首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel membrane sensor for selective monitoring of iodide, consisting of a triiodide‐ketoconazole ion pair complex dispersed in a PVC matrix, plasticized with a mixture of 2‐nitrophenyl octyl ether and dioctylphtalate with unique selectivity toward iodide ions, is described. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The optimized membrane demonstrates a near‐Nernstian response for iodide ions over a wide linear range from 1.0 × 10?2 to 1.0 × 10?5 M, at 25 ± 1 °C. The electrode could be used over a wide pH range 3–10 and has the advantages of high selectivity, fast response time and good lifetime (over 4 months). It was successfully used as indicator electrode in potentiometric titrations and direct potentiometric assay of iodide ions.  相似文献   

2.
《Analytical letters》2012,45(8):1569-1578
Abstract

A nalbuphine ion‐selective PVC membrane electrode based on ion‐pair complex of nalbuphine with tetra phenyl borate was prepared with di‐butyl sebacate as a plasticizer. The electrode exhibits a linear response with a Nernstain slope 59.6 mV decate?1 at 25°C with the concentration range of 1×10?6?1×10?2 M nalbuphine. The electrode response was not sensitive to pH changes from 3.5–7 and not affected by possible interfering species such as common inorganic cations, sugars and amino‐acids. The electrode shows good stability, reproducibility and fast response. These characteristics of the electrode enable it to be used successfully for the determination of nalbuphine hydrochloride in pure form and in pharmaceutical preparations.  相似文献   

3.
Betamethasone sodium phosphate (BMNaP) has been employed as an electroactive material in the design of an ion-selective electrode (ISE). The electrode incorporates PVC membrane with betamethasone sodium phosphate-lidocaine ion pair complex. The influences of membrane composition, temperature, pH of the test solution, and the interfering ions on the electrode performance were investigated. The sensor exhibits a Nernstian response for betamethasone sodium phosphate ions over a relatively wide concentration range (1.0 × 10?1 to 1.0 × 10?5 M) with a slope of 28.4 ± 0.9 mV per decade at 25°C. It can be used in the pH range 4.0–10.0. The isothermal temperature coefficient of this electrode amounted to ?0.0008 V/°C. The membrane sensor was successfully applied to the determination of betamethasone sodium phosphate in pharmaceutical products.  相似文献   

4.
《Electroanalysis》2004,16(16):1330-1335
A poly(vinyl chloride) membrane sensor based on oxalic acid bis (cyclohexylidene hydrazide) as membrane carrier was prepared and investigated as a Cr(III)‐selective electrode. The electrode reveals a Nernstian behavior (slope 19.8±0.4 mV decade?1) over a wide Cr(III) ion concentration range 1.0×10?7–1.0×10?2 mol dm?3 with a very low limit of detection (i.e., down to 6.3×10?8 mol dm?3). The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 1.7–6.5. The electrode possesses advantage of very fast response, relatively long lifetime and especially good selectivity to wide variety of other cations. The sensor was used as an indicator electrode, in the potentiometric titration of chromium ion and in the determination of Cr(III) in waste water and alloy samples.  相似文献   

5.
《Electroanalysis》2004,16(4):282-288
Five recently synthesized macrocyclic diamides were investigated to characterize their ability as beryllium ion carriers in potentiometric PVC‐membrane electrodes. The electrodes based on 1,15‐diaza‐3,4;12,13‐dibenzo‐5,8,11‐trioxabicyclo[13,2,2] heptadecane‐2,14‐dione exhibited a Nernstian response for Be2+ ion over wide concentration ranges (from 3.0×10?6 to 3.0×10?2 M for polymeric membrane electrode, PME, and from 5.0×10?7 to 2.0×10?2 M for coated glassy carbon electrode, CGCE) and very low detection limits (2.0 ×10?6 M for PME and 4.0×10?7 M for (CGCE). The electrodes possess low resistances, fast responses, satisfactory reproducibilities and, most importantly, good selectivities relative to a variety of other common cations. The potentiometric response of the electrodes is independent of pH of test solution in the pH range of 4.0–7.5. The proposed sensors were used to determine beryllium ion in water samples.  相似文献   

6.
《Analytical letters》2012,45(6):870-880
Abstract

An ion-selective electrode (ISE) was developed for the rapid determination of pseudoephedrine hydrochloride (PSEHCl) in pharmaceutical preparations. The electrode incorporates a PVC membrane with a pseudoephedrine–phosphotungstate ion pair complex. The influences of membrane composition, temperature, pH of the test solution, and the interfering ions on the electrode performance were investigated. The sensor exhibits a Nernstian response for pseudoephedrine hydrochloride ions over a relatively wide concentration range (1.0 × 10?1 to 1.0 × 10?5 mol L?1) with a slope of 56.2 ± 0.5 mV per decade at 25°C. It can be used in the pH range 4.0–10.5. The isothermal temperature coefficient of this electrode amounted to 0.0009 V/°C. The membrane sensor was successfully applied to determination of PSEHCl in its tablets and syrup.  相似文献   

7.
《Analytical letters》2012,45(8):1596-1609
Abstract

An original highly selective and sensitive PVC membrane sensor, working as a Fe(III) ion selective electrode and using 4‐amino‐6‐methyl‐3‐methylmercapto‐1,2,4‐triazin‐5‐one (AMMTO) as an ionophore, has been developed. This cetain sensor demonstrated the following performance; a linear dynamic range between 1.0×10?6 and 1.0×10?1 M with a near Nernstian slope of 19.4±0.5 mV per decade; a detection limit of 6.8×10?7 M; characteristically, the best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 65.5% nitrophenyl octyl ether, 2% sodium tetraphenyl borate and 2.5% AMMTO. Furthermore, the potentiometric response of the developed electrode is independent of the solution pH in the range of 2.2–4.8. The sensor possesses the advantages of short conditioning time, fast response time (<15 s) and, especially, great selectivity towards transition and heavy metal ions and some mono, di‐ and trivalent cations. The electrode can be used for at least 9 weeks without any considerable potential divergence. It was effectively used as an indicator electrode in the potentiometric titration of Fe(III) ions with EDTA and the direct determination of Fe3+ in different water samples.  相似文献   

8.
A highly selective PVC‐membrane electrode based on 2,6‐diphenylpyrylium fluoroborate is presented. The electrode reveals a Nernstian potentiometric response for sulfate ion over a wide concentration range (5.0 × 10?6‐1.0 × 10?1 M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for sulfate over a wide variety of common organic and inorganic anions and could be used over a wide pH range (2.5–9.5). The detection limit of the sensor is 3.0 × 10?6 M. It was successfully applied to the direct determination of salbutamol, paramomycin tablets, and as an indicator electrode for potentiometric titration of sulfate ions with barium ions.  相似文献   

9.
In this work, a highly selective membrane triiodide sensor based on a new charge‐transfer complex of bis(2,4‐dimethoxybenzaldehyde)butane‐2,3‐dihydrazone with iodine (Iodide Charge Transfer complex: ICT) as membrane carrier is introduced. The influences of five different solvent mediators on sensitivity and selectivity of the proposed sensor were considered. The best performance was obtained with the membrane composition containing 30% poly (vinyl chloride), 63% DBP, 5% ICT and 2% HTAB. The electrode shows a Nernstian behavior over a very wide triiodide ion concentration range (1.0 × 10?7‐1.0 × 10?2 M), and a detection limit value of 8.0 × 10?8 M. The effect of pH on the potentiometric response of the sensor was also studied, and it was found that the response of the electrode is independent of the pH of the solution in the pH range of 4.0–10. The proposed sensor has a very fast response time (< 12 s), and good selectivities relative to a wide variety of common inorganic and organic anions, including iodide, acetate, bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, cyanide and thiocyanate. In fact the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for triiodide ion. The proposed membrane sensor can be used for at least 6 months without any divergence in the potentials. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

10.
《Analytical letters》2012,45(10):1863-1874
Abstract

A novel pilocarpinium ion selective membrane electrode is prepared, characterized and used in pharmaceutical analysis. The electrode system incorporates a PVC membrane with pilocarpine-reineckatc ion pair complex as an electroactive material. The electrode exhibits a fast near-Nernstian response for 10?1-4x10?5M pilocarpine over the pH range 4-6.5. The electrode displays a good selectivity for pilocarpine with respect to a number of foreign cations. Pilocarpine in various pharmaccutical preparations is determined either by direct potentiometry or potentiometric titration with NaTPB using the proposed sensor. Pilocarpinereineckate membrane is also used in a flow through sandwich cell as a detector for flow injection determination of pilocarpine. Results with an average recovery of 99% and a relative standard deviation of ± 0.3% are obtained. The data compare favorably with those obtained by the standard US Pharmacopeia method.  相似文献   

11.
《Analytical letters》2012,45(5):902-916
Abstract

A novel Pr(III) ion‐selective polyvinyl chloride (PVC) membrane sensor, based on N,N‐bis(α‐methylsalicylidene)diethylenetriamine (BMT) as a new ionophore, has been prepared and studied. The electrode showed good selectivity for Pr(III) ion with respect to most common cations, including alkali, alkaline earth, transition, and heavy metal ions. This electrode has a wide linear dynamic range from 1.0×10?6 to 1.0×10?2 M with a Nernstian slope of 19.8±0.2 mV per decade and a low detection limit of 6.5×10?7 M, in the pH range of 3.0–8.4, while response time was rapid (<15 s). As far as applications of the recommended sensor are concerned, first it was employed as an indicator electrode in the potentiometric titration of Pr(III) ions with EDTA. Second, it was effectively applied to the determination of concentration of Pr(III) ions in soil and sediment samples, and validation with CRMs.  相似文献   

12.
《Electroanalysis》2002,14(23):1621-1628
Copper phthalocyanine was used as ion carrier for preparing polymeric membrane selective sensor for detection of iodide. The electrode was prepared by incorporating the ionophore into plasticized poly(vinyl chloride) (PVC) membrane, coated on the surface of graphite electrode. This novel electrode shows high selectivity for iodide with respect to many common inorganic and organic anions. The effects of membrane composition, pH and the influence of lipophilic cationic and anionic additives and also nature of plasticizer on the response characteristics of the electrode were investigated. A calibration plot with near‐Nernestian slope for iodide was observed over a wide linear range of five decades of concentration (5×10?6?1×10?1 M). The electrode has a fast response time, and micro‐molar detection limit (ca. 1×10?6 M iodide) and could be used over a wide pH range of 3.0–8.0. Application of the electrode to the potentiometric titration of iodide ion with silver nitrate is reported. This sensor is used for determination of the minute amounts of iodide in lake water samples.  相似文献   

13.
《Electroanalysis》2005,17(24):2260-2265
A new Cu(II) ion‐selective PVC membrane sensor based on 6‐methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one (MATTO) as an excellent sensing material was developed. The electrode exhibits a Nernstian slope of 29.2±0.4 mV per decade over a very wide concentration range between 1.0×10?1 and 1.0×10?6 M, with a detection limit of 4.8×10?7 M (30.5 ng/mL). The sensor possesses the advantages of short conditioning time, fast response time (<10 s), and especially, very good selectivity towards transition and heavy metal, and some mono, di and trivalent cations. The proposed electrode was successfully applied to the determination of copper in wastewater of copper electroplating samples and as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA.  相似文献   

14.
The sufficient amounts of bis(salicylaldehyde) thiocarbohydrazone (STCH) as a lipophilic selective element (3%, w/w), sodium nitrobenzene (NB) as a plasticizer (64%, w/w), tetraphenyl borate (NaTPB) as an anionic additive (3%, w/w), and poly vinyl chloride (PVC) as a polymeric matrix (30%, w/w) was employed to form a PVC membrane of a new Pr3+ ions selective sensor to apply as an indicator electrode in analytical applications. The best electrode response was observed in the slope (19.5 ± 0.7 mV per decade) over a wide concentrations from lower (1.0 × 10?6 mol L–1) to higher (1.0 × 10?2 mol L–1) of Pr3+ ion solution with a detection limit of 8.5 × 10–7 mol L–1. This electrode showed the fast response time about 10 second for praseodymium ion concentration range of 1.0 × 10–6 to 1.0 × 10–2 mol L–1, in the pH range of 2.3–7.9. The matched potential method was applied to study the selectivity of electrode toward Pr3+ ions in comparison with many common cations. The results showed the negligible disturbance of all other cations on the proposed praseodymium(III) electrode. The making sensor has been employed successfully as an indicator electrode in the potentiometric titration of praseodymium(III) solution with EDTA at pH 6.0. Moreover the applicability of the sensor was studied in determination of Pr3+ ion in mixtures of different ions.  相似文献   

15.
2,5-Dioxo-4-imidazolidinyl was used as an excellent sensing material in the preparation of a PVC membrane for a Ce(III)-selective sensor. The electrode shows a good selectivity for the Ce(III) ion with respect to most common cations including alkali, alkaline earth, transition, and heavy metal ions. The developed sensor exhibits a wide linear response with a slope of 19.6?±?0.3 mV per decade over the concentration range of 1.0?×?10?6 to 1.0?×?10?1 M, while the illustrated detection limit is 5.7?×?10?7 M of Ce(III) ions. Moreover, it is concluded that the sensor response is pH-independent in the range of 3.1–9.8. The applications of the recommended electrode include the determination of concentration of Ce(III) ions in soil and sediment samples, validation with CRM's, and the Ce(III) ion potentiometric titration with EDTA as an indicator electrode.  相似文献   

16.
《Analytical letters》2012,45(3):495-506
Abstract

A Dy(III) ion‐selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrix membrane containing a new asymmetrical Schiff's base [(E)‐N‐(2‐hydroxybenzylidene)benzohydraide] or BBH as a neutral carrier, sodium tetraphenyl borate (NaTPB) as an anionic excluder and nitrobenzene (NB) as a plasticizing solvent mediator. The membrane sensor displays linear potential response in the concentration range of 1.0×10?2–1.0×10?6 M of Dy(III). The electrode exhibits a nice Nernstian slope of 20.1±0.8 mV/decade in the pH range of 3.0–8.0. The sensor has a relatively short response time in whole concentration ranges (<20 s). The detection limit of the proposed sensor is 8.0×10?7 M (~128 ng/mL), and it can be used over a period of six weeks. The selectivity of the proposed sensor with respect to other cations, (alkali, alkaline earth, transition and heavy metal ions) and especially lanthanid ions, is excellent. The practical utility of the sensor has been demonstrated by using it as an indicator electrode in the potentiometric titration of Dy(III) with EDTA.  相似文献   

17.
Amr L. Saber 《Electroanalysis》2010,22(24):2997-3002
Simple, selective and accurate sensors were developed for the determination of melatonin and oxomemazine in biological samples (urine) and in pharmaceutical preparations. Potentiometric measurements were based on bismus tetraiodate‐drug ion‐pair as novel electroactive materials incorporating a plasticized PVC membrane with o‐nitrophenyl octyl ether or dioctyl phthalate. Each sensor was conditioned for at least two days in 0.1 M drug solution before use. It exhibited fast and stable Nernstian response for melatonin and oxomemazine over the concentration range of 1.0×10?6–1.0×10?2 M and 1.0×10?5–1.0×10?2 M, pH range of 3.0–6.5 and 3.5–6.0 for melatonin and oxomemazine sensors, respectively. Results with an average recovery not more than 101 % and a mean standard deviation less than 1.0 % of the nominal were obtained for the four sensors. The sensors showed reasonable selectivity towards investigated drugs in presence of many cations.  相似文献   

18.
《Electroanalysis》2003,15(12):1038-1042
A novel gadolinium ion‐selective electrode based on the antibiotic omeprazole as membrane carrier was prepared. The electrode has a linear dynamic range between 1.0×10?1 and 1.0×10?5 M, with a Nernstian slope of 19.3 ± 0.3 mV decade?1 and a detection limit of 5.0×10?6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0–10.0. The electrode possesses the advantages of short conditioning time, fast response time and especially, very good selectivity over a large number of other cations. The electrode can be used for at least 2 months without any considerable divergence in potentials. It was used as an indicator electrode in potentiometric titration of Gd(III) ions with EDTA.  相似文献   

19.
A new podand of 1,1′‐thia‐bis‐[1‐(chloroethan‐2‐acetamid‐α‐oxy)] naphtol was synthesized and used as a suitable carrier for Ag+ PVC membrane electrode. The electrode exhibited linear response with a Nernstian slope of (59.5±0.8 mV/decade) within a wide concentration range of 1.0×10?7 to 1.5×10?2 mol L?1 silver ions. The electrode had a fast response time of <10 s and detection limit of 8.6×10?8 mol L?1 with a working pH range from 3.7 to 9.0. The electrode was highly selective for Ag(I) ions over a large number of cations such as alkali, alkaline earth, and heavy metal ions. The proposed sensor has been applied as an indicator electrode for indirect determination of vitamin B1 in tablets by determination of Cl? ions in this compound with a standard solution of Ag(NO3).  相似文献   

20.
《Electroanalysis》2004,16(11):922-927
A novel chloride PVC‐based membrane sensor based on a ruthenium(III) Schiff's base complex, as an excellent neutral carrier, has been developed. The ruthenium complex, in combination with a ketonic plasticizer and a cationic additive led to ISEs with fundamental characteristics, such as slope sensitivity, short response times and selectivity coefficients, which were sufficient for practical applications. The sensor with composition of 30% PVC, 62% benzyl acetate, 5% ruthenium(III) Schiff's base complex and 3% hexadecyltrimethyl ammonium bromide displays near‐Nernstian behavior in a wide concentration range (1.0×10?1–3.0×10?6 M with slope of ?54.5±0.5) with a detection limit of 2.0×10?6 M (71.0 ng per mL). The response of the electrode is independent on pH in the range of 4.0–10.0 and can it be used for at least ten weeks. The proposed electrode shows a very short response time (<20 s) in whole concentration range. The sensor displays high selectivity toward chloride ions over several organic and inorganic anions. It was successfully applied for the determination of chloride in serum samples. It was also used as an indicator electrode in the potentiometric titration of chloride ions with silver nitrate solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏