首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A method was developed and validated for determination and quantitation of tilmicosin residues in swine, cattle, and sheep edible tissues, as well as chicken fat, skin, and muscle over a concentration range of 0.025 microg/g-20 microg/g. For chicken kidney and liver, the method was validated over a range of 0.060 microg/g-20 microg/g. The tissue sample was extracted with methanol and a C18 cartridge was used for solid-phase extraction cleanup. A reversed-phase gradient liquid chromatographic method with detection at 280 nm was used to separate the tilmicosin from matrix components in 30 min run time. The limit of quantitation (LOQ) of the method was 0.025 microg/g for all tested tissues except chicken kidney and liver, for which the LOQ was 0.06 microg/g. Average recoveries for tissue samples ranged from 73 to 98%. Relative standard deviation values ranged from 0.6 to 14.7%.  相似文献   

2.
A liquid chromatographic method was developed that provides a simple and rapid means of determining methyl anthranilate (MA) in carbonated and noncarbonated, artificial grape-flavored, nonalcoholic beverages. The proposed procedure, which was applied to 12 different products, uses a Nova-Pak C18 column, a mobile phase containing acetonitrile-0.025M KH2PO4 (40 + 60), pH 3.00, and UV detection at 220 nm. Assay values ranged from 0.35 to 16.6 microg MA/mL. The intralaboratory precision (relative standard deviation) for the products ranged from 0.51 to 2.23% (n = 5), and recoveries via fortification ranged from 83.6 to 102.4%. The limits of quantitation and detection were 0.00417 and 0.00125 microg/mL, respectively, and the analyte response was linear over a 100-fold concentration range (0.0001-0.01 mg/mL).  相似文献   

3.
4.
An accurate and precise RP-HPLC method was developed and validated for the determination of carbamazepine and its impurities iminostilbene and iminodibenzyl in a tablet formulation with fluphenazine as an internal standard. Buffer-methanol (50 + 50, v/v) was used as the mobile phase. During validation, specificity, linearity, precision, accuracy, LOD, LOQ, and robustness of the method were tested. The method was proven to be specific against placebo interference. Linearity was evaluated over the concentration range of 100-500, 0.05-0.25, and 0.1-0.5 microg/mL, and the r values were 0.9994, 0.9997, and 0.9979 for carbamazepine, iminostilbene, and iminodibenzyl, respectively. Intraday precision of the method was good, and RSD was below 2% for all analytes. The accuracy of the method ranged from 100.69 to 102.10, 99.76 to 102.66, and 99.26 to 100.08% for carbamazepine, iminostilbene, and iminodibenzyl, respectively. LOD was 0.0125, 0.025, and 0.05 microg/mL and LOQ was 0.05, 0.05, and 0.1 microg/mL for carbamazepine, iminostilbene, and iminodibenzyl, respectiviely. Robustness of the method was proven by using a chemometric approach. The method was successfully applied to the analysis of commercially available carbamazepine tablets and showed good repeatability, with RSD below 2%.  相似文献   

5.
A multiresidue method for the determination of more than 80 pesticides in water has been developed and validated. The proposed method is based on SPE followed by GC coupled to MS/MS. Different variables affecting SPE procedure, such as cartridges, sample volume and solvents were studied, and mass spectrometric conditions were optimised in order to increase selectivity and sensitivity. Calibration curves were linear over the range of 0.03-0.5 microg/L. Recoveries were in the range of 70-110% and repeatability was below 20% for the lowest calibration point. LODs ranged from 0.001 to 0.025 microg/L and LOQs from 0.003 to 0.076 microg/L. Finally, the method was successfully applied to the analysis of water samples from southeast of Spain.  相似文献   

6.
A new confirmatory method for three macrolides (tylosin, tilmicosin and erythromycin) in bovine muscle, liver and kidney by micro-LC-MS-MS using an atmospheric pressure ionisation source and an ionspray interface has been developed. Roxithromycin was used as internal standard. The molecular related ions, [M+2H]2+, at m/z 435 for tilmicosin, and [M+H]+, at m/z 734 and 916 for erythromycin and tylosin, respectively, were the precursor ions for collision-induced-dissociation and two diagnostic product ions for each macrolide were identified for the unambiguous confirmation by selected reaction monitoring LC-MS-MS. Precision values (relative standard deviations) were all below 14.9%, whereas the overall accuracy (relative error) ranged from -17.7 to -9.8% for tylosin, from -17.5 to -10.7% for tilmicosin and from -19.6 to -13.7% for erythromycin, in all the investigated bovine tissues. The limits of quantification were 30 (muscle) or 40 (liver, kidney) microg kg(-1), 20 (muscle) or 150 (liver, kidney) microg kg(-1), 50 (muscle, liver) or 80 (kidney) microg kg(-1), 20 (muscle, liver) or 50 (kidney) microg kg(-1) for tylosin, tilmicosin, erytromycin and roxithromycin, respectively.  相似文献   

7.
A simple liquid chromatography (LC) method was developed for determination of the therapeutic level of mizoribine in human plasma. After precipitation of plasma proteins with 6% perchloric acid, mizoribine was determined by LC with spectophotometric detection. The peak height for mizoribine was linearly related to its concentrations, which ranged from 0.09 to 3.13 microg/mL. Therefore, the limit of quantitation was considered to be 0.09 microg/mL. The accuracy was 104.96-107.37%. The intra- and interday relative standard deviation values were in the range of 1.10-3.25%. The detection limit was 0.025 microg/mL, defined as a signal-to-noise ratio of 3. The plasma concentrations of mizoribine were not related to the dosage. Because mizoribine was mainly excreted in the urine, the plasma concentrations of mizoribine might be affected by a change in renal function. Therefore, the mizoribine concentration in blood should be monitored and the dosage adjusted, depending on the condition of renal function. It was suggested that the present method may be applied well in the therapeutic drug monitoring for mizoribine.  相似文献   

8.
A forced degradation study on glibenclamide was performed under conditions of hydrolysis, oxidation, dry heat, and photolysis and a high-performance column liquid chromatographic-ultraviolet (HPLC-UV) method was developed to study degradation behavior of the drug under the forced conditions. The degradation products formed under different forced conditions were characterized through isolation and subsequent infrared/nuclear magnetic resonance/mass spectral analyses, or through HPLC/mass spectrometric (HPLC/MS) studies. The drug degraded in 0.1 M HCI and water at 85 degrees C to a major degradation product, 5-chloro-2-methoxy-N-2-(4-sulfamoylphenyl)ethyl]benzamide (III), and to a minor product, 1-cyclohexyl-3-[[4-(2-aminoethyl)-phenyl]sulfonyl]urea (IV). Upon prolonged heating in the acid, the minor product IV disappeared, resulting in formation of 5-chloro-2-methoxy-benzoic acid (II) and an unidentified product (I). Heating of the drug in 0.1 M NaOH at 85 degrees C yielded II and IV as the major products and I and III as the minor products. The drug and the degradation products formed under different conditions were optimally resolved on a C18 column using ammonium acetate buffer (0.025 M, pH 3.5)-acetonitrile (45 + 55) mobile phase at a flow rate of 0.6 mL/min, with detection at 230 nm. The method was validated for linearity, precision, accuracy, and specificity. Limit of detection (LOD) and limit of quantitation (LOQ) values were also determined. The method could be successfully applied for simultaneous quantification of glibenclamide and the major product, III. The response of the method was linear in a narrow [0.4-10 micro/mL, correlation coefficient (r2) = 0.9982] and a wide (0.4-500 microg/mL, r2 = 0.9993) concentration range for glibenclamide, and in the concentration range of 0.025-50 microg/mL (r2 = 0.9998) for III. The method proved to be precise and accurate for both glibenclamide and III. It was specific for the drug and also selective for each degradation product, and LOQ values for the drug were 0.1 and 0.4 microg/mL, whereas those for III were 0.010 and 0.025 microg/mL, respectively.  相似文献   

9.
吴映璇  谢敏玲  姚仰勋  蓝草 《色谱》2018,36(8):752-757
建立了高效液相色谱-串联质谱快速测定牛奶和羊奶中莫奈太尔及其代谢产物残留量的分析方法。样品经乙腈沉淀蛋白质,中性氧化铝固相萃取柱净化,以Inertsil C8-3(150 mm×4.6 mm,5 μm)色谱柱分离,甲醇-乙酸铵溶液为流动相进行梯度洗脱,采用电喷雾负离子监测模式检测,外标法定量。结果表明,在0.1~5.0 μg/L范围内,待测物色谱峰面积与其质量浓度间的线性关系良好(相关系数均大于0.99),定量限为2.0 μg/kg。莫奈太尔及其代谢产物在2类基质中3个水平(2.0、50和100 μg/kg)下的加标回收率为90.1%~103.3%,相对标准偏差(RSD)为2.0%~6.2%(n=6)。该方法操作简便、快速,灵敏度高,抗干扰能力强,回收率和重复性良好,能够满足牛奶和羊奶中莫奈太尔及其代谢产物残留量的检测要求。  相似文献   

10.
A liquid chromatographic method for the determination of closantel residues in milk and tissues is developed and validated. An acetonitrile-acetone solution (80:20, v/v) is used for the extraction of closantel residues from milk and animal tissues, and the extract is purified by solid-phase extraction with Oasis MAX cartridges and a mixture of formic acid-acetonitrile (5:95, v/v) as the elution solution. A C(18) bonded silica column is used for chromatographic separation. The mobile phase consists of acetonitrile-water (85:15, v/v) containing 0.05% triethylamine at pH 2.5, adjusted with phosphoric acid with the flow-rate set at 1.0 mL/min. Using the fluorescence emission of closantel at lambda(ex) = 335 nm and lambda(ex) = 510 nm, the calibration curve is linear, with a correlation coefficient of 0.9999 over the concentration range of 10-5000 microg/kg for the tissue sample and 10-5000 microg/L for the milk sample. The detection limit (s/n = 3) is 3 microg/kg for tissue sample and 3 microg/L for milk sample. The intra- and inter-day repeatabilities are between 3.35-7.66% and 4.04-8.67%, respectively. The proposed method enables the quantitative determination of closantel residues at levels as low as 10 microg/kg in animal tissue samples and 10 microg/L in milk samples.  相似文献   

11.
A rapid and simple high-performance liquid chromatographic method with photodiode array detection was developed for the separation and the simultaneous determination of phenytoin and dextromethorphan in human urine. Analysis was performed in less than 4.5 min in isocratic mode on a reversed-phase C18 column (5 microm; 150 x 4.6 mm) using a mobile phase composed of acetonitrile-buffer phosphate 0.01 M (60:40, v/v) adjusted to pH 6.0, at 1 mL/min flow rate and UV absorbance at 210 nm. The elution order of analytes was dextromethorphan (DXM), Internal Standard (IS), and phenytoin (PHT). Calibration curves were linear in the 7.5-25 microg/mL range for PHT and in the 10-30 microg/mL range for DXM. Spike recoveries for urine samples prepared at three spiking levels ranged from 97.8 to 102.3% for PHT and from 94.8 to 100.4% for DXM. The detection limit (LOD) values ranged from 0.08 microg/mL for PHT to 0.5 microg/mL for DXM. The quantitation limit (LOQ) values ranged from 0.3 microg/mL for PHT to 1.6 microg/mL for DXM. The sample preparation method involves a rapid and simple procedure based on solid-phase extraction using a C18 reversed-phase column. Validation of the optimised method was carried out according to the ICH guidelines. The method developed in this study allows the reliable simultaneous analysis of PHT and DXM, drugs that were never quantified together in previously reported analytical methods. The described method has the advantage of being rapid and easy and it could be applied in therapeutic monitoring of these drugs in human urine of epileptic patients.  相似文献   

12.
A simple and sensitive high-performance liquid chromatography (HPLC) method is developed and validated for simultaneous determination of pantoprazole and its two metabolites (pantoprazole sulfone and pantoprazole thioether) in dog plasma and applied to a pharmacokinetic study in Beagle dogs. Following a protein precipitation procedure, the samples are separated using reversed-phase HPLC (C18) by a gradient of acetonitrile and ammonium acetate (pH 6.0) at a flow rate of 1.0 mL/min and quantitated using UV detection at 290 nm. Omeprazole is selected as the internal standard. The method has a lower limit of quantitation of 0.025 microg/mL for pantoprazole and its two metabolites, using 0.1-mL aliquots of plasma. The linear calibration curves are obtained in the concentration range of 0.025-10.0 microg/mL for three analytes. The intra- and interrun precision (relative standard deviation), calculated from quality control (QC) samples, is less than 13% for three analytes. The accuracy determined from QC samples is between -6.4% and 12%.  相似文献   

13.
A sensitive and simple HPLC method has been developed and validated for the determination of oxyresveratrol (trans-2,4,3',5'-tetrahydroxystilbene, OXY) and resveratrol (trans-3,5,4'-trihydroxystilbene, RES) in rat plasma. The plasma samples were extracted with ethyl acetate and analyzed using HPLC on an Aglient Zorbax SB-C(18) column (250 x 4.6 mm, 5 microm) at a wavelength 320 nm, with a linear gradient of (A) acetonitrile and (B) 0.5% aqueous acetic acid (v/v), at a flow rate of 1.0 mL/min. The method was linear over the range of 0.1265-25.3 microg/mL for OXY and 0.117-23.4 microg/mL for RES. The extraction recovery for OXY, RES and internal standard ranged from 71.1 to 88.3%. The intra- and inter-day precisions were better than 10%, and the accuracy ranged from 89 to 108%. The validated method was used to study the pharmacokinetic profiles of OXY and RES in rat plasma after oral administration of Smilax china root extract.  相似文献   

14.
A high-performance liquid chromatographic method was optimized and validated for the determination of atenolol and chlorthalidone (CT) in human breast milk. The milk samples were extracted and purified using ACN and phosphoric acid for precipitation of proteins followed by removal of ACN and milk fats by extraction with methylene chloride. The samples were applied, after an extraction procedure, to a cyanide column using a mobile phase consisting of ACN/water (35:65 v/v) and buffered at pH 4.0 with flow rate of 1.0 mL/min. Quantitation was achieved with UV detection at 225 nm using guaifenesin as the internal standard. The effectiveness of protein precipitation and clean up procedure were investigated. The method was validated over the range of 0.3-20 microg/mL for atenolol and 0.25-5 microg/mL for CT.  相似文献   

15.
A high-performance liquid chromatographic method with UV detection has been developed for the determination of saikosaponin a in rat plasma. Saikosaponin a and internal standard jujuboside A were isolated from plasma samples by solid-phase extraction. The chromatographic separation was achieved on a reversed-phase C(18) column with the mobile phase of acetonitrile-water (35:65, v/v) at a flow rate of 1 mL/min and UV detection was set at 205 nm. The standard curve for saikosaponin a was linear over the concentration range 0.25-10 microg/mL and the limit of detection was 0.05 microg/mL. The absolute recovery was greater than 82%. The precision and accuracy ranged from 3.05 to 9.59% and 95.61 to 110.00%, respectively. The validated method was used to determine saikosaponin a in plasma samples in a pharmacokinetic study of saikosaponin a administered to Sprague-Dawley rats.  相似文献   

16.
A simple, precise and accurate method is proposed for rapid determination of trace amounts of hydroxylamine based on the reaction of hydroxylamine with iodate in acidic media. The reaction of neutral red by the produced nitrite ion was used to monitor the reaction spectrophotometrically at 525 nm by a fixed time method. Hydroxylamine in the range of 0.0400-1.200 microg mL(-1) could be determined. The relative standard deviation for 10 determinations of 0.500 microg mL(-1) hydroxylamine was 1.81% and the limit of detection was 0.010 microg mL(-1). The proposed method was applied to the determination of hydroxylamine in water samples with satisfactory results.  相似文献   

17.
A method for quantitative determination of atractylenolide II in rat plasma using reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with UV spectrometry was established. From a variety of compounds and solvents tested, atractylenolide III was selected as the internal standard (IS) and ethyl acetate was found to be the best solvent for extracting atractylenolide II from plasma samples. RP-HPLC analysis of the extracts was performed on an analytical column (DIKMA ODS, 150 x 4.6 mm; i.d., 5 microm) equipped with a security guard pre-column system. There was good linearity over the range 0.05-5.0 microg/mL (r > 0.99). The recoveries were more than 90.0% in plasma, and the intra- and inter-day coefficients of variation were less than 10.0% in all cases. The limit of detection (LOD) was 0.025 microg/mL and the lower limit of quantification (LLOQ) was 0.05 microg/mL. The RP-HPLC method was applied to quantitate atractylenolide II in rat plasma within 24 h in a pharmacokinetics study where experimental rats received a single dose of atractylenolide II (60 mg/kg).  相似文献   

18.
A simple high-performance liquid chromatography method using a diode array detector (DAD) is developed for the simultaneous analysis of five major catechins: (+)-catechin (C), (-)-epicatechin (EC), (-)-gallocatechin (GCT), (-)-epigallocatechin (EGC), (-)-epigallocatechin gallate (EGCG), and the phenolic plant metabolites gallic acid (GA) and rutin (RT) in lyophilized extracts of Cistus species. The optimal analytical conditions are investigated to obtain the best resolution and the highest UV sensitivity for the quantitative detection of catechins. The optimized conditions (acetonitrile-phosphate buffer 50mM, pH 2.5, gradient elution system on a C(18) reversed-phase column with a flow rate of 1 mL/min and UV absorbance at 210 nm) allowed a specific and repeatable separation of the studied analytes to be achieved. All compounds are successfully separated within 32 min. Calibration curves are linear in the 2-50 microg/mL range for GCT, C, and EGCG and in the 5-50 microg/mL range for GA, EGC, EC, and RT. The limit of detection values ranged from 0.24 to 0.74 microg/mL. The limit of quantitation limit values ranged from 0.77 to 1.94 microg/mL. The validated method is applied to the determination of the specific phytochemical markers GA, GCT, C, and RT in Cistus incanus and Cistus monspeliensis lyophilised extracts. The recovery values ranged between 78.7% and 98.2%. The described HPLC method appears suitable for the differentiation and determination of the most common catechins together with the glycoside rutin and the phenolic compound gallic acid and can be considered an effective and alternative procedure for the analyses of this important class of natural compounds.  相似文献   

19.
A simple, accurate, precise and sensitive HPLC-UV method was developed for the determination of secnidazole in human plasma. Secnidazole and tinidazole (IS) were extracted from 0.2 mL of human plasma by ethyl acetate. Secnidazole was then separated by HPLC on a Diamond C(18) column and quantified by ultraviolet detection at 319 nm. The mobile phase consisted of acetonitrile-aqueous 5 mm sodium acetate (30:70, v/v) containing of 0.1% acetic acid adjusted to pH 4.0, and the flow rate was 1.0 mL/min. The low limit of quantification was 0.1 microg/mL. The method was linear over the concentration range 0.1-25.0 microg/mL (R(2) = 1.000). The recovery of secnidazole from human plasma ranged from 76.5 to 89.1%. Inter- and intra-assay precision ranged from 3.3 to 10.7%. Secnidazole in plasma was stable when stored at ambient temperature for 8 h, at -20 degrees C for 2 weeks and at -20 degrees C for three freeze-thaw cycles. The developed method was successfully applied to the pharmacokinetic and bioequivalence studies between test and reference secnidazole tablets following a single 500 mg oral dosage to 20 healthy volunteers of both genders. Pharmacokinetics parameters T(max), C(max), AUC(0-)t, AUC(0-infinity), T(1/2) were determined of both preparations. The analysis of variance (ANOVA) did not show any significant difference between the two preparations and 90% confidence intervals fell within the acceptable range for bioequivalence. It was concluded that the two secnidazole preparations are bioequivalence and may be used interchangeably.  相似文献   

20.
A high performance liquid chromatographic method (HPLC), together with solid phase extraction (SPE), was developed for simultaneous determination of albiflorin and paeoniflorin in rat urine after oral administration of Si-Wu decoction. The samples were pretreated with solid phase extraction using Extract-Cleantrade mark cartridges. Analysis of the extract was performed on a reversed-phase C18 column and a mobile phase made up of acetonitrile and 0.03% formic acid (17:83, v/v). UV detection was set at 230 nm. The assay was linear over the range 2.625-52.50 mg/mL for albiflorin and 3.875-77.50 microg/mL for paeoniflorin. The average percentage recoveries of three spiked urines were 97.01 +/- 3.32 and 102.32 +/- 6.97 for albiflorin and paeoniflorin, respectively. The intra-day precision (RSD) ranged from 0.21 to 1.79% at concentrations of 4.20, 10.50, 26.25 and 39.375 microg/mL of albiflorin and 0.12 to 2.92% at concentrations of 3.875, 10.85, 23.25 and 58.125 microg/mL of paeoniflorin, and inter-day precision (RSD) was from 1.02 to 1.86% for albiflorin and 0.94 to 3.30% for paeoniflorin, at the same four concentrations. This method was applied in order to analyze albiflorin and paeoniflorin in rat urine following oral administration of traditional Chinese medicinal preparation of Si-Wu decoction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号