首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two GC-MS methods, based on the application of N,O-bis(trimethylsilyl)trifluoroacetamide-derivatization-GC-MS (selected-ion monitoring) and GC-MS-MS without derivatization, respectively, were optimised and applied to the determination of a group of five selected endocrine disrupting compounds (EDCs) in wastewaters. Both methods included solid-phase extraction with Oasis HLB cartridges allowing an enrichment factor for wastewater samples of 100-fold. The investigated EDCs were estrone, 17beta-estradiol, 17alpha-ethynylestradiol, 4-tert-octylphenol and bisphenol A. Results obtained from the validation studies yielded comparable results in both cases. Recoveries in spiked wastewaters at 50 ng/l were higher than 90% for all the compounds, except for 4-tert-octylphenol (75%). Repeatability and reproducibility were adequate, varying from 1.6 to 14%, except for estrone which reproducibility was 28% when the derivatization-GC-MS method was applied. Limits of detection calculated ranged from 2.5 to 27.5 ng/l with differences between both methods from 1.1 (estrone) to 10.4 (bisphenol A) times. Both methods were successfully applied to the analysis of the target compounds in sewage treatment plant influents and effluents. Traces of bisphenol A, 4-tert-octylphenol, estrone and 17beta-estradiol were detected at concentration levels ranging from 13.3 to 1105.2 ng/l.  相似文献   

2.
A new analytical method for the simultaneous determination of two natural hormones (progesterone and estrone) and two selected endocrine disrupter compounds (EDCs) (diltiazem and carbamazepine (Cbz)) was developed by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) after pre-concentration with solid phase extraction (SPE). Influent and effluent samples taken from five different wastewater treatment plants throughout Turkey namely Hurma/Antalya, Lara/Antalya, Kemer-1 and Kemer-2 and METU/Ankara were analyzed for their EDCs contents under the optimum conditions. All of the parameters in the pre-concentration step were optimized and the best recoveries for all compounds of interest were achieved at pH 7 (about 100%). Progesterone was not detected in any of the treatment plants while diltiazem was found in all samples with the exception of Lara effluent.  相似文献   

3.
This paper describes the development and validation of a GC-MS method which allows the simultaneous quantification of 11 endocrine disrupting compounds (EDCs) in surface water samples from both estuary and sea. The analysed EDCs are oestrone (E1), 17β-estradiol (E2), 17α-ethynylestradiol (EE2), 4-tert-octylphenol, 4-n-octylphenol, 4-nonylphenol, bisphenol A and finally, mono and diethoxylates of 4-nonylphenol and 4-octylphenol. The method includes the pre-concentration of water samples, 1000-fold factor, in OASIS HLB cartridges by solid phase extraction, the derivatisation of all EDCs by N,O-bis(trimethylsilyl)trifluoroacetamide added with 1% trimethylchlorosilane and pyridine (at 65°C for 30?min) and, finally the stabilisation of the EDCs-silylated derivatives, in hexane, for 72?h. The validation parameters revealed that this method was highly specific for all target compounds using real samples. The linearity of the calibration curves (r 2) showed correlation factors higher than 0.990. The detection limits ranged from 0.10 to 1.45?ng?L?1, depending on each analysed compound, and recoveries were satisfactory for most of the assayed EDCs (>60%). Analysis of samples from four polluted areas of Douro River estuary and from two points of the Atlantic Ocean (Portugal) showed high amounts of E1 (up to 1.96?ng?L?1), E2 (up to 14.36?ng?L?1) and EE2 (up to 2.76?ng?L?1).  相似文献   

4.
A solid-phase extraction (SPE)-gas chromatography (GC)-mass spectrometry (MS) analytical method for the simultaneous separation and determination of endocrine disrupting chemicals (EDCs) from water samples is described in detail. Important and contrasting EDCs including estrone, 17beta-estradiol, 17beta-ethynylestradiol, 16beta-hydroxyestrone, 4-nonylphenol, bisphenol A and 4-tert-octylphenol were selected as the target compounds. The SPE technique, followed by the derivatisation with bis (trimethylsilyl) trifluoroacetamide was used for the extraction recoveries of target compounds from water samples. A number of parameters that may affect the recovery of EDCs, such as the type of SPE cartridges, eluents, as well as water properties including pH value, and concentration of salts and humic substances were investigated. It is shown that the Oasis cartridges produced the best recoveries of target EDCs while ethyl acetate was efficient in eluting EDCs from SPE cartridges. The recovery of some EDCs was enhanced by the addition of salt, but reduced by the increase in pH value and humic acid concentration. The optimised method was further verified by performing spiking experiments in natural river water and seawater matrices, with good recovery and reproducibility for all the selected compounds. The established method was successfully applied to environmental water samples from East and West Sussex, UK, for the determination of the target EDCs.  相似文献   

5.
Chemotherapeutics are pharmaceutical compounds the occurrence of which in the environment is of growing concern because of the increase in treatments against cancer diseases. They can reach the aquatic ecosystems after passing through wastewater treatment plants without complete removal. One of the most frequently used chemotherapeutics is 5‐fluorouracil which exhibits a strong cytostatic effect. In this paper, an analytical methodology was developed, validated, and applied to determine 5‐fluorouracil, its precursor, 5‐fluorocytosine, and its major active metabolite, 5‐fluorouridine, in hospital wastewater samples. Due to the expected low concentrations after dilution and interferences present in such a complex matrix, a very selective and sensitive detection method is required. Moreover, an extraction method must be implemented prior to the determination in order to purify the sample extract and preconcentrate the target analytes at micrograms per liter concentration levels. Solid‐phase extraction followed by liquid chromatography with tandem mass spectrometry was the combination of choice and all included parameters were studied. Under optimized conditions for wastewater samples analysis, recoveries from 63 to 108% were obtained, while intraday and interday relative standard deviations never exceeded 20 and 25%, respectively. Limits of detection between 61 and 620 ng/L were achieved. Finally, the optimized method was applied to samples from hospital wastewater effluents.  相似文献   

6.
A simple, low cost, fast and sensitive method is reported for the determination of the four endocrine disrupting chemicals (EDCs) 4-tert-butylphenol, 4-tert-octylphenol, bisphenol A and 17β-estradiol using pentafluoropyridine as the derivatizing reagent. These EDCs were determined by simultaneous extraction and derivatization in a solid phase analytical derivatization (SPAD) technique without the aid of any phase transfer catalyst (PTC) or an ion-pair mechanism. Recoveries of analytes as their tetrafluoropyridyl derivatives from water ranged from 71% for 4-tert-butylphenol to 106% for 17β-estradiol; from urine they ranged from 61% for 17β-estradiol to 91% for 4-tert-octylphenol; and from humic acids solution the ranged from 59% for 17β-estradiol to 104% for 4-tert-octylphenol in humic acid solutions. Calibration curves were constructed from a matrix of human male urine in the range 1-40 ng/mL and had coefficients of correlation greater than 0.99. For 4-tert-butylphenol, bisphenol A and 17β-estradiol the limits of quantitation were 5 ng/mL and for 4-tert-octylphenol it was 1 ng/mL. This method was applied to determine EDCs and detected 4-tert-octylphenol, bisphenol A and 17β-estradiol in concentrations comparable to those found in the literature. The method offers advantages in speed of analysis, reduced reagent and specificity of derivatization.  相似文献   

7.
This paper describes the optimisation of an analytical method for the simultaneous determination of up to 13 estrogenic endocrine disrupting compounds (EDCs), including natural and synthetic estrogens, alkylphenols, bisphenol A and phthalate esters, in atmospheric particulate matter. This methodology is based on pressurised liquid extraction and liquid chromatography-tandem mass spectrometry and is the first method described for analysis of estrogens in air. Samples were collected with high-volume samplers equipped with quartz microfiber filters. Two selected reaction monitoring transitions were chosen for identification and confirmation of the target compounds. Quantitation was performed by the internal standard method with the use of deuterated surrogate standards. The analytical features of the method were satisfactory: absolute recoveries were around 45 % for all compounds, except estrogens (~29 %), because of matrix effects. Repeatability was in all cases below 15 %. Quantitation limits of the method ranged from 5 pg/m3 (for diethylphthalate) to 83 pg/m3 (for 17-α-ethynylestradiol). As a part of the validation procedure, the developed method was applied to the analysis of eight air particulate samples (fine grain-size particles, PM2.5) collected in industrial, urban and non-polluted suburban areas of A Coruña (NW of Spain). Results evidenced the presence of dibutylphthalate, diethylhexylphthalate and nonylphenol in all samples. The highest concentration corresponded to dibutylphthalate (54.7 ng/m3) in an industrial area. Daily exposure to these EDCs in terms of estradiol equivalents (3 pg/day for toddlers and 5 pg/day for adults) is not expected to pose a risk to human health.  相似文献   

8.
This study describes the development of a multiresidue method based on gas chromatography-electron ionization-tandem mass spectrometry (GC-EI-MS/MS) for the detection of sixteen polycyclic aromatic hydrocarbons (PAHs), five phthalate esters (PEs), seven polychlorinated biphenyls (PCBs), six polybrominated diphenyl ethers (PBDEs), six alkylphenols (APs), three organochlorined pesticides and their isomers or degradation products (OCPs) and bisphenol A in seawater, river water, wastewater treatment plant (WWTP) effluents, sediments and mussels. Solid phase extraction (SPE) was used for the extraction of target analytes in aqueous samples, and ultrasound assisted extraction for solid samples. GC-EI-MS/MS acquisition conditions in selected reaction monitoring (SRM) using two transitions per compound were optimized. In this way, quantification and unequivocal identification of organic micropollutants were performed in compliance with the Decision 2002/657/EC. Good linearity responses with coefficients of determination higher than 0.99 were obtained. Methodological detection limits (MDLs) in seawater ranged from 0.1 to 6 ng L(-1); in river water from 0.1 to 4.8 ng L(-1); in WWTP effluents from 1 to 75 ng L(-1); in sediments from 1 to 150 ng g(-1) and in mussels from 1 to 125 ng g(-1). MDLs and recovery yields were compared with other published methods and similarities or even improvements were achieved. The optimized method was applied to analyze five samples from each matrix collected in coastal areas, showing its potential use for marine pollution monitoring.  相似文献   

9.
A new analytical method using stir-bar-sorptive extraction (SBSE) followed by liquid desorption (LD) and gas chromatography with triple-quadrupole mass spectrometric detection (GC-QqQ-MS-MS) has been used for quantitative determination of 25 chlorinated endocrine-disrupting compounds (EDCs) in river water and wastewater. The experimental conditions affecting the SBSE-LD performance were studied and are discussed in detail. Results from systematic assay revealed that a 100-mL water sample, stir bars coated with 47?μL PDMS, an extraction time of 14?h (at 900?rpm), 5?% MeOH as modifier and 10?% NaCl resulted in the best analytical recovery of all the target compounds studied. Use of 1:1 ACN-MeOH as back-extraction solvent and two successive sonication steps, each for 5?min, resulted in the best performance for monitoring EDCs in water matrices. The method detection limits for most of the target compounds were very good- ≤?2?ng?L(-1) and ≤10?ng?L(-1) for river water and wastewater effluents respectively. Experimental recovery for all the compounds was >70?%, with the exception of simazine for which recovery from the matrix was 65?%. Signal enhancement observed for a few of the compounds in wastewater effluents was managed by use of matrix-matched standards and different injection liners. The method was successfully used for analysis of river water samples from Henares River (Spain) and wastewater effluent samples from wastewater-treatment plants (WWTP). Eleven of the 25 compounds studied were detected in both river water and wastewater effluents. Terbutylazine and methoxychlor were detected in almost all the river water and effluent samples; amounts varied between 37-58.5?ng?L(-1) and 15.2-46.8?ng?L(-1), respectively. This method was shown enable reliable, effective, and sensitive monitoring of chlorinated EDCs at nanogram levels in surface water and wastewater effluent.  相似文献   

10.
In the present study, highly efficient and simple dispersive solid‐phase extraction procedure for the determination of haloacetic acids in water samples has been established. Three different types of layered double hydroxides were synthesized and used as a sorbent in dispersive solid‐phase extraction. Due to the interesting behavior of layered double hydroxides in an acidic medium (pH?4), the analyte elution step was not needed; the layered double hydroxides are simply dissolved in acid immediately after extraction to release the analytes which are then directly introduced into a liquid chromatography with tandem mass spectrometry system for analysis. Several dispersive solid‐phase extraction parameters were optimized to increase the extraction efficiency of haloacetic acids such as temperature, extraction time and pH. Under optimum conditions, good linearity was achieved over the concentration range of 0.05–100 μg/L with detection limits in the range of 0.006–0.05 μg/L. The relative standard deviations were 0.33–3.64% (n = 6). The proposed method was applied to different water samples collected from a drinking water plant to determine the concentrations of haloacetic acids.  相似文献   

11.
Polycyclic aromatic hydrocarbons (PAH) from ambient air particulate matter (PM) were analyzed by a new method that utilized direct immersion (DI) and cold fiber (CF) SPME-GC/MS. Experimental design was used to optimize the conditions of extraction by DI-CF-SPME with a 100μm polydimethylsiloxane (PDMS) fiber. The optimal conditions included a 5min equilibration at 70°C time in an ultrasonic bath with an extraction time of 60min. The optimized method was validated by the analysis of a NIST standard reference material (SRM), 1649b urban dust. The results obtained were in good agreement with certified values. PAH recoveries for reference materials were between 88 and 98%, with a relative standard deviation ranging from 5 to 17%. Detection limits (LOD) varied from 0.02 to 1.16ng and the quantification limits (LOQ) varied from 0.05 to 3.86ng. The optimized and validated method was applied to the determination of PAH from real particulate matter (PM10) and total suspended particulate (TPS) samples collected on quartz fiber filters with high volume samplers.  相似文献   

12.
The present study describes a method based on headspace-solid-phase dynamic extraction (HS-SPDE) followed by GC/MS for the qualitative and quantitative analysis of benzene, toluene, ethylbenzene, o-, m- and p-xylene (BTEX), and n-aldehydes (C(6)-C(10)) in water. To enhance the extraction capability of the HS-SPDE a new cooling device was tested that controls the temperature of the SPDE needle during extraction. Extraction and desorption parameters such as the number of extraction cycles, extraction temperature, desorption volume and desorption flow rate have been optimized. Detection limits for BTEX ranged from 19 ng/L (benzene) to 30 ng/L (m/p-xylene), while those for n-aldehydes ranged from 21 ng/L (n-heptanal) to 63 ng/L (n-hexanal). At a concentration level of 2 microg/L, the relative standard deviations (RSDs) for BTEX ranged from 3.9% (benzene) to 15.3% (ethylbenzene), while RSDs for n-aldehydes were between 6.1% (n-octanal) and 16.5% (n-hexanal) (n=7). Best results were obtained when the analyzed water samples were heated to 50 degrees C. At a water temperature of 70 degrees C GC responses decreased for all analyzed compounds. At a defined water temperature, a significant improvement of the GC response was achieved by cooling of the SPDE fiber during water extraction in comparison to an extraction keeping the fiber at room temperature. Evaluating the extraction cycles, for BTEX, the sensitivity was almost similar using 20, 40 and 60 extraction cycles. In contrast, the highest GC responses for n-aldehydes were achieved by the use of 60 extraction cycles. Optimizing the desorption parameters, best results were achieved using the smallest technical available desorption volume of 500 microL and the highest technical desorption flow rate of 50 microL/s. The method was applied to the analysis of melted snow samples taken from the Jungfraujoch, Switzerland (3580 m asl), revealing the presence of BTEX and aldehydes in snow.  相似文献   

13.
The study on the performance of polyaniline as a fiber coating for solid-phase microextraction (SPME) purposes has been reported. Polyaniline coatings were directly electrodeposited on the surface of a stainless steel wire and applied for the extraction of some organochlorine pesticides (OCPs) from water samples. Analyses were performed using GC-electron capture detection (GC-ECD). The results obtained show that polyaniline fiber coating is suitable for the successful extraction of organochlorine compounds. This behavior is most probably due to the porous surface structure of polyaniline film, which provides large surface areas and allowed for high extraction efficiency. Experimental parameters such as adsorption and desorption conditions were studied and optimized. The optimized method has an acceptable linearity, with a concentration range of 1-5000 ng/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 12 and 17%, respectively. High environmental resistance and lower cost are among the advantages of polyaniline fibers over commercially available SPME fibers. The developed method was applied to the analysis of real water samples from Yangtse River and Tianmu Lake.  相似文献   

14.
An integrated analytical method for the simultaneous determination of 4-n-nonylphenol (4-n-NP), nonylphenol monoethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), bisphenol A (BPA) and triclosan (TCS) in wastewater (dissolved and particulate phase) and sewage sludge was developed based on gas chromatography-mass spectrometry. Chromatographic analysis was achieved after derivatization with bis(trimethylsilyl)trifluoroacetamide (BSTFA). Extraction from water samples was performed by solid-phase extraction (SPE). The optimization of SPE procedure included the type of sorbent and the type of the organic solvent used for the elution. Referred to solid samples, the target compounds were extracted by sonication. In this case the optimization of the extraction procedure included the variation of the amount of the extracted biomass, the duration and the temperature of sonication and the type of the extraction organic solvent. The developed extraction procedures resulted in good repeatability and reproducibility with relative standard deviations (RSDs) less than 13% for all the tested compounds for both types of samples. Satisfactory recoveries were obtained (>60%) for all the compounds in both liquid and solid samples, except for 4-n-NP, which gave recoveries up to 35% in wastewater samples and up to 63% in sludge samples. The limits of detection (LODs) of the target compounds varied from 0.03 (4-n-NP) to 0.41 microg l(-1) (NP2EO) and from 0.04 (4-n-NP) to 0.96 microg kg(-1) (NP2EO) for liquid and solid samples, respectively. The developed methods were successfully applied to the analysis of the target compounds in real samples.  相似文献   

15.
A new method using gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the determination of four benzotriazoles, i.e. benzotriazole (BT), 5-methylbenzotriazole (5-TTri), 5-chlorobenzotriazole (CBT), 5,6-dimethylbenzotriazole (XTri), and six UV filters, i.e. benzophenone-3 (BP-3), 3-(4-methylbenzylidene)camphor (4-MBC), octyl 4-methoxycinnamate (OMC), 2-(3-t-butyl-2-hydroxy-5-methylphenyl)-5-chloro benzotriazole (UV-326), 2-(2'-hydroxy-5'-octylphenyl)-benzotriazole (UV-329), and octocrylene (OC) in ground water, effluent and biosolid samples. Solid phase extraction (SPE) and pressurized liquid extraction (PLE) were applied as the preconcentration method for water samples (ground water and effluent) and biosolid samples, respectively. The optimized method allowed us to quantify all target compounds with the method detection limits ranging from 0.29 to 11.02 ng/L, 0.5 to 14.1 ng/L and 0.33 to 8.23 ng/g in tap water, effluent and biosolid samples, respectively. The recoveries of the target analytes in tap water, effluent and biosolid samples were 70-150%, 82-127% and 81-133%, respectively. The developed analytical method was applied in the determination of these target compounds in ground water, effluent and biosolid samples collected from Bolivar sewage treatment plants in South Australia. In effluent samples, the target compounds BT, 5-TTri, CBT, XTri and BP-3 tested were detected with the maximum concentration up to 2.2 μg/L for BT. In biosolid samples, eight out of ten compounds tested were found to be present at the concentrations ranging between 18.7 ng/g (5-TTri) and 250 ng/g (4-MBC).  相似文献   

16.
Benzotriazole UV stabilizers are emerging compounds used in personal care products and can enter surface water after passing through wastewater treatment plants without being removed. Because these analytes are strongly hydrophobic, there is an environmental risk of accumulation in solid matrices and magnification through the trophic chain. In this work, a method based on stir bar sorption extraction with liquid desorption is presented for the extraction of benzotriazole UV stabilizers from water samples. Stir bar sorptive extraction was combined with ultra‐high performance LC with MS/MS detection. All important factors affecting the stir bar sorptive extraction procedure are discussed, and the optimized method was applied to seawater and wastewater samples from Gran Canaria Island, providing good selectivity and sensitivity with LODs and limits of quantification in the range of 18.4–55.1 and 61.5–184 ng/L, respectively. Recoveries between 68.4–92.2% were achieved for the more polar compounds, whereas the recoveries were lower for the two less polar compounds, most likely due to their strong absorption into the polydimethylsiloxane stir bar phase that does not allows the complete desorption. The repeatability studies gave RSDs of between 6.45 and 12.6% for all compounds in the real samples.  相似文献   

17.
A reliable multiresidue method based on solid phase extraction was developed using GC–MS to determine and quantify 34 pesticides, including herbicides, fungicides, insecticides, and some of their degradation products, in groundwater in a vineyard region of La Rioja (northern Spain). Different parameters were optimized and good recoveries (65–108% range) and precisions (12–19% range) were achieved with spiked water samples for a concentration of 0.1 μg/L. The experimental results showed an excellent linearity (r2 > 0.99) over the 0.1–1.5 μg/L range. The detection limits of the proposed method were 1–37 ng/L for most of the compounds studied. The methodology has been successfully applied to the analysis of groundwater samples from vineyard areas in La Rioja and the presence of pesticides, especially fungicides and herbicides, at several concentration levels was revealed. Terbuthylazine, its metabolite desethyl‐terbuthylazine, and fluometuron were the pesticides most frequently detected in higher concentrations. Overall and taking into consideration the European Union maximum residue limit of pesticides in groundwater, 16 of the 34 compounds included in this study were detected in concentrations over that limit in at least one of the samples analyzed.  相似文献   

18.
A solid–liquid extraction method in combination with high‐performance liquid chromatography and tandem mass spectrometry was developed and optimized for extraction and analysis of organophosphorus flame retardants in soil and fish. Methanol was chosen as the optimum extraction solvent, not only in terms of extraction efficiency, but also for its broader analyte coverage. The subsequent clean‐up by solid‐phase extraction is required to eliminate matrix coextractives and reduce matrix effects. Recoveries of the optimized method were 50–121% for soil and 47–123% for biota, both with high precision (RSDs <12% in soil and <23% in biota). The method limits of detection ranged from 0.06 to 0.20 ng/g dry weight and between 0.02 and 0.30 ng/g wet weight for soil and biota samples, respectively. However, samples with a high lipid content produce several problems as solid‐phase extraction cartridge clogging that increase variability and analysis time. The method was successfully applied for the determination of organophosphorus flame retardants in soil and fish from L'Albufera Natural Park (Valencia, Spain). Target compounds were detected in all soil and fish samples with values varying from 13.8 to 89.7 ng/g dry weight and from 3.3 to 53.0 ng/g wet weight, respectively.  相似文献   

19.
Microwave-assisted leaching of organotin compounds from sediment samples followed by the simultaneous extraction-derivatization of the extracted species was revisited with the goal to compare the existing procedures, improve their recoveries and extend them to phenyltin compounds. The stability of butyl- and phenyltin compounds under microwave field, real recoveries of the whole analytical procedure, effect of the extraction solvent, and the necessity for an internal standard were evaluated using two candidate reference sediments. The combination of the optimized sample preparation procedure with multicapillary chromatography resulted in a rapid (2 min leaching + 5 min extraction-derivatization + 3 min chromatographic separation) and efficient analytical procedure for speciation analysis of organotin compounds in sediment samples. The detection limit achieved with a microwave-induced plasma atomic emission detector was 2 ng g–1. Received: 27 July 1998 / Revised: 31 August 1998 / Accepted: 4 September 1998  相似文献   

20.
A novel solid phase microextraction fiber was prepared for the first time by using a sol–gel technique with hydroxypropyl‐β‐cyclodextrin‐functionalized reduced graphene oxide as the fiber coating material. The results verified that the β‐cyclodextrin was successfully grafted onto the surface of reduced graphene oxide and the coating possessed a uniform folded and wrinkled structure. The performance of the solid phase microextraction fiber was evaluated by using it to extract nine volatile aromatic compounds from water samples before determination with gas chromatography and flame ionization detection. Some important experimental parameters that could affect the extraction efficiency such as the extraction time, extraction temperature, desorption temperature, desorption time, the volume of water sample solution, stirring rate, as well as ionic strength were optimized. The new method was validated to be effective for the trace analysis of some volatile aromatic compounds, with the limits of detection ranging from 2.0 to 8.0 ng/L. Single fiber repeatability and fiber‐to‐fiber reproducibility were in the range of 2.5–9.4 and 5.4–12.9%, respectively. The developed method was successfully applied to the analysis of three different water samples, and the recoveries of the method were in the range from 77.9 to 113.6% at spiking levels of 10, 100, and 1000 ng/L, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号