首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A minicolumn packed with poly(aminophosphonic acid) chelating resin incorporated in an on-line preconcentration system for flame atomic-absorption spectrometry was used to determine ultratrace amounts of lead in mussel samples at μg L–1 level. The preconcentrated lead was eluted with hydrochloric acid and injected directly into the nebulizer for atomization in an air-acetylene flame for measurement. The performance characteristics of the determination of lead were: preconcentration factor 26.8 for 1 min preconcentration time, detection limit (3σ) in the sample digest was 0.25 μg g–1 (dry weight) for a sample volume of 3.5 mL and 0.2 g sample (preconcentration time 1 min), precision (RSD) 2.3% for 25 μg L–1 and 2.0% for 50 μg L–1. The sampling frequency was 45 h–1. The method was highly tolerant of interferences, and the results obtained for the determination of lead in a reference material testify to the applicability of the proposed procedure to the determination of lead at ultratrace level in biological materials such as mussel samples. Received: 1 November 2000 / Revised: 8 January 2001/ Accepted: 11 January 2001  相似文献   

2.
In this work, flame atomic absorption spectrometry (FAAS) was used as a detector for the determination of zinc in natural water samples with a flow-injection system coupled to solid-phase extraction (SPE). In order to promote the on-line preconcentration of zinc from samples a minicolumn packed with 35 mg of a styrene-divinylbenzene resin functionalized with (S)-2-[hydroxy-bis(4-vinylphenyl)methyl]pyrrolidine-1-carboxylic acid ethyl esther was utilized. The system operation was based on Zn(II) ion retention at pH 9.5 +/- 0.5 in such a minicolumn with analyte elution, at the back flush mode, with 1 mol L(-1) HCl directly to the FAAS nebulizer. The influence of the chemical (sample pH, buffer concentration, HCl eluent concentration and effect of the ionic strength) and flow (sample and eluent flow rates and preconcentration time) parameters that could affect the performance of the system were investigated as well as the possible interferents. At the optimum conditions, for 2 min of preconcentration time (9.9 ml of sample volume), the developed methodology presented a detection limit of 1.1 microg L(-1), a RSD of 3.5% at 10 microg L(-1) and an analytical throughput of 24 h(-1). Whereas, for 4 min of the preconcentration time (19.8 ml of sample volume) a detection limit of 0.98 microg L(-1), a RSD of 6.5% at 5 microg L(-1) and a sampling frequency of 13 h(-1) are reported.  相似文献   

3.
A procedure for the determination of trace amount of cadmium after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been proposed. This chelate is adsorbed on the adsorbent in the pH range 3-8 from large volumes of aqueous solution of water samples with a preconcentration factor of 200. After being sorbed, cadmium was eluted by 5 mL of 2.0 mol L(-1) nitric acid solution and determined directly by flame atomic absorption spectrophotometery (FAAS). The detection limit (3sigma) of cadmium was 0.32 microg L(-1). The precision of the proposed procedure, calculated as the relative standard deviation of recovery in sample solution (100 mL) containing 5 microg of cadmium was satisfactory (1.9%). The adsorption of cadmium onto adsorbent can formally be described by a Langmuir equation with a maximum adsorption capacity of 19.6 mg g(-1) and a binding constant of 6.5 x 10(-3) L mg(-1). Various parameters, such as the effect of pH and the interference of a number of metal ions on the determination of cadmium, have been studied in detail to optimize the conditions for the preconcentration and determination of cadmium in water samples. This procedure was applied to the determination of cadmium in tap and river water samples.  相似文献   

4.
A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 microg L(-1), and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 microg L(-1), respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.  相似文献   

5.
Continuous ultrasound-assisted extraction has been coupled with preconcentration and flame atomic absorption spectrometry for the determination of cadmium and lead in mussel samples. Experimental designs were used for the optimisation of the leaching and preconcentration steps. The use of diluted nitric acid as extractant in the continuous mode at a flow rate of 3.5 ml min−1 and room temperature was sufficient for quantitative extraction of these trace metals. A minicolumn containing a chelating resin (Chelite P, with aminomethylphosphoric acid groups) was proved as an excellent material for the quantitative preconcentration of cadmium and lead prior to their flame atomic absorption detection. A flow injection manifold was used as interface for coupling the three analytical steps, which allowed the automation of the whole analytical process. A good precision of the whole procedure (2.0 and 2.3%), high enrichment factors (20.5 and 11.8) and a detection limit of 0.011 and 0.25 μg g−1 for cadmium and lead, respectively, were obtained for 80 mg of sample. The sample throughputs were ca. 16 and 14 samples h−1 for cadmium and lead, respectively. The accuracy of the analytical procedures was verified by using a standard reference material (BCR 278-R, mussel tissue) and the results were in good agreement with the certified values. The method was successfully applied to the determination of trace amounts of cadmium and lead in mussel samples from the coast of Galicia (NW, Spain).  相似文献   

6.
Bingol D  Kulcu M 《The Analyst》2011,136(19):4036-4044
A solid-phase extraction method was proposed for the preconcentration of Cu(II) in different samples in a mini-column packed with functionalized multi-walled carbon nanotubes (MWCNTs-COOH) as an effective sorbent, without using any complexing reagent, prior to its determination by flame atomic absorption spectrometry using response surface methodology. The experimental optimization step was performed by both a two-level full factorial design, with a center point, and a Box-Behnken design combined with response surface methodology. Three variables (pH, amount of Cu(II), and sample volume) were regarded as factors in the optimization. It was found that pH is the most significant factor affecting the preconcentration of Cu(II). The preconcentration factor was obtained as 100. The linear range was 1-5 mg L(-1) (R(2) = 0.999). Under the optimized experimental conditions, the detection limit (3s) of the proposed method followed by FAAS was found to be 0.27 μg L(-1). The relative standard deviation for 10 replicate measurements of 50 and 100 μg L(-1) Cu(II) was 2.39% and 0.98%, respectively. The response surface methodology was successfully applied to the determination of Cu(II) in water samples and mussel samples, and in a certified standard reference material (BCR-320R, Channel sediment).  相似文献   

7.
An on-line lead preconcentration and determination system implemented with inductively coupled plasma-atomic emission spectrometry (ICP-AES) with ultrasonic nebulization (USN) in association with flow injection was studied. For the preconcentration of lead, a Pb-quinolin-8-ol complex was formed on-line at pH 6.8 and retained on Amberlite XAD-16 resin. The lead was removed from the microcolumn by countercurrent elution with nitric acid. A total enhancement factor of 225 was obtained with respect to ICP-AES with pneumatic nebulization (15.0 for USN and 15.0 for the column). The detection limit for Pb for the preconcentration of a 10 mL wine sample was 0.15 microg/L. The precision for 10 replicate determinations at a Pb level of 25 microg/L was a relative standard deviation of 2.5%, calculated from the peak heights obtained. The calibration graph obtained by using the preconcentration system for lead was linear with a correlation coefficient of 0.9995 for levels near the detection limit up to > or = 1000 microg/L. The method was successfully applied to the determination of lead in wine samples.  相似文献   

8.
A new sensitive and low-cost method that combines continuous acid extraction, online preconcentration, and flame atomic absorption spectrometry for cadmium determination at microg levels in solid and semisolid milk products is described. A continuous ultrasound-assisted extraction system is used to carry out the dynamic acid extraction step. The acid extract is preconcentrated online on a minicolumn packed with a chelating resin (Chelite P, with aminomethylphosphoric acid groups), and the retained cadmium is eluted with hydrochloric acid and continuously monitored by flame atomic absorption spectrometry. An experimental design (Plackett-Burman 2-6*3/16) is used to optimize the continuous extraction and the preconcentration step. The method allowed a total sampling frequency of 28 samples/h. A good precision of the whole procedure (3.0% relative standard deviation) for a cheese sample containing 0.103 +/- 0.004 microg/g Cd (dry mass), a high enrichment factor (20.5), and detection and quantification limits of 0.014 and 0.067 microg/g, respectively, for a 60 mg of sample were obtained with this methodology. The method was successfully applied to the determination of trace amounts of cadmium in solid and semisolid milk products, such as cheese and yogurt samples.  相似文献   

9.
A rapid and sensitive method has been proposed for the sequential determination of chromium(III) and total chromium in water samples by flame atomic absorption spectrometry combined with a flow injection on-line preconcentration on a double-microcolumn. The chromium(III) and total chromium in samples were retained on a double-microcolumn with a cation exchange resin, respectively, and eluted directly into a nebulizer by 3 mol L(-1) HNO3. The characteristic concentration (gives a derivative absorbance of 0.0044) and the detection limit (3sigma) for chromium were 0.512 microg L(-1) and 0.647 microg L(-1) for a preconcentration time of 1 min, respectively. This is an improvement of 20 and 14-times than those of conventional FI-FAAS. The proposed method allows the determination of chromium in the range of 0-90 microg L(-1) with a relative standard deviation of 3.63% at the 10 microg L(-1) level. The method has been applied for the analysis of chromium in reference water of National Research Center for Certified Reference Materials (GBW08607) and other water samples with satisfactory results.  相似文献   

10.
Lima R  Leandro KC  Santelli RE 《Talanta》1996,43(6):977-983
A procedure for the preconcentration and determination of lead in vegetable and biological samples was developed in the continuous mode coupled to a flame atomic absorption spectrometer. Lead is quantitatively preconcentrated in acetic buffer as its diethyldithiocarbamate chelate onto a C-18 minicolumn, placed in the loop of a proportional injector, eluted by a stream of methyl isobutyl ketone and introduced directly into the nebuliser. A detection limit of 3 microg 1(-1) is obtained using a time-based technique for 2 min preconcentration and an RSD of 3.8% was readily achieved for three measurements of 25 microg Pb 1(-1). The sample throughput is 24 h(-1). Using preconcentration times of 10 min an enrichment factor of 189 can be obtained. The continuous flow system was used for some reference sample analysis and the obtained results reveal that the methodology can be easily applied for vegetable and biological sample analysis.  相似文献   

11.
A procedure was developed for the determination of lead (Pb) and manganese (Mn) using slurry sampling. The two elements were detected using flame atomic absorption spectrometry with a slotted tube atom trap. Slurries were prepared by adding nitric acid solution (0.30%, w/v) to a powdered sample (0.10 g). After homogenization by ultrasonic bath for 15 min, the slurries were introduced directly into the detection equipment. Some conditions of the procedure were evaluated, such as acid concentration, presence of surfactants, and sonication time. Under optimized conditions, the LODs and LOQs achieved were 0.8 and 2.6 microg/g for Pb and 0.5 and 1.6 microg/g for Mn, respectively. The precision obtained varied between 3.1 and 5.8% (Mn), and 2.6 and 5.4% (Pb) for slurries of shrimp and sediment. The analytical curves were established using aqueous standards in nitric acid solutions. The accuracy of the method was assessed through the determination of Pb and Mn in the following certified reference materials: ERM-CE 278 (mussel tissue), CRM 397 (human hair), and SRM 1646a (estuarine sediment). The proposed procedure was successfully applied to the determination of Pb and Mn in six samples of shrimp powder, seasoning, and river sediment. The levels of Mn detected varied from 2.2 to 71.3 microg/g; Pb was detected in only one sediment sample (4.3 microg/g).  相似文献   

12.
An on-line column preconcentration method based on the combined use of ammonium O,O-diethyldithiophosphate and activated carbon or polyurethane foam as adsorbents has been developed for the determination of Pb in water samples. The complexed Pb was eluted with ethanol and determined by flame atomic absorption spectrometry. The optimum preconcentration conditions are given for each adsorbent. The enrichment factors were 63 and 294, and the detection limits (3sigma) 3 microg L(-1) and 0.8 microg L(-1), respectively, for the carbon and foam systems. When the optimized procedures were applied to the determination of Pb in water samples the recovery efficiency was > 96%.  相似文献   

13.
A procedure for preconcentration and determination of lead in water is described. The method is based on the sorption of Pb(II) in a minicolumn packed with a functionalized sorbent and subsequent elution with acidic solution. The determination of lead content in the eluate was carried out using flame atomic absorption spectrometry. The sorbent was prepared by immobilization of the ligand 4-(5'-bromo-2'-thiazolylazo)orcinol on polystyrene-divinylbenzene through an azo spacer. Diazotization and coupling reactions were used for synthesis of the sorbent. Some variables affecting the preconcentration were optimized using a full factorial design. Under optimized conditions, the method presented a detection limit of 0.5 microg/L and enrichment factor of 36 for a sample volume of 25 mL. The accuracy of the method was tested by the determination of lead in a standard reference material (National Institute of Standards and Technology 1643d Fresh Water). The proposed procedure was applied to the determination of lead in samples of natural and drinking waters.  相似文献   

14.
An on-line cadmium preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) associated to flow injection (FI) with ultrasonic nebulization system (USN) was studied. The cadmium was retained as the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, Cd-(5-Br-PADAP), complex, at pH 9.5. The cadmium complex was removed from the knotted reactor (KR) with 3.0 mol/L nitric acid. A total enhancement factor of 216 was obtained with respect to ICP-OES using pneumatic nebulization (12 for USN and 18 for KR) with a preconcentration time of 60 s. The value of the detection limit for the preconcentration of 5 mL of sample solution was 5 ng/L. The precision for 10 replicate determinations at the 5 microg/L Cd level was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9998 at levels near the detection limits up to at least 1,000 microg/L. The method was successfully applied to the determination of cadmium in wine samples.  相似文献   

15.
This paper proposes a preconcentration procedure for determination of nickel in saline aqueous waste samples by flame atomic absorption spectrometry (FAAS). It is based on cloud-point extraction of nickel(II) ions as 2-(5-bromo-2-pyridylazo)-5-diethilaminophenol (Br-PADAP) complexes using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The optimisation step was performed using a four-variable Doehlert design, involving the factors centrifugation time (CT) of system after addition of surfactant, solution pH, methanol volume (MV) added at micellar phase, and buffer concentration (BC). The analytical response used was absorbance, after volume correction. Using the established experimental conditions in the optimisation step the procedure enables nickel determination with a detection limit (3 delta/ S) of 0.2 microg L(-1), quantification limit (10 delta/ S) of 0.7 microg L(-1), and precision, calculated as relative standard deviation ( RSD) of 4.7 ( n=8) and 3.5% ( n=8) for nickel concentration of 1 and 5 microg L(-1), respectively. The preconcentration factor, determined from the ratio of the slopes of the analytical curves with and without preconcentration, is 74. The recovery achieved for nickel determination in the presence of several cations demonstrated that this procedure could be applied for analysis of water samples. The robustness was checked by using saturated fractional factorial designs, centred on the established experimental conditions in the optimisation step. The results of these tests demonstrated that the variables centrifugation time and buffer concentration are robust for modification by 10% and that solution pH and methanol volume are robust for 5%. Accuracy was evaluated by using the certified material reference SLEW-3 estuarine water for trace metals. The procedure was used for determination of nickel in saline effluents from oil refinery samples. Recovery results (95-104%) indicate that the procedure has satisfactory accuracy for nickel determination in these samples.  相似文献   

16.
A novel method for cobalt preconcentration by cloud point extraction with on-line phase separation in a PTFE knotted reactor and further determination by electrothermal atomic absorption spectrometry (ETAAS) is proposed. The cloud point system was formed in the presence of non-ionic micelles of polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) and it was retained on the inner walls of a knotted reactor (KR). The surfactant rich-phase was removed from the knotted reactor with 75 microL of methanol acidified with 0.8 mol L(-1) nitric acid, directly into the dosing hole of the L'Vov graphite tube. An enrichment factor of 15 was obtained with a preconcentration time of 60 s, with respect to the direct determination of cobalt by ETAAS in aqueous solutions. The value of the detection limit for the preconcentration of 5 mL of sample solution was 10 ng L(-1). The precision, expressed as the relative standard deviation (R.S.D.), for 10 replicate determinations at 0.5 microg L(-1) Co level was 4.5%. Verification of the accuracy was carried out by analysis of a standard reference material (NIST SRM 1640e "Trace elements in natural water"). The method was successfully applied to the determination of cobalt in drinking water samples.  相似文献   

17.
An on-line cadmium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated with flow injection was studied. Cadmium was retained as Cd-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol Cd-(5-Br-PADAP) complex, pH 9.3. The Cd complex was removed from the knotted reactor (KR) with ethanol. A total enhancement factor of 140 was obtained with respect to FAAS (40 for KR and 3.5 due to the use of ethanol) with preconcentration time of 120 s. The detection limit value for preconcentration of 1 g sample was 0.5 ng/g. The repeatability for 10 replicate determinations at 5.0 ng/g Cd level was 3.5% relative standard deviation, calculated from peak heights obtained. The calibration graph using the preconcentration system for Cd was linear with a correlation coefficient of 0.9990 at levels near the detection limits to at least 2000 ng/g. The method was successfully applied to determination of total Cd in honey samples.  相似文献   

18.
An on-line dysprosium preconcentration and determination system based on the hyphenation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with ICP-OES was studied. For the preconcentration of dysprosium, a Dy(III)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex was formed on-line at pH 9.22 in the presence of nonionic micelles of PONPE-7.5. The micellar system containing the complex was thermostated at 30 degrees C in order to promote phase separation, and the surfactant-rich phase was retained in a microcolumn packed with cotton at pH 9.2. The surfactant-rich phase was eluted with 4 mol L(-1) nitric acid at a flow rate of 1.5 mL min(-1), directly in the nebulizer of the plasma. An enhancement factor of 50 was obtained for the preconcentration of 50 mL of sample solution. The detection limit value for the preconcentration of 50 mL of aqueous solution of Dy was 0.03 microg L(-1). The precision for 10 replicate determinations at the 2.0 microg L(-1)Dy level was 2.2% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for dysprosium was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 microg L(-1). The method was successfully applied to the determination of dysprosium in urine.  相似文献   

19.
An on-line solid-phase extraction (SPE) protocol using the cigarette filter as sorbent coupled with high-performance liquid chromatography (HPLC) was developed for simultaneous determination of trace naphthalene (NAPH), phenanthrene (PHEN), anthracene (ANT), fluoranthene (FLU), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), benzo(a)pyrene (BaP), and benzo(ghi)perylene (BghiP) in water samples. To on-line interface solid-phase extraction to HPLC, a preconcentration column packed with the cigarette filter was used to replace a conventional sample loop on the injector valve of the HPLC for on-line solid-phase extraction. The sample solution was loaded and the analytes were then preconcentrated onto the preconcentration column. The collected analytes were subsequently eluted with a mobile phase of methanol-water (95:5). HPLC with a photodiode array detector was used for their separation and detection. The detection limits (S/N = 3) for preconcentrating 42 mL of sample solution ranged from 0.9 to 58.6 ng L(-1) at a sample throughput of 2 samples h(-1). The enhancement factors were in the range of 409-1710. The developed method was applied to the determination of trace NAPH, PHEN, ANT, FLU, BbF, BkF, BaP and BghiP in local river water samples. The recoveries of PAHs spiked in real water samples ranged from 87 to 115%. The precisions for nine replicate measurements of a standard mixture (NAPH: 4.0 microg L(-1), PHEN: 0.40 microg L(-1), ANT: 0.40 microg L(-1), FLU: 2.0 microg L(-1), BbF: 1.6 microg L(-1), BkF: 2.0 microg L(-1), BaP: 2.0 microg L(-1), BghiP: 1.7 microg L(-1)) were in the range of 1.2-5.1%.  相似文献   

20.
A flow injection system with a pre-concentration minicolumn based on a chelating resin was coupled to a flame atomic absorption spectrometer. The focus of this work was the investigation of interference effects and the analytical applicability of the azo-immobilized 8-hydroxyquinoline on controlled-pore glass for the determination of Cr and Mn in mussel and non-fat milk powder. All studied concomitants affected the retention of Cr(III). These effects are probably related to the formation of hydroxo-complexes at the optimum pH range 9.0-10. The positive effect caused by Ca(II) was exploited to increase the retention of Cr(III) species and to improve the slope by 70%. The interferences on Mn(II) retention were less severe. The quantification of Cr and Mn was performed by standard additions. The proposed methodology was validated by analysis of three certified reference materials of mussels (Cr and Mn) and non-fat milk powder (Mn) with a mean relative percent error of <6.5% and mean relative standard deviation of <13%. Chromium and Mn were determined in typical Chilean mussels samples, and Mn was determined in non-fat milk powder samples. Results agreed at the 95% confidence level with those obtained by electrothermal atomic absorption spectrometry (ETAAS) using graphite furnace atomization. The method detection limits for a 30 s pre-concentration time were 0.9 and 1.1 micro g L(-1) for Mn, and 2.2 and 2.5 micro g L(-1) for Cr in acid digested solutions of mussel and non-fat milk, respectively. The methodology is simple, fast (sampling frequency 60-72 h(-1)), reliable, of low cost, and can be applied to the determination of traces of Cr (> or =0.18 micro g g(-1)) and Mn (> or =0.6 micro g g(-1)) in mussel samples, and Mn (> or =0.37 micro g g(-1)) in non-fat milk powder.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏