples such as lake water, river water and treated wastewater. The application of the method allowed reporting the levels of UV filters in environmental water samples.  相似文献   

15.
A multiresidue method for the determination of 35 organic micropollutants (pesticides and polycyclic aromatic hydrocarbons) in water has been optimised using stir bar sorptive extraction (SBSE) and thermal desorption coupled to capillary gas chromatography-mass spectrometry (GC-MS). In the present work, the different parameters affecting the extraction of the analytes from the water samples to the PDMS-coated stir bars and optimisation of conditions affecting thermal desorption are investigated. The optimised conditions consist of a 100-ml water sample with 20% NaCl addition extracted with 20 mm length x 0.5 mm film thickness stir bars at 900 rpm during 14 h at ambient temperature. Desorption is carried out at 280 degrees C during 6 min under a helium flow of 75 ml/min in the splitless mode while maintaining a cryofocusing temperature of 20 degrees C in the programmed-temperature vaporisation (PTV) injector of the GC-MS system. Finally, the PTV injector is ramped to a temperature of 280 degrees C and the analytes are separated in the GC and detected by MS using full scan mode (m/z 60-400). Under the described conditions, the good repeatability, high analyte recoveries and robustness, make SBSE a powerful tool for routine quality control analysis of the selected semivolatile compounds in water samples.  相似文献   

16.
The analysis of organic pollutants in environmental water samples requires a pre-concentration step. Pre-concentration techniques such as stir bar sorptive extraction (SBSE) have gained popularity since they minimise the use of toxic organic solvents and can be considered as green analytical techniques. Similar to other pre-concentration techniques, one of the problems when SBSE is used is the matrix effect, which often occurs during the analysis of environmental water samples such as estuarine or wastewater samples. The present work studied the matrix effect during SBSE coupled to in-tube derivatisation–thermal desorption (TD)–gas chromatography–mass spectrometry for the determination of several endocrine disruptor compounds, such as alkylphenols, bisphenol A, estrogens and sterols, in environmental water samples, after optimisation of the major variables affecting the determination. Variables such as the addition of methanol or an inert salt to the donor phase, the extraction temperature, the volume of the donor phase, the stirring rate and the extraction time were studied during the SBSE optimisation. In the case of the in-tube derivatisation and TD step, the volume of the derivatisation reagent (N,O-bis(trimethylsilyl)triufloroacetamide with 1% of trimethylchlorosilane (BSTFA + 1% TMCS)) and the cryo-focusing temperature were fixed (2 μL and −50 °C, respectively) according to a consensus between maximum signal and optimal operation conditions. Good apparent recovery values (78–124%) were obtained for most of the analytes in Milli-Q water, except for 4-tert-octylphenol (4-tOP), which showed apparent recovery values exceeding 100%. Precision (n = 4) was in the 2–27%, and method detection limits were in the low nanogrammes per litre level for most of the analytes studied. The matrix effect was studied using two different approaches. On the one hand, Milli-Q water samples were spiked with humic acids, and apparent recovery values were studied with and without correction with the corresponding deuterated analogue. On the other hand, estuarine water and wastewater samples were spiked with known concentrations of target analytes, and apparent recoveries were studied as explained above. In general, the matrix effect could be corrected with the use of deuterated analogues, except for 4-tOP and nonylphenols for which [2H4]-n-nonylphenol did not provide good corrections.  相似文献   

17.
Stir bar sorptive extraction (SBSE) and thermal desorption followed by capillary gas chromatography coupled to mass spectrometry (SBSE-TD-GC-MS) was applied to the simultaneous determination of ultra-traces of 16 polycyclic aromatic hydrocarbons (PAHs), 12 polychlorinated biphenyls (PCBs), 6 phthalate esters (PEs) and 3 nonylphenols (NPs) in water samples. The parameters that could affect the sorption-desorption efficiency were studied. A Plackett-Burman design was used for the screening of the main effects of the experimental parameters related to the desorption step (desorption time, desorption temperature, desorption flow, cryo-focusing temperature and vent pressure). Afterwards, two central composite designs were used to find the optimal process settings for the extraction and desorption steps. The best analytical compromise conditions for the simultaneous determination of analytes from spiked water samples were found to be: sample volume (20 mL), sodium chloride addition (30%), methanol addition (20%), desorption time (10 min), desorption temperature (300 degrees C), desorption flow (23 mL min(-1)), cryo-focusing temperature (-50 degrees C) and vent pressure (7 psi). Remarkable recovery, repeatability and reproducibility were attained. Furthermore, excellent linearities (r(2) = 0.959-0.999) and low detection limits (0.1-10 ng L(-1)) were also achieved for the congeners studied. The proposed methodology was applied for the simultaneous determination of PAHs, PCBs, PEs and NPs in sea and estuarine waters. The influence of humic acids on the recovery was also studied.  相似文献   

18.
A fast method for detection of tuberculostearic acid (TBSA) in sputum samples is described. The samples, obtained from patients with known or suspected pulmonary tuberculosis, were decontaminated and concentrated before being analyzed by stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry (SBSE-TD-GC-MS). Prior to extraction, the mycobacterial lipids were hydrolyzed and then derivatized with ethyl chloroformate to increase the sorption of the compounds by the polydimethylsiloxane (PDMS) stir bar coating. The limit of detection (LOD) is 0.2 ng ml(-1). Four sputum samples that were classified by direct microscopy as smear-positive or negative were analyzed by GC-MS. TBSA was detected at concentrations ranging from 0.47 to 2.3 ng ml(-1). The method is sufficiently sensitive to detect TBSA directly in clinical samples without the need to culture the organisms.  相似文献   

19.
This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL−1, when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement of fluoxetine in typical and trace concentration levels.  相似文献   

20.
In this work, making use of experimental designs, headspace-stir bar sorptive extraction (HS-SBSE) followed by thermal desorption (TD) coupled to a gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of mercury and tin organometallic compounds present in surface water, sediment and biological tissue was optimized. All solid samples require a previous extraction typically done with diluted HCl or KOH/methanol solutions, and the derivatization, in all the cases, of the organometallic compounds with NaBEt(4). As a consequence, the preconcentration step was carried out in a 0.1 mol L(-1) HOAc/NaOAc buffer solution, with 0.1% (m/v) of NaBEt(4), without the addition of NaCl as a salting out reagent, and with the stir bar (20 mm x 1 mm) located in the headspace (HS). In addition, the desorption step required the following conditions: 250 degrees C (desorption temperature), 15 min (desorption time), 14.1 psi (approximately 97.2 kPa) (vent pressure) and 75 mL min(-1) (vent flow). Finally, to assure the extraction of all the analytes under equilibrium, 5h are required. Inorganic mercury (Hg(2+)) and tripropyltin (TPrT) were used as internal standards to correct for variations in the extraction, derivatization and detection steps. The resulting method provides precise (4-17%) and accurate (against four certified reference materials) results in the ng L(-1) and pg g(-1) range concentrations with recoveries within 80-120% for water samples. The proposed methodology is currently applied in the speciation analysis of specimens obtained in different estuarine sites of the Basque Coast.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号