首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, reliable, and rapid RP-LC method has been developed for the determination of some anticancer drugs (daunorubicin, doxorubicin and vincristine sulfate) in their dosage forms and human urine. These compounds are well separated on a C18 column using the mobile phase consisting of a mixture of acetonitrile (50:50; v/v) at a flow rate of 1.5 mL min?1. The analyte peaks were detected at 235 nm for doxorubicin and daunorubicin, and 220 nm for vincristine. Linearity was obtained in different concentration ranges between 0.10 and 12 μg mL?1 for all compounds. Good sensitivity for all analytes was observed with DAD detection. LOD and LOQ of the method were found satisfying. The proposed method has been extensively validated in accordance with ICH guidelines and obtained results proved that the proposed method was precise, accurate, selective, and sensitive for simultaneous analysis of studied compounds. All analytical procedures including sample preparation, flow rate, and run time were at low levels. Also, pK a values were determined using the dependence of the retention factor on the pH of the mobile phase. The effect of the mobile phase composition on the ionization constant was studied by measuring the pK a at different methanol–water mixtures, ranging between 45 and 60 % (v/v).  相似文献   

2.
The aim of the present study was to develop a fast, sensitive and reliable method for rapid screening of cephalosporin injectable dosage forms namely ceftazidime and ceftizoxime to the detection of counterfeit and substandard drugs that might be illegally commercialized. Ceftazidime, ceftizoxime and cefixime (IS) were separated in a X-Terra RP-18 column (250 × 4.60 mm ID × 5 ??) and DAD detector set at 290 and 260 nm. The mobile phase consisted of a mixture of methanol:water 20:80 (v/v) at a flow rate of 1.0 mL min?1. Additionally, in order to find the optimum pH value of separation the pK a values of studied compounds were determined by using two different methodologies. Aqueous pK a values of studied compounds have been determined by UV-spectrophotometry and liquid chromatography were used for the determination and direct characterization of the dissociation constants by using the dependence of the capacity factor on the pH of the mobile phase in 20% (v/v) methanol?Cwater binary mixture in which separation was performed. The pH of the mobile phase was adjusted with 25 mM H3PO4 to 3.2. The method was shown to be linear, sensible, accurate, and reproducible over the range of analysis and it can be used to pharmaceutical formulations containing a single active ingredient within a short analysis time.  相似文献   

3.
Bari  P. D.  Rote  A. R. 《Chromatographia》2009,69(11):1469-1472

Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min−1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot−1 for olmesartan and hydrochlorothiazide, respectively.

  相似文献   

4.
Patel  Sejal K.  Patel  Natavarlal J. 《Chromatographia》2009,69(3-4):393-396

A simple, sensitive, and precise thin layer chromatographic (TLC) method for simultaneous analysis of psychopharmacological drugs like amitriptyline HCl, trifluoperazine HCl, risperidone and alprazolam in their single dosage forms has been developed, validated, and used for determination of the compounds in commercial pharmaceutical products. The TLC separation was carried out on Merck TLC aluminium sheets of silica gel 60 F254 using carbon tetrachloride:acetone:triethylamine (8:2:0.3, v/v/v), as mobile phase. Densitometric measurements of their spots were achieved at 250 nm over the concentration range for amitriptyline HCl (50–1,200 ng spot−1), trifluoperazine HCl (50–1,200 ng spot−1), risperidone (100–2,400 ng spot−1) and alprazolam (25–600 ng spot−1). Limit of detection (LOD) for amitriptyline HCl (20 ng spot−1), trifluoperazine HCl (20 ng spot−1), risperidone (40 ng spot−1) and alprazolam (5 ng spot−1) was obtained. The study showed that TLC was sensitive and selective for determination of amitriptyline HCl, trifluoperazine HCl, risperidone and alprazolam using a single mobile phase. This proposed method is able for simultaneous determination of psychopharmacological drugs and also applicable for analysis of pharmaceutical formulations.

  相似文献   

5.
Dogan-Topal  B.  Uslu  B.  Ozkan  S. A. 《Chromatographia》2007,66(1):97-101

This paper describes the validation of an isocratic high-performance liquid chromatographic method for the assay of valganciclovir in raw materials, tablets and human serum samples. Valganciclovir and fluvastatin (internal standard) were well separated using a reversed phase column and a mobile phase consisting of a mixture of acetonitrile:methanol:KH2PO4 (0.02 M) (40:20:40; v/v/v) (at pH 5.0). The mobile phase was pumped at 1.0 mL min−1 flow rate and valganciclovir was detected by diode-array detection at 255 nm. The retention times for valganciclovir and fluvastatin were 3.41 and 5.60 min, respectively. A linear response (r > 0.999) was observed in the range of 10–30,000 ng mL−1 in mobile phase and serum. The limit of detection and limit of quantification were found as 2.95 and 9.82 ng mL−1 in mobile phase and 1.73 and 5.77 ng mL−1 in human serum samples, respectively. Validation parameters as precision, accuracy, selectivity, reproducibility and system suitability tests were also determined. The method can be used for valganciclovir assay of tablets and human serum samples as the method separates valganciclovir from tablet excipients and endogenous substances.

  相似文献   

6.

Bosentan monohydrate (4-tert-butyl-N-[6-(2-hydroxyethoxy)-5-(2-methoxyphenoxy)-2-(pyrimidin-2-yl) pyrimidin-4-yl]benzene-1-sulfonamide monohydrate) is a dual endothelin receptor antagonist (ERA) applied in the treatment of pulmonary arterial hypertension. To achieve effective process control of the bosentan monohydrate synthesis, it was necessary to develop a selective and not highly time-consuming method for ultra-high performance liquid chromatography (UHPLC). The method is characterized by adequate sensitivity, reproducibility and selectivity for the determination of bosentan monohydrate and related compounds from all synthetic stages. The UHPLC separation was carried out by reversed phase chromatography on the Acquity BEH C18 column (100 mm × 2.1 mm, 1.7 µm) with a mobile phase composed of solvent A (0.1 %, v/v, acetic acid in water) and solvent B (methanol), in the gradient mode at the flow rate of 0.4 mL min−1. Limits of detection and quantification for the compounds were ≤0.1 µg mL−1 and 0.3 µg mL−1, respectively. The linearity for all related compounds was investigated as in the range for the active pharmaceutical ingredient (API) and as in the range for the in-process control. The developed method was validated according to the current guidelines, proving the suitability of the method for its intended purpose.

  相似文献   

7.
Dogan-Topal  B.  Ozkan  S. A.  Uslu  B. 《Chromatographia》2007,66(1):25-30

A rapid, sensitive, and specific reverse phase high performance liquid chromatography with diode array detection procedure for the simultaneous determination of abacavir, efavirenz and valganciclovir in spiked human serum is described. Separation was performed on a 5 μm Waters Spherisorb column (250 × 4.6 mm ID) with acetonitrile: methanol:KH2PO4 (at pH 5.00) (40:20:40 v/v/v) isocratic elution at a flow rate of 1.0 mL min−1. Calibration curves were constructed in the range of 50–30,000 ng mL−1 for abacavir and efavirenz, and 10–30,000 ngmL−1 for valganciclovir in serum samples. The limit of detection and limit of quantification concentrations of the HPLC method were 3.80 and 12.68 ng mL−1 for abacavir, 2.61 and 8.69 ng mL−1 for efavirenz, 1.30 and 4.32 ng mL−1 for valganciclovir. The method has been applied, without any interference from excipients or endogenous substances, for the simultaneous determination of these three compounds in human serum.

  相似文献   

8.
Choi  Young Hee  Suh  Jung Hwa  Lee  Joo Hyun  Cho  Il Hwan  Lee  Chul Kyu  Lee  Myung Gull 《Chromatographia》2009,70(9-10):1435-1439

A simple, rapid, and reproducible reversed-phase LC method with UV detection at 215 nm has been developed for analysis of SP-8203 in rat samples. A C18 column was used with 3,000:1,050 (v/v) 0.01 m K2HPO4 buffer (pH 3)–acetonitrile as mobile phase at a flow rate of 1.7 mL min−1 at 50 °C. Samples were extracted with dichloromethane containing ondansetron (internal standard). Detection limits for SP-8203 in plasma, urine, and gastrointestinal tract samples were 0.05, 0.5, and 10 μg mL−1, respectively. The method was suitable for pharmacokinetic study of SP-8203 in rats after intravenous administration.

  相似文献   

9.
Ate&#;  Z.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):123-127

A simple method for the determination of carbamazepine and its active metabolite carbamazepine-10,11-epoxide by ultra performance liquid chromatography (UPLC) with ultraviolet absorbance detection (TUV) was developed. The method involves a two-step protein precipitation by liquid–liquid extraction. Phenytoin sodium was used as the internal standard. The separation was carried out on Acquity C18 column with acetonitrile:methanol:KH2PO4 buffer (adjusting pH to 4.6 with 85% o-phosphoric acid) (180/180/170, v/v/v) as the mobile phase at a flow rate of 0.4 mL min−1. Linear detection response was obtained for concentrations ranging from 50 to 5,000 ng mL−1. The limit of quantification (LOQ) was 50 ng mL−1. The method was validated successfully for the determination of carbamazepine and its active metabolite carbamazepine-10,11-epoxide, which can be applied through pharmacokinetics and bioequivalence studies.

  相似文献   

10.
The dissociation constant values (sspKa) of some carbapenem group drugs (ertapenem, meropenem, doripenem) in different percentages of methanol–water binary mixtures (18, 20 and 22%, v/v) were determined from the mobile phase pH dependence of their retention factor. Evaluation of these data was performed using the NLREG program. From calculated pKa values, the aqueous pKa values of these subtances were calculated by different approaches. Moreover, the correlation established between retention factor and the pH of the water–methanol mobile phase was used to determine the optimum separation conditions. In order to validate the optimized conditions, these drugs were studied in human urine. The chromatographic separation was realized using a Gemini NX C18 column (250 × 4.6 mm i.d., 5 µm particles) and UV detector set at 220 and 295 nm. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
Zou  Jian-Jun  Fan  Hong-Wei  Guo  Da-Qing  Li  Ying-Bin  Lin  Song  Zhu  Yu-Bing  Yu  Cui-Xia  Zhou  Jie  Liu  Jiang-Hui  Hu  Yun-Fang 《Chromatographia》2009,70(11):1581-1586

A sensitive and specific liquid chromatography-tandem-mass spectrometry method was developed and validated for the simultaneous determination of clopidogrel and its carboxylic acid metabolite (SR26334) in human plasma using nateglinide and pioglitazone as internal standards. Analytes were extracted from 0.50 mL of plasma using diethyl ether–n-hexane (4:1, v/v). Chromatographic separation was performed on a Teknokroma C18 column with a mobile phase of methanol–water (containing 0.1% formic acid) (80:20, v/v) at a flow rate of 0.20 mL min−1 within 5.6 min. Linearity was established over the concentration range of 0.005–5 ng mL−1 for clopidogrel and 20–2,500 ng mL−1 for SR26334. Intra- and inter-batch standard deviations were less than 9.2% and the accuracy of this assay was found to fall within an acceptable range ≤10.0%. The method was successfully applied to the therapeutic drug monitoring of clopidogrel.

  相似文献   

12.
Yang  Xiao-ming  Zhang  Xiu-li  Chen  Yong-chang  Liu  Fang 《Chromatographia》2009,69(5-6):593-596

A sensitive and simple LC method for the quantification of ginkgolic acids in mice plasma has been developed. Following acetonitrile deproteinization, samples were separated on a SinoChrom ODS-AP C18 column. The mobile phase was 3% (v/v) acetic acid water solution–methanol (8:92, v/v) at a flow rate of 1.0 mL min−1. Detection was at 310 nm. Calibration curve was linear over the range of 0.25–50 μg mL−1 with intra- and inter-day precisions (RSD%) of less than 9.5%. The extraction recovery ranged from 87.0 to 90.2% (RSD 2.4–6.4%) for ginkgolic acids. The method was successfully applied to the pharmacokinetic study of ginkgolic acids in mice after oral dosing of 1.0 g kg−1.

  相似文献   

13.
Wang  Jun  Lu  Ding-Qiang  Ling  Xiu-Quan  Wang  Jia-Li  Qiao  Hong-Qun  Ouyang  Ping-Kai 《Chromatographia》2009,69(5-6):561-566

A liquid chromatographic method was developed for the simultaneous quantification of four major active components in tobacco (Nicotiana tobaccum L.) wastes. Samples were extracted with 70% v/v aqueous methanol, four compounds including chlorogenic acid, cryptochlorogenic acid, neochlorogenic acid and caffeic acid were identified and determined by using LC coupled to electrospray tandem mass spectrometry and LC–UV method, respectively. Separation in LC–UV was on an Alltima C18 column (250 mm × 4.6 mm i.d.; 5 μm) with a mobile phase consisting acetonitrile: ammonium acetate buffer (pH 4.5) (5:95 v/v), at a flow rate of 1.0 mL min−1, detected at 327 nm. Four regression equations showed good linear relationships (r 2 > 0.999) between the peak area of each marker and concentration. The method has good repeatability and precision, the intra-day and inter-day RSD for both retention time and peak area was less than 1.0%. The recoveries, measured at three concentration levels, varied from 96.33 to 101.10%. The LOD (S/N = 3) and LOQ (S/N = 6) were less than 0.010 and 0.795 μg·mL−1, respectively. This assay was successfully applied to the determination of four active compounds in ten samples. The results indicated that the developed assay method was rapid, accurate, reliable and could be readily utilized as a quantitative analysis method for various of tobacco wastes.

  相似文献   

14.
&#;&#;leyen  E. A. &#;.  &#;zden  T.  &#;zilhan  S.  Toptan  S. 《Chromatographia》2007,66(1):109-113

A simple, rapid, sensitive and selective LC-MS method was developed and validated for quantification of fexofenadine in human plasma. The LC-MS system was operated under the positive electrospray ionisation mode (ESI). After liquid–liquid extraction, fexofenadine analysis was performed on a C18 column with a mobile phase of acetonitrile: 10 mM ammonium acetate: formic acid, 70:30:0.1 (v/v/v) at a flow rate of 1 mL min−1 by using loratadine as internal standard. The lower limit of quantitation was 3 ng mL−1 for fexofenadine. The assay precision ranged between 1.05 and 12.56% and accuracy ranged between 82.00 and 109.07%. The validated method was successfully used to analyze human plasma samples in bioequivalence studies.

  相似文献   

15.

A sensitive, specific and rapid high-performance liquid chromatography method was developed in an effort to quantify extremely low curcuminoid levels for the future transdermal experiments where the curcuminoids are incorporated with excipients such as microemulsion, liposomes, and micelles. The chromatographic separation was performed using a Symmetry® C18, 250 × 4.6 mm, 5-μm column, with a mobile phase composed of 5 mM acetonitrile:phosphoric acid (45:55, v/v) at a flow rate of 1.0 mL min−1, it was sensitive with a low limit of quantitation for curcuminoids (0.626 ng mL−1 for curcumin) and good linearity (r 2 ≥ 0.999) over the range 1–100 ng mL−1. All the validation data, such as accuracy and precision, were within the required limits from the ICH guideline. The assay method was successfully applied during forced degradation of curcuminoid solutions. The method retained its accuracy and precision when the standard addition technique was applied.

  相似文献   

16.
Fang  Lina  Wang  Qiudi  Bi  Kaishun  Zhao  Xu 《Chromatographia》2016,79(23):1659-1663

A sensitive and simple HPLC method for simultaneous determination of PAC-1 (first procaspase-activating compound), phenol red, and permeability markers (carbamazepine and furosemide) in perfusion samples was developed and validated to assess intestinal absorption of PAC-1 using single-pass intestinal perfusion technique (SPIP) in rats. The chromatographic separation was carried out on a Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with acetonitrile–methanol–30 mmol L−1 phosphate buffer (pH 3.0, 25:10:65, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1, and the wavelength of the UV detector was set at 281 nm. The calibration curves were linear in the ranges of 2.40–48.0 μg mL−1 for PAC-1; 3.60–72.0 μg mL−1 for carbamazepine; 3.20–64.0 μg mL−1 for furosemide, and 4.80–96.0 μg mL−1 for phenol red (r > 0.999). Both the intra- and inter-day precisions (RSD%) of all analytes were less than 6.8 % at three concentration levels, while accuracy ranged from 95.4 to 104.5 %. Data obtained in all method validation studies indicated that the method was suitable for the intended purpose. The effective permeability values (P eff) considering water flux with the help of non-permeable marker phenol red was calculated to be 0.42 × 10−4, 0.62 × 10−4, 0.32 × 10−4 cm s−1 for PAC-1; 0.72 × 10−4, 0.77 × 10−4, 0.52 × 10−4 cm s−1 for carbamazepine; 0.20 × 10−4, 0.16 × 10−4, 0.12 × 10−4 cm s−1 for furosemide in duodenum, jejunum and ileum, respectively. The P eff value can be increased by co-perfusion with verapamil, indicating that absorption of PAC-1 is efficiently transported by P-glycoprotein (P-gp) in the gut wall.

  相似文献   

17.
Deng  Weijie  Zhang  Xiangnian  Sun  Zhiping  Yin  Jilin  Zhou  Zheng  Han  Liping  Zhao  Shujin 《Chromatographia》2012,75(11):629-633

A new and simple high-performance liquid chromatography with evaporative light scattering detector method for the determination of Kryptofix 2.2.2 (K-222) in the radiopharmaceuticals of 2-deoxy-2-[18F]fluoro-d-glucose ([18F]FDG) and 3′-deoxy-3′-[18F]fluorothymidine ([18F]FLT) was developed. A C18 column was used and the mobile phase was 10 % (v/v) methanol and 90 % (v/v) water (0.1 % trifluoroacetic acid, v/v) at a flow rate of 0.2 mL min−1. The drift tube temperature was 40 °C. The pressure of nebulizing gas (N2) was 3.0 bar. The gain was 10. Good separation of K-222 from main related substances could be achieved. Excellent linearity (r 2 = 0.9995) was obtained over the range of 5–100 μg mL−1. The precision ranged from 0.68 to 5.16 % (RSD) and the accuracy ranged from −3.05 to 2.62 % (RE). The limit of detection was 2 μg mL−1. This method offers simple, rapid and quantitative detection of K-222, thus making it acceptable for routine determination.

  相似文献   

18.

A simple, sensitive and specific liquid chromatographic method with UV detection (228 nm) was developed for the simultaneous estimation of rosiglitazone and glimepride in human plasma. Rosiglitazone and glimepride were extracted from plasma using liquid–liquid extraction. Separation was achieved with an RP C18 Column using a mixture of phosphate buffer (50 mM) with octane sulfonic acid (10 mM), methanol and acetonitrile as a mobile phase (55:10:35, v/v). pH was adjusted to 7.0. Amlodipine was used as an internal standard (IS). LOD of the method was found to be 20 ng mL−1 for both drugs. Results were linear over the studied range 40.994–2007.556 ng mL−1 for rosiglitazone (r ≥ 0.99) and 41.066–2094.84 ng mL−1 for glimepride( r ≥ 0.99). The method was found to be simple, selective, precise and reproducible for the estimation of both drugs from spiked human plasma.

  相似文献   

19.
Maher  Hadir M.  Youssef  Rasha M. 《Chromatographia》2009,69(3-4):345-350

Two chromatographic methods have been described for the simultaneous determination of metronidazole (MET) and spiramycin (SPY) in their mixtures. The first method was based on a high performance thin layer chromatographic (HPTLC) separation of the two drugs followed by densitometric measurements of their spots at 240 nm. The separation was carried out on Merck TLC aluminum sheets of silica gel 60 F254 using methanol: chloroform (9:1, v/v) as a mobile phase. Analysis data was used for the linear regression line in the range of 1.0–2.0 and 0.8–2.0 μg band−1 for MET and SPY, respectively. The second method was based on a reversed-phase liquid chromatographic separation of the cited drugs on a C-18 column (5 μm, 250 × 4.6 mm, i.d.). The mobile phase consisted of a mixture of phosphate buffer of pH 2.4 and acetonitrile (70:30, v/v). The separation was carried out at ambient temperature with a flow rate of 1.0 mL min−1. Quantitation was achieved with UV detection at 232 nm based on peak area with linear calibration curves at concentration ranges 0.4–50.0 and 0.5–50.0 μg mL−1 for MET and SPY, respectively. The proposed chromatographic methods were successfully applied to the determination of the investigated drugs in pharmaceutical preparations. Both methods were validated in compliance with ICH guidelines; in terms of linearity, accuracy, precision, robustness, limits of detection and quantitation and other aspects of analytical validation.

  相似文献   

20.
Alberti  Agnes  Blazics  Balazs  Kery  Agnes 《Chromatographia》2008,67(1):107-111

A reversed-phase high-performance liquid chromatography method with UV detection was developed for determination of [(N-morpholine)methylene]daunorubicin hydrochloride (DD-M) during studies of its stability. In this LC method the following were used: an RP-column, the mobile phase—acetonitrile:methanol:solution A (9:1:10 v/v/v) [solution A contains 2.88 g of sodium laurilsulfate and 1.6 mL of phosphoric acid(V)] with a flow rate of 1.4 mol L−1 and quinine hydrochloride as an internal standard. The detection wavelength was 254 nm. The method was validated with regard to linearity, limit of detection, limit of quantitation, selectivity and precision. Hydrolysis of the DD-M catalyzed by hydrogen ions in hydrochloric acid and a spontaneous reaction of the DD-M degradation under the influence of the water in sodium hydroxide took place. The thermodynamic parameters of these reactions—energy, enthalpy and entropy of activation—were calculated. It was observed that a positive salt effect occurred in hydrochloric acid.