共查询到20条相似文献,搜索用时 59 毫秒
1.
We have developed a novel, high-throughput approach for molecular mass determination of proteins from 14 200 to 116 000 based upon multiplexed, absorbance-based capillary electrophoresis. Via capillary multiplexing, 96 samples were analyzed simultaneously within 30 min. Detection with ultraviolet light obviates the need for protein staining or derivatization. The detection limit of the system was estimated at 5 microg/ml bovine serum albumin (BSA) when sampled from 12.5 mM Tris-HCl. The linear dynamic range was over two orders of magnitude from 5 microg/ml to 1000 microg/ml for BSA. Better than 5% sizing accuracy for protein molecular mass determination and excellent run-to-run and day-to-day reproducibility was obtainable with the described method. 相似文献
2.
Routine genetic analysis of large numbers of individuals by polymerase chain reaction (PCR) using capillary electrophoresis is often restricted by the low throughput of standard protocols and the tedious sample preparation process. Here, we demonstrate that capillary electrophoresis with UV detection can be used in PCR-based DNA analysis starting from clinical samples without purification or complicated sample manipulation. After PCR reaction using cheek cells, blood, or HIV-1 gag DNA, the reaction mixtures were injected into a capillary array either on-line or off-line by base stacking. The use of multiplexed absorption detection and the elimination of any purification steps both before and after PCR reaction can potentially provide significant benefits compared to current methods for DNA analysis with regard to time, cost, and labor. 相似文献
3.
Ren J 《Combinatorial chemistry & high throughput screening》2000,3(1):11-25
Genetic mutations/polymorphisms analyses play a great role in genetic and medical research, and clinical diagnosis. Most conventional methods for genetic assay are based on slab gel electrophoresis that is both labor-intensive and time-consuming. Recently, capillary electrophoresis (CE) has been used for genetic analysis instead of conventional slab gel electrophoresis. This technique can be automated and is characterized by short analysis time, small sample and reagents requirements, and high separation efficiency. CE has been successfully applied for mutation detection involving human tumor suppressor genes, oncogenes and disease-causing genes, and has shown a great potential for genetic mutation/polymorphism screening of large numbers of clinical samples. In this article, an overview of the fundamental aspects of mutation/polymorphism assay methods in combination with CE is given and some key applications are summarized. 相似文献
4.
On-line concentration of trace proteins by pH junctions in capillary electrophoresis with UV absorption detection 总被引:1,自引:0,他引:1
Hydroxylamine is a key raw material used in a synthetic drug process at Pharmacia. Since hydroxylamine is harmful to microorganisms, concentrations above 5 ppm could interfere with the biological sewage plant performance. This necessitated the development of a sensitive analytical method for detecting low levels of hydroxylamine in the waste streams generated from the pharmaceutical process. The present report describes a cation-exchange chromatographic method coupled with pulsed amperometric detection at a gold electrode for trace analysis of hydroxylamine. This method was evaluated by generating data on the parameters of specificity, precision, linearity, recovery and sensitivity. 相似文献
5.
A Gavenda J Sevcík J Psotová P Bednár P Barták P Adamovsky V Simánek 《Electrophoresis》2001,22(13):2782-2785
Sweeping preconcentration and electrokinetic injection was used for the capillary electrophoretic analysis of trace amounts of biologically active anthracyclines with UV absorption detection. Phosphate buffer (100 mM), pH 2.5, with addition of 40% v/v methanol was used as background electrolyte (BGE). Sodium dodecyl sulfate (150 mM) was added to BGE in the inlet vial as the sweeping agent. The system enables effective separation of anthracyclines as well as cleanup from matrix impurities. Sweeping preconcentration of sample provides an excellent detection limit (1 x 10(-9) mol L(-1)). The method was applied for the determination of therapeutic levels of doxorubicin in real plasma samples. 相似文献
6.
X. Xu P. C. A. M. de Bruyn J. A. de Koeijer H. Logtenberg 《Journal of chromatography. A》1999,830(2):186-451
A method for low-molecular-mass anion screening is described using a buffer composed of 5-sulfosalicylate (SS) as a visualizing ion, hexadimethrine bromide as an electroosmotic flow modifier and Tris as a pH buffer component, at pH 8.6. All ions with effective mobility higher than 2610−9 m2 s−1 V−1 can be separated within 7.5 min under −30 kV. By using the moderately mobile SS (5410−9 m2 s−1 V−1), not only the sensitivity of the detection is improved due to its high UV absorptivity, but also a smaller overall overloading effect is achieved. Meanwhile, the resolution of the high mobility ions, which is normally critical, remains almost the same as compared to a chromate buffer. With an electrokinetic injection, the limit of detection (LOD) of the common ions is 2–13 nM and the detection range is linear up to 0.5–3 μM. With a hydrostatic injection the LOD is 0.15–1 μM and the detection range is linear up to 25–200 μM. The identification of ions is performed by comparing the mobility of the ions with that of standards, taking the apparent and effective mobility of HCO3−, which is normally present in the sample solution, as a reference. 相似文献
7.
Capillary electrophoresis (CE) has attracted lots of attention due to its simplicity, low sample consumption, low solvent volume, high resolution, and high speed. Based on these advantages, it has been widely used in enzyme inhibitor screening. There are two main operation modes on enzyme inhibitor screening: off‐line (precapillary enzyme assays) in which process CE was used as an analytical tool; online (in‐capillary enzyme assays) which combined the sample injection, mix, reaction, separation, and detection within a single run. Additionally, diverse of new materials were introduced to immobilize enzyme, which has been coupled with CE for the study of enzyme activity and its inhibitor screening. This review gives an overview of the developments and applications for the CE‐based enzyme inhibitor screening. 相似文献
8.
P. Morin M. B. Amran S. Favier R. Heimburger M. Leroy 《Fresenius' Journal of Analytical Chemistry》1992,342(4-5):357-362
Summary Capillary zone electrophoresis (CZE) in capillary silica columns has been used for the separation of arsenite (AsO
2
–
), arsenate (AsO
4
3–
), monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA). The separation of these ionic species has been achieved using a capillary silica column (72 cm×50 m i.d.) with an acidic phosphate buffer and with an on-column UV detection (190 nm). Optimization of experimental parameters (pH, temperature, voltage) were studied. The selectivity of the separation can be improved by working in the pH-range of 4.5–6.5. For analytical inorganic separations of UV-absorbing anions, capillary zone electrophoresis has advantages because of the relatively simple equipment, the short analysis time (15 min), the high efficiency and the low mass detection limit (40 pg for arsenate). 相似文献
9.
Dynamic ligand exchange-affinity capillary electrophoresis (DLE-ACE) is introduced as a convenient platform for assessing the conformational stability and relative affinity of a holoprotein to different ligands without off-line sample pretreatment, since ligand exchange and protein unfolding processes are integrated in-capillary during electromigration. 相似文献
10.
Atha DH Miller K Sanow AD Xu J Hess JL Wu OC Wang W Srivastava S Highsmith WE 《Electrophoresis》2003,24(1-2):109-114
The enzyme telomerase is expressed in (85-90)% of all human cancers, but not in normal, non-stem cell somatic tissues. Clinical assays for telomerase in easily obtained body fluids would have great utility as noninvasive, cost-effective methods for the early detection of cancer. The most commonly used method for the detection and quantification of telomerase enzyme activity is the polymerase chain reaction (PCR)-based assay known as the telomerase repeat amplification protocol or TRAP assay. Most of the TRAP assay systems use a slab-gel based electrophoresis system to size and quantify the PCR-amplified extension products. We are developing high-throughput capillary electrophoresis (CE) methods for the analysis of TRAP/PCR products. The TRAP assay was conducted on lysates of the human lung cancer cell line A-549 in reactions containing 5-100 cells. TRAP/PCR products were generated using a fluorescent 4,7,2'4'5'7',-hexachloro-6-carboxyfluorescein(HEX)-labeled TS primer and analyzed on the Applied Biosystems Model 310 CE system using POP4 polymer. After analysis with GeneScan and Genotyper software, the total peak areas of the TRAP ladder extension products were computed using Microsoft Excel. Results were compared with unlabeled TRAP/PCR products analyzed on the Bio-Rad BioFocus 3000 CE system using 6% high molecular weight polyvinylpyrrolidone (HMW PVP) polymer and SYBR Green I dye. Both CE systems were able to resolve the TRAP ladder products with high reproducibility and sensitivity (5-15 cells). With the appropriate robotic sample handling system, these CE methods would enable performing the telomerase TRAP assay with increased sensitivity, reproducibility and automation over slab-gel methods. 相似文献
11.
J. Aupiais 《Chromatographia》1997,44(5-6):303-312
Summary The indirect UV detection of cations by capillary zone electrophoresis gives peaks of very different height or area between
cations. We show that the height depends on the electrophoretic mobility of the cation compared with the electrophoretic mobility
of the chromophore used. Moreover, the limit of detection can be easily improved by about 4-fold by adjusting the concentration
of complexing agent or by using a chromophore with the same velocity as the studied cation. Using a new parameter termedsensitization power we can optimize the limit of detection and have determined the best chromophores for each family of cations.Sensitization power is a maximum for: alkali metals and alkali earths with imidazole and UV Cat 2?, for transition metal with pyridine, for light rare earth with ephedrine and UV Cat 1?, for heavy lanthanides with 1-naphthylamine and phenyl-trimethyl-ammonium bromide. Corrected areas of all cations studied
have normal distributions directly proportional to their ionic charge. Certain behaviour can be predicted for elements such
as actinides. Detection can also be enhanced because the relation of proportionality between ionic charge and corrected area
allows comparison of the performance of all chromophores. 相似文献
12.
A method for the separation and direct detection of peroxynitrite (ONOO(-)) and two of its degradation products, nitrite (NO(2)(-)) and nitrate (NO(3)(-)), using capillary electrophoresis with ultraviolet detection is described. The separation parameters were optimized and included electrokinetic injection, a run buffer consisting of 25 mM K(2)HPO(4) 7.5 mM DTAB, pH 12, and a field strength of -323 V/cm. A diode array UV detector was employed in these studies as it allowed the determination of all three species simultaneously. Nitrate and nitrite provided the maximum response at 214 nm while peroxynitrite generated the best response at 302 nm. All three species could be detected at 214 nm, while simultaneous detection at 214 and 302 nm positively identified each peak. 相似文献
13.
A capillary electrophoretic method with UV detection for separation and quantitation of perfluorocarboxylic acids (PFCAs) from C6-PFCA to C12-PFCA has been developed. The optimization of measurement conditions included the choice of the most appropriate type and concentration of buffer in the background electrolyte (BGE), as well as the type and the content of an organic modifier. The optimal separation of investigated PFCAs was achieved with 50 mM phosphate buffer and 40% isopropanol in the BGE using direct UV detection. The optimum wavelength for direct UV detection was optimized at 190 nm. For indirect detection, several chromophores were studied. Five mM 3,5-Dinitrobenzoic acid (3,5-DNBA) in 20 mM phosphate buffer BGE and indirect UV detection at 280 nm gave the optimal detection and separation performance for the investigated PFCAs. The possibility of on-line preconcentration of solutes by stacking has been examined for indirect detection. The detection limits (LODs) determined for direct UV detection ranged from 2 microg/mL for C6-PFCA to 33 microg/mL for C12-PFCA. The LODs obtained for indirect UV detection were comparable to those obtained for direct UV detection. 相似文献
14.
Separation and direct UV detection of lanthanides complexed with cupferron by capillary electrophoresis 总被引:1,自引:0,他引:1
Separation and detection of lanthanides by capillary zone electrophoresis in the presence of cupferron (N-nitroso-N-phenylhydroxylamine) as UV absorbing complexing agent were investigated. The resolution of partially complexed positively charged cupferron complexes is improved by using a buffer ligand competing with cupferron for metal ions. When hydroxyisobutyric acid (HIBA) is used as buffer and competing ligand, it provides complete separation of all 14 lanthanides with good peak shapes. An on-column separation of 14 lanthanides was achieved in only 7 min using 0.1 mmol/l cupferron, 15 mmol/1 HIBA at pH 4.9. The separation efficiencies for the optimum separation condition are between 77,000 and 208,000 theoretical plates. Determination of lanthanide complexes was performed by direct UV detection at 210 nm. Detection limits (signal-to-noise ratio=3) are ca. 0.24-0.47 microg/ml for lanthanides. Under optimum conditions, the complete separation of thorium and uranium from mixed lanthanides was achieved. 相似文献
15.
A method was established using capillary electrophoresis with indirect UV detection for analysis of monosaccharides liberated from exopolysaccharides by acidic hydrolysis. Tangential flow filtration was used to isolate high molecular weight polysaccharides from seawater. The capillary electrophoresis method included the use of a background electrolyte consisting of 2,6-dimethoxyphenol and cetyltrimethylammonium bromide. Several neutral sugars commonly existing in marine polysaccharides were separated under optimized conditions. The relative standard deviations were between 1.3% and 2.3% for relative migration time and 1.3-2.5% for peak height. Detection limits (at S/N 3) were in the range of 27.2-47.8 μM. The proposed approach was applied to the analysis of hydrolyzed colloidal polysaccharides in seawater collected from the Baltic Sea. Nanomolar levels of liberated monosaccharides in seawater samples can be detected by preconcentration up to 30,000 times. 相似文献
16.
17.
18.
Rapid screening of aminopeptidase N inhibitors by capillary electrophoresis with electrophoretically mediated microanalysis 下载免费PDF全文
In this work, an electrophoretically mediated microanalysis (EMMA) method with a partial‐filling technique was setup to evaluate the inhibitory potency of novel compounds toward aminopeptidase N (APN). It was necessary to optimize the electrophoretic conditions with respect to the kinetic constraints and for attaining high sensitivity. In our setup, a part of the capillary was filled with the incubation buffer for the enzyme reaction, whereas the rest was filled with a suitable BGE for the separation of substrates and products. To monitor the performance of the newly developed method, the kinetic constants (Km and Vmax) for the catalyzed dissociation of l ‐Leucine‐p‐nitroanilide in the presence of APN as well as the inhibition constant (IC50) of a known competitive inhibitor, that is bestatin, were determined and these results were compared with those obtained by a classical spectrophotometric assay. The developed EMMA method was subsequently applied to the screening of 30 APN inhibitors. Whereas the inhibition potency of these inhibitors (expressed in IC50 values) were significantly underestimated by the EMMA method, the order of the inhibitory potential of these various compounds was found in agreement with the literature. 相似文献
19.
Direct determination of sialic acids in serum by capillary electrophoresis with UV detection 总被引:1,自引:0,他引:1
Summary A novel method for the determination of N-acetylneuraminic acid (NANA) and N-glycolylneuraminic acid (NGNA) has been developed
using high-performance capillary electrophoresis with UV detection at 195 nm, without pre or post-column derivatisation. The
acids were separated in a 50-cm, fused-silica capillary (50μ i.d, 45.5-cm effective length) with Na2B4O7−Na2HPO4 buffer. The detection limit for NANA is a concentration of 9.6×10−6 M or, in terms of mass:3.879×10−14 mol (39 fmol). This method is applicable to determination of NANA in normal human serum. The results were also compared with
those of the colorimetrie method. 相似文献
20.
Summary A capillary electrophoretic method has been developed for determination of the components of the paromomycin mixture salt.
Paromomycin was detected at 330 nm after pre-capillary derivatization witho-phthaldialdehyde and thioglycolic acid. The electrophoretic separation was performed in a fused-silica capillary at 25°C
and 18kV with a background electrolyte comprising 40mm sodium tetraborate, 3mm β-cyclodextrin, and 12.5% (v/v) methanol. Although the analysis time was reduced to 10min, five peaks could be separated
to baseline. The relative standard deviation of the ratios (peak area/internal standard peak area) was <5% for all peaks. 相似文献