1.
A novel pressure-driven sample injection method was developed as an alternative to electrokinetic injection, and electrophoretic separation was carried out on a microfabricated device employing this method. This method enables a defined volume of liquid dispensing, followed by instantaneous injection driven by pneumatic pressure, greatly simplifying the injection procedure. A particular microstructure, called a "metering chamber", has been designed for the quantitative dispensing of an ultra-low volume of sample liquid; a "hydrophobic passive valve" equipped with an air vent channel is employed for injecting a dispensed sample into the separation channel. The reproducibility of dispensing was 3.3% (n = 15), expressed by the variation of dispensed volumes. The electrophoretic separation of DNA fragments was performed using this injection method, varying the injection volumes from 0.45 to 4.0 nL, and the separation efficiencies were compared. This precise injection method, easily variable in injection volumes, is highly suitable for quantitative as well as qualitative electrophoretic analyses.  相似文献   

2.
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip CE separations. The PDMS devices used for the evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3?psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~ 100?pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure, and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1?Hz to > 2?Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4-cm-long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations for multiplexing CE separations and for sample-limited bioanalyses are discussed.  相似文献   

3.
We developed a novel single‐step capillary electrophoresis (SSCE) scheme for miniaturized and easy to use system by using a microchannel chip, which was made from the hydrophilic material polymethyl methacrylate (PMMA), equipped with a capillary stop valve. Taking the surface tension property of liquids into consideration, the capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure in the wall of the microchannel. Through the combined action of stop valves and air vents, both sample plug formation for electrophoresis and sample injection into a separation channel were successfully performed in a single step. To optimize SSCE, different stop valve structures were evaluated using actual microchannel chips and the finite element method with the level set method. A partial barrier structure at the bottom of the channel functioned efficiently as a stop valve. The stability of stop valve was confirmed by a shock test, which was performed by dropping the microchannel chip to a floor. Sample plug deformation could be reduced by minimizing the size of the side partial barrier. By dissolving hydroxyl ethyl cellulose and using it as the sample solution, the EOF and adsorption of the sample into the PMMA microchannel were successfully reduced. Using this method, a 100‐bp DNA ladder was concentrated; good separation was observed within 1 min. At a separation length of 5 mm, the signal was approximately 20‐fold higher than a signal of original sample solution by field‐amplified sample stacking effect. All operations, including liquid introduction and sample separation, can be completed within 2 min by using the SSCE scheme.  相似文献   

4.
Effects of the electric field distribution on microchip valving performance   总被引:2,自引:0,他引:2  
Valving characteristics on microfluidic devices were controlled through manipulation of the electric field strengths during both the sample loading and dispensing steps. Three sample loading profiles for the constant volume valve (pinched injection) in conjunction with four dispensing schemes were investigated to study valving performance. The sample confinement profiles for the sample loading step consisted of a weakly pinched sample, a medium pinched sample, and a strongly pinched sample. Four dispensing schemes varied the electric field strengths in the sample and sample waste channels relative to the analysis channel to control the volume of the sample dispensed from the valve. The axial extent of the sample plug decreased as the electric field strengths in the sample and sample waste channels were raised relative to the analysis channel. In addition, a trade-off existed between sample plug length and sensitivity.  相似文献   

5.
An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 microL and a washing solvent loop of 0.5 microL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique.  相似文献   

6.
The applicability of programmable temperature vaporizer (PTV) solvent vent injection to the gas chromatographic (GC) determination of pesticide residues in fruits and vegetables was evaluated with the aim of miniaturizing the current multiresidue method. For that purpose 24 pesticides representing different chemical classes were initially chosen for optimisation of the large volume injection (LVI) parameters. Various parameters related to the optimum injector performance were tested for several types of packed and empty liners using both fast (at-once) and speed-controlled PTV solvent vent injection of standard solutions in ethyl acetate. In the next step, several packed and empty liners were evaluated for their suitability for pesticide multiresidue analysis. Parameters identified as optimal were then applied for PTV solvent vent injection of sample extracts prepared using the miniaturized multiresidue method to assess the long-term stability of the system. The combined use of large volume injection of 10 microl ethyl acetate extract into an empty multi-baffled or a CarboFrit packed liner using PTV injectors and GC-MS analysis enabled the detection and quantification of 124 pesticides in fruit and vegetable samples at the 0.01 mg/kg level using miniaturized reversed-phase solid-phase extraction (RP-SPE) of diluted acetone extract and clean-up on a small anion-exchange SPE column.  相似文献   

7.
Book reviews     
This work is a thorough investigation on the major operating parameters of the programmable temperature vaporisation (PTV) inlet used for gas chromatographic injection, including injection mode and volume, inlet temperature, vent and purge flow rates. The results clearly demonstrate the advantage of large volume injection in enhancing the detection of polybrominated diphenyl ethers (PBDEs). Partial loss of injected PBDEs occurred during solvent venting and due to incomplete sample transfer. Such loss was minimised by lowering the initial inlet temperature and vent flow and elevating the final inlet temperature. The results show that 50 mL/min vent flow, as low as 0°C initial and higher than 300°C final inlet temperatures produced the relatively high responses. Two mass spectrometric parameters were also evaluated. Indoor dust, lake sediment and human placenta tissue samples were analysed to demonstrate reliability and sensitivity improvement of the PTV large volume injection.  相似文献   

8.
Reproducible injection in capillary electrophoresis has been difficult to achieve with manual injection techniques using simple injection devices, such as gravity injection (siphoning) or hydrodynamic sample splitting. We demonstrate that the injection reproducibility can be improved using very simple means. With hydrodynamic sample splitter, a passive micro-metering valve can be inserted in-line to regulate the sample flow rate through the splitter interface. A significant improvement of both reproducibility and repeatability was achieved. The reproducibility of RSD of the peak areas improved from 25.4% to 4.4%, while the repeatability was below 4.1% when micro-metering valve was used. Additional simple correction that can be used to further improve the variability of injected sample volumes in any hydrodynamic injection mode in CE with conductivity detection was proposed and verified. The measured EOF peak can serve as a simple indicator of the injected volume and can be effectively used for additional correction. By a linear function between the injection volume and the peak area of the EOF, the RSD values of peak areas for both manual gravity injection and hydrodynamic sample splitter were further improved below 2% RSD. The linearity of the calibration curve was also significantly improved. The proposed correction works even with slight differences in matrix composition, as demonstrated on the analysis aqueous soil extract of model mixture of five nerve agent degradation products.  相似文献   

9.
Evaluation of frontal chromatograms   总被引:3,自引:0,他引:3  
A novel pressure-balanced injection valve was evaluated for use with ultrahigh pressure liquid chromatography (UHPLC) at pressures up to 120 MPa (1,200 bar). Fused-silica capillaries (30-33 cm x 100 microm I.D.) packed with nonporous 1.5 microm isohexylsilane-modified (C6) silica particles were employed to study maximum pressure, injection reproducibility, injection time, and sample amount consumed for an injection. The new valve was more reproducible, convenient, and required much less sample than previously used injection systems. The effect of column diameter on efficiency and sensitivity was studied. The 100 microm I.D. columns demonstrated approximately 40% lower efficiency but 10-fold higher sensitivity than the 29 microm I.D. columns. Columns packed with nonporous C6 particles produced higher efficiencies than columns packed with a 1.5 microm porous octadecylsilane-modified (C18) material.  相似文献   

10.
In gas chromatography (GC), highly volatile liquefied hydrocarbons are commonly injected using devices such as high-pressure syringes, piston valves, liquid rotary sampling valves, or vaporizing regulators. Although these techniques are adequate in some cases, there are known deficiencies. A new generation of sampling valve has been recently innovated and commercialized. Some of the highlights of the pressurized liquid injection system (PLIS) include compact size, the capability to directly couple to an injection port without the need for preinjection vaporization and transfer lines, and sample sizes ranging from 0.2 to 2.0 micro L. Although the valve has a specification of helium leak-free rating of 82.7 bar (1200 psig), the valve passes a hydrostatic pressure test of up to 414 bar (6000 psig). In the unheated version of PLIS, vaporization of solutes occur mainly because of the sheering effect of carrier gas in combination with thermal energy drawn from an injection port or a heated adaptor. This was found to be adequate for solutes with high to medium volatility of up to nC14 hydrocarbon. A higher molecular weight range of up to nC44 hydrocarbon can be achieved with the implementation of a heated version of PLIS, in which the channel of the shaft can be resistively heated at a rate of up to 400 degrees C/s. With its first introduction in May 2002, PLIS has gained acceptance amongst practitioners in GC because it addresses a key unarticulated need in sample introduction/enrichment and by specifically targeting many deficiencies encountered in contemporary high-pressure injection devices. In this paper, the design and performance of the various valve systems of PLIS, as well as industrial chromatographic applications, is presented.  相似文献   

11.
Wang W  Zhou F  Zhao L  Zhang JR  Zhu JJ 《Electrophoresis》2008,29(3):561-566
A simple method of hydrostatic pressure sample injection towards a disposable microchip CE device was developed. The liquid level in the sample reservoir was higher than that in the sample waste reservoir (SWR) by tilting microchip and hydrostatic pressure was generated, the sample was driven to pass through injection channel into SWR. After sample loading, the microchip was levelled for separation under applied high separation voltage. Effects of tilted angle, initial liquid height and injection duration on electrophoresis were investigated. With enough injection duration, the injection result was little affected by tilted angle and initial liquid heights in the reservoirs. Injection duration for obtaining a stable sample plug was mainly dependent on the tilted angle rather than the initial height of liquid. Experimental results were consistent with theoretical prediction. Fluorescence observation and electrochemical detection of dopamine and catechol were employed to verify the feasibility of tilted microchip hydrostatic pressure injection. Good reproducibility of this injection method was obtained. Because the instrumentation was simplified and no additional hardware was needed in this technology, the proposed method would be potentially useful in disposable devices.  相似文献   

12.
Large volume injection-programmable temperature vaporization-gas chromatography-mass spectrometry (LVI-PTV-GC-MS) was optimized for the determination of estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), mestranol (MeEE2) and estriol (E3) for their determination in environmental samples (estuarine water, wastewater, fish bile and fish homogenate) after derivatization with 25 μL (BSTFA+1% TMCS) and 125 μL of pyridine. Experimental designs such as Plackett-Burman (PBD) and central composite designs (CCDs) were used to optimize the LVI-PTV variables (cryo-focusing temperature, vent time, vent flow, vent pressure, injection volume, purge flow to split vent, splitless time and injection speed). Optimized conditions were as follows: 45 μL of n-hexane extract are injected at 60°C and 6 μL/s with a vent flow and a vent pressure of 50 mL/min and 7.7 psi, respectively, during 5 min; then the split valve is closed for 1.5 min and afterwards the injector is cleaned at 100 mL/min before the next injection. The method was applied to the determination of estrogenic compounds in environmental samples such as estuarine water, wastewater, and fish homogenate and bile. Limits of detection (0.04-0.15 ng/L for water samples, 0.04-0.67 ng/g for fish bile and 0.1-7.5 ng for fish homogenate) obtained were approx. ten times lower than those obtained by means of a common split/splitless inlet.  相似文献   

13.
Zhang L  Yin X  Fang Z 《Lab on a chip》2006,6(2):258-264
A simple method for injecting well-defined non-biased sample plugs into the separation channel of a microfluidic chip-based capillary electrophoresis system was developed by a combination of flows generated by negative pressure, electrokinetic and hydrostatic forces. This was achieved by using only a single syringe pump and a single voltage supply at constant voltage. In the loading step, a partial vacuum in the headspace of a sealed sample waste reservoir was produced using a syringe pump equipped with a 3-way valve. Almost instantaneously, sample was drawn from the sample reservoir across the injection intersection to the sample waste reservoir by negative pressure. Simultaneously, buffer flow from the remaining two buffer reservoirs pinched the sample flow to form a well-defined sample plug at the channel intersection. In the subsequent separation stage, the vacuum in headspace of the sample waste reservoir was released to terminate all flows generated by negative pressure, and the sample plug at the channel intersection was electrokinetically injected into the separation channel under the potential applied along the separation channel. The liquid levels of the four reservoirs were optimized to prevent sample leakage during the separation stage. The approach considerably simplified the operations and equipment for pinched injection in chip-based CE, and improved the throughput. Migration time precisions of 3.3 and 1.5% RSD for rhodamine123 (Rh123) and fluorescein sodium (Flu) in the separation of a mixture of Flu and Rh123 were obtained for 56 consecutive determinations with peak height precisions of 6.2% and 4.4% RSD for Rh123 and Flu, respectively.  相似文献   

14.
A new method for injecting and driving fluids by means of a multi-port injection valve and syringe pumps in a micro-channel network is described. A structure composed of two micro-channels arranged as a cross is connected with capillary tubes to an external multi-port injection valve. The fluid flows are driven by pressure and the multi-port valve controls the direction of the flow within the different sections of the structure. The first position of the multi-port valve allows the preparation of the loading of the sample, which is pinched in the cross section of the two micro-channels. The second position allows the precise injection of nL volumes. No dead volume exists between injection and separation modes. The system can be used to prepare a sample plug by pressure in order to perform chromatography with a broad range of buffered or non-buffered solutions. Thanks to the insensitivity to the ionic strength of the sample, this injection method is useful for the injection of complex biological samples in microchip analysis. In order to demonstrate the feasibility of the method, different solutions of ionic or fluorescent molecules were injected and detected in a photoablated planar polymer device.  相似文献   

15.
Zhang L  Yin X 《Electrophoresis》2007,28(8):1281-1288
A simple and powerful microfluidic array chip-based electrophoresis system, which is composed of a 3-D microfluidic array chip, a microvacuum pump-based negative pressure sampling device, a high-voltage supply and an LIF detector, was developed. The 3-D microfluidic array chip was fabricated with three glass plates, in which a common sample waste bus (SW(bus)) was etched in the bottom layer plate to avoid intersecting with the separation channel array. The negative pressure sampling device consists of a microvacuum air pump, a buffer vessel, a 3-way electromagnet valve, and a vacuum gauge. In the sample loading step, all the six samples and buffer solutions were drawn from their reservoirs across the injection intersections through the SW(bus) toward the common sample waste reservoir (SW(T)) by negative pressure. Only 0.5 s was required to obtain six pinched sample plugs at the channel crossings. By switching the three-way electromagnetic valve to release the vacuum in the reservoir SW(T), six sample plugs were simultaneously injected into the separation channels by EOF and electrophoretic separation was activated. Parallel separations of different analytes are presented on the 3-D array chip by using the newly developed sampling device.  相似文献   

16.
A fully automated method for the determination of six phthalates in environmental water samples is described. It is based in the novel sample preparation concept of in‐syringe dispersive liquid–liquid microextraction, coupled as a front end to GC–MS, enabling the integration of the extraction steps and sample injection in an instrumental setup that is easy to operate. Dispersion was achieved by aspiration of the organic (extractant and disperser) and the aqueous phase into the syringe very rapidly. The denser‐than‐water organic droplets released in the extraction step, were accumulated at the head of the syringe, where the sedimented fraction was transferred to a rotary micro‐volume injection valve where finally was introduced by an air stream into the injector of the GC through a stainless‐steel tubing used as interface. Factors affecting the microextraction efficiency were optimized using multivariate optimization. Figures of merit of the proposed method were evaluated under optimal conditions, achieving a detection limit in the range of 0.03–0.10 μg/L, while the RSD% value was below 5% (n = 5). A good linearity (0.9956 ≥ r2 ≥ 0.9844) and a broad linear working range (0.5–120 μg/L) were obtained. The method exhibited enrichment factors and recoveries, ranging from 14.11–16.39 and 88–102%, respectively.  相似文献   

17.
采用改变相比/顶空气相色谱法测定了甲烷、乙炔、乙烯、乙烷和丙烷在变压器油中的分配常数。顶空瓶中的气体样品经石英毛细管送到气相色谱仪的六通进样阀样品管中,然后进行分离和定量。采用标准曲线法定量,通过测定5个不同相比时轻烃组分的顶空浓度,计算顶空浓度倒数与相比之间的线性回归方程,测定了20 ℃和50 ℃时烃类气体在变压器油中溶解气体的分配常数。除甲烷外,计算所得的分配常数与文献值基本吻合,油中溶解气体浓度的实验值与实际值之间的相对误差小于4.14%,表明用此方法可以测定不同温度下变压器油中溶解气体的分  相似文献   

18.
This Article introduces and experimentally explores a novel self-regulating method for reducing the friction losses in large microchannels at high liquid pressures and large liquid flows, overcoming previous limitations with regard to sustainable liquid pressure on a superhydrophobic surface. Our design of the superhydrophobic channel automatically adjusts the gas pressure in the lubricating air layer to the local liquid pressure in the channel. This is achieved by pneumatically connecting the liquid in the microchannel to the gas-pockets trapped at the channel wall through a pressure feedback channel. When liquid enters the feedback channel, it compresses the air and increases the pressure in the gas-pocket. This reduces the pressure drop over the gas-liquid interface and increases the maximum sustainable liquid pressure. We define a dimensionless figure of merit for superhydropbic flows, W(F) = P(L)D/γ cos(θ(c)), which expresses the fluidic energy carrying capacity of a superhydrophobic microchannel. We experimentally verify that our geometry can sustain three times higher liquid pressure before collapsing, and we measured better friction-reducing properties at higher W(F) values than in previous works. The design is ultimately limited in time by the gas-exchange over the gas-liquid interface at pressures exceeding the Laplace pressure. This method could be applicable for reducing near-wall laminar friction in both micro and macro scale flows.  相似文献   

19.
A new and simple method of solventless extraction of volatile organic compounds (VOCs) from air is presented. The sampling device has an adsorbing carbon coating on the interior surface of a hollow needle, and is called the inside needle capillary adsorption trap (INCAT). This paper describes a study of the reproducibility in the preparation and sampling of the INCAT device. In addition, this paper examines the effects of sample volume in active sampling and exposure time in passive sampling on the analyte adsorption. Analysis was achieved by sampling the air from an environmental chamber doped with benzene, toluene, ethyl benzene and xylenes (BTEX) compounds. Initial rates of adsorption were found to vary among the different compounds, but ranged from 0.0099 to 0.016 nmol h(-1) for passive sampling and from 2.2 to 10 nmol h(-1) for active sampling. Analysis was done by thermal desorption of the adsorbed compounds directly into a gas chromatograph injection port. Quantification of the analysis was done by comparison to actively sampled activated carbon solid phase extraction (SPE) measurements.  相似文献   

20.
A comparative study was conducted to assess the injection precision in capillary electrophoresis for cationic analytes (arecoline, codeine, papaverine). The precision was measured in respect to methods sensitivity in various injection modes in capillary electrophoresis: standard hydrodynamic injection (3.45 kPa for 6 s), large volume sample stacking (3.45 kPa for 40 s), and field‐amplified sample injection (10 kV for 65 s). All measurements were conducted for aqueous solutions of standards to minimize the errors linked to the sample preparation step. The methods were submitted to precision assessment at three concentration levels: at the limit of quantification, three‐fold and ten‐fold of limit of quantification. The results were compared to those from high‐performance liquid chromatography as a reference technique. The field‐amplified sample injection method was shown to provide greatest sensitivity (quantification limits down to 4 ng/mL for all three tested compounds) but the lowest precision. High‐performance liquid chromatography was established as the most reliable technique (coefficient of variation in all intraday experiments was below 1%). It was also shown that with a use of large volume sample injection technique, similar sensitivity as in high‐performance liquid chromatography can be easily reached.  相似文献   