首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 14 毫秒
1.
Takeuchi T  Lim LW 《Analytical sciences》2011,27(10):1019-1023
Inorganic anions were separated on a reversed-phase stationary phase dynamically modified with crown ether as a selector in capillary ion chromatography. The eluent contained crown ether, acetonitrile and a salt. Free and cation-trapped crown ether molecules in the eluent were adsorbed on a hydrophobic stationary phase such as triacontyl-functionalized silica (C30). The eluent cations trapped on crown ether worked as the ion-exchange sites, where the eluent anions and the analyte anions were competing for electrostatic interaction. The sizes of crown ether and the salt cation affected the retention of analyte anions. The concentrations of acetonitrile and crown ether as well as the eluent anion also affected the retention of analyte anions. An aqueous solution containing 18-crown-6-ether, potassium salt and acetonitrile achieved larger retention for analyte anions. Effects of the eluent conditions on the retention of analyte anions were examined in detail.  相似文献   

2.
Abstract

The mechanism of retention in reversed-phase high performance liquid chromatography is affected by both solute-eluent interactions and the nature of the stationary phase. The hydrophobic expulsion of ionized solutes plays a major role in affecting solute behavior in the water-rich range of hydroorganic eluents. In the water-lean range of eluent composition, there is little hydrophobic expulsion, and specific interactions between the solute and surface can be observed. The nature of the surface affects the retention of a variety of ionized species, both large cations and anions. Octadecylsilane (ODS) bonded phases can exhibit two different binding sites: one exhibiting a weak interaction and the second a strong specific interaction with a solute. Styrenedivinylbenzene polymeric surfaces exhibit the potential for weak dispersion interactions, and in addition pi-bonding interactions with a solute. A variety of solutes have been injected in a water: methanol eluent system in order to assess solute-surface effects on reversed-phase supports.  相似文献   

3.
A vitamin U-bonded stationary phase was prepared and the retention behavior of inorganic anions was examined using ion chromatography. Inorganic anions were retained on the vitamin U-bonded stationary phase under acidic as well as neutral eluent conditions in the ion-exchange mode. The elution order of the examined anions under neutral eluent conditions was nearly the same as that observed in common ion exchange mode, while the elution order observed under acidic eluent conditions was completely different from that observed in common ion exchange mode. The retention of the analyte anions under the neutral eluent conditions was due to the sulfonium groups of the vitamin U, while protonated primary amino groups caused retention of the analyte anions with different selectivity under acidic conditions. The retention factor of the analyte anions increased with decreasing eluent concentration under both eluent conditions. The present system was applied to the determination of bromide and nitrate contained in seawater.  相似文献   

4.
A new zwitterionic stationary phase based on silica bonded with 1-alkyl-3-(propyl-3-sulfonate) imidazolium was synthesized and characterized in this paper. The materials have been confirmed and evaluated by elemental analysis, thermogravimetric analysis and X-ray photoelectron spectroscopy. Potassium and calcium were separated simultaneously with several common inorganic anions including an iodate, chloride, bromide, nitrate and iodide on the phase. The effects of the concentration, organic solvent and pH of the eluent on the separation of anions were studied. Operated in the anion-exchange mode, this new stationary phase shows considerable promise for the separation of anions. Bases, vitamins and three imidazolium ionic liquids with different alkyl chains are also separated successfully on this column. The stationary phase has multiple retention mechanisms, such as anion-exchange, electrostatic attraction and repulsion interactions, and hydrophobic interaction between the zwitterionic stationary phase and specimens.  相似文献   

5.
Abstract

Alkyl-modified silica (RSi) and polystyrenedivinylbenzene (PRP-1) stationary phases are compared for the chromatographic separation of inorganic analyte anions and cations using hydro-phobic ions of opposite charge as mobile phase additives. Tetra-alkylammonium salts were used for anion separations and alkyl sulfonate salts for cation separations. Two major equilibria influence the retention of analyte ions on PRP-1. These are: retention of the hydrophobic ion on PRP-1 and an ion exchange selectivity between the hydrophobic counterion and the analyte ion. When using RSi retention is also influenced by ion exchange at residual silanol groups, which act as weak cation exchange sites. Mobile and stationary phase variables that influence analyte retention are identified. Optimization of these provides favorable eluting conditions for the separation of inorganic ionic analytes. Of particular interest is the potential use of PRP-1 and RSi columns for the separation of inorganic cations; conditions for the separation of alkali metals and alkaline earths are discussed.  相似文献   

6.
Summary The elution behavior of alkali and earth alkaline cations has been studied on a newly synthesized weak cationexchanger (WCX). Applying this stationary phase isocratic separation of these cations is possible. The dependence of retention on competing ion concentration is described via a simple model. The influence of crown ethers as well as organic eluent additives on selectivity and peak efficiency is demonstrated. With optimized separation such cations can be determined with detection limits of about 0.5 ppm using a conductivity detector without ion suppression.  相似文献   

7.
Methyl-capped poly(ethylene oxide) moieties were chemically bonded to silica gel using an amine-reactive modification reagent and evaluated as the stationary phase for ion chromatography. In this work, primary amino groups of an aminopropylsilica packing material were reacted with methyl-PEO12-NHS ester (succinimidyl-{[N-methyl]-dodecaethyleneglycol} ester) in phosphate buffer (pH 7.0) at room temperature. The prepared poly(ethylene oxide)-bonded stationary was evaluated for the separation of inorganic anions, and the retention behavior of inorganic anions on the prepared stationary phase was examined. The elution order of the investigated anions was the same as that observed in common ion chromatography. Both cations and anions of the eluent affected the retention of the analyte anions. Ion exchange was involved for the retention of analyte anions, although the present stationary phase does not possess any discrete ion-exchange sites. The stationary phase was applied to the separation of trace anions contained in tap water and a rock salt.  相似文献   

8.
Previous models for the retention behaviour of carboxylic acids in ion-exclusion chromatography are applicable only when the degree of ionisation of the analyte is constant over the entire chromatographic peak. When solutions of sulfuric acid are used as eluents, this condition applies only when the eluent concentration is considerably higher than that of the analyte. Since it is common for dilute solutions of sulfuric acid to be used as eluents, a retention model which accounts for unbuffered eluents has been developed. This model also considers the effects on retention of hydrophobic adsorption of the undissociated and dissociated forms of the analyte onto the stationary phase substrate, as well as the effects of organic solvents added to the eluent. The derivation of this model is presented and it has been evaluated using a comprehensive set of retention data obtained using three different sulfonated stationary phases over a range of eluent conditions. The adsorption coefficients calculated from the model are in accordance with expected trends and showed that both the undissociated and dissociated forms of the analyte acids were retained by hydrophobic adsorption effects, although this adsorption was much stronger for the undissociated analytes.  相似文献   

9.
Inorganic anions were separated on hydrophobic stationary phases such as triacontyl-functionalized silica. Eluent conditions were examined in detail, and iodate, nitrate, iodide, and thiocyanate could be separated by using aqueous solutions. The effect of the eluent concentration on the retention of analyte anions was examined for a wide range of sodium sulfate concentrations of up to 1 M. The retention factor of hydrophobic anions decreased with increasing sodium sulfate concentration in the lower concentration region, while it increased with increasing sodium sulfate concentration in the higher concentration region. The addition of a small amount of an organic substance such as acetonitrile and tetraethylene glycol increased the retention of iodide and thiocyanate, while the addition of alcohols decreased their retention. Operating at lower temperature also increased the retention of analyte anions. It was expected that inorganic anions were retained on the stationary phase via hydrophobic interactions. The retention mechanism was discussed, considering the results obtained.  相似文献   

10.
Three n-octadecylphosphonic acid-modified magnesia-zirconia reversed stationary phases (C18PZM) are prepared via the strong Lewis base interactions between organophosphonate and magnesia-zirconia composite. And two of them are end-capped by using trimethylchlorosilane as end-capping agent in different procedures. Stability studies at extreme high pH conditions (pH 9-12) show that both the non-endcapped and endcapped columns are quite stable at pH 12 mobile phase. The reversed-phase liquid chromatographic behavior of three C18PZM stationary phases are comparatively investigated in detail using a variety of basic compounds as probes. The retention of basic compounds on the three phases is studied over a wide range of pHs. And the possible retention mechanisms of basic compounds on the three stationary phases are discussed. The results show that the basic solutes retain by a hydrophobic and cation-exchange interaction mixed mechanism on three stationary phases when they are operated in eluents at pH values near to the pKa of the Brönsted conjugate acid form of the analyte, suggesting that inherent zirconol groups on ZM are not expected to interact with bases via cation-exchange interaction at lower pH. Nonetheless, the non-endcapped phase differs markedly from the edncapped ones in retention and selectivity of basic solutes using eluents at pH 4.1, implying a complex retention mechanism at this pH. The cation-exchange sites under such conditions are more likely due to the adsorbed Lewis base anionic buffer constituents (acetate) on accessible ZM surface sites than the chemisorbed phosphonate. Although the three phases exhibit very similar chromatographic behavior with eluents at pH 10.1, and show in general satisfactory separation of basic compounds and alkaloids studied, the performance for a specific analyte, however, differs largely from column to column.  相似文献   

11.
A carboxybetaine-type zwitterionic stationary phase obtained by immobilizing Mitsubishi Reagent EF-700 (C(8)F(17)SO(2)NHC(3)H(6)N(+) (CH(3))(2)-C(2)H(4)-COO(-)) onto a reversed-phase column was used for chromatographic separation of ions. When aqueous electrolyte solutions having higher pH values (>8) were used as eluents, the model analyte ions (NO(2)(-), H(2)PO(4)(-), Cl(-), Br(-), NO(3)(-), ClO(3)(-), I(-) and SCN(-)) were co-eluted and appeared at the void volume of this HPLC system. However, when aqueous electrolyte solutions having lower pH values (<5.5) were used as eluents, these anions were well retained and separated. Furthermore, when acetate buffers (NaAc/HAc) were used as eluents, plots of log k' (k', retention factor) versus pH of eluents (at constant [NaAc+HAc]), and log k' versus log [NaAc+HAc] (at constant pH), were linear with negative slopes. Breakthrough curves for acid solutions obtained using conductivity detection showed that H(+) ions and their conjugate anions were both retained on the stationary phase and the degree of binding was found to be independent of the acid species used. The degree to which the eluent cation was bound onto the carboxylate functionality of the zwitterion was found to exert a major effect on the retention of analyte anions. A strongly bound cation, such as H(+), reduced electrostatic repulsion effects exerted by the carboxylate functionality on analyte anions, so that they could freely access the quaternary ammonium sites on the zwitterion. It is concluded based on these experimental results that both the charges on the zwitterionic stationary phase make meaningful contributions to the separation of the analyte ions.  相似文献   

12.
Summary Silica-bonded stationary phases were developed for the separation of nucleic acid constituents and their properties investigated with homologous oligoriboadenylic acids in electrostatic interaction chromatography and with alkylbenzenes in reversed-phase chromatography. Analysis of retention data confirmed the stratified molecular structure of the surface which consist of a layer of propyl chains anchoredvia siloxane bridges to the silica surface proper and of polar moieties attached to the hydrocarbonaceous functions. The polar top layer contains weak cationic and/or hydrophobic binding sites, is strongly hydrated in contact with aqueous eluents and bars the access by large biopolymers to the hydrocarbonaceous sublayer. In reversed-phase chromatography of small non polar molecules with hydro-organic eluents, however, this layer is accessible and engenders a retentive behavior typical for weak hydro-carbonaceous bonded phases. As a result the stationary phases, depending on the nature of the sample and the mobile phase, exhibit the properties of "soft" phases for the chromatography of biopolymers under mild elution conditions and those of "hard" phases for the separation of small non-polar molecules under conditions generally employed in reversed-phase chromatography. The retention of nucleic acid constituents on most of the stationary phases investigated subject to a dual mechanism as a result of the interplay of electrostatic and hydrophobic interactions between the eluites and the binding sites on the stationary phase surface. Siliceous stationary phases having surface morphology described above are suitable for the separation of nucleic acid constituents having widely ranging molecular weights up to 3 × 106 Daltons provided the support has appropriate pore dimensions. This is demonstrated by the separation of mixtures arising from digesting t-RNApha or polyadenylic acids as well as those of ribosomal RNA’s and different forms of the plasmid pBR322 DNA. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

13.
Guo H  Chu C  Li Y  Yang B  Liang X 《The Analyst》2011,136(24):5302-5307
Ion chromatography (IC) is one of the most powerful analysis technologies for the determination of charged compounds. A novel click lysine stationary phase was prepared via Cu(I) catalyzed alkyne-azide 1,3-dipolar cycloaddition (CuAAC) and applied to the analysis of inorganic ions. The chromatographic evaluation demonstrated good performance (e.g. the plate number of thiocyanate is ~50,000 plates m(-1)) and effective separation ability for the common inorganic anions with aqueous Na(2)SO(4) eluent. The separation mechanism was observed to be mainly dominated by ion exchange interaction. The retention of these analytes is highly dependent on the pH value of eluent. Compared with the lysine stationary phase prepared via the conventional manner, the click lysine exchanger demonstrated shorter retention time and better ion separation characteristics under the same chromatographic conditions, which is a great advantage for rapid separation and analysis of inorganic ions.  相似文献   

14.
Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness and polarity of the resin cation on selectivity. The type of resin matrix, the hydrophobic nature of the resin surface and the degree of solvation also affect chromatographic behavior. The selectivity series observed in ion chromatography seems to be best explained by the interplay of two components: electrostatic attraction (ES) and the enforced-pairing (EP) that is brought about by hydrophobic attraction and by water-enforced ion pairing. Selectivity in ion-pair chromatography (IPC) and in zwitterion ion chromatography (ZIC) is affected by both the mobile phase cation and anion. This leads to elution orders for anions that are different from conventional ion-exchange chromatography (IC) of anions where cations are excluded from the stationary phase and have little effect on a separation. The elution order of anions in ZIC is similar to that in IC except for small anions of 2-charge, which are retained more weakly in ZIC. A unique advantage of ZIC is that sample ions can be eluted as ion pairs with pure water as the eluent and a conductivity detector. The mechanism for separation of anions on a zwitterionic stationary phase has been a subject for considerable debate. The available facts point strongly to a partitioning mechanism or a mixed mechanism in which partitioning is dominant with a weaker ion-exchange component.  相似文献   

15.
The retention and separation selectivity of inorganic anions and on-column derivatised negatively charged citrate or oxalate metal complexes on reversed-phase stationary phases dynamically coated with N-(dodecyl-N,N-dimethylammonio)undecanoate (DDMAU) has been investigated. The retention mechanism for the metal-citrate complexes was predominantly anion exchange, although the amphoteric/zwitterionic nature of the stationary phase coating undoubtedly also contributed to the unusual separation selectivity shown. A mixture of 10 inorganic anions and metal cations was achieved using a 20 cm monolithic DDMAU modified column and a 1 mM citrate eluent, pH 4.0, flow rate equal to 0.8 mL/min. Selectivity was found to be strongly pH dependent, allowing additional scope for manipulation of solute retention, and thus application to complex samples. This is illustrated with the analysis of an acidic mine drainage sample with a range of inorganic anions and transition metal cations, varying significantly in their concentrations levels.  相似文献   

16.
The retention behavior of inorganic anions on a triazole-based stationary phase was first examined in ion chromatography. It was initially designed for hydrophilic interaction liquid chromatography and was simply prepared by introducing the triazole groups onto the surface of silica gel via click chemistry. Effective separation of common inorganic anions, including iodate, chloride, bromide, nitrate and iodide, was achieved with Na(2)SO(4) eluent. The logarithm of the retention factor of analytes was observed to be linear with the logarithm of the eluent concentration, and the slopes of the plots were almost the same as those of the ideal theoretical value. The eluent pH value in the range of 3.4-7.0 had little effect on the separation. The utility of the column was demonstrated for the determination of UV-absorbing anions in saliva and tap water.  相似文献   

17.
In ion chromatography, samples of very different ammonium-to-sodium concentration ratios are difficult to quantify since these two cations have similar selectivities for stationary phases containing commonly used sulfonate or carboxylate cation-exchange functional groups. The IonPac CS15 cation-exchange column, with carboxylate and phosphonate functional groups as well as a crown ether group, was developed to address this limitation. Selectivity for the common inorganic cations on this column is different from that of conventional cation-exchange columns in that the separation between sodium and ammonium ions has been greatly increased, allowing for determinations of low levels of one in the presence of high levels of the other with an isocratic eluent. For larger than 4000:1 sodium-to-ammonium concentration ratios, an eluent step change or gradient elution is needed. For moderate ratios, combinations of this column with a carboxylate column, containing no crown ether group, can be used at room temperature with an isocratic eluent containing no organic solvent.  相似文献   

18.
The unique ability of macrocyclic ligands, such as the crown ethers and cryptands, to selectively complex alkali metal cations can be used as the basis for chromatographic separations of anions. Specifically, macrocycles which are adsorbed onto a reversed-phase column, form positively charged anion-exchange sites when they combine with eluent cations. Previously we have demonstrated gradient anion separations based on changing the column capacity during the course of the separation by altering the eluent cation, temperature, or organic modifier content using cryptand-based columns. Herein we report that excellent separations can also be achieved using 18-crown-6 based columns. In this column, anion retention increases with increasing eluent strength and organic modifier content. This observation is in keeping with the relatively moderate affinity of crown ethers for alkali metals when compared to cryptands. The separation of anions achieved by optimizing mobile phase variables shows that isocratic separations of anions on the crown-based column are almost as good as separations achieved only under gradient conditions on cryptand-based columns. Cation gradients provide additional improvements on the separations using the crown-based column.  相似文献   

19.
The silica-based stationary phases with favorable physical characteristics are the most popular in liquid chromatography. However, there are several problems with silica-based materials: severe peak tailing in the chromatography of basic compounds, non-reproducibility for the same chemistry columns, and limited pH stability. Ionic liquids (ILs) as mobile phase components can reduce peak tailing by masking residual free silanol groups. The chromatographic behavior of some alkaloids from different classes was studied on C18, phenyl, and pentafluorophenyl columns with different kinds and concentrations of ionic liquids as additives to aqueous mobile phases. Ionic liquids with different alkyl substituents on different cations or with different counterions as eluent additives were investigated. The addition of ionic liquids has great effects on the separation of alkaloids: decrease in band tailing, increase in system efficiency, and improved resolution. The retention, separation selectivity, and sequence of alkaloid elution were different when using eluents containing various ILs. The increase of IL concentration caused an increase in silanol blocking, thus conducted to decrease the interaction between alkaloid cations and free silanol groups, and caused a decrease of alkaloids retention, improvement of peak symmetry, and increase of theoretical plate number in most cases. The effect of ILs on stationary phases with different properties was also examined. The different properties of stationary phases resulted in differences in analyte retention, separation selectivity, peak shape, and system efficiency. The best shape of peaks and the highest theoretical plate number for most investigated alkaloids in mobile phases containing IL was obtained on pentafluorophenyl (PFP) phase.  相似文献   

20.
Liu Y  Du Q  Yang B  Zhang F  Chu C  Liang X 《The Analyst》2012,137(7):1624-1628
A silica based amino stationary phase was prepared by immobilization of propargylamine on azide-silica via click chemistry. This readily prepared click amino stationary phase demonstrated good selectivity in separation of common inorganic anions under ion chromatography (IC) mode, and the triazole ring in combination with free amino group was observed to play a major role for separation of the anions examined. On the other hand, the stationary phase also showed good hydrophilic interaction liquid chromatography (HILIC) properties in the separation of polar compounds including nucleosides, organic acids and bases. The retention mechanism was found to match well the typical HILIC retention.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号