1.
胶束电动毛细管色谱分离氨基酸和磷酸化氨基酸   总被引:2,自引:0,他引:2  
本文报道了胶束电动毛细管色谱分离、汞灯诱导荧光电荷耦合器件检测分析氨基酸和磷酸化氨基酸的 4-氟 - 7-硝基苯 - 2 - 口恶 - 1 ,3-丫唑衍生物。研究表明 ,在 p H9.35的 1 0 mmol/L硼砂和 1 0 mmol/L十二烷基硫酸钠的电泳缓冲介质中 ,5种氨基酸和 3种磷酸化氨基酸在 1 0 min内完全分离 ,检测灵敏度为 1 .2 1× 1 0 - 8~ 5 .2 1×1 0 - 8mol/L ,分离效率达 7.3× 1 0 5~ 3.0× 1 0 5/m理论塔板数 ,结果令人满意  相似文献   

2.
The fluorescent reagent 6-oxy-(N-succinimidyl acetate)-9-(2′-methoxycarbonyl)fluorescein (SAMF), has been newly synthesized for use as a label for characterization of phosphoamino acids by micellar electrokinetic capillary electrophoresis (MEKC) with laser-induced fluorescence (LIF) detection. The conditions for derivatization and separation of the phosphoamino acids, including pH, concentration of electrolyte, and Brij-35 concentration were optimized in detail. Derivatization was performed at 35 °C for 10min in borate buffer (pH 8.0). The derivatives were separated to baseline by use of running buffer containing 50 mM borate and 20 mM Brij-35 at pH 9.3. Detection limits ranged from 5 × 10?11 to 1 × 10?9 mol L?1 (signal to noise ratio = 3). The method was used for characterization of the phosphoamino acids in a sample from hydrolysis of a novel protein kinase from tobacco cells.  相似文献   

3.
A method was developed for the determination of phosphoamino acids by capillary zone electrophoresis-laser-induced fluorescence detection (argon ion laser, excitation at 488 nm and emission at 520 nm) using derivatization with N-hydroxysuccinimidyl fluorescein-O-acetate (SIFA). Different variables affecting the derivatization (SIFA concentration, derivatization pH, reaction temperature and reaction time) and the separation (type, pH and concentration of buffer, applied voltage and injection mode) were investigated in detail. The optimized separation conditions were 40 mM boric acid buffer (pH 9.2) for background electrolyte, 25 kV for the separation voltage, 25 degrees C for the capillary temperature and 5 s at 0.5 psi for the sample injection. Under the optimal conditions, the SIFA-labeled phosphoamino acids were fully separated within 7 min. The detection limits ranged from 0.1 to 0.3 nM, which are the lowest values reported for capillary electrophoresis (CE) methods. The proposed methodology allowed the rapid, sensitive and selective determination of phosphoamino acids in hen egg yolk phosvitin by the standard addition method. The recovery of these compounds in real sample was 94.0-103.5%. The developed method surpasses previously published CE methods in terms of detection limit, separation time, stability and simplicity of the electrophoretic procedure.  相似文献   

4.
We report the use of a sheath flow reactor for post-column fluorescence derivatization of proteins. The derivatization reaction employed naphthalene-2,3-dicarboxaldehyde (NDA) and beta-mercaptoethanol, which were added in the sheath buffer. The labeled proteins were detected by laser-induced fluorescence with an argon-ion laser beam at 488 nm. The performance of this detection scheme was evaluated by separation of some protein standards. A column efficiency of 450,000 plates/m was obtained without stacking. The limits of detection for those standard proteins were determined to be from 8 to 32 nM. Excellent linear relationship was obtained with correlation coefficient of 0.9998 for alpha-lactalbumin concentration ranging from 3.91 x 10(-7) to 1.25 x 10(-5) M. Separation of protein standards at low pH was also demonstrated by reversing the electroosmotic flow (EOF) with addition of cetyltrimethylammonium bromide (CTAB) to the running buffer. Different separation selectivity was achieved, but the sensitivity is poorer than that at high pH. This post-column derivatization detection system was applied successfully to analyze the protein extract from HT29 human colon cancer cells as well as tryptic peptides.  相似文献   

5.
A micellar electrokinetic capillary chromatography (MEKC) method with laser-induced fluorescence detection (LIF) was developed for analyzing three phosphoamino acids including phosphotyrosine (P-Tyr), phosphoserine (P-Ser), and phosphothreonine (P-Thr). 3-(2-Furoyl)quinoline-2-carboxaldehyde (FQ), a fluorogenic dye, was employed for derivatization of these phosphoamino acids. Results indicated that the complete baseline resolution of each phosphoamino acid was obtained within 10 min, using 20 mmol l−1 sodium borate buffer (pH 9.35) containing 20 mmol l−1sodium deoxycholate (SDC) and 10 mmol l−1 Brij35. Other common amino acids, especially Glu and Asp, did not disturb the assay of these phosphoamino acids. There was a linear relationship between the peak area for analyte and its concentration, with correlation coefficients in the range of 0.9966-0.9996. The concentration detection limits (signal-to-noise = 3) for P-Tyr, P-Ser, and P-Thr were 10, 40, and 75 nmol l−1, respectively. The developed method was successfully applied for determining phosphoamino acids in the hydrolysis sample of a phosphorylated protein kinase.  相似文献   

6.
Zhao S  Xie C  Lu X  Song Y  Liu YM 《Electrophoresis》2005,26(9):1745-1750
It was found that native amino acids enhanced the chemiluminescence (CL) reaction between luminol and BrO(-) in an alkaline aqueous solution. This has led to the development of a facile and highly sensitive CL detection scheme for the determination of amino acids in biological samples after capillary electrophoretic (CE) separation. The CE-CL conditions were optimized. An electrophoretic buffer of 2.5 x 10(-2) M sodium borate (pH 9.4) containing 1 x 10(-4) M luminol was used. The oxidizer solution of 8 x 10(-4) M NaBrO in 0.1 M sodium carbonate buffer solution (pH 12.5) was introduced post-column. Under the optimal conditions, the detection limits were 1.0 x 10(-7) M for glutamic acid (Glu) and 1.3 x 10(-7) M (S/N = 3) for aspartic acid (Asp). The relative standard deviations (RSDs) of peak area and migration time were in the ranges of 3.8-4.3% and 1.4-1.6%, respectively. The present method was applied to the determination of excitatory amino acids (i.e., Asp and Glu) in rat brain tissue and monkey plasma. The levels of these major excitatory amino acids in monkey plasma were quantified for the first time and found to be 1.17 +/- 0.17 x 10(-5) M (mean +/- SD, n = 6) for Glu and 1.64 +/- 0.19 x 10(-6) M for Asp, which were comparable with the levels in human plasma.  相似文献   

7.
A rapid and sensitive method was developed for the analysis of amino acids by microchip electrophoresis with Hg-lamp excitation fluorescence detection. Fluorescein-isothiocyanate (FITC) was chosen to estimate the sensitivity of this system, and the detection limit (S/N = 3) with FITC was 1.7 nM, which showed that the system was sensitive as well as simple. Two derivatizing agents, FITC and ortho-phthalaldehyde (OPA) were employed to label amino acids and were compared in the same fluorescence detection system with an Hg lamp as the excitation source. The separation parameters were optimized in detail. Optimum separation of OPA-labeled amino acids was obtained in less than 200 s with 20 mM borate buffer (pH 9.0) containing 20% acetonitrile and 10 mM beta-cyclodextrin. Detection limits for amino acids (alanine (Ala), taurine (Tau), glycine (Gly), glutamic acid (Glu), and aspartic acid (Asp)) of 0.38-1.0 muM were achieved. The method was successfully applied to analysis of amino acids in human vascular endothelial cells (ECV-304). The average amount of amino acids in single ECV-304 cells is estimated to be 5.84 fmol for Ala, 2.78 fmol for Tau, 1.15 fmol for Gly, 3.10 fmol for Glu, and 1.30 fmol for Asp.  相似文献   

8.
Cao L  Wang H  Zhang H 《Electrophoresis》2005,26(10):1954-1962
The analytical potential of a fluorescein analogue, 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein (SAMF), for the first time synthesized in our laboratory, as a labeling reagent for the labeling and determination of amino compounds by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was investigated. Biogenic monoamines and amino acids were chosen as model analytes to evaluate the analytical possibilities of this approach. The derivatization conditions and separation parameters for the biogenic amines were optimized in detail. The derivatization was performed at 30 degrees C for 6 min in boric acid buffer (pH 8.0). The derivatives were baseline-separated in 15 min with 25 mM boric acid running buffer (pH 9.0), containing 24 mM SDS and 12.5% v/v acetonitrile. The concentration detection limit for biogenic amines reaches 8 x 10(-11) mol.L(-1) (signal-to-noise ratio = 3). The application of CE in the analysis of the SAMF-derivatized amino acids was also exploited. The optimal running buffer for amino acids suggested that weak acidic background electrolyte offered better separation than the basic one. The proposed method was applied to the determination of biogenic amines in three different beer samples with satisfying recoveries varying from 92.8% to 104.8%. Finally, comparison of several fluorescein-based probes for amino compounds was discussed. With good labeling reaction, excellent photostability, pH-independent fluorescence (pH 4-9), and the resultant widely suited running buffer pH, SAMF has a great prospect in the determination of amino compounds in CE.  相似文献   

9.
Becker A  Scheuch E  Bode U  Jaehde U 《Electrophoresis》2002,23(15):2457-2464
The suitability of micellar electrokinetic chromatography (MEKC) coupled with diode array or laser-induced fluorescence (LIF) detection to analyze the four sulfur-containing excitatory amino acids (SEAA), homocysteine sulfinic acid (HCSA), homocysteic acid (HCA), cysteine sulfinic acid (CSA), and cysteic acid (CA) was investigated. 5-Carboxy-fluorescein succinimidyl ester was chosen as fluorescent reagent to derivatize HCSA, HCA, CSA, and CA. During method development, the yield of reaction dependent on pH and incubation time as well as the stability of the products were analyzed. The maximum yield was obtained after 30 min using a 0.1 M borate buffer (pH 8.9) as derivatization buffer. Each labeled amino acid exhibited high stability at room temperature over a period of 5 days. Baseline separation of labeled HCSA, HCA, CSA, and CA was obtained using a buffer consisting of 0.1 M borate, 50 mM sodium dodecyl sulfate (SDS), and 5% v/v methanol (pH 9.0). By applying LIF detection, limits of detection ranged from 0.9 x 10(-10) M for HCSA to 6.0 x 10(-10) M for CA, respectively. Slightly modified separation conditions enabled the analysis of SEAA in cerebrospinal fluid in the presence of the neurotransmitters glutamate and aspartate. In conclusion, MEKC coupled with LIF detection is a suitable technique for the simultaneous and sensitive analysis of SEAA. Further work will focus on the validation of the method with cerebrospinal fluid as sample matrix.  相似文献   

10.
Microchip electrophoresis for the short-time analysis of amino acids in Japanese green tea was developed. The amino acids in Japanese green tea were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). The derivatives were filtered and directly analyzed by electrophoresis on a plastic microchip with a 31-mm long separation channel with fluorescence detection. Amino acid analysis of Japanese green tea was improved by removing polyphenols using a polyvinylpolypyrrolidone pretreatment. Elution profiles of NBD-amino acids were examined under different running buffer conditions, and the sodium dodecyl sulphate in the running buffer exhibited a dramatically high-separation efficiency of amino acids by inhibiting their adsorption on the channel walls. Under the optimized conditions (5 mM phosphate buffer (pH 5.5) containing 0.05 mM sodium dodecylsulfate as running buffer), the main amino acids contained in Japanese green tea were well separated within 2 min, and theanine (1475 mg/100 g tea leaf), Arg (408 mg/100 g tea leaf) and Gln (217 mg/100 g tea leaf) were detected in Japanese green tea.  相似文献   

11.
High-voltage contactless conductivity detection of underivatized amino acids in both acidic and basic media is demonstrated. The suitability of different acidic buffer solutions at pH values of about 2.5 was investigated with 12 amino acids. Lactic acid as background electrolyte gave the best results in terms of detection limits for arginine, lysine and histidine, which were approximately 2 x 10(-7), 3 x 10(-7) and 4 x 10(-7) M, respectively. However, the sensitivity for other species was not quite as good and the detection limits in the order of 0.5-1 x 10 (-5) M. The use of basic conditions at pH 10-11 generally led to more stable baselines and more consistent sensitivities. A range of 20 amino acids was investigated with alkaline buffers and detection limits were typically about 10(-6) M. Urine and beer samples were analyzed. Nine and eleven amino acids could be identified, respectively.  相似文献   

12.
综述了2003年以来,采用高效液相色谱(HPLC)和毛细管电泳(CE)分离,荧光检测神经递质氨基酸、磷酸化氨基酸、脂肪胺和生物胺等小分子氨基生物物质的分析方法进展。对上述氨基生物物质测定方法的前景进行了展望。引用文献52篇。  相似文献   

13.
A high-performance liquid chromatographic system has been developed which permits the separation of both acid-stable and acid-labile phosphoamino acids. An anion-exchange resin and two buffers of different ionic strength and near neutral pH are used. A low-ionic-strength buffer is used for the separation of N-omega-phosphoarginine and N-epsilon-phospholysine, while the higher-ionic-strength buffer permits the clear separation of tau-phosphohistidine, omicron-phosphoserine and omicron-phosphothreonine. An in-stream fluorometric detection system using omicron-phthalaldehyde permits the rapid analysis of samples containing as little as 25 pmoles of phosphoamino acid. This method has been applied to the detection of tau-phosphohistidine from alkaline digests of chemically phosphorylated calf thymus histone 4 and bovine myelin basic protein.  相似文献   

14.
Yu CZ  He YZ  Han F  Fu GN 《Journal of chromatography. A》2007,1171(1-2):133-139
A post-column reactor with coaxial-gap mode is developed for laser-induced fluorescence detection (LIF) in capillary electrophoresis (CE). The reactor can be assembled simply and conveniently, in which a thin polyimide sleeve of 10-mm length obtained from the capillary coating is used to align separation and reaction capillary with a 20 microm gap. Naphthalene-2,3-dicarboxaldehyde and 2-mercaptoethanol are used as derivatization reagents and delivered into the reaction capillary through the annulus between the separation capillary and polyimide sleeve and the gap of two capillaries by gravity. A reaction distance from the gap to detection point is 5mm. For the post-column reactor of CE-LIF, several configuration parameters are optimized, including liquid level difference between the derivatization solution and outlet buffer, annular dimension between the outer diameter of etched separation capillary and the inner diameter of polyimide sleeve, and reaction distance, etc. The detection limits in the range from 8.0x10(-8) to 1.0x10(-6) mol/L and linear calibration range more than two orders of magnitude are obtained for amino acids. The separation efficiency ranges from 1.35x10(5) to 1.67x10(5) theoretical plates.  相似文献   

15.
A mixed micellar electrokinetic chromatography method with fluorescence detection was developed to simultaneously monitor gamma-aminobutyric acid (GABA), glutamate (Glu) and alanine (Ala) in biological samples. Amino acids were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA). The separation of three NDA-labeled isomers (GABA, alpha-ABA, beta-ABA) was studied in detail with different micelles solutions such as sodium dodecyl sulfate (SDS), beta-cyclodextrin (beta-CD) and sodium cholate (SC). Simultaneous resolution of GABA, Glu and Ala from 21 amino acids was achieved within 5 min using 20 mM phosphate buffer at pH 8.7 containing 24 mM SC and 26 mM SDS. The detection limits were 4.0 x 10(-8), 1.1 x 10(-8) and 1.3 x 10(-8) M, for GABA, Glu and Ala, respectively, with S/N = 2. The method was applied to monitor the changes of amount of GABA, Glu and Ala in tobacco leaf in response to cold and dark stress.  相似文献   

16.
Wang J  Chen G 《Talanta》2003,60(6):1239-1244
A method based on microchip capillary electrophoresis with amperometric detection was developed for the rapid separation and direct detection of oxidizable aromatic amino acids (without prior derivatization). The working electrode was a thick-film carbon strip electrode positioned opposite the outlet of the separation channel. Factors influencing the separation and detection processes were examined and optimized. The five aromatic amino acids, tyrosine, 5-hydroxytryptophan, tryptophan, p-aminobenzoic acid, and m-aminobenzoic acid, can be well separated within 5 min using a separation voltage of 2000 V and a 25 mM phosphate buffer (pH 7.0) run buffer containing 50 mM sodium dodecylsulfate. Most favorable amperometric detection was obtained at +0.95 V. Linear calibration plots are observed for micromolar concentrations of the oxidizable amino acids. The new protocol offers good stability and for reproducibility, with relative S.D. of less than 5% for both migration times and peak currents (n=8). It should be useful for the analysis of aromatic amino acids, as desired for life sciences.  相似文献   

17.
An approach to the chiral separation of racemic mixtures of amino acids by means of micellar electrokinetic chromatography after derivatization with a new triazine spectroscopic reagent, 3-(4,6-dichloro-1,3,5-triazinylamino)-7-dimethylamino-2-methylphenazine (DTDP), has been evaluated. It was found that the derivatives of the aliphatic amino acids such as serine, valine and arginine, could produce a strong UV absorption at 282 nm, whose apparent molar absorptivities are of 10(-4) M(-1) cm(-1), and thus the concentration of the amino acids down to 3 x 10(-7) M can still give a detectable signal (S/N = 3). Beta-Cyclodextrin (beta-CD) added to the buffer system was used as a chiral selector, and separation conditions were optimized. The presence of an organic modifier (2-propanol) was also a prerequisite for the chiral separation. The best results for the chiral separation of DTDP-amino acids were achieved in a mixed sodium dodecylsulfate-beta-CD-borate-2-propanol medium at pH 9.0. Compared to some of the commonly used derivatization methods, the present one offers a relatively stable derivative and strong UV absorption for the spectroscopically inert amino acids, thus enabling amino acids to be separated and detected by CE even with a simpler UV detector.  相似文献   

18.
Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When sodium acetate eluent concentration is changed, the selectivity variations between strongly retained amino acids containing two carboxyl groups and containing only one carboxyl group are obviously different. Significant but slight selectivity changes in weakly retained amino acids can be achieved through changing the column temperature. Sodium hydroxide and sodium acetate eluent concentration affect the detection of amino acids. Detection sensitivity of amino acids can be improved by increasing the concentration of sodium hydroxide and sodium acetate in a certain concentration range. The detections of amino acids at two different detection waveforms were compared. The hydroxyl amino acids can be selectively detected by choosing a modified detection waveform. The optimized gradient elution condition and column temperature for analyzing 19 amino acids were obtained. The time for the gradient elution program was 60 min. The column temperature was 35 degrees C. Under the optimized conditions, detection limits for 19 amino acids were 0.15-4.52 pmol. The calibration graphs of peak area for all the analytes were linear for about three orders of magnitude. The RSDs (n=5) of peak area were 0.6-5.6%. The determination of trace amino acid impurities in valine product is shown as an application example.  相似文献   

19.
建立了一种用于测定中药制剂中氨基酸成分的毛细管电泳-荧光检测方法. 用含有α-环糊精(α-CD)的硼砂缓冲溶液为背景电解质, 经异硫氰酸荧光素(FITC)衍生的5种氨基酸在50 min内可以得到很好的分离和测定. 考查了各个分离参数对分离的影响, 得到的优化条件为: 含45 mmol/L的α-环糊精的80 mmol/L硼砂缓冲溶液(pH值9.2)作为背景电解质, 分离电压20 kV; 柱温22 ℃. 衍生试剂FITC与单个氨基酸的化学计量比为4∶1时, 能够获得稳定荧光强度的氨基酸衍生物. 在优化条件下, 各氨基酸成分在73.5~2900 nmol/L 的浓度范围内呈良好的线性关系(相关系数r2为0.9906~0.9998). 保留时间和峰面积的相对标准偏差分别为0.8%~3.0%和0.7%~5.7%, 检测限(3倍信噪比)为3.5~35 nmol/L. 该方法准确可靠, 可用于质量控制为目的的中药制剂中氨基酸成分的定量测定.  相似文献   

20.
Molina M  Silva M 《Electrophoresis》2001,22(6):1175-1181
The potential of micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection for the separation and determination of phosphorus-containing amino acid-herbicides (glufosinate and glyphosate), and aminomethylphosphonic acid (the major metabolite of glyphosate), involving derivatization with fluorescein isothiocyanate (FITC) isomer I, was investigated. Different variables that affect derivatization (pH, FITC concentration, time and temperature) and separation (pH and concentration of the buffer, kind and concentration of surfactants and applied voltage) were studied. The analysis was conducted within about 8 min and the use of the nonionic surfactant Triton X-100 improved the selectivity, thus indirectly enhancing sensitivity by shifting of the interfering peaks of the FITC excess. Dynamic ranges of 2.0-3,000 microg/L, limits of detection at microgram or submicrogram-per-liter level, and relative standard deviations from 4.7 to 6.4% were obtained. The ensuing method--nonionic surfactant MEKC-- is a useful choice for the determination of these herbicides as it provides limits of detection similar or lower than those reported by existing chromatographic alternatives without the use of an additional preconcentration technique such as solid-phase extraction. The separation of a mixture of nine FITC-derivatized amino acids, selected as target compounds, was also carried out to assess the discrimination power of the nonionic surfactant MEKC method for the analysis of closely related anionic analytes.  相似文献   